메뉴 건너뛰기




Volumn 28, Issue 8, 2012, Pages 2099-2108

Artifact reduction strategies for prosthetic heart valve CT imaging

Author keywords

Computed tomography; Iterative reconstruction; Metal artifact reduction; Prosthetic heart valve; Tube voltage

Indexed keywords

ALGORITHM; ARTICLE; ARTIFACT; ARTIFACT REDUCTION; CLINICAL ASSESSMENT; CLINICAL EVALUATION; COMPUTER ASSISTED TOMOGRAPHY; ELECTRIC POTENTIAL; EQUIPMENT DESIGN; FILTER; HEART VALVE PROSTHESIS; IMAGE ANALYSIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; IN VITRO STUDY; NOISE MEASUREMENT; PROCESS OPTIMIZATION; QUANTITATIVE ANALYSIS; RADIATION DOSE; RADIATION EXPOSURE; STRATEGIC PLANNING;

EID: 84870537604     PISSN: 15695794     EISSN: 15730743     Source Type: Journal    
DOI: 10.1007/s10554-012-0041-5     Document Type: Article
Times cited : (21)

References (21)
  • 1
    • 62649154662 scopus 로고    scopus 로고
    • Correctness of multidetector- row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard
    • Tsai IC, Lin YK, Chang Y et al (2009) Correctness of multidetector- row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard. Eur Radiol 19:857-867.
    • (2009) Eur Radiol , vol.19 , pp. 857-867
    • Tsai, I.C.1    Lin, Y.K.2    Chang, Y.3
  • 2
    • 70349498637 scopus 로고    scopus 로고
    • Comparison of multidetector-row computed tomography to echocardiography and fluoroscopy for evaluation of patients with mechanical prosthetic valve obstruction
    • Symersky P, Budde RP, de Mol BA, Prokop M (2009) Comparison of multidetector-row computed tomography to echocardiography and fluoroscopy for evaluation of patients with mechanical prosthetic valve obstruction. Am J Cardiol 104:1128-1134.
    • (2009) Am J Cardiol , vol.104 , pp. 1128-1134
    • Symersky, P.1    Budde, R.P.2    De Mol, B.A.3    Prokop, M.4
  • 3
    • 46849120417 scopus 로고    scopus 로고
    • The role of ECG-gated MDCT in the evaluation of aortic and mitral mechanical valves: Initial experience
    • Konen E, Goitein O, Feinberg MS et al (2008) The role of ECG-gated MDCT in the evaluation of aortic and mitral mechanical valves: initial experience. Am J Roentgenol 191:26-31.
    • (2008) Am J Roentgenol , vol.191 , pp. 26-31
    • Konen, E.1    Goitein, O.2    Feinberg, M.S.3
  • 4
    • 79959379991 scopus 로고    scopus 로고
    • Prosthetic heart valve assessment with multidetector-row CT: Imaging characteristics of 91 valves in 83 patients
    • Habets J, Symersky P, van Herwerden LA et al (2011) Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients. Eur Radiol 21:1390-1396.
    • (2011) Eur Radiol , vol.21 , pp. 1390-1396
    • Habets, J.1    Symersky, P.2    Van Herwerden, L.A.3
  • 5
    • 79960966500 scopus 로고    scopus 로고
    • Diagnostic evaluation of left-sided prosthetic heart valve dysfunction
    • Habets J, Budde RP, Symersky P et al (2011) Diagnostic evaluation of left-sided prosthetic heart valve dysfunction. Nat Rev Cardiol 8:466-478.
    • (2011) Nat Rev Cardiol , vol.8 , pp. 466-478
    • Habets, J.1    Budde, R.P.2    Symersky, P.3
  • 6
    • 0035137190 scopus 로고    scopus 로고
    • Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: Trends in diagnostic testing and comparison with surgical findings
    • Girard SE, Miller FA Jr, Orszulak TA et al (2001) Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: trends in diagnostic testing and comparison with surgical findings. J Am Coll Cardiol 37:579- 584.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 579-584
    • Girard, S.E.1    Miller Jr., F.A.2    Orszulak, T.A.3
  • 7
    • 58549115527 scopus 로고    scopus 로고
    • Multislice computed tomography in infective endocarditis: Comparison with transesophageal echocardiography and intraoperative findings
    • Feuchtner GM, Stolzmann P, Dichtl W et al (2009) Multislice computed tomography in infective endocarditis: comparison with transesophageal echocardiography and intraoperative findings. J Am Coll Cardiol 53:436-444.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 436-444
    • Feuchtner, G.M.1    Stolzmann, P.2    Dichtl, W.3
  • 8
    • 80053926858 scopus 로고    scopus 로고
    • Multidetector CT imaging of mechanical prosthetic heart valves: Quantification of artifacts with a pulsatile in vitro model
    • Symersky P, Budde RP, Westers P, de Mol BA, Prokop M (2011) Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in vitro model. Eur Radiol 21:2103-2110.
    • (2011) Eur Radiol , vol.21 , pp. 2103-2110
    • Symersky, P.1    Budde, R.P.2    Westers, P.3    De Mol, B.A.4    Prokop, M.5
  • 9
    • 79957734869 scopus 로고    scopus 로고
    • Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves
    • Symersky P, Budde RP, Prokop M, de Mol BA (2011) Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves. J Heart Valve Dis 20:216-222.
    • (2011) J Heart Valve Dis , vol.20 , pp. 216-222
    • Symersky, P.1    Budde, R.P.2    Prokop, M.3    De Mol, B.A.4
  • 11
    • 79751531405 scopus 로고    scopus 로고
    • Computed tomography-old ideas and new technology
    • Fleischmann D, Boas FE (2011) Computed tomography-old ideas and new technology. Eur Radiol 21:510-517.
    • (2011) Eur Radiol , vol.21 , pp. 510-517
    • Fleischmann, D.1    Boas, F.E.2
  • 12
    • 19744369868 scopus 로고    scopus 로고
    • Artifacts in CT: Recognition and avoidance
    • Barrett JF, Keat N (2004) Artifacts in CT: recognition and avoidance. Radiographics 24:1679-1691.
    • (2004) Radiographics , vol.24 , pp. 1679-1691
    • Barrett, J.F.1    Keat, N.2
  • 13
    • 0347576136 scopus 로고    scopus 로고
    • Radiation dose and image quality
    • Prokop M, GalanskiM(eds), Thieme, Stuttgart and New York
    • Prokop M (2003) Radiation dose and image quality. In: Prokop M, GalanskiM(eds) Spiral and multislice computed tomography of the body. Thieme, Stuttgart and New York, pp 131-160.
    • (2003) Spiral and Multislice Computed Tomography of the Body , pp. 131-160
    • Prokop, M.1
  • 14
    • 77951585892 scopus 로고    scopus 로고
    • Evaluation of anatomic valve opening and leaflet morphology in aortic valve bioprosthesis by using multidetector CT: Comparison with transthoracic echocardiography
    • Chenot F, Montant P, Goffinet C et al (2010) Evaluation of anatomic valve opening and leaflet morphology in aortic valve bioprosthesis by using multidetector CT: comparison with transthoracic echocardiography. Radiology 255:377- 385.
    • (2010) Radiology , vol.255 , pp. 377-385
    • Chenot, F.1    Montant, P.2    Goffinet, C.3
  • 15
    • 79751538632 scopus 로고    scopus 로고
    • Evaluation of two iterative techniques for reducing metal artifacts in computed tomography
    • Boas FE, Fleischmann D (2011) Evaluation of two iterative techniques for reducing metal artifacts in computed tomography. Radiology 259:894-902.
    • (2011) Radiology , vol.259 , pp. 894-902
    • Boas, F.E.1    Fleischmann, D.2
  • 16
    • 84870477123 scopus 로고    scopus 로고
    • A novel iterative reconstruction algorithm allows reduced dose multidetector-row CT imaging of mechanical prosthetic heart valves
    • doi:10.1007/s10554-011-9954-7
    • Habets J, Symersky P, de Mol BA et al (2011) A novel iterative reconstruction algorithm allows reduced dose multidetector-row CT imaging of mechanical prosthetic heart valves. Int J Cardiovasc Imaging. doi:10.1007/s10554-011-9954-7.
    • (2011) Int J Cardiovasc Imaging
    • Habets, J.1    Symersky, P.2    De Mol, B.A.3
  • 17
    • 34249857538 scopus 로고    scopus 로고
    • Overcoming artifacts from metallic orthopedic implants at high-field-strengthMR imaging and multi-detector CT
    • Lee MJ, Kim S, Lee SA et al (2007) Overcoming artifacts from metallic orthopedic implants at high-field-strengthMR imaging and multi-detector CT. Radiographics 27:791-803.
    • (2007) Radiographics , vol.27 , pp. 791-803
    • Lee, M.J.1    Kim, S.2    Lee, S.A.3
  • 18
    • 33746633331 scopus 로고    scopus 로고
    • Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
    • Bal M, Spies L (2006) Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. Med Phys 33:2852-2859.
    • (2006) Med Phys , vol.33 , pp. 2852-2859
    • Bal, M.1    Spies, L.2
  • 19
    • 75749108974 scopus 로고    scopus 로고
    • Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT
    • Veldkamp WJ, Joemai RM, van der Molen AJ, Geleijns J (2010) Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT. Med Phys 37:620-628.
    • (2010) Med Phys , vol.37 , pp. 620-628
    • Veldkamp, W.J.1    Joemai, R.M.2    Van Der Molen, A.J.3    Geleijns, J.4
  • 20
    • 84861531307 scopus 로고    scopus 로고
    • Prospective ECG triggering reduces prosthetic heart valve-induced artefacts compared with retrospective ECG gating on 256-slice CT
    • doi:10.1007/s00330-011-2358-1
    • Symersky P, Habets J, Westers P et al (2011) Prospective ECG triggering reduces prosthetic heart valve-induced artefacts compared with retrospective ECG gating on 256-slice CT. Eur Radiol. doi:10.1007/s00330-011-2358-1.
    • (2011) Eur Radiol
    • Symersky, P.1    Habets, J.2    Westers, P.3
  • 21
    • 0442323707 scopus 로고    scopus 로고
    • Usefulness of a multidetector-row computed tomography scanner for detecting pannus formation
    • Teshima H, Hayashida N, Fukunaga S et al (2004) Usefulness of a multidetector-row computed tomography scanner for detecting pannus formation. Ann Thorac Surg 77: 523-526.
    • (2004) Ann Thorac Surg , vol.77 , pp. 523-526
    • Teshima, H.1    Hayashida, N.2    Fukunaga, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.