Independent verification of gantry angle for pre-treatment VMAT QA using EPID

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRONIC PORTAL IMAGING DEVICES; GANTRY ANGLES; MULTILEAF COLLIMATORS; PIXEL LINEARITY; PRE-TREATMENT; TREATMENT PLANNING; TREATMENT PLANS; VOLUMETRIC MODULATED ARC THERAPY;

EID: 84867244530     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/57/20/6587     Document Type: Article
Times cited : (19)

References (13)
  • 1
    • 78650580139 scopus 로고    scopus 로고
    • An evaluation of cine-mode 3D portal image dosimetry for volumetric modulated arc therapy
    • 1742-6596 012022
    • Ansbacher W, Swift C-L and Greer P B 2010 An evaluation of cine-mode 3D portal image dosimetry for volumetric modulated arc therapy J. Phys.: Conf. Ser. 250 012022
    • (2010) J. Phys.: Conf. Ser. , vol.250 , Issue.1
    • Ansbacher, W.1    Swift, C.-L.2    Greer, P.B.3
  • 3
    • 10744231470 scopus 로고    scopus 로고
    • Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee
    • DOI 10.1118/1.1591194
    • Ezzell G A, Galvin J M, Low D, Palta J R, Rosen I, Sharpe M B, Xia P, Xiao Y, Xing L and Yu C X 2003 Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT subcommittee of the AAPM radiation therapy committee Med. Phys. 30 2089-115 (Pubitemid 37022015)
    • (2003) Medical Physics , vol.30 , Issue.8 , pp. 2089-2115
    • Ezzell, G.A.1    Galvin, J.M.2    Low, D.3    Palta, J.R.4    Rosen, I.5    Sharpe, M.B.6    Xia, P.7    Xiao, Y.8    Xing, L.9    Yu, C.X.10
  • 4
    • 34347388219 scopus 로고    scopus 로고
    • IMAT-SIM: A new method for the clinical dosimetry of intensity-modulated arc therapy (IMAT)
    • DOI 10.1118/1.2739807
    • Iori M, Cagni E, Nahum A E and Borasi G 2007 IMAT-SIM: a new method for the clinical dosimetry of intensity-modulated arc therapy (IMAT) Med. Phys. 34 2759-73 (Pubitemid 47019796)
    • (2007) Medical Physics , vol.34 , Issue.7 , pp. 2759-2773
    • Iori, M.1    Cagni, E.2    Nahum, A.E.3    Borasi, G.4
  • 5
    • 73649128290 scopus 로고    scopus 로고
    • Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool
    • 10.1118/1.3271107 0094-2405
    • Iori M, Cagni E, Paiusco M, Munro P and Nahum A E 2010 Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool Med. Phys. 37 377-90
    • (2010) Med. Phys. , vol.37 , Issue.1 , pp. 377-390
    • Iori, M.1    Cagni, E.2    Paiusco, M.3    Munro, P.4    Nahum, A.E.5
  • 6
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • DOI 10.1118/1.598248
    • Low D A, Harms W B, Mutic S and Purdy J A 1998 A technique for the quantitative evaluation of dose distributions Med. Phys. 25 656-61 (Pubitemid 28234885)
    • (1998) Medical Physics , vol.25 , Issue.5 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 8
    • 41449117460 scopus 로고    scopus 로고
    • Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems
    • DOI 10.1118/1.2885719
    • Mao W, Lee L and Xing L 2008 Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems Med. Phys. 35 1497-506 (Pubitemid 351457518)
    • (2008) Medical Physics , vol.35 , Issue.4 , pp. 1497-1506
    • Mao, W.1    Lee, L.2    Xing, L.3
  • 9
    • 67649622802 scopus 로고    scopus 로고
    • Dosimetric properties of an amorphous-silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT
    • 10.1118/1.3148822 0094-2405
    • McCurdy B M and Greer P B 2009 Dosimetric properties of an amorphous-silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT Med. Phys. 36 3028-39
    • (2009) Med. Phys. , vol.36 , Issue.7 , pp. 3028-3039
    • McCurdy, B.M.1    Greer, P.B.2
  • 10
    • 53149135069 scopus 로고    scopus 로고
    • The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy
    • 10.1186/1748-717X-3-24 1748-717X
    • Nicolini G, Vanetti E, Clivio A, Fogliata A, Korreman S, Bocanek J and Cozzi L 2008 The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy Radiat. Oncol. 3 24
    • (2008) Radiat. Oncol. , vol.3 , Issue.1 , pp. 24
    • Nicolini, G.1    Vanetti, E.2    Clivio, A.3    Fogliata, A.4    Korreman, S.5    Bocanek, J.6    Cozzi, L.7
  • 11
    • 44449088459 scopus 로고    scopus 로고
    • An EPID response calculation algorithm using spatial beam characteristics of primary, head scattered and MLC transmitted radiation
    • DOI 10.1118/1.2911870
    • Rosca F and Zygmanski P 2008 An EPID response calculation algorithm using spatial beam characteristics of primary, head scattered and MLC transmitted radiation Med. Phys. 35 2224-34 (Pubitemid 351752942)
    • (2008) Medical Physics , vol.35 , Issue.6 , pp. 2224-2234
    • Rosca, F.1    Zygmanski, P.2
  • 12
    • 1942478371 scopus 로고    scopus 로고
    • The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields
    • DOI 10.1016/j.radonc.2004.02.018, PII S016781400400088X
    • Van Esch A, Depuydt T and Huyskens D P 2004 The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields Radiother. Oncol. 71 223-34 (Pubitemid 38521192)
    • (2004) Radiotherapy and Oncology , vol.71 , Issue.2 , pp. 223-234
    • Van Esch, A.1    Depuydt, T.2    Huyskens, D.P.3
  • 13
    • 0347625746 scopus 로고    scopus 로고
    • Dosimetric IMRT verification with a flat-panel EPID
    • DOI 10.1118/1.1625440
    • Warkentin B, Steciw S, Rathee S and Fallone B G 2003 Dosimetric IMRT verification with a flat-panel EPID Med. Phys. 30 3143-55 (Pubitemid 37553755)
    • (2003) Medical Physics , vol.30 , Issue.12 , pp. 3143-3155
    • Warkentin, B.1    Steciw, S.2    Rathee, S.3    Fallone, B.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.