메뉴 건너뛰기




Volumn 21, Issue 10, 2011, Pages 2103-2110

Multidetector CT imaging of mechanical prosthetic heart valves: Quantification of artifacts with a pulsatile in-vitro model

Author keywords

Artifacts; Cardiac; CT; Heart valve prosthesis; In vitro

Indexed keywords

ARTICLE; ARTIFACT; CARBOMEDICS PROSTHETIC HEART VALVE; COMPARATIVE STUDY; HEART VALVE PROSTHESIS; IMAGE PROCESSING; IMAGE QUALITY; IN VITRO STUDY; MEDTRONIC HALL HEART VALVE PROSTHESIS; MULTIDETECTOR COMPUTED TOMOGRAPHY; ON X BILEAFLET HEART VALVE PROSTHESIS; PRIORITY JOURNAL; SAINT JUDE HEART VALVE PROSTHESIS;

EID: 80053926858     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-011-2146-y     Document Type: Article
Times cited : (14)

References (14)
  • 1
    • 2542496945 scopus 로고    scopus 로고
    • A pragmatic approach to metal artifact reduction in CT: Merging of metal artifact reduced images
    • 15014974 10.1007/s00330-004-2263-y
    • O Watzke WA Kalender 2004 A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images Eur Radiol 14 849 856 15014974 10.1007/s00330-004-2263-y
    • (2004) Eur Radiol , vol.14 , pp. 849-856
    • Watzke, O.1    Kalender, W.A.2
  • 2
    • 0345708391 scopus 로고    scopus 로고
    • A new algorithm for metal artifact reduction in computed tomography: In vitro and in vivo evaluation after total hip replacement
    • 14627894 10.1097/01.rli.0000086495.96457.54
    • AH Mahnken R Raupach JE Wildberger B Jung N Heussen TG Flohr RW Günther S Schaller 2003 A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement Invest Radiol 38 769 775 14627894 10.1097/01.rli.0000086495.96457.54
    • (2003) Invest Radiol , vol.38 , pp. 769-775
    • Mahnken, A.H.1    Raupach, R.2    Wildberger, J.E.3    Jung, B.4    Heussen, N.5    Flohr, T.G.6    Günther, R.W.7    Schaller, S.8
  • 3
    • 73949111106 scopus 로고    scopus 로고
    • Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: Techniques and initial clinical results
    • 19809345 10.1097/RLI.0b013e3181b0a2f9
    • L Yu H Li J Mueller JM Kofler X Liu AN Primak JG Fletcher LS Guimaraes T Macedo CH Mc Collough 2009 Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: techniques and initial clinical results Invest Radiol 44 691 696 19809345 10.1097/RLI. 0b013e3181b0a2f9
    • (2009) Invest Radiol , vol.44 , pp. 691-696
    • Yu, L.1    Li, H.2    Mueller, J.3    Kofler, J.M.4    Liu, X.5    Primak, A.N.6    Fletcher, J.G.7    Guimaraes, L.S.8    MacEdo, T.9    Mc Collough, C.H.10
  • 5
    • 0442323707 scopus 로고    scopus 로고
    • Usefulness of a multidetector-row computed tomography scanner for detecting pannus formation
    • 14759431 10.1016/S0003-4975(03)01531-5
    • H Teshima N Hayashida S Fukunaga E Tayama T Kawara S Aoyagi M Uchida 2004 Usefulness of a multidetector-row computed tomography scanner for detecting pannus formation Ann Thorac Surg 77 523 526 14759431 10.1016/S0003-4975(03) 01531-5
    • (2004) Ann Thorac Surg , vol.77 , pp. 523-526
    • Teshima, H.1    Hayashida, N.2    Fukunaga, S.3    Tayama, E.4    Kawara, T.5    Aoyagi, S.6    Uchida, M.7
  • 6
    • 62649154662 scopus 로고    scopus 로고
    • Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard
    • 19037643 10.1007/s00330-008-1232-2
    • IC Tsai YK Lin YFuYC Chang CC Wang SR Hsieh HJ Wei HW Tsai SL Jan KY Wang MC Chen CC Chen 2009 Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard Eur Radiol 19 857 867 19037643 10.1007/s00330-008-1232-2
    • (2009) Eur Radiol , vol.19 , pp. 857-867
    • Tsai, I.C.1    Lin, Y.K.2    Yfuyc, C.3    Wang, C.C.4    Hsieh, S.R.5    Wei, H.J.6    Tsai, H.W.7    Jan, S.L.8    Wang, K.Y.9    Chen, M.C.10    Chen, C.C.11
  • 7
    • 70349498637 scopus 로고    scopus 로고
    • Comparison of multidetector-row computed tomography to echocardiography and fluoroscopy for evaluation of patients with mechanical prosthetic valve obstruction
    • 19801036 10.1016/j.amjcard.2009.05.061
    • P Symersky RPJ Budde BAJM de Mol M Prokop 2009 Comparison of multidetector-row computed tomography to echocardiography and fluoroscopy for evaluation of patients with mechanical prosthetic valve obstruction Am J Cardiol 104 1128 1134 19801036 10.1016/j.amjcard.2009.05.061
    • (2009) Am J Cardiol , vol.104 , pp. 1128-1134
    • Symersky, P.1    Budde, R.P.J.2    De Mol Bajm3    Prokop, M.4
  • 8
    • 46849120417 scopus 로고    scopus 로고
    • The role of ECG-gated MDCT in the evaluation of aortic and mitral mechanical valves: Initial experience
    • 10.2214/AJR.07.2951
    • E Konen O Goitein MS Feinberg Y Eshet E Raanani U Rimon E Di-Segni 2008 The role of ECG-gated MDCT in the evaluation of aortic and mitral mechanical valves: initial experience Am J Roentgenol 191 26 31 10.2214/AJR.07.2951
    • (2008) Am J Roentgenol , vol.191 , pp. 26-31
    • Konen, E.1    Goitein, O.2    Feinberg, M.S.3    Eshet, Y.4    Raanani, E.5    Rimon, U.6    Di-Segni, E.7
  • 9
    • 0035137190 scopus 로고    scopus 로고
    • Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: Trends in diagnostic testing and comparison with surgical findings
    • 11216982 10.1016/S0735-1097(00)01113-X 1:STN:280:DC%2BD3M7jsFWktQ%3D%3D
    • SE Girard FA Miller TA Orszulak CJ Mullany S Montgomery WD Edwards HD Tazelaar JF Malouf AJ Tajik 2001 Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: trends in diagnostic testing and comparison with surgical findings J Am Coll Cardiol 37 579 584 11216982 10.1016/S0735-1097(00)01113-X 1:STN:280:DC%2BD3M7jsFWktQ%3D%3D
    • (2001) J Am Coll Cardiol , vol.37 , pp. 579-584
    • Girard, S.E.1    Miller, F.A.2    Orszulak, T.A.3    Mullany, C.J.4    Montgomery, S.5    Edwards, W.D.6    Tazelaar, H.D.7    Malouf, J.F.8    Tajik, A.J.9
  • 10
    • 0034101562 scopus 로고    scopus 로고
    • Incorrect echocardiographic diagnosis in patients with mechanical prosthetic valve dysfunction: Correlation with surgical findings
    • 10806281 10.1016/S0002-9343(00)00344-2 1:STN:280:DC%2BD3c3mslGnuw%3D%3D
    • F Faletra C Constantin F De Chiara G Masciocco G Santambrogio A Moreo A Alberti E Vitali A Pellegrini 2000 Incorrect echocardiographic diagnosis in patients with mechanical prosthetic valve dysfunction: correlation with surgical findings Am J Med 108 531 537 10806281 10.1016/S0002-9343(00)00344-2 1:STN:280:DC%2BD3c3mslGnuw%3D%3D
    • (2000) Am J Med , vol.108 , pp. 531-537
    • Faletra, F.1    Constantin, C.2    De Chiara, F.3    Masciocco, G.4    Santambrogio, G.5    Moreo, A.6    Alberti, A.7    Vitali, E.8    Pellegrini, A.9
  • 11
    • 79957734869 scopus 로고    scopus 로고
    • Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves
    • 21560825
    • P Symersky RPJ Budde M Prokop BAJM de Mol 2011 Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves J Heart Valve Dis 20 216 222 21560825
    • (2011) J Heart Valve Dis , vol.20 , pp. 216-222
    • Symersky, P.1    Budde, R.P.J.2    Prokop, M.3    De Mol Bajm4
  • 12
    • 79959379991 scopus 로고    scopus 로고
    • Prosthetic heart valve assessment with multidetector-row CT: Imaging characteristics of 91 valves in 83 patients
    • 10.1007/s00330-011-2068-8 21279515
    • J Habets P Symersky LA van Herwerden BAJM de Mol AM Spijkerboer WPTM Mali RPJ Budde 2011 Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients Eur Radiol. 10.1007/s00330-011-2068-8 21279515
    • (2011) Eur Radiol.
    • Habets, J.1    Symersky, P.2    Van Herwerden, L.A.3    De Mol Bajm4    Spijkerboer, A.M.5    Wptm, M.6    Budde, R.P.J.7
  • 13
    • 19744369868 scopus 로고    scopus 로고
    • Artifacts in CT: Recognition and avoidance
    • 15537976 10.1148/rg.246045065
    • JF Barrett N Keat 2004 Artifacts in CT: recognition and avoidance Radiographics 24 1679 1691 15537976 10.1148/rg.246045065
    • (2004) Radiographics , vol.24 , pp. 1679-1691
    • Barrett, J.F.1    Keat, N.2
  • 14
    • 77951585892 scopus 로고    scopus 로고
    • Evaluation of anatomic valve opening and leaflet morphology in aortic valve bioprosthesis by using multidetector CT: Comparison with transthoracic echocardiography
    • 20019133 10.1148/radiol.0000082294
    • F Chenot P Montant C Goffinet A Pasquet D Vancraeynest E Coche JL Vanoverschelde BL Gerber 2010 Evaluation of anatomic valve opening and leaflet morphology in aortic valve bioprosthesis by using multidetector CT: comparison with transthoracic echocardiography Radiology 255 377 385 20019133 10.1148/radiol.0000082294
    • (2010) Radiology , vol.255 , pp. 377-385
    • Chenot, F.1    Montant, P.2    Goffinet, C.3    Pasquet, A.4    Vancraeynest, D.5    Coche, E.6    Vanoverschelde, J.L.7    Gerber, B.L.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.