메뉴 건너뛰기




Volumn 5, Issue 2, 2012, Pages 87-100

Modification of a previously published HPLC-UV method for metformin determination, validation and application to test bioequivalence

Author keywords

Bioequivalence; HPLC UV; Human plasma; Metformin; Protein precipitation

Indexed keywords

ACETONITRILE; ATENOLOL; DICHLOROMETHANE; GLYSTOR; HYDROCHLORIC ACID; METFORMIN; PHOSPHATE; SILICON DIOXIDE; UNCLASSIFIED DRUG;

EID: 84867021689     PISSN: 19957157     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (33)
  • 1
    • 1342285640 scopus 로고    scopus 로고
    • Rapid determination of metformin in human plasma by liquid chromatographytandem mass spectrometry method
    • Chen X., Gu Q., Qiu F. and Zhong D. Rapid determination of metformin in human plasma by liquid chromatographytandem mass spectrometry method. Journal of Chromatography B. 2004; 802:l377-381.
    • (2004) Journal of Chromatography B , vol.802
    • Chen, X.1    Gu, Q.2    Qiu, F.3    Zhong, D.4
  • 2
    • 84866974857 scopus 로고    scopus 로고
    • Accessed 27 Sept 2011
    • http://www.rxlist.com/glucophage-drug.htm. Accessed 27 Sept 2011.
  • 4
    • 15944389510 scopus 로고    scopus 로고
    • The development and validation of liquid chromatography method for the simultaneous determination of metformin and glipizide, gliclazide, glibenclamide or glimperide in plasma
    • AbuRuz S., Millership J. and McElnay J. The development and validation of liquid chromatography method for the simultaneous determination of metformin and glipizide, gliclazide, glibenclamide or glimperide in plasma. Journal of Chromatography B. 2005; 817:277-286.
    • (2005) Journal of Chromatography B , vol.817 , pp. 277-286
    • Aburuz, S.1    Millership, J.2    McElnay, J.3
  • 5
    • 78751631441 scopus 로고    scopus 로고
    • Simultaneous determination and pharmacokinetic study of metformin and rosiglitazone in human plasma by HPLC-ESI-MS
    • Chen L., Zhou Z., Shen M. and Ma A. Simultaneous determination and pharmacokinetic study of metformin and rosiglitazone in human plasma by HPLC-ESI-MS. Journal of Chromatographic Science. 2011; 49:94-100.
    • (2011) Journal of Chromatographic Science , vol.49 , pp. 94-100
    • Chen, L.1    Zhou, Z.2    Shen, M.3    Ma, A.4
  • 6
    • 79953216324 scopus 로고    scopus 로고
    • Simultaneous quantitation of metformin and sitagliptin from mouse and human dried blood spots using laser diode thermal desorption tandem mass spectrometry
    • Swales J.G., Gallaher R.T., Denn M. and Peter R.M. Simultaneous quantitation of metformin and sitagliptin from mouse and human dried blood spots using laser diode thermal desorption tandem mass spectrometry. Journal of Pharmaceutical and Biomedical Analysis. 2011; 55:544-551.
    • (2011) Journal of Pharmaceutical and Biomedical Analysis , vol.55 , pp. 544-551
    • Swales, J.G.1    Gallaher, R.T.2    Denn, M.3    Peter, R.M.4
  • 8
    • 0032511210 scopus 로고    scopus 로고
    • Simple high-performance liquid chromatographic method for the determination of metformin in human plasma
    • Yuen K. and Peh K. Simple high-performance liquid chromatographic method for the determination of metformin in human plasma. Journal of Chromatography B. 1998; 710:243-246.
    • (1998) Journal of Chromatography B , vol.710 , pp. 243-246
    • Yuen, K.1    Peh, K.2
  • 10
    • 0032566777 scopus 로고    scopus 로고
    • Determination of metformin in plasma by high-performance liquid chromatography after ultrafiltration
    • Vesterqvist O., Nabbie F. and Swanson B. Determination of metformin in plasma by high-performance liquid chromatography after ultrafiltration. Journal of Chromatography B. 1998; 716:299-304.
    • (1998) Journal of Chromatography B , vol.716 , pp. 299-304
    • Vesterqvist, O.1    Nabbie, F.2    Swanson, B.3
  • 11
    • 0019468975 scopus 로고
    • Rapid Liquid-Chromatographic Determination of Metformin in Plasma and Urine
    • Charles B.G., Jacobsen N.W. and Ravenscroft P.J. Rapid Liquid-Chromatographic Determination of Metformin in Plasma and Urine. Clinical Chemistry. 1981; 27:434-436.
    • (1981) Clinical Chemistry , vol.27 , pp. 434-436
    • Charles, B.G.1    Jacobsen, N.W.2    Ravenscroft, P.J.3
  • 13
    • 0036162447 scopus 로고    scopus 로고
    • Rapid and simple high-performance liquid chromatographic assay for the determination of metformin in human plasma and breast milk
    • Zhang M., Moore G., Lever M., Gardiner S., Kirkpatrick C. and Begg E. Rapid and simple high-performance liquid chromatographic assay for the determination of metformin in human plasma and breast milk. Journal of Chromatography B. 2001; 766:175-179.
    • (2001) Journal of Chromatography B , vol.766 , pp. 175-179
    • Zhang, M.1    Moore, G.2    Lever, M.3    Gardiner, S.4    Kirkpatrick, C.5    Begg, E.6
  • 14
    • 0035144330 scopus 로고    scopus 로고
    • HPLCDAD determination of metformin in human plasma using derivatization with p-nitrobenzoyl chloride in a biphasic system
    • Tache F., David V., Farca A. and Medvedovici A. HPLCDAD determination of metformin in human plasma using derivatization with p-nitrobenzoyl chloride in a biphasic system. Microchemical Journal. 2001; 68:13-19.
    • (2001) Microchemical Journal , vol.68 , pp. 13-19
    • Tache, F.1    David, V.2    Farca, A.3    Medvedovici, A.4
  • 15
    • 24044528546 scopus 로고    scopus 로고
    • Determination of metformin in human plasma by high-performance liquid chromatography
    • Amini H., Ahmadiani A. and Gazerani P. Determination of metformin in human plasma by high-performance liquid chromatography. Journal of Chromatography B. 2005; 824:319-322.
    • (2005) Journal of Chromatography B , vol.824 , pp. 319-322
    • Amini, H.1    Ahmadiani, A.2    Gazerani, P.3
  • 16
    • 78650381848 scopus 로고    scopus 로고
    • Determination of Metformin in Human Plasma and Urine by High-Performance Liquid Chromatography Using Small Sample Volume and Conventional Octadecyl Silane Column
    • Gabr R.Q., Padwal R.S. and Brocks D.R. Determination of Metformin in Human Plasma and Urine by High-Performance Liquid Chromatography Using Small Sample Volume and Conventional Octadecyl Silane Column. Journal Pharmacy and Pharmaceutical Sciences. 2010; 13:486-494.
    • (2010) Journal Pharmacy and Pharmaceutical Sciences , vol.13 , pp. 486-494
    • Gabr, R.Q.1    Padwal, R.S.2    Brocks, D.R.3
  • 17
    • 0344413692 scopus 로고    scopus 로고
    • Determination of metformin in plasma using a new ion pair solid phase extraction technique and ion pair liquid chromatography
    • Abu Ruz S., Millership J. and McElnay J. Determination of metformin in plasma using a new ion pair solid phase extraction technique and ion pair liquid chromatography. Journal of Chromatography B. 2003; 798:203-209.
    • (2003) Journal of Chromatography B , vol.798 , pp. 203-209
    • Abu-Ruz, S.1    Millership, J.2    McElnay, J.3
  • 18
    • 0035812998 scopus 로고    scopus 로고
    • Determination of metformin in human plasma by high-performance liquid chromatography with spectrophotometric detection
    • Cheng C.L. and Chou C.H. Determination of metformin in human plasma by high-performance liquid chromatography with spectrophotometric detection. Journal of Chromatography B. 2001; 762:51-58.
    • (2001) Journal of Chromatography B , vol.762 , pp. 51-58
    • Cheng, C.L.1    Chou, C.H.2
  • 19
    • 0003484310 scopus 로고    scopus 로고
    • CDER, Food and Drug Administration, U.S. Department of Health and Human Services
    • CDER, Food and Drug Administration, U.S. Department of Health and Human Services, Guidance for Industry; Bioanalytical Method Validation, 2001.
    • (2001) Guidance For Industry; Bioanalytical Method Validation
  • 21
    • 84867010973 scopus 로고    scopus 로고
    • ICH Harmonized Tripartite Guideline-Guideline for Good Clinical Practice-Recommended for Adoption at Step 4 of the ICH Process on 1 May 1996 by the ICH Steering Committee
    • ICH Harmonized Tripartite Guideline-Guideline for Good Clinical Practice-Recommended for Adoption at Step 4 of the ICH Process on 1 May 1996 by the ICH Steering Committee.
  • 23
    • 34249744487 scopus 로고    scopus 로고
    • Simple and rapid method determination for metformin in human plasma using high performance liquid chromatography tandem mass spectrometry: Application to pharmacokinetic studies
    • Marques M., Soares A., Pinto O., Werneck-Barroso P., Pinto D., Ferreira-Filho M. and Werneck-Barroso E. Simple and rapid method determination for metformin in human plasma using high performance liquid chromatography tandem mass spectrometry: application to pharmacokinetic studies. Journal of Chromatography B. 2007; 852:308-316.
    • (2007) Journal of Chromatography B , vol.852 , pp. 308-316
    • Marques, M.1    Soares, A.2    Pinto, O.3    Werneck-Barroso, P.4    Pinto, D.5    Ferreira-Filho, M.6    Werneck-Barroso, E.7
  • 24
    • 3242724077 scopus 로고    scopus 로고
    • Rapid and sensitive liquid chromatography-tandem mass spectrophotometric method for the quantitation of metformin in human plasma
    • Wang Y., Tang Y., Gu J., Fawcett J. and Bai X. Rapid and sensitive liquid chromatography-tandem mass spectrophotometric method for the quantitation of metformin in human plasma. Journal of Chromatography B. 2004; 808:215-219.
    • (2004) Journal of Chromatography B , vol.808 , pp. 215-219
    • Wang, Y.1    Tang, Y.2    Gu, J.3    Fawcett, J.4    Bai, X.5
  • 25
    • 33745977360 scopus 로고    scopus 로고
    • Determination of metformin in human plasma using normal phase high performance liquid chromatography
    • Qaisi A., Tutunji M. and Sahouri C. Determination of metformin in human plasma using normal phase high performance liquid chromatography. Saudi Pharmaceutical Journal. 2006; 14:108-114.
    • (2006) Saudi Pharmaceutical Journal , vol.14 , pp. 108-114
    • Qaisi, A.1    Tutunji, M.2    Sahouri, C.3
  • 26
    • 1542302510 scopus 로고    scopus 로고
    • Fast liquid chromatographictandem mass spectrometric (LC-MS-MS) determination of metformin in plasma samples
    • Heinig K. and Bucheli F. Fast liquid chromatographictandem mass spectrometric (LC-MS-MS) determination of metformin in plasma samples. Journal of Pharmaceutical and Biomedical Analysis. 2004; 34:1005-1011.
    • (2004) Journal of Pharmaceutical and Biomedical Analysis , vol.34 , pp. 1005-1011
    • Heinig, K.1    Bucheli, F.2
  • 30
    • 77951567151 scopus 로고    scopus 로고
    • Comparison of a LC/MS method with a LC/UV method for the determination of metformin in plasma samples
    • Georgiţǎ C., Sora I., Albu F. and Monciu C. Comparison of a LC/MS method with a LC/UV method for the determination of metformin in plasma samples. FARMACIA. 2010; 58:158-169.
    • (2010) FARMACIA , vol.58 , pp. 158-169
    • Georgiţǎ, C.1    Sora, I.2    Albu, F.3    Monciu, C.4
  • 31
    • 2942529161 scopus 로고    scopus 로고
    • Biowaiver extension potential to BCS Class III high solubility-low permeability drugs: Bridging evidence for metformin immediate-release tablet
    • Cheng C., Yu L., Lee H.L., Yang C.Y., Lue C.S. and Chou C.H. Biowaiver extension potential to BCS Class III high solubility-low permeability drugs: bridging evidence for metformin immediate-release tablet. European Journal of Pharmaceutical Sciences. 2004; 22:297-304.
    • (2004) European Journal of Pharmaceutical Sciences , vol.22 , pp. 297-304
    • Cheng, C.1    Yu, L.2    Lee, H.L.3    Yang, C.Y.4    Lue, C.S.5    Chou, C.H.6
  • 32
    • 62749163045 scopus 로고    scopus 로고
    • CE with direct sample injection for the determination of metformin in plasma for type 2 diabetic mellitus: An adequate alternative to HPLC
    • Wei S.Y., Yeh H.H., Liao F.F. and Chen S.H. CE with direct sample injection for the determination of metformin in plasma for type 2 diabetic mellitus: An adequate alternative to HPLC. Journal of Separation Science. 2009; 32:413-421.
    • (2009) Journal of Separation Science , vol.32 , pp. 413-421
    • Wei, S.Y.1    Yeh, H.H.2    Liao, F.F.3    Chen, S.H.4
  • 33
    • 0003646348 scopus 로고
    • CDER, Food and Drug Administration, U.S. Department of Health and Human Services
    • CDER, Food and Drug Administration, U.S. Department of Health and Human Services, Reviewer Guidance: Validation of Chromatographic Methods. 1994.
    • (1994) Reviewer Guidance: Validation of Chromatographic Methods


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.