메뉴 건너뛰기




Volumn 36, Issue 4, 2009, Pages 1061-1073

Adapting liver motion models using a navigator channel technique

Author keywords

deformable registration; finite element model; image guided radiotherapy; intrafraction motion; Navigator channel

Indexed keywords

BIOMECHANICS; COMPUTERIZED TOMOGRAPHY; DEFORMATION; IMAGE ENHANCEMENT; IMAGE SEGMENTATION; POPULATION STATISTICS; RADIOTHERAPY; TUMORS;

EID: 63849198448     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3077923     Document Type: Article
Times cited : (36)

References (41)
  • 1
    • 33748288037 scopus 로고    scopus 로고
    • Assessment of residual error in liver position using kV cone-beam CT for liver cancer high precision radiation therapy
    • M. Hawkins, K. K. Brock, C. Eccles, D. J. Moseley, D. A. Jaffray, and L. A. Dawson, " Assessment of residual error in liver position using kV cone-beam CT for liver cancer high precision radiation therapy.," Int. J. Radiat. Oncol., Biol., Phys. 66 (2), 610-619 (2006).
    • (2006) Int. J. Radiat. Oncol., Biol., Phys. , vol.66 , Issue.2 , pp. 610-619
    • Hawkins, M.1    Brock, K.K.2    Eccles, C.3    Moseley, D.J.4    Jaffray, D.A.5    Dawson, L.A.6
  • 2
    • 0035577652 scopus 로고    scopus 로고
    • The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy
    • 0360-3016 10.1016/S0360-3016(01)02653-0 ().
    • L. A. Dawson, K. K. Brock, S. Kazanjian, D. Fitch, C. J. McGinn, T. S. Lawrence, R. K. Ten Haken, and J. Balter, " The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/S0360-3016(01)02653-0 51 (5), 1410-1421 (2001).
    • (2001) Int. J. Radiat. Oncol., Biol., Phys. , vol.51 , Issue.5 , pp. 1410-1421
    • Dawson, L.A.1    Brock, K.K.2    Kazanjian, S.3    Fitch, D.4    Mcginn, C.J.5    Lawrence, T.S.6    Ten Haken, R.K.7    Balter, J.8
  • 3
    • 31844444644 scopus 로고    scopus 로고
    • Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy
    • 0360-3016 10.1016/j.ijrob2005.05.066 ().
    • C. Eccles, K. K. Brock, J. P. Bissonnette, M. Hawkins, and L. A. Dawson, " Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/j.ijrobp.2005.05.066 64 (3), 751-759 (2006).
    • (2006) Int. J. Radiat. Oncol., Biol., Phys. , vol.64 , Issue.3 , pp. 751-759
    • Eccles, C.1    Brock, K.K.2    Bissonnette, J.P.3    Hawkins, M.4    Dawson, L.A.5
  • 4
    • 0035045155 scopus 로고    scopus 로고
    • Organ/patient geometric variation in external beam radiotherapy and its effects
    • 0094-2405 10.1118/1.1357224.
    • D. Yan and D. Lockman, " Organ/patient geometric variation in external beam radiotherapy and its effects.," Med. Phys. 0094-2405 10.1118/1.1357224 28, 593-602 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 593-602
    • Yan, D.1    Lockman, D.2
  • 5
    • 0033001374 scopus 로고    scopus 로고
    • A model to accumulate fractionated dose in a deforming organ
    • 0360-3016 10.1016/S0360-3016(99)00007-3 ().
    • D. Yan, D. A. Jaffray, and J. W. Wong, " A model to accumulate fractionated dose in a deforming organ.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/S0360-3016(99)00007-3 44 (3), 665-675 (1999).
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.44 , Issue.3 , pp. 665-675
    • Yan, D.1    Jaffray, D.A.2    Wong, J.W.3
  • 6
    • 18944396614 scopus 로고    scopus 로고
    • Narrow band deformable registration of prostate magnetic resonance imaging, magnetic resonance spectroscopic imaging, and computed tomography studies
    • 0360-3016 10.1016/j.ijrob2005.02.001 ().
    • E. Schreibmann and L. Xing, " Narrow band deformable registration of prostate magnetic resonance imaging, magnetic resonance spectroscopic imaging, and computed tomography studies.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/j.ijrobp.2005.02.001 62 (2), 595-605 (2005).
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.62 , Issue.2 , pp. 595-605
    • Schreibmann, E.1    Xing, L.2
  • 7
    • 33645351690 scopus 로고    scopus 로고
    • Image interpolation in 4D CT using a B-Spline deformable registration model
    • 0360-3016 10.1016/j.ijrob2005.11.018 ().
    • E. Schreibmann, G. T. Chen, and L. Xing, " Image interpolation in 4D CT using a B-Spline deformable registration model.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/j.ijrobp.2005.11.018 64 (5), 1537-1550 (2006).
    • (2006) Int. J. Radiat. Oncol., Biol., Phys. , vol.64 , Issue.5 , pp. 1537-1550
    • Schreibmann, E.1    Chen, G.T.2    Xing, L.3
  • 8
    • 33644992060 scopus 로고    scopus 로고
    • Preliminary study on the use of nonrigid registration for thoraco-abdominal radiosurgery
    • 0094-2405 10.1118/1.2103428.
    • J. Stancanello, E. Berna, C. Cavedon, P. Francescon, D. Loeckx, P. Cerveri, G. Ferrigno, and G. Baselli, " Preliminary study on the use of nonrigid registration for thoraco-abdominal radiosurgery.," Med. Phys. 0094-2405 10.1118/1.2103428 32, 3777-3785 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 3777-3785
    • Stancanello, J.1    Berna, E.2    Cavedon, C.3    Francescon, P.4    Loeckx, D.5    Cerveri, P.6    Ferrigno, G.7    Baselli, G.8
  • 9
    • 1642280997 scopus 로고    scopus 로고
    • Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images
    • 0094-2405 10.1118/1.1644513.
    • T. Rohlfing, C. R. Maurer, Jr., W. G. O'Dell, and J. Zhong, " Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images.," Med. Phys. 0094-2405 10.1118/1.1644513 31, 427-432 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 427-432
    • Rohlfing, T.1    Maurer Jr., C.R.2    O'dell, W.G.3    Zhong, J.4
  • 10
    • 79957563017 scopus 로고
    • Principal warps: Thin-plate splines and the decomposition of deformations
    • 0162-8828 10.1109/34.24792.
    • F. L. Bookstein, " Principal warps: Thin-plate splines and the decomposition of deformations.," IEEE Trans. Pattern Anal. Mach. Intell. 0162-8828 10.1109/34.24792 11, 567-585 (1989).
    • (1989) IEEE Trans. Pattern Anal. Mach. Intell. , vol.11 , pp. 567-585
    • Bookstein, F.L.1
  • 11
    • 41449095389 scopus 로고    scopus 로고
    • The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer
    • 0094-2405 10.1118/1.2839095.
    • Q. J. Wu, D. Thongphiew, Z. Wang, V. Chankong, and F. F. Yin, " The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer.," Med. Phys. 0094-2405 10.1118/1.2839095 35, 1440-1451 (2008).
    • (2008) Med. Phys. , vol.35 , pp. 1440-1451
    • Wu, Q.J.1    Thongphiew, D.2    Wang, Z.3    Chankong, V.4    Yin, F.F.5
  • 12
    • 4544350801 scopus 로고    scopus 로고
    • Intrathoracic tumour motion estimation from CT imaging using the 3D optical flow method
    • 0031-9155 10.1088/0031-9155/49/17/022 ().
    • T. Guerrero, G. Zhang, T. C. Huang, and K. P. Lin, " Intrathoracic tumour motion estimation from CT imaging using the 3D optical flow method.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/49/17/022 49 (17), 4147-4161 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , Issue.17 , pp. 4147-4161
    • Guerrero, T.1    Zhang, G.2    Huang, T.C.3    Lin, K.P.4
  • 14
    • 46149110088 scopus 로고    scopus 로고
    • A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map
    • 0094-2405 10.1118/1.2940725.
    • L. Ren, J. Zhang, D. Thongphiew, D. J. Godfrey, Q. J. Wu, S. M. Zhou, and F. F. Yin, " A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map.," Med. Phys. 0094-2405 10.1118/1.2940725 35, 3110-3115 (2008).
    • (2008) Med. Phys. , vol.35 , pp. 3110-3115
    • Ren, L.1    Zhang, J.2    Thongphiew, D.3    Godfrey, D.J.4    Wu, Q.J.5    Zhou, S.M.6    Yin, F.F.7
  • 15
    • 49549087531 scopus 로고    scopus 로고
    • Improving soft-tissue contrast in four-dimensional computed tomography images of liver cancer patients using a deformable image registration method
    • 0094-2405
    • H. Wang, S. Krishnan, X. Wang, A. S. Beddar, T. M. Briere, C. H. Crane, R. Mohan, and L. Dong, " Improving soft-tissue contrast in four-dimensional computed tomography images of liver cancer patients using a deformable image registration method.," Int. J. Radiat. Oncol., Biol., Phys. 72 (1), 201-209 (2008). 0094-2405
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.72 , Issue.1 , pp. 201-209
    • Wang, H.1    Krishnan, S.2    Wang, X.3    Beddar, A.S.4    Briere, T.M.5    Crane, C.H.6    Mohan, R.7    Dong, L.8
  • 16
    • 4344692365 scopus 로고    scopus 로고
    • Fast free-form deformable registration via calculus of variations
    • 0031-9155 10.1088/0031-9155/49/14/003 ().
    • W. Lu, M. L. Chen, G. H. Olivera, K. J. Ruchala, and T. R. Mackie, " Fast free-form deformable registration via calculus of variations.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/49/14/003 49 (14), 3067-3087 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , Issue.14 , pp. 3067-3087
    • Lu, W.1    Chen, M.L.2    Olivera, G.H.3    Ruchala, K.J.4    Mackie, T.R.5
  • 17
    • 33644549665 scopus 로고    scopus 로고
    • Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue
    • 0360-3016 10.1016/j.ijrob2005.10.027 ().
    • K. K. Brock, L. A. Dawson, M. B. Sharpe, D. J. Moseley, and D. A. Jaffray, " Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/j.ijrobp.2005.10.027 64 (4), 1245-1254 (2006).
    • (2006) Int. J. Radiat. Oncol., Biol., Phys. , vol.64 , Issue.4 , pp. 1245-1254
    • Brock, K.K.1    Dawson, L.A.2    Sharpe, M.B.3    Moseley, D.J.4    Jaffray, D.A.5
  • 18
    • 0033744007 scopus 로고    scopus 로고
    • Comparison of rigid and elastic matching of dynamic magnetic resonance mammographic images by mutual information
    • 0094-2405 10.1118/1.1288241.
    • T. Bruckner, R. Lucht, and G. Brix, " Comparison of rigid and elastic matching of dynamic magnetic resonance mammographic images by mutual information.," Med. Phys. 0094-2405 10.1118/1.1288241 27, 2456-2461 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 2456-2461
    • Bruckner, T.1    Lucht, R.2    Brix, G.3
  • 20
    • 21144441919 scopus 로고    scopus 로고
    • Accuracy of finite element model (FEM)-based multi-organ deformable image registration
    • K. K. Brock, M. B. Sharpe, L. A. Dawson, S. M. Kim, and D. A. Jaffray, " Accuracy of finite element model (FEM)-based multi-organ deformable image registration.," Med. Phys. 32 (6), 1647-1659 (2005).
    • (2005) Med. Phys. , vol.32 , Issue.6 , pp. 1647-1659
    • Brock, K.K.1    Sharpe, M.B.2    Dawson, L.A.3    Kim, S.M.4    Jaffray, D.A.5
  • 22
    • 34548354952 scopus 로고    scopus 로고
    • Efficient liver segmentation using a level-set method with optimal detection of the initial liver boundary from level-set speed images
    • 0169-2607
    • J. Lee, N. Kim, H. Lee, J. B. Seo, H. J. Won, Y. M. Shin, Y. G. Shin, and S. H. Kim, " Efficient liver segmentation using a level-set method with optimal detection of the initial liver boundary from level-set speed images.," Comput. Methods Programs Biomed. 88, 26-38 (2007). 0169-2607
    • (2007) Comput. Methods Programs Biomed. , vol.88 , pp. 26-38
    • Lee, J.1    Kim, N.2    Lee, H.3    Seo, J.B.4    Won, H.J.5    Shin, Y.M.6    Shin, Y.G.7    Kim, S.H.8
  • 24
    • 33644992974 scopus 로고    scopus 로고
    • Liver segmentation for CT images using GVF snake
    • 0094-2405 10.1118/1.2132573.
    • F. Liu, B. Zhao, P. K. Kijewski, L. Wang, and L. H. Schwartz, " Liver segmentation for CT images using GVF snake.," Med. Phys. 0094-2405 10.1118/1.2132573 32, 3699-3706 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 3699-3706
    • Liu, F.1    Zhao, B.2    Kijewski, P.K.3    Wang, L.4    Schwartz, L.H.5
  • 25
    • 57649149659 scopus 로고    scopus 로고
    • Fully automatic liver segmentation through graph-cut technique
    • 1557-170X
    • L. Massoptier and S. Casciaro, " Fully automatic liver segmentation through graph-cut technique.," Conf. Proc. IEEE Eng. Med. Biol. Soc. 2007, 5243-5246 (2007). 1557-170X
    • (2007) Conf. Proc. IEEE Eng. Med. Biol. Soc. , vol.2007 , pp. 5243-5246
    • Massoptier, L.1    Casciaro, S.2
  • 27
    • 0037941644 scopus 로고    scopus 로고
    • Construction of an abdominal probabilistic atlas and its application in segmentation
    • 0278-0062 10.1109/TMI.2003.809139.
    • H. Park, P. H. Bland, and C. R. Meyer, " Construction of an abdominal probabilistic atlas and its application in segmentation.," IEEE Trans. Med. Imaging 0278-0062 10.1109/TMI.2003.809139 22, 483-492 (2003).
    • (2003) IEEE Trans. Med. Imaging , vol.22 , pp. 483-492
    • Park, H.1    Bland, P.H.2    Meyer, C.R.3
  • 28
    • 16344366951 scopus 로고    scopus 로고
    • Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion
    • 0360-3016 10.1016/j.ijrob2004.11.037 ().
    • E. Rietzel, G. T. Chen, N. C. Choi, and C. G. Willet, " Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/j.ijrobp.2004.11.037 61 (5), 1535-1550 (2005).
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.61 , Issue.5 , pp. 1535-1550
    • Rietzel, E.1    Chen, G.T.2    Choi, N.C.3    Willet, C.G.4
  • 29
    • 45849148032 scopus 로고    scopus 로고
    • Patient oriented and robust automatic liver segmentation for pre-evaluation of liver transplantation
    • 0010-4825
    • M. A. Selver, A. Kocaoglu, G. K. Demir, H. Dogan, O. Dicle, and C. Guzelis, " Patient oriented and robust automatic liver segmentation for pre-evaluation of liver transplantation.," Comput. Biol. Med. 38, 765-784 (2008). 0010-4825
    • (2008) Comput. Biol. Med. , vol.38 , pp. 765-784
    • Selver, M.A.1    Kocaoglu, A.2    Demir, G.K.3    Dogan, H.4    Dicle, O.5    Guzelis, C.6
  • 33
    • 21244477043 scopus 로고    scopus 로고
    • Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control
    • 0360-3016 10.1016/j.ijrob2005.03.072 ().
    • L. A. Dawson, C. Eccles, J. P. Bissonnette, and K. K. Brock, " Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/j.ijrobp.2005.03.072 62 (4), 1247-1252 (2005).
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.62 , Issue.4 , pp. 1247-1252
    • Dawson, L.A.1    Eccles, C.2    Bissonnette, J.P.3    Brock, K.K.4
  • 34
    • 0033977805 scopus 로고    scopus 로고
    • Extracranial stereotactic radiation therapy: Set-up accuracy of patients treated for liver metastases
    • 0360-3016 10.1016/S0360-3016(99)00413-7 ().
    • K. K. Herfarth, J. Debus, F. Lohr, M. L. Bahner, P. Fritz, A. Hoss, W. Schlegel, and M. F. Wannenmacher, " Extracranial stereotactic radiation therapy: Set-up accuracy of patients treated for liver metastases.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/S0360-3016(99)00413-7 46 (2), 329-335 (2000).
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.46 , Issue.2 , pp. 329-335
    • Herfarth, K.K.1    Debus, J.2    Lohr, F.3    Bahner, M.L.4    Fritz, P.5    Hoss, A.6    Schlegel, W.7    Wannenmacher, M.F.8
  • 35
    • 34247513428 scopus 로고    scopus 로고
    • Frame-based immobilization and targeting for stereotactic body radiation therapy
    • B. Murray, K. Forster, and R. Timmerman, " Frame-based immobilization and targeting for stereotactic body radiation therapy.," Med. Dosim. 32, 86-91 (2007).
    • (2007) Med. Dosim. , vol.32 , pp. 86-91
    • Murray, B.1    Forster, K.2    Timmerman, R.3
  • 37
    • 0034084842 scopus 로고    scopus 로고
    • Tissue characterization using magnetic resonance elastography: Preliminary results
    • 0031-9155 10.1088/0031-9155/45/6/313.
    • S. A. Kruse, J. A. Smith, A. J. Lawrence, M. A. Dresner, A. Manduca, J. F. Greenleaf, and R. L. Ehman, " Tissue characterization using magnetic resonance elastography: Preliminary results.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/45/6/313 45, 1579-1590 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 1579-1590
    • Kruse, S.A.1    Smith, J.A.2    Lawrence, A.J.3    Dresner, M.A.4    Manduca, A.5    Greenleaf, J.F.6    Ehman, R.L.7
  • 39
    • 43449120877 scopus 로고    scopus 로고
    • A multi-institution deformable registration accuracy study
    • Deformable Registration Accuracy Consortium, "," 0360-3016 10.1016/j.ijrob2007.07.081 ().
    • K. K. Brock and Deformable Registration Accuracy Consortium, " A multi-institution deformable registration accuracy study.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/j.ijrobp.2007.07.081 69 (3), S44 (2007).
    • (2007) Int. J. Radiat. Oncol., Biol., Phys. , vol.69 , Issue.3 , pp. 44
    • Brock, K.K.1
  • 41
    • 34547539856 scopus 로고    scopus 로고
    • Three dimensional motion of liver tumours using cine MRI compared to liver motion assessed at fluoroscopy
    • 1748-717X
    • L. A. Dawson, C. Eccles, A. Kirilova, and K. K. Brock, " Three dimensional motion of liver tumours using cine MRI compared to liver motion assessed at fluoroscopy.," Radiat. Oncol. A483, S214 (2004). 1748-717X
    • (2004) Radiat. Oncol. , vol.483 , pp. 214
    • Dawson, L.A.1    Eccles, C.2    Kirilova, A.3    Brock, K.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.