메뉴 건너뛰기




Volumn 67, Issue 11, 2012, Pages 1083-1088

Accuracy of high-pitch prospectively ECG-triggering CT coronary angiography for assessment of stenosis in 103 patients: Comparison with invasive coronary angiography

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; CORONARY ARTERY OBSTRUCTION; DIAGNOSTIC ACCURACY; FEMALE; HEART RATE; HUMAN; IMAGE QUALITY; INTERMETHOD COMPARISON; INVASIVE CORONARY ANGIOGRAPHY; INVASIVE PROCEDURE; MAJOR CLINICAL STUDY; MALE; PREDICTIVE VALUE; PRIORITY JOURNAL; PROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY;

EID: 84867007799     PISSN: 00099260     EISSN: 1365229X     Source Type: Journal    
DOI: 10.1016/j.crad.2012.03.016     Document Type: Article
Times cited : (14)

References (30)
  • 1
    • 10744227989 scopus 로고    scopus 로고
    • Noninvasive assessment of coronary artery disease by multislice spiral computed tomography using a new retrospectively ECG-gated image reconstruction technique
    • Y. Sato, N. Matsumoto, and M. Kato Noninvasive assessment of coronary artery disease by multislice spiral computed tomography using a new retrospectively ECG-gated image reconstruction technique Circ J 67 2003 401 405
    • (2003) Circ J , vol.67 , pp. 401-405
    • Sato, Y.1    Matsumoto, N.2    Kato, M.3
  • 2
    • 11144247393 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution
    • A. Kuettner, T. Beck, and T. Drosch Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution J Am Coll Cardiol 45 2005 123 127
    • (2005) J Am Coll Cardiol , vol.45 , pp. 123-127
    • Kuettner, A.1    Beck, T.2    Drosch, T.3
  • 3
    • 33846219116 scopus 로고    scopus 로고
    • Coronary artery stenosis quantification using multislice computed tomography
    • M. Dewey, W. Rutsch, and D. Schnapauff Coronary artery stenosis quantification using multislice computed tomography Invest Radiol 42 2007 78 84
    • (2007) Invest Radiol , vol.42 , pp. 78-84
    • Dewey, M.1    Rutsch, W.2    Schnapauff, D.3
  • 4
    • 65649137295 scopus 로고    scopus 로고
    • Diagnostic accuracy of angiographic view image for the detection of coronary artery stenoses by 64-detector row CT: A pilot study comparison with conventional post-processing methods and axial images alone
    • M. Jinzaki, K. Sato, and Y. Tanami Diagnostic accuracy of angiographic view image for the detection of coronary artery stenoses by 64-detector row CT: a pilot study comparison with conventional post-processing methods and axial images alone Circ J 73 2009 691 698
    • (2009) Circ J , vol.73 , pp. 691-698
    • Jinzaki, M.1    Sato, K.2    Tanami, Y.3
  • 5
    • 26844549564 scopus 로고    scopus 로고
    • High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography
    • N.R. Mollet, F. Cademartiri, and C.A. van Mieghem High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography Circulation 112 2005 2318 2323
    • (2005) Circulation , vol.112 , pp. 2318-2323
    • Mollet, N.R.1    Cademartiri, F.2    Van Mieghem, C.A.3
  • 6
    • 54549122949 scopus 로고    scopus 로고
    • Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: Results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial
    • M.J. Budoff, D. Dowe, and J.G. Jollis Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial J Am Coll Cardiol 52 2008 1724 1732
    • (2008) J Am Coll Cardiol , vol.52 , pp. 1724-1732
    • Budoff, M.J.1    Dowe, D.2    Jollis, J.G.3
  • 7
    • 34447558140 scopus 로고    scopus 로고
    • Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    • A.J. Einstein, M.J. Henzlova, and S. Rajagopalan Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography JAMA 298 2007 317 323
    • (2007) JAMA , vol.298 , pp. 317-323
    • Einstein, A.J.1    Henzlova, M.J.2    Rajagopalan, S.3
  • 8
    • 59649127716 scopus 로고    scopus 로고
    • Estimated radiation dose associated with cardiac CT angiography
    • J. Hausleiter, T. Meyer, and F. Hermann Estimated radiation dose associated with cardiac CT angiography JAMA 301 2009 500 507
    • (2009) JAMA , vol.301 , pp. 500-507
    • Hausleiter, J.1    Meyer, T.2    Hermann, F.3
  • 9
    • 49049116757 scopus 로고    scopus 로고
    • Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: Comparison of image quality and patient radiation dose
    • W.P. Shuman, K.R. Branch, and J.M. May Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose Radiology 248 2008 431 437
    • (2008) Radiology , vol.248 , pp. 431-437
    • Shuman, W.P.1    Branch, K.R.2    May, J.M.3
  • 10
    • 34447338023 scopus 로고    scopus 로고
    • Image quality and reconstruction intervals of dual-source CT coronary angiography: Recommendations for ECG pulsing windowing
    • S. Leschka, H. Scheffel, and L. Desbiolles Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG pulsing windowing Invest Radiol 42 2007 543 549
    • (2007) Invest Radiol , vol.42 , pp. 543-549
    • Leschka, S.1    Scheffel, H.2    Desbiolles, L.3
  • 11
    • 34547121691 scopus 로고    scopus 로고
    • Strategies for reduction of radiation dose in cardiac multislice CT
    • J.F. Paul, and H.T. Abada Strategies for reduction of radiation dose in cardiac multislice CT Eur Radiol 17 2007 2028 2037
    • (2007) Eur Radiol , vol.17 , pp. 2028-2037
    • Paul, J.F.1    Abada, H.T.2
  • 12
    • 49049120370 scopus 로고    scopus 로고
    • Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: Assessment of image quality, stenosis, and radiation dose
    • N. Hirai, J. Horiguchi, and C. Fujioka Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose Radiology 248 2008 424 430
    • (2008) Radiology , vol.248 , pp. 424-430
    • Hirai, N.1    Horiguchi, J.2    Fujioka, C.3
  • 13
    • 77956832667 scopus 로고    scopus 로고
    • Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: The ERASIR study
    • J. Leipsic, T.M. Labounty, and B. Heilbron Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study AJR Am J Roentgenol 195 2010 655 660
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 655-660
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3
  • 14
    • 63449097524 scopus 로고    scopus 로고
    • High-pitch spiral acquisition: A new scan mode for coronary CT angiography
    • S. Achenbach, M. Marwan, and T. Schepis High-pitch spiral acquisition: a new scan mode for coronary CT angiography J Cardiovasc Comput Tomogr 3 2009 117 121
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 117-121
    • Achenbach, S.1    Marwan, M.2    Schepis, T.3
  • 15
    • 70350210490 scopus 로고    scopus 로고
    • Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: Technique and initial experience
    • M. Lell, M. Marwan, and T. Schepis Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience Eur Radiol 19 2009 2576 2583
    • (2009) Eur Radiol , vol.19 , pp. 2576-2583
    • Lell, M.1    Marwan, M.2    Schepis, T.3
  • 16
    • 84861478737 scopus 로고    scopus 로고
    • Image quality and dose performance of 80 kV low dose scan protocol in high-pitch spiral coronary CT angiography: Feasibility study
    • D. Wang, X.H. Hu, and S.Z. Zhang Image quality and dose performance of 80 kV low dose scan protocol in high-pitch spiral coronary CT angiography: feasibility study Int J Cardiovasc Imaging 28 2012 415 423
    • (2012) Int J Cardiovasc Imaging , vol.28 , pp. 415-423
    • Wang, D.1    Hu, X.H.2    Zhang, S.Z.3
  • 17
    • 0016490238 scopus 로고
    • A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association
    • W.G. Austen, J.E. Edwards, and R.L. Frye A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association Circulation 51 1975 5 40
    • (1975) Circulation , vol.51 , pp. 5-40
    • Austen, W.G.1    Edwards, J.E.2    Frye, R.L.3
  • 19
    • 78249233337 scopus 로고    scopus 로고
    • Cardiac CT: Are we underestimating the dose? A radiation dose study utilizing the 2007 ICRP tissue weighting factors and cardiac specific scan volume
    • O. Gosling, R. Loader, and P. Venables Cardiac CT: are we underestimating the dose? A radiation dose study utilizing the 2007 ICRP tissue weighting factors and cardiac specific scan volume Clin Radiol 65 2010 1013 1017
    • (2010) Clin Radiol , vol.65 , pp. 1013-1017
    • Gosling, O.1    Loader, R.2    Venables, P.3
  • 20
    • 77953710955 scopus 로고    scopus 로고
    • A comparison of radiation doses between state-of-the-art multislice CT coronary angiography with iterative reconstruction, multislice CT coronary angiography with standard filtered back-projection and invasive diagnostic coronary angiography
    • O. Gosling, R. Loader, and P. Venables A comparison of radiation doses between state-of-the-art multislice CT coronary angiography with iterative reconstruction, multislice CT coronary angiography with standard filtered back-projection and invasive diagnostic coronary angiography Heart 96 2010 922 926
    • (2010) Heart , vol.96 , pp. 922-926
    • Gosling, O.1    Loader, R.2    Venables, P.3
  • 21
    • 77950143210 scopus 로고    scopus 로고
    • Radiation dose from single-heart beat coronary CT angiography performed with a 320-detector row volume scanner
    • A.J. Einstein, C.D. Elliston, and A.E. Arai Radiation dose from single-heart beat coronary CT angiography performed with a 320-detector row volume scanner Radiology 254 2010 698 706
    • (2010) Radiology , vol.254 , pp. 698-706
    • Einstein, A.J.1    Elliston, C.D.2    Arai, A.E.3
  • 22
    • 0032580320 scopus 로고    scopus 로고
    • Two-sided confidence intervals for the single proportion: Comparison of seven methods
    • R.G. Newcombe Two-sided confidence intervals for the single proportion: comparison of seven methods Stat Med 17 1998 857 872
    • (1998) Stat Med , vol.17 , pp. 857-872
    • Newcombe, R.G.1
  • 23
    • 62649158904 scopus 로고    scopus 로고
    • Prospectively gated axial CT coronary angiography: Preliminary experiences with a novel low-dose technique
    • O. Klass, M. Jeltsch, and S. Feuerlein Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique Eur Radiol 19 2009 829 836
    • (2009) Eur Radiol , vol.19 , pp. 829-836
    • Klass, O.1    Jeltsch, M.2    Feuerlein, S.3
  • 24
    • 50249178242 scopus 로고    scopus 로고
    • Low-dose CT coronary angiography in the step-and-shoot mode: Diagnostic performance
    • H. Scheffel, H. Alkadhi, and S. Leschka Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance Heart 94 2008 1132 1137
    • (2008) Heart , vol.94 , pp. 1132-1137
    • Scheffel, H.1    Alkadhi, H.2    Leschka, S.3
  • 25
    • 77953702967 scopus 로고    scopus 로고
    • Low-dose, 128-slice, dual-source CT coronary angiography: Accuracy and radiation dose of the high-pitch and the step-and-shoot mode
    • H. Alkadhi, P. Stolzmann, and L. Desbiolles Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode Heart 96 2010 933 938
    • (2010) Heart , vol.96 , pp. 933-938
    • Alkadhi, H.1    Stolzmann, P.2    Desbiolles, L.3
  • 26
    • 70349774691 scopus 로고    scopus 로고
    • Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: Comparison of results with cardiac catheterization in a head-to-head pilot investigation
    • M. Dewey, E. Zimmermann, and F. Deissenrieder Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation Circulation 120 2009 867 875
    • (2009) Circulation , vol.120 , pp. 867-875
    • Dewey, M.1    Zimmermann, E.2    Deissenrieder, F.3
  • 27
    • 71449119488 scopus 로고    scopus 로고
    • Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: First experience
    • S. Leschka, P. Stolzmann, and L. Desbiolles Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience Eur Radiol 19 2009 2896 2903
    • (2009) Eur Radiol , vol.19 , pp. 2896-2903
    • Leschka, S.1    Stolzmann, P.2    Desbiolles, L.3
  • 28
    • 78649755609 scopus 로고    scopus 로고
    • Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT
    • W.H. Sommer, E. Albrecht, and F. Bamberg Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT AJR Am J Roentgenol 195 2010 1306 1312
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 1306-1312
    • Sommer, W.H.1    Albrecht, E.2    Bamberg, F.3
  • 29
    • 77950604781 scopus 로고    scopus 로고
    • High-pitch dual-source CT angiography of the thoracic and abdominal aorta: Is simultaneous coronary artery assessment possible?
    • R. Goetti, S. Baumüller, and G. Feuchtner High-pitch dual-source CT angiography of the thoracic and abdominal aorta: is simultaneous coronary artery assessment possible? AJR Am J Roentgenol 194 2010 938 944
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 938-944
    • Goetti, R.1    Baumüller, S.2    Feuchtner, G.3
  • 30
    • 80054984676 scopus 로고    scopus 로고
    • Iterative reconstruction in image space (IRIS) in cardiac computed tomography: Initial experience
    • M.S. Bittencourt, B. Schmidt, and M. Seltmann Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience Int J Cardiovasc Imaging 27 2011 1081 1087
    • (2011) Int J Cardiovasc Imaging , vol.27 , pp. 1081-1087
    • Bittencourt, M.S.1    Schmidt, B.2    Seltmann, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.