메뉴 건너뛰기




Volumn 57, Issue 23, 2012, Pages 7863-7872

Proof of concept of MRI-guided tracked radiation delivery: Tracking one-dimensional motion

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL ORGANS; ACQUISITION TIME; BEAM COLLIMATION; DELIVERY SYSTEMS; DOSE ACCUMULATION; DOSE DISTRIBUTIONS; GAFCHROMIC FILMS; GEOMETRICAL ACCURACY; GEOMETRICAL UNCERTAINTY; GUIDANCE STRATEGY; IMAGE GUIDANCES; IMAGE PROCESSING PROBLEMS; MOTION MANAGEMENT; MOVING TARGETS; MR SCANNERS; MR SEQUENCE; MULTILEAF COLLIMATORS; ONE-DIMENSIONAL MOTIONS; OPTIMAL METHODS; ORGANS AT RISKS; PROOF OF CONCEPT; RADIATION DELIVERY; REAL-TIME COMMUNICATION; RESPIRATORY MOTIONS; TECHNICAL FEASIBILITY; TIME-RESOLVED;

EID: 84870373309     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/57/23/7863     Document Type: Article
Times cited : (90)

References (43)
  • 2
    • 0842327792 scopus 로고    scopus 로고
    • Effects of Motion on the Total Dose Distribution
    • DOI 10.1053/j.semradonc.2003.10.011
    • Bortfeld T, Jiang S B and Rietzel E 2004 Effects of motion on the total dose distribution Semin. Radiat. Oncol. 14 41-51 (Pubitemid 38168953)
    • (2004) Seminars in Radiation Oncology , vol.14 , Issue.1 , pp. 41-51
    • Bortfeld, T.1    Jiang, S.B.2    Rietzel, E.3
  • 3
    • 0037036516 scopus 로고    scopus 로고
    • Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation
    • DOI 10.1088/0031-9155/47/13/302, PII S0031915502342490
    • Bortfeld T, Jokivarsi K, Goitein M, Kung J and Jiang S B 2002 Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation Phys. Med. Biol. 47 2203 (Pubitemid 34812201)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.13 , pp. 2203-2220
    • Bortfeld, T.1    Jokivarsi, K.2    Goitein, M.3    Kung, J.4    Jiang, S.B.5
  • 4
    • 78650012111 scopus 로고    scopus 로고
    • DMLC tracking with real-time target position estimation combining a single kV imager and an optical respiratory monitoring system
    • 10.1016/j.ijrobp.2009.07.080 0360-3016
    • Cho B, Poulsen P R, Ruan D, Sawant A, Povzner S and Keall P J 2009a DMLC tracking with real-time target position estimation combining a single kV imager and an optical respiratory monitoring system Int. J. Radiat. Oncol. Biol. Phys. 75 S24-5
    • (2009) Int. J. Radiat. Oncol. Biol. Phys. , vol.75 , Issue.3
    • Cho, B.1    Poulsen, P.R.2    Ruan, D.3    Sawant, A.4    Povzner, S.5    Keall, P.J.6
  • 5
    • 78650024202 scopus 로고    scopus 로고
    • Real-time target position estimation using stereoscopic kilovoltage/megavoltage imaging and external respiratory monitoring for dynamic multileaf collimator tracking
    • 10.1016/j.ijrobp.2010.02.052 0360-3016
    • Cho B, Poulsen P R, Sawant A, Ruan D and Keall P J 2011 Real-time target position estimation using stereoscopic kilovoltage/megavoltage imaging and external respiratory monitoring for dynamic multileaf collimator tracking Int. J. Radiat. Oncol. Biol. Phys. 79 269-78
    • (2011) Int. J. Radiat. Oncol. Biol. Phys. , vol.79 , Issue.1 , pp. 269-278
    • Cho, B.1    Poulsen, P.R.2    Sawant, A.3    Ruan, D.4    Keall, P.J.5
  • 6
    • 67049086549 scopus 로고    scopus 로고
    • First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking
    • 10.1016/j.ijrobp.2009.02.012 0360-3016
    • Cho B, Poulsen P R, Sloutsky A, Sawant A and Keall P J 2009b First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking Int. J. Radiat. Oncol. Biol. Phys. 74 859-67
    • (2009) Int. J. Radiat. Oncol. Biol. Phys. , vol.74 , Issue.3 , pp. 859-867
    • Cho, B.1    Poulsen, P.R.2    Sloutsky, A.3    Sawant, A.4    Keall, P.J.5
  • 7
    • 79961092524 scopus 로고    scopus 로고
    • Towards MRI-guided linear accelerator control: Gating on an MRI accelerator
    • 10.1088/0031-9155/56/15/012 0031-9155
    • Crijns S P M, Kok J G M, Lagendijk J J W and Raaymakers B W 2011 Towards MRI-guided linear accelerator control: gating on an MRI accelerator Phys. Med. Biol. 56 4815-25
    • (2011) Phys. Med. Biol. , vol.56 , Issue.15 , pp. 4815-4825
    • Crijns, S.P.M.1    Kok, J.G.M.2    Lagendijk, J.J.W.3    Raaymakers, B.W.4
  • 8
    • 79952448789 scopus 로고    scopus 로고
    • Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system
    • 10.1016/j.radonc.2011.01.015 0167-8140
    • Depuydt T et al 2011 Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system Radiother. Oncol. 98 365-72
    • (2011) Radiother. Oncol. , vol.98 , Issue.3 , pp. 365-372
    • Depuydt, T.1
  • 9
    • 24044543599 scopus 로고    scopus 로고
    • Real-time intra-fraction-motion tracking using the treatment couch: A feasibility study
    • DOI 10.1088/0031-9155/50/17/007
    • D'Souza W D, Naqvi S A and Yu C X 2005 Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study Phys. Med. Biol. 50 4021 (Pubitemid 41225253)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.17 , pp. 4021-4033
    • D'Souza, W.D.1    Naqvi, S.A.2    Yu, C.X.3
  • 10
    • 68549107645 scopus 로고    scopus 로고
    • Forecasting respiratory motion with accurate online support vector regression (SVRpred)
    • 10.1007/s11548-009-0355-5 1861-6410
    • Ernst F and Schweikard A 2009 Forecasting respiratory motion with accurate online support vector regression (SVRpred) Int. J. Comput. Assist. Radiol. Surg. 4 439-47
    • (2009) Int. J. Comput. Assist. Radiol. Surg. , vol.4 , Issue.5 , pp. 439-447
    • Ernst, F.1    Schweikard, A.2
  • 11
    • 78650042812 scopus 로고    scopus 로고
    • A state-based probabilistic model for tumor respiratory motion prediction
    • 10.1088/0031-9155/55/24/015 0031-9155
    • Kalet A, Sandison G, Wu H and Schmitz R 2010 A state-based probabilistic model for tumor respiratory motion prediction Phys. Med. Biol. 55 7615-31
    • (2010) Phys. Med. Biol. , vol.55 , Issue.24 , pp. 7615-7631
    • Kalet, A.1    Sandison, G.2    Wu, H.3    Schmitz, R.4
  • 13
    • 17844385102 scopus 로고    scopus 로고
    • Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking
    • DOI 10.1118/1.1879152
    • Keall P J, Joshi S, Vedam S S, Siebers J V, Kini V R and Mohan R 2005 Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking Med. Phys. 32 942 (Pubitemid 40586779)
    • (2005) Medical Physics , vol.32 , Issue.4 , pp. 942-951
    • Keall, P.J.1    Joshi, S.2    Sastry Vedam, S.3    Siebers, J.V.4    Kini, V.R.5    Mohan, R.6
  • 14
    • 0035136220 scopus 로고    scopus 로고
    • Motion adaptive x-ray therapy: A feasibility study
    • DOI 10.1088/0031-9155/46/1/301, PII S003191550116478X
    • Keall P J, Kini V R, Vedam S S and Mohan R 2001 Motion adaptive x-ray therapy: a feasibility study Phys. Med. Biol. 46 1-10 (Pubitemid 32104867)
    • (2001) Physics in Medicine and Biology , vol.46 , Issue.1 , pp. 1-10
    • Keall, P.J.1    Kini, V.R.2    Vedam, S.S.3    Mohan, R.4
  • 16
    • 38149078236 scopus 로고    scopus 로고
    • Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance
    • 10.1016/j.radonc.2007.10.038 0167-8140
    • Korreman S S, Juhler-Nottrup T and Boyer A L 2008 Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance Radiother. Oncol. 86 61-8
    • (2008) Radiother. Oncol. , vol.86 , Issue.1 , pp. 61-68
    • Korreman, S.S.1    Juhler-Nottrup, T.2    Boyer, A.L.3
  • 18
    • 50449084816 scopus 로고    scopus 로고
    • A real-time dynamic-MLC control algorithm for delivering IMRT to targets undergoing 2D rigid motion in the beams eye view
    • 10.1118/1.2963987 0094-2405
    • McMahon R, Berbeco R, Nishioka S, Ishikawa M and Papiez L 2008 A real-time dynamic-MLC control algorithm for delivering IMRT to targets undergoing 2D rigid motion in the beams eye view Med. Phys. 35 3875
    • (2008) Med. Phys. , vol.35 , Issue.9 , pp. 3875
    • McMahon, R.1    Berbeco, R.2    Nishioka, S.3    Ishikawa, M.4    Papiez, L.5
  • 19
    • 33748537791 scopus 로고    scopus 로고
    • IMRT delivery to a moving target by dynamic MLC tracking: Delivery for targets moving in two dimensions in the beam's eye view
    • DOI 10.1088/0031-9155/51/19/007, PII S0031915506215276, 007
    • McQuaid D and Webb S 2006 IMRT delivery to a moving target by dynamic MLC tracking: delivery for targets moving in two dimensions in the beam's eye view Phys. Med. Biol. 51 4819 (Pubitemid 44429846)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.19 , pp. 4819-4839
    • McQuaid, D.1    Webb, S.2
  • 20
    • 63849198448 scopus 로고    scopus 로고
    • Adapting liver motion models using a navigator channel technique
    • 10.1118/1.3077923 0094-2405
    • Nguyen T N, Moseley J L, Dawson L A, Jaffray D A and Brock K K 2009 Adapting liver motion models using a navigator channel technique Med. Phys. 36 1061-73
    • (2009) Med. Phys. , vol.36 , Issue.4 , pp. 1061-1073
    • Nguyen, T.N.1    Moseley, J.L.2    Dawson, L.A.3    Jaffray, D.A.4    Brock, K.K.5
  • 21
    • 12844267410 scopus 로고    scopus 로고
    • DMLC leaf-pair optimal control for mobile, deforming target
    • DOI 10.1118/1.1833591
    • Papiez L and Rangaraj D 2005 DMLC leaf-pair optimal control for mobile, deforming target Med. Phys. 32 275-84 (Pubitemid 40165540)
    • (2005) Medical Physics , vol.32 , Issue.1 , pp. 275-285
    • Papiez, L.1    Rangaraj, D.2
  • 22
    • 25644438567 scopus 로고    scopus 로고
    • Real-time DMLC IMRT delivery for mobile and deforming targets
    • DOI 10.1118/1.1987967
    • Papiez L, Rangaraj D and Keall P 2005 Real-time DMLC IMRT delivery for mobile and deforming targets Med. Phys. 32 3037 (Pubitemid 41384101)
    • (2005) Medical Physics , vol.32 , Issue.9 , pp. 3037-3048
    • Papiez, L.1    Rangaraj, D.2    Keall, P.3
  • 23
    • 77951877433 scopus 로고    scopus 로고
    • Dynamic multileaf collimator tracking of respiratory target motion based on a single kilovoltage imager during arc radiotherapy
    • 10.1016/j.ijrobp.2009.08.030 0360-3016
    • Poulsen P R, Cho B, Ruan D, Sawant A and Keall P J 2010 Dynamic multileaf collimator tracking of respiratory target motion based on a single kilovoltage imager during arc radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 77 600-7
    • (2010) Int. J. Radiat. Oncol. Biol. Phys. , vol.77 , Issue.2 , pp. 600-607
    • Poulsen, P.R.1    Cho, B.2    Ruan, D.3    Sawant, A.4    Keall, P.J.5
  • 24
    • 70149091087 scopus 로고    scopus 로고
    • Integrating a 1.5 T MRI scanner with a 6 MV accelerator: Proof of concept
    • Raaymakers B W et al 2009 Integrating a 1.5 T MRI scanner with a 6 MV accelerator: proof of concept Phys. Med. Biol. 54 229-37
    • (2009) Phys. Med. Biol. , vol.54 , pp. 229-237
    • Raaymakers, B.W.1
  • 25
    • 48349102213 scopus 로고    scopus 로고
    • DMLC IMRT delivery to targets moving in 2D in beams eye view
    • 10.1118/1.2952775 0094-2405
    • Rangaraj D, Palaniswaamy G and Papiez L 2008 DMLC IMRT delivery to targets moving in 2D in beams eye view Med. Phys. 35 3765
    • (2008) Med. Phys. , vol.35 , Issue.8 , pp. 3765
    • Rangaraj, D.1    Palaniswaamy, G.2    Papiez, L.3
  • 26
    • 79960540466 scopus 로고    scopus 로고
    • Geometric accuracy of dynamic MLC tracking with an implantable wired electromagnetic transponder
    • 10.3109/0284186X.2011.590524 0284-186X
    • Ravkilde T, Keall P J, Hojbjerre K, Fledelius W, Worm E and Poulsen P R 2011 Geometric accuracy of dynamic MLC tracking with an implantable wired electromagnetic transponder Acta Oncol. 50 944-51
    • (2011) Acta Oncol. , vol.50 , Issue.6 , pp. 944-951
    • Ravkilde, T.1    Keall, P.J.2    Hojbjerre, K.3    Fledelius, W.4    Worm, E.5    Poulsen, P.R.6
  • 27
    • 78649593742 scopus 로고    scopus 로고
    • Real-time 3D target tracking in MRI guided focused ultrasound ablations in moving tissues
    • 10.1002/mrm.22548 0740-3194
    • Ries M, De Senneville B D, Roujol S, Berber Y, Quesson B and Moonen C 2010 Real-time 3D target tracking in MRI guided focused ultrasound ablations in moving tissues Magn. Reson. Med. 64 1704-12
    • (2010) Magn. Reson. Med. , vol.64 , Issue.6 , pp. 1704-1712
    • Ries, M.1    De Senneville, B.D.2    Roujol, S.3    Berber, Y.4    Quesson, B.5    Moonen, C.6
  • 28
    • 76849090485 scopus 로고    scopus 로고
    • Kernel density estimation-based real-time prediction for respiratory motion
    • 10.1088/0031-9155/55/5/004 0031-9155
    • Ruan D 2010 Kernel density estimation-based real-time prediction for respiratory motion Phys. Med. Biol. 55 1311-26
    • (2010) Phys. Med. Biol. , vol.55 , Issue.5 , pp. 1311-1326
    • Ruan, D.1
  • 29
    • 65449175240 scopus 로고    scopus 로고
    • Toward submillimeter accuracy in the management of intrafraction motion: The integration of real-time internal position monitoring and multileaf collimator target tracking
    • 10.1016/j.ijrobp.2008.12.057 0360-3016
    • Sawant A, Smith R L, Venkat R B, Santanam L, Cho B, Poulsen P, Cattell H, Newell L J, Parikh P and Keall P J 2009 Toward submillimeter accuracy in the management of intrafraction motion: the integration of real-time internal position monitoring and multileaf collimator target tracking Int. J. Radiat. Oncol. Biol. Phys. 74 575-82
    • (2009) Int. J. Radiat. Oncol. Biol. Phys. , vol.74 , Issue.2 , pp. 575-582
    • Sawant, A.1    Smith, R.L.2    Venkat, R.B.3    Santanam, L.4    Cho, B.5    Poulsen, P.6    Cattell, H.7    Newell, L.J.8    Parikh, P.9    Keall, P.J.10
  • 30
    • 0032045971 scopus 로고    scopus 로고
    • The design of the TAO real-time object request broker
    • PII S0140366497001655
    • Schmidt D C, Levine D L and Mungee S 1998 The design of the TAO real-time object request broker Comput. Commun. 21 294-324 (Pubitemid 128393951)
    • (1998) Computer Communications , vol.21 , Issue.4 , pp. 294-324
    • Schmidt, D.C.1    Levine, D.L.2    Mungee, S.3
  • 31
    • 84875366925 scopus 로고    scopus 로고
    • Ultrasound echoes as biometric navigators
    • Schwartz B M and McDannold N J 2012 Ultrasound echoes as biometric navigators Magn. Reson. Med. at press (doi:10.1002/mrm.24336)
    • (2012) Magn. Reson. Med.
    • Schwartz, B.M.1    McDannold, N.J.2
  • 32
    • 0033743945 scopus 로고    scopus 로고
    • Robotic motion compensation for respiratory movement during radiosurgery
    • 10.3109/10929080009148894 1092-9088
    • Schweikard A, Glosser G, Bodduluri M, Murphy M J and Adler J R 2000 Robotic motion compensation for respiratory movement during radiosurgery Comput. Aided Surg. 5 263-77
    • (2000) Comput. Aided Surg. , vol.5 , Issue.4 , pp. 263-277
    • Schweikard, A.1    Glosser, G.2    Bodduluri, M.3    Murphy, M.J.4    Adler, J.R.5
  • 33
    • 1142299677 scopus 로고    scopus 로고
    • Prediction of respiratory tumour motion for real-time image-guided radiotherapy
    • DOI 10.1088/0031-9155/49/3/006, PII S0031915504696072
    • Sharp G C, Jiang S B, Shimizu S and Shirato H 2004 Prediction of respiratory tumour motion for real-time image-guided radiotherapy Phys. Med. Biol. 49 425-40 (Pubitemid 38208152)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.3 , pp. 425-440
    • Sharp, G.S.1    Jiang, S.B.2    Shimizu, S.3    Shirato, H.4
  • 36
    • 1942452264 scopus 로고    scopus 로고
    • Aperture maneuver with compelled breath (AMC) for moving tumors: A feasibility study with a moving phantom
    • DOI 10.1118/1.1650565
    • Suh Y, Yi B, Ahn S, Kim J, Lee S, Shin S and Choi E 2004 Aperture maneuver with compelled breath (AMC) for moving tumors: a feasibility study with a moving phantom Med. Phys. 31 760-6 (Pubitemid 38508856)
    • (2004) Medical Physics , vol.31 , Issue.4 , pp. 760-766
    • Suh, Y.1    Yi, B.2    Ahn, S.3    Kim, J.4    Lee, S.5    Shin, S.6    Shin, S.7    Choi, E.8
  • 37
    • 4544356974 scopus 로고    scopus 로고
    • Inclusion of organ movements in IMRT treatment planning via inverse planning based on probability distributions
    • DOI 10.1088/0031-9155/49/17/013, PII S0031915504795408
    • Unkelbach J and Oelfke U 2004 Inclusion of organ movements in IMRT treatment planning via inverse planning based on probability distributions Phys. Med. Biol. 49 4005-29 (Pubitemid 39242991)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.17 , pp. 4005-4029
    • Unkelbach, J.1    Oelfke, U.2
  • 42
    • 84870351692 scopus 로고    scopus 로고
    • Towards fast and accurate temperature mapping with proton resonance frequency-based MR thermometry
    • Yuan J, Mei C S, Panych L P, McDannold N J and Madore B 2012 Towards fast and accurate temperature mapping with proton resonance frequency-based MR thermometry Quant. Imaging Med. Surg. 2 21-32
    • (2012) Quant. Imaging Med. Surg. , vol.2 , pp. 21-32
    • Yuan, J.1    Mei, C.S.2    Panych, L.P.3    McDannold, N.J.4    Madore, B.5
  • 43
    • 84857870576 scopus 로고    scopus 로고
    • Evaluation of a lung tumor autocontouring algorithm for intrafractional tumor tracking using low-field MRI: A phantom study
    • 10.1118/1.3685578 0094-2405
    • Yun J, Yip E, Wachowicz K, Rathee S, Mackenzie M, Robinson D and Fallone B G 2012 Evaluation of a lung tumor autocontouring algorithm for intrafractional tumor tracking using low-field MRI: a phantom study Med. Phys. 39 1481-94
    • (2012) Med. Phys. , vol.39 , Issue.3 , pp. 1481-1494
    • Yun, J.1    Yip, E.2    Wachowicz, K.3    Rathee, S.4    MacKenzie, M.5    Robinson, D.6    Fallone, B.G.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.