메뉴 건너뛰기




Volumn 79, Issue 1, 2011, Pages 269-278

Real-time target position estimation using stereoscopic kilovoltage/megavoltage imaging and external respiratory monitoring for dynamic multileaf collimator tracking

Author keywords

dynamic multileaf collimator; external respiratory surrogate; Real time tumor tracking; respiratory tumor motion; x ray image guidance

Indexed keywords

DYNAMIC MULTILEAF COLLIMATORS; EXTERNAL RESPIRATORY SURROGATE; REAL-TIME TUMOR TRACKING; RESPIRATORY TUMOR MOTION; X-RAY IMAGE;

EID: 78650024202     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2010.02.052     Document Type: Article
Times cited : (43)

References (18)
  • 1
    • 67049086549 scopus 로고    scopus 로고
    • First Demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking
    • B. Cho, P.R. Poulsen, and A. Sloutsky First Demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking Int J Radiat Oncol Biol Phys 74 2009 859 867
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , pp. 859-867
    • Cho, B.1    Poulsen, P.R.2    Sloutsky, A.3
  • 2
    • 41449112602 scopus 로고    scopus 로고
    • Combined kV and MV imaging for real-time tracking of implanted fiducial markers
    • R.D. Wiersma, W.H. Mao, and L. Xing Combined kV and MV imaging for real-time tracking of implanted fiducial markers Med Phys 35 2008 1191 1198
    • (2008) Med Phys , vol.35 , pp. 1191-1198
    • Wiersma, R.D.1    Mao, W.H.2    Xing, L.3
  • 3
    • 78649986980 scopus 로고    scopus 로고
    • Dynamic MLC tracking of respiratory target motion based on a single kilovoltage imager during arc radiotherapy
    • P.R. Poulsen, B. Cho, and D. Ruan Dynamic MLC tracking of respiratory target motion based on a single kilovoltage imager during arc radiotherapy Int J Radiat Oncol Biol Phys 74 2009 868 875
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , pp. 868-875
    • Poulsen, P.R.1    Cho, B.2    Ruan, D.3
  • 4
    • 7244242297 scopus 로고    scopus 로고
    • Respiration tracking in radiosurgery
    • A. Schweikard, H. Shiomi, and J. Adler Respiration tracking in radiosurgery Med Phys 31 2004 2738 2741
    • (2004) Med Phys , vol.31 , pp. 2738-2741
    • Schweikard, A.1    Shiomi, H.2    Adler, J.3
  • 5
    • 65449142560 scopus 로고    scopus 로고
    • Use of the 4D phantom to test real-time targeted radiation therapy device accuracy
    • K. Malinowski, K. Lechleiter, and J. Hubenschmidt Use of the 4D phantom to test real-time targeted radiation therapy device accuracy Med Phys 34 2007 2611-2611
    • (2007) Med Phys , vol.34
    • Malinowski, K.1    Lechleiter, K.2    Hubenschmidt, J.3
  • 6
    • 42949109604 scopus 로고    scopus 로고
    • Management of three-dimensional intrafraction motion through real-time DMLC tracking
    • A. Sawant, R. Venkat, and V. Srivastava Management of three-dimensional intrafraction motion through real-time DMLC tracking Med Phys 35 2008 2050 2061
    • (2008) Med Phys , vol.35 , pp. 2050-2061
    • Sawant, A.1    Venkat, R.2    Srivastava, V.3
  • 7
    • 45749140404 scopus 로고    scopus 로고
    • Inference of hysteretic respiratory tumor motion from external surrogates: A state augmentation approach
    • D. Ruan, J.A. Fessler, and J.M. Balter Inference of hysteretic respiratory tumor motion from external surrogates: A state augmentation approach Phys Med Biol 53 2008 2923 2936
    • (2008) Phys Med Biol , vol.53 , pp. 2923-2936
    • Ruan, D.1    Fessler, J.A.2    Balter, J.M.3
  • 8
    • 33748576243 scopus 로고    scopus 로고
    • Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system
    • P.J. Keall, H. Cattell, and D. Pokhrel Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system Int J Radiat Oncol Biol Phys 65 2006 1579 1584
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 1579-1584
    • Keall, P.J.1    Cattell, H.2    Pokhrel, D.3
  • 9
    • 42949151038 scopus 로고    scopus 로고
    • Accurate prediction of intra-fraction motion using a modified linear adaptive filter
    • V. Srivastava, P. Keall, and A. Sawant Accurate prediction of intra-fraction motion using a modified linear adaptive filter Med Phys 34 2007 2546-2546
    • (2007) Med Phys , vol.34
    • Srivastava, V.1    Keall, P.2    Sawant, A.3
  • 10
    • 47649126554 scopus 로고    scopus 로고
    • An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients
    • Y. Suh, S. Dieterich, and B. Cho An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients Phys Med Biol 53 2008 3623 3640
    • (2008) Phys Med Biol , vol.53 , pp. 3623-3640
    • Suh, Y.1    Dieterich, S.2    Cho, B.3
  • 11
    • 45749084084 scopus 로고    scopus 로고
    • A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoring
    • B.C. Cho, Y.L. Suh, and S. Dieterich A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoring Phys Med Biol 53 2008 2837 2855
    • (2008) Phys Med Biol , vol.53 , pp. 2837-2855
    • Cho, B.C.1    Suh, Y.L.2    Dieterich, S.3
  • 12
    • 64049103804 scopus 로고    scopus 로고
    • Clinical accuracy of the respiratory tumor tracking system of the Cyberknife: Assessment by analysis of log files
    • M. Hoogeman, J.B. Prevost, and J. Nuyttens Clinical accuracy of the respiratory tumor tracking system of the Cyberknife: Assessment by analysis of log files Int J Radiat Oncol Biol Phys 74 2009 297 303
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , pp. 297-303
    • Hoogeman, M.1    Prevost, J.B.2    Nuyttens, J.3
  • 13
    • 66449122447 scopus 로고    scopus 로고
    • Four-dimensional inverse treatment planning with inclusion of implanted fiducials in IMRT segmented fields
    • Y.Z. Ma, L. Lee, and O. Keshet Four-dimensional inverse treatment planning with inclusion of implanted fiducials in IMRT segmented fields Med Phys 36 2009 2215 2221
    • (2009) Med Phys , vol.36 , pp. 2215-2221
    • Ma, Y.Z.1    Lee, L.2    Keshet, O.3
  • 14
    • 78650012111 scopus 로고    scopus 로고
    • DMLC Tracking with real-time target position estimation combining a single kV imager and an optical respiratory monitoring system
    • B. Cho, P. Poulsen, and D. Ruan DMLC Tracking with real-time target position estimation combining a single kV imager and an optical respiratory monitoring system Int J Radiat Oncol Biol Phys 2009 Suppl:ASTRO2009 presentation
    • (2009) Int J Radiat Oncol Biol Phys
    • Cho, B.1    Poulsen, P.2    Ruan, D.3
  • 15
    • 17844379267 scopus 로고    scopus 로고
    • Determination of maximum leaf velocity and acceleration of a dynamic multileaf collimator: Implications for 4D radiotherapy
    • K. Wijesooriya, C. Bartee, and J.V. Siebers Determination of maximum leaf velocity and acceleration of a dynamic multileaf collimator: Implications for 4D radiotherapy Med Phys 32 2005 932 941
    • (2005) Med Phys , vol.32 , pp. 932-941
    • Wijesooriya, K.1    Bartee, C.2    Siebers, J.V.3
  • 16
    • 33748305705 scopus 로고    scopus 로고
    • Evaluation of an infrared camera and x-ray system using implanted fiducials in patients with lung tumors for gated radiation therapy
    • T.R. Willoughby, A.R. Forbes, and D. Buchholz Evaluation of an infrared camera and x-ray system using implanted fiducials in patients with lung tumors for gated radiation therapy Int J Radiat Oncol Biol Phys 66 2006 568 575
    • (2006) Int J Radiat Oncol Biol Phys , vol.66 , pp. 568-575
    • Willoughby, T.R.1    Forbes, A.R.2    Buchholz, D.3
  • 17
    • 25644432884 scopus 로고    scopus 로고
    • A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup
    • C. Bert, K.G. Metheany, and K. Doppke A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup Med Phys 32 2005 2753 2762
    • (2005) Med Phys , vol.32 , pp. 2753-2762
    • Bert, C.1    Metheany, K.G.2    Doppke, K.3
  • 18
    • 38149078236 scopus 로고    scopus 로고
    • Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance
    • S.S. Korreman, T. Juhler-Nottrup, and A.L. Boyer Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance Radiother Oncol 86 2008 61 68
    • (2008) Radiother Oncol , vol.86 , pp. 61-68
    • Korreman, S.S.1    Juhler-Nottrup, T.2    Boyer, A.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.