메뉴 건너뛰기




Volumn 44, Issue 7, 2012, Pages 2202-2206

Effect of increased pressure during pulsatile pump perfusion of deceased donor kidneys in transplantation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; COLD ISCHEMIA; CONFERENCE PAPER; DIASTOLIC BLOOD PRESSURE; FLOW RATE; GRAFT PERFUSION; GRAFT SURVIVAL; HUMAN; KIDNEY DONOR; KIDNEY PERFUSION; KIDNEY TRANSPLANTATION; MAJOR CLINICAL STUDY; OUTCOME ASSESSMENT; PRIORITY JOURNAL; PULSATILE PUMP PERFUSION; RETROSPECTIVE STUDY; SENSITIZATION; SYSTOLIC BLOOD PRESSURE;

EID: 84866340457     PISSN: 00411345     EISSN: 18732623     Source Type: Journal    
DOI: 10.1016/j.transproceed.2012.07.109     Document Type: Conference Paper
Times cited : (13)

References (14)
  • 1
    • 58249089430 scopus 로고    scopus 로고
    • Machine perfusion or cold storage in deceased-donor kidney transplantation
    • C. Moers, J.M. Smits, M.H. Maathuis Machine perfusion or cold storage in deceased-donor kidney transplantation N Engl J Med 360 2009 7
    • (2009) N Engl J Med , vol.360 , pp. 7
    • Moers, C.1    Smits, J.M.2    Maathuis, M.H.3
  • 2
    • 78349293444 scopus 로고    scopus 로고
    • Machine perfusion versus cold storage for the preservation of kidneys donated after cardiac death: A multicenter, randomized, controlled trial
    • I. Jochmans, C. Moers, J.M. Smits Machine perfusion versus cold storage for the preservation of kidneys donated after cardiac death: a multicenter, randomized, controlled trial Ann Surg 252 2010 756
    • (2010) Ann Surg , vol.252 , pp. 756
    • Jochmans, I.1    Moers, C.2    Smits, J.M.3
  • 3
    • 80053327103 scopus 로고    scopus 로고
    • The prognostic value of renal resistance during hypothermic machine perfusion of deceased donor kidneys
    • I. Jochmans, C. Moers, J.M. Smits The prognostic value of renal resistance during hypothermic machine perfusion of deceased donor kidneys Am J Transplant 11 2011 2214
    • (2011) Am J Transplant , vol.11 , pp. 2214
    • Jochmans, I.1    Moers, C.2    Smits, J.M.3
  • 4
    • 82455162512 scopus 로고    scopus 로고
    • Renovascular resistance of machine-perfused DCD kidneys is associated with primary nonfunction
    • E.E. de Vries, E.R. Hoogland, B. Winkens Renovascular resistance of machine-perfused DCD kidneys is associated with primary nonfunction Am J Transplant 11 2011 2685
    • (2011) Am J Transplant , vol.11 , pp. 2685
    • De Vries, E.E.1    Hoogland, E.R.2    Winkens, B.3
  • 5
    • 0014427772 scopus 로고
    • Perfusion pressure in kidney preservation
    • B.S. Ashby, F.O. Belzer Perfusion pressure in kidney preservation Nature 220 1968 794
    • (1968) Nature , vol.220 , pp. 794
    • Ashby, B.S.1    Belzer, F.O.2
  • 6
    • 0014359126 scopus 로고
    • The aetiology of rising perfusion pressure in renal preservation
    • B.S. Ashby, F.O. Belzer, J. Huang The aetiology of rising perfusion pressure in renal preservation British J Surg 55 1968 863
    • (1968) British J Surg , vol.55 , pp. 863
    • Ashby, B.S.1    Belzer, F.O.2    Huang, J.3
  • 7
    • 0014333296 scopus 로고
    • Etiology of rising perfusion pressure in isolated organ perfusion
    • F.O. Belzer, B.S. Ashby, J.S. Huang Etiology of rising perfusion pressure in isolated organ perfusion Ann Surg 168 1968 382
    • (1968) Ann Surg , vol.168 , pp. 382
    • Belzer, F.O.1    Ashby, B.S.2    Huang, J.S.3
  • 8
    • 0029004601 scopus 로고
    • Pathophysiology and related studies of the no reflow phenomenon in skeletal muscle
    • D.M. Allen, L.E. Chen, A.V. Seaber Pathophysiology and related studies of the no reflow phenomenon in skeletal muscle Clin Orthop Relat Res 314 1995 122
    • (1995) Clin Orthop Relat Res , vol.314 , pp. 122
    • Allen, D.M.1    Chen, L.E.2    Seaber, A.V.3
  • 9
    • 78951471285 scopus 로고    scopus 로고
    • Analysis of machine perfusion benefits in kidney grafts: A preclinical study
    • N. Vaziri, R. Thuillier, F.D. Favreau Analysis of machine perfusion benefits in kidney grafts: a preclinical study J Trans Med 9 2011 15
    • (2011) J Trans Med , vol.9 , pp. 15
    • Vaziri, N.1    Thuillier, R.2    Favreau, F.D.3
  • 10
    • 79955569761 scopus 로고    scopus 로고
    • Machine perfusion versus cold storage for preservation of kidneys from expanded criteria donors after brain death
    • J. Treckmann, C. Moers, J.M. Smits Machine perfusion versus cold storage for preservation of kidneys from expanded criteria donors after brain death Transpl Int 24 2011 548
    • (2011) Transpl Int , vol.24 , pp. 548
    • Treckmann, J.1    Moers, C.2    Smits, J.M.3
  • 11
    • 40449114234 scopus 로고    scopus 로고
    • Determinants of discard of expanded criteria donor kidneys: Impact of biopsy and machine perfusion
    • R.S. Sung, L.L. Christensen, A.B. Leichtman Determinants of discard of expanded criteria donor kidneys: impact of biopsy and machine perfusion Am J Transplant 8 2008 783
    • (2008) Am J Transplant , vol.8 , pp. 783
    • Sung, R.S.1    Christensen, L.L.2    Leichtman, A.B.3
  • 12
    • 2442602127 scopus 로고    scopus 로고
    • Ex-vivo study of flow dynamics and endothelial cell structure during extended hypothermic machine perfusion preservation of livers
    • S. Jain, H. Xu, H. Duncan Ex-vivo study of flow dynamics and endothelial cell structure during extended hypothermic machine perfusion preservation of livers Cryobiology 48 2004 322
    • (2004) Cryobiology , vol.48 , pp. 322
    • Jain, S.1    Xu, H.2    Duncan, H.3
  • 13
    • 36549079087 scopus 로고    scopus 로고
    • Improved kidney graft function after preservation using a novel hypothermic machine perfusion device
    • discussion 9
    • M.H. Maathuis, S. Manekeller, A. van der Plaats Improved kidney graft function after preservation using a novel hypothermic machine perfusion device Ann Surg 246 2007 982 discussion 9
    • (2007) Ann Surg , vol.246 , pp. 982
    • Maathuis, M.H.1    Manekeller, S.2    Van Der Plaats, A.3
  • 14
    • 79951550119 scopus 로고    scopus 로고
    • Hypothermic machine perfusion of kidney grafts: Which pressure is preferred?
    • B.M. Doorschodt, M.C. Schreinemachers, M. Behbahani Hypothermic machine perfusion of kidney grafts: which pressure is preferred? Ann Biomed Eng 39 2011 1051
    • (2011) Ann Biomed Eng , vol.39 , pp. 1051
    • Doorschodt, B.M.1    Schreinemachers, M.C.2    Behbahani, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.