Volumn 30, Issue 5, 2003, Pages 716-720

PET imaging with yttrium-86: Comparison of phantom measurements acquired with different PET scanners before and after applying background subtraction

Author keywords

BGO scanner; PET imaging; Phantom measurements; Yttrium 86

Indexed keywords

POLITEF; UNCLASSIFIED DRUG; WATER; YTTRIUM; YTTRIUM 86; YTTRIUM 90;

EID: 0038583768     PISSN: 16197070     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00259-002-1112-y     Document Type: Article
Times cited : (53)

References (12)
  • 1
    • 0027139813 scopus 로고
    • Measurement of pharmacokinetics of yttrium-86 radiopharmaceuticals with PET and radiation dose calculation of analogous yttrium-90 radiotherapeutics
    • Herzog H, Rösch F, Stöcklin G, Lueders C, Qaim SM, Feinendegen LE. Measurement of pharmacokinetics of yttrium-86 radiopharmaceuticals with PET and radiation dose calculation of analogous yttrium-90 radiotherapeutics. J Nucl Med 1993; 34:2222-2226.
    • (1993) J Nucl Med , vol.34 , pp. 2222-2226
    • Herzog, H.1    Rösch, F.2    Stöcklin, G.3    Lueders, C.4    Qaim, S.M.5    Feinendegen, L.E.6
  • 2
    • 0029737747 scopus 로고    scopus 로고
    • Radiation doses of yttrium-90 citrate and yttrium-90 EDTMP as determined via analogous yttrium-86 complexes and positron emission tomography
    • Rösch F, Herzog H, Plag C, Neumaier B, Braun U, Müller-Gärtner HW, Stöcklin G. Radiation doses of yttrium-90 citrate and yttrium-90 EDTMP as determined via analogous yttrium-86 complexes and positron emission tomography. Eur J Nucl Med 1996; 23:958-966.
    • (1996) Eur J Nucl Med , vol.23 , pp. 958-966
    • Rösch, F.1    Herzog, H.2    Plag, C.3    Neumaier, B.4    Braun, U.5    Müller-Gärtner, H.W.6    Stöcklin, G.7
  • 4
    • 0002239816 scopus 로고    scopus 로고
    • Quantitative imaging of yttrium-86 with PET. The occurrence and correction of anomalous apparent activity in high density regions
    • Pentlow KS, Finn RD, Larson SM, Erdi YE, Beattie BJ, Humm JL. Quantitative imaging of yttrium-86 with PET. The occurrence and correction of anomalous apparent activity in high density regions. Clin Positron Imaging 2000; 3:85-90.
    • (2000) Clin Positron Imaging , vol.3 , pp. 85-90
    • Pentlow, K.S.1    Finn, R.D.2    Larson, S.M.3    Erdi, Y.E.4    Beattie, B.J.5    Humm, J.L.6
  • 6
    • 0019525267 scopus 로고
    • Performance study of PETT VI, a positron computed tomograph with 288 cesium fluoride detectors
    • Yamamoto M, Ficke DC, Ter-Pogossian M. Performance study of PETT VI, a positron computed tomograph with 288 cesium fluoride detectors. IEEE Trans Nucl Sci 1982; 29:529-533.
    • (1982) IEEE Trans Nucl Sci , vol.29 , pp. 529-533
    • Yamamoto, M.1    Ficke, D.C.2    Ter-Pogossian, M.3
  • 10
    • 0020660172 scopus 로고
    • Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections
    • Bergström M, Eriksson L, Bohm C, Blomqvist G, Litton J. Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections. J Comput Assist Tomogr 1983; 7:42-50.
    • (1983) J Comput Assist Tomogr , vol.7 , pp. 42-50
    • Bergström, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4    Litton, J.5
  • 11
    • 0034244929 scopus 로고    scopus 로고
    • New, faster, image-based scatter correction for 3D PET
    • Watson CC. New, faster, image-based scatter correction for 3D PET. IEEE Trans Nucl Sci 2000; 47:1587-1594.
    • (2000) IEEE Trans Nucl Sci , vol.47 , pp. 1587-1594
    • Watson, C.C.1