-
1
-
-
0028451094
-
Tightening characteristics for screwed joints in osseointegrated dental implants
-
Burguete RL, Johns RB, King T, Patterson EA. Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosthet Dent 1994; 71: 592-599.
-
(1994)
J Prosthet Dent
, vol.71
, pp. 592-599
-
-
Burguete, R.L.1
Johns, R.B.2
King, T.3
Patterson, E.A.4
-
2
-
-
0029302999
-
Nonlinear contact analysis of preload in dental implant screws
-
Sakaguchi RL, Borgersen SE. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants 1995; 10: 295-302.
-
(1995)
Int J Oral Maxillofac Implants
, vol.10
, pp. 295-302
-
-
Sakaguchi, R.L.1
Borgersen, S.E.2
-
4
-
-
0033192526
-
Effect of washers on reverse torque displacement of dental implant gold retaining screws
-
Korioth TW, Cardoso AC, Versluis A. Effect of washers on reverse torque displacement of dental implant gold retaining screws. J Prosthet Dent 1999; 82: 312-316.
-
(1999)
J Prosthet Dent
, vol.82
, pp. 312-316
-
-
Korioth, T.W.1
Cardoso, A.C.2
Versluis, A.3
-
5
-
-
0035404046
-
Operatorinduced compressive axial forces during implant gold screw fastening
-
Pesun IJ, Brosky ME, Korioth TW, Hodges J, Devoe BJ. Operatorinduced compressive axial forces during implant gold screw fastening. J Prosthet Dent 2001; 86: 15-19.
-
(2001)
J Prosthet Dent
, vol.86
, pp. 15-19
-
-
Pesun, I.J.1
Brosky, M.E.2
Korioth, T.W.3
Hodges, J.4
Devoe, B.J.5
-
6
-
-
0028393761
-
Clinical evaluation of single-tooth restorations supported by osseointegrated implants: A retrospective study
-
Ekfeldt A, Carlsson GE, Borjesson G. Clinical evaluation of single-tooth restorations supported by osseointegrated implants: A retrospective study. Int J Oral Maxillofac Implants 1994; 9: 179-183.
-
(1994)
Int J Oral Maxillofac Implants
, vol.9
, pp. 179-183
-
-
Ekfeldt, A.1
Carlsson, G.E.2
Borjesson, G.3
-
8
-
-
0029335615
-
Replacement of maxillary and mandibular molars with single endosseous implant restorations: A retrospective study
-
Becker W, Becker BE. Replacement of maxillary and mandibular molars with single endosseous implant restorations: A retrospective study. J Prosthet Dent 1995; 74: 51-55.
-
(1995)
J Prosthet Dent
, vol.74
, pp. 51-55
-
-
Becker, W.1
Becker, B.E.2
-
9
-
-
0039829366
-
The role of screws in implant systems
-
Binon PP, Sutter F, Beaty K, Brunski JB, Gulbransen H, Weiner R. The role of screws in implant systems. Int J Oral Maxillofac Implants 1994; 9(suppl): 48-63.
-
(1994)
Int J Oral Maxillofac Implants
, vol.9
, pp. 48-63
-
-
Binon, P.P.1
Sutter, F.2
Beaty, K.3
Brunski, J.B.4
Gulbransen, H.5
Weiner, R.6
-
10
-
-
0026921977
-
Loads and designs of screw joints for single crowns supported by osseointegrated implants
-
Jörneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992; 7: 353-359.
-
(1992)
Int J Oral Maxillofac Implants
, vol.7
, pp. 353-359
-
-
Jörneus, L.1
Jemt, T.2
Carlsson, L.3
-
12
-
-
84995764235
-
Suggested tightening torques for structural bolts
-
Griffith HT. Suggested tightening torques for structural bolts. Fastener Technology 1987; 10: 78-85.
-
(1987)
Fastener Technology
, vol.10
, pp. 78-85
-
-
Griffith, H.T.1
-
13
-
-
0345580601
-
Biomechanical principles preventing prosthetic overload induced by bending
-
Rangert B, Sullivan R. Biomechanical principles preventing prosthetic overload induced by bending. Nobelpharma News 1993; 7: 4-5.
-
(1993)
Nobelpharma News
, vol.7
, pp. 4-5
-
-
Rangert, B.1
Sullivan, R.2
-
15
-
-
0035351110
-
Implant-abutment screw joint preload of 7 hex-top abutment systems
-
Tan KB, Nicholls JI. Implant-abutment screw joint preload of 7 hex-top abutment systems. Int J Oral Maxillofac Implants 2001; 16: 367-377.
-
(2001)
Int J Oral Maxillofac Implants
, vol.16
, pp. 367-377
-
-
Tan, K.B.1
Nicholls, J.I.2
-
17
-
-
0033628712
-
Implants and components: Entering the new millennium
-
Binon PP. Implants and components: Entering the new millennium. Int J Oral Maxillofac Implants 2000; 15: 76-94.
-
(2000)
Int J Oral Maxillofac Implants
, vol.15
, pp. 76-94
-
-
Binon, P.P.1
-
18
-
-
0039384910
-
Increasing implant-abutment preload by thin gold coating abutment screws [abstract]
-
Porter SS, Robb T. Increasing implant-abutment preload by thin gold coating abutment screws [abstract]. J Dent Res 1998; 77: 837.
-
(1998)
J Dent Res
, vol.77
, pp. 837
-
-
Porter, S.S.1
Robb, T.2
-
19
-
-
7244237988
-
Critical bending moment of implantabutment screw joint interfaces: Effect of torque levels and implant diameter
-
Tan BF, Tan KB, Nicholls JI. Critical bending moment of implantabutment screw joint interfaces: Effect of torque levels and implant diameter. Int J Oral Maxillofac Implants 2004; 19: 648-658.
-
(2004)
Int J Oral Maxillofac Implants
, vol.19
, pp. 648-658
-
-
Tan, B.F.1
Tan, K.B.2
Nicholls, J.I.3
-
20
-
-
0026167259
-
Mechanical aspects of a Brånemark implant connected to a natural tooth: An in vitro study
-
Rangert B, Gunne J, Sullivan DY. Mechanical aspects of a Brånemark implant connected to a natural tooth: An in vitro study. Int J Oral Maxillofac Implants 1991; 6: 177-186.
-
(1991)
Int J Oral Maxillofac Implants
, vol.6
, pp. 177-186
-
-
Rangert, B.1
Gunne, J.2
Sullivan, D.Y.3
-
21
-
-
33646240845
-
Preloads generated with repeated tightening in three types of screws used in dental implant assemblies
-
Byrne D, Jacobs S, O’Connell B, Houston F, Claffey N. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. J Prosthodont 2006; 15: 164-171.
-
(2006)
J Prosthodont
, vol.15
, pp. 164-171
-
-
Byrne, D.1
Jacobs, S.2
O’Connell, B.3
Houston, F.4
Claffey, N.5
|