메뉴 건너뛰기




Volumn 25, Issue 10, 2012, Pages 1144-1151

High-resolution ZTE imaging of human teeth

Author keywords

Algebraic image reconstruction; Caries lesions; Dental filling; Dentine and enamel; Early demineralisation; High bandwidth; Transmit receive switching; Zero echo time

Indexed keywords

CARIES LESIONS; DEMINERALISATION; ECHO TIME; ENAMEL LAYERS; FIELD STRENGTHS; HIGH BANDWIDTH; HIGH RESOLUTION; HIGH-RESOLUTION IMAGING; HUMAN TEETHS; MICROCOMPUTED TOMOGRAPHY; RF EXCITATION;

EID: 84866300911     PISSN: 09523480     EISSN: 10991492     Source Type: Journal    
DOI: 10.1002/nbm.2783     Document Type: Article
Times cited : (114)

References (38)
  • 1
  • 2
    • 33646447508 scopus 로고    scopus 로고
    • Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling
    • Rahmer J, Börnert P, Groen J, Bos C. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn. Reson. Med. 2006; 55: 1075-1082.
    • (2006) Magn. Reson. Med. , vol.55 , pp. 1075-1082
    • Rahmer, J.1    Börnert, P.2    Groen, J.3    Bos, C.4
  • 3
    • 0037236412 scopus 로고    scopus 로고
    • Magnetic resonance imaging of short T2 components in tissue
    • Gatehouse PD, Bydder GM. Magnetic resonance imaging of short T2 components in tissue. Clin. Radiol. 2003; 58; 1-19.
    • (2003) Clin. Radiol. , vol.58 , pp. 1-19
    • Gatehouse, P.D.1    Bydder, G.M.2
  • 5
    • 0027991443 scopus 로고
    • Fast imaging in liquids and solids with the back-projection low angle shot (BLAST) technique
    • Hafner S. Fast imaging in liquids and solids with the back-projection low angle shot (BLAST) technique. Magn. Reson. Imag. 1994; 12: 1047-1051.
    • (1994) Magn. Reson. Imag. , vol.12 , pp. 1047-1051
    • Hafner, S.1
  • 6
    • 0029099442 scopus 로고
    • Ultra-fast imaging using low flip angles and FIDs
    • Madio DP, Lowe IJ. Ultra-fast imaging using low flip angles and FIDs. Magn. Reson. Med. 1995; 34: 525-529.
    • (1995) Magn. Reson. Med. , vol.34 , pp. 525-529
    • Madio, D.P.1    Lowe, I.J.2
  • 9
    • 84856212651 scopus 로고    scopus 로고
    • Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA)
    • 2011. DOI: 10.1002/mrm.23017. (Epub ahead of print).
    • Grodzki DM, Jakob PM, Heismann B. Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA). Magn. Reson. Med. 2011. DOI: 10.1002/mrm.23017. (Epub ahead of print).
    • Magn. Reson. Med.
    • Grodzki, D.M.1    Jakob, P.M.2    Heismann, B.3
  • 11
    • 0032991106 scopus 로고    scopus 로고
    • Quantitative solid-state NMR imaging of synthetic calcium phosphate implants
    • Ramanathan C, Ackerman JL. Quantitative solid-state NMR imaging of synthetic calcium phosphate implants. Magn. Reson. Med. 1999; 41: 1214-1220.
    • (1999) Magn. Reson. Med. , vol.41 , pp. 1214-1220
    • Ramanathan, C.1    Ackerman, J.L.2
  • 12
  • 13
    • 0037925188 scopus 로고    scopus 로고
    • Density of organic matrix of native mineralized bone measured by water- and fat-suppressed proton projection MRI
    • Wu Y, Ackerman JL, Chesler DA, Graham L, Wang J, Glimcher MJ. Density of organic matrix of native mineralized bone measured by water- and fat-suppressed proton projection MRI. Magn. Reson. Med. 2003; 50: 59-68.
    • (2003) Magn. Reson. Med. , vol.50 , pp. 59-68
    • Wu, Y.1    Ackerman, J.L.2    Chesler, D.A.3    Graham, L.4    Wang, J.5    Glimcher, M.J.6
  • 14
    • 34250345248 scopus 로고    scopus 로고
    • Short data acquisition times improve projection images of lung tissue
    • Kuethe DO, Adolphi NL, Fukushima E. Short data acquisition times improve projection images of lung tissue. Magn. Reson. Med. 2007; 57: 1058-1064.
    • (2007) Magn. Reson. Med. , vol.57 , pp. 1058-1064
    • Kuethe, D.O.1    Adolphi, N.L.2    Fukushima, E.3
  • 15
    • 79960600053 scopus 로고    scopus 로고
    • MRI with zero echo time: hard versus sweep pulse excitation
    • Weiger M, Pruessmann KP, Hennel F. MRI with zero echo time: hard versus sweep pulse excitation. Magn. Reson. Med. 2011; 66: 379-389.
    • (2011) Magn. Reson. Med. , vol.66 , pp. 379-389
    • Weiger, M.1    Pruessmann, K.P.2    Hennel, F.3
  • 18
    • 0021689594 scopus 로고
    • Composition and relaxation of the proton magnetization of human enamel and its contribution to the tooth NMR image
    • Funduk N, Kydon DW, Schreiner LJ, Peemoeller H, Miljković L, Pintar MM. Composition and relaxation of the proton magnetization of human enamel and its contribution to the tooth NMR image. Magn. Reson. Med. 1984; 1: 66-75.
    • (1984) Magn. Reson. Med. , vol.1 , pp. 66-75
    • Funduk, N.1    Kydon, D.W.2    Schreiner, L.J.3    Peemoeller, H.4    Miljković, L.5    Pintar, M.M.6
  • 19
    • 22144475761 scopus 로고    scopus 로고
    • MR imaging with ultrashort TE (UTE) pulse sequence: Basic Principles
    • Holmes JE, Bydder GM. MR imaging with ultrashort TE (UTE) pulse sequence: Basic Principles. Radiography 2005; 11: 163-174.
    • (2005) Radiography , vol.11 , pp. 163-174
    • Holmes, J.E.1    Bydder, G.M.2
  • 20
    • 79960582912 scopus 로고    scopus 로고
    • Feasibility of ultra-short echo time (UTE) magnetic resonance imaging for identification of carious lesions
    • Bracher AK, Hofmann CP, Boujraf S, Ulrici J, Hell E, Spahr A, et al. Feasibility of ultra-short echo time (UTE) magnetic resonance imaging for identification of carious lesions. Magn. Reson. Med. 2001; 66: 538-545.
    • (2001) Magn. Reson. Med. , vol.66 , pp. 538-545
    • Bracher, A.K.1    Hofmann, C.P.2    Boujraf, S.3    Ulrici, J.4    Hell, E.5    Spahr, A.6
  • 23
    • 0036675958 scopus 로고    scopus 로고
    • Solid-state nuclear magnetic resonance microscopy demonstrating human dental anatomy
    • Appel TR, Baumann MA. Solid-state nuclear magnetic resonance microscopy demonstrating human dental anatomy. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002; 94: 256-61.
    • (2002) Oral Surg Oral Med Oral Pathol Oral Radiol Endod. , vol.94 , pp. 256-261
    • Appel, T.R.1    Baumann, M.A.2
  • 27
    • 84866270055 scopus 로고    scopus 로고
    • Direct MRI of human teeth by SWIFT. Proceedings of the 15th Annual Meeting ISMRM, Berlin, Germany
    • Idiyatullin D, Corum C, McIntosh A, Moeller S, Garwood M. Direct MRI of human teeth by SWIFT. Proceedings of the 15th Annual Meeting ISMRM, Berlin, Germany, 2007; 383.
    • (2007) , pp. 383
    • Idiyatullin, D.1    Corum, C.2    McIntosh, A.3    Moeller, S.4    Garwood, M.5
  • 29
    • 84866293532 scopus 로고    scopus 로고
    • Microstructural assessment of dental tissues by quantitative MRI using ultra-short echo times (UTE): initial in-vitro evaluation. Proceedings of the 16th Annual Meeting ISMRM, Honolulu, USA
    • Boujraf S, Hofmann C, Ulrici J, Hell E, Haller B, Rasche V. Microstructural assessment of dental tissues by quantitative MRI using ultra-short echo times (UTE): initial in-vitro evaluation. Proceedings of the 16th Annual Meeting ISMRM, Honolulu, USA, 2009; 4520.
    • (2009) , pp. 4520
    • Boujraf, S.1    Hofmann, C.2    Ulrici, J.3    Hell, E.4    Haller, B.5    Rasche, V.6
  • 30
    • 84866300743 scopus 로고    scopus 로고
    • Microstructural assessment of dental tissues by quantitative MRI using ultra-short echo times (UTE): initial in-vivo evaluation. Proceedings of the 16th Annual Meeting ISMRM, Honolulu, USA
    • Boujraf S, Hofmann C, Ulrici J, Hell E, Haller B, Rasche V. Microstructural assessment of dental tissues by quantitative MRI using ultra-short echo times (UTE): initial in-vivo evaluation. Proceedings of the 16th Annual Meeting ISMRM, Honolulu, USA, 2009; 4518.
    • (2009) , pp. 4518
    • Boujraf, S.1    Hofmann, C.2    Ulrici, J.3    Hell, E.4    Haller, B.5    Rasche, V.6
  • 36
    • 0032059889 scopus 로고    scopus 로고
    • Simple correction method for k-space trajectory deviations in MRI
    • Duyn JH, Yang Y, Frank JA, van der Veen JW. Simple correction method for k-space trajectory deviations in MRI. J. Magn. Reson. 1998; 132: 150-153.
    • (1998) J. Magn. Reson. , vol.132 , pp. 150-153
    • Duyn, J.H.1    Yang, Y.2    Frank, J.A.3    van der Veen, J.W.4
  • 37
    • 33744530417 scopus 로고    scopus 로고
    • Encoding and reconstruction in parallel MRI
    • Pruessmann KP. Encoding and reconstruction in parallel MRI. NMR Biomed. 2006; 19: 288-299.
    • (2006) NMR Biomed. , vol.19 , pp. 288-299
    • Pruessmann, K.P.1
  • 38
    • 84866276656 scopus 로고    scopus 로고
    • Anomalous noise behaviour in ZTE imaging. Proceedings of the 18th Annual Meeting ISMRM, Montreal, Canada
    • Weiger M, Pruessmann KP. Anomalous noise behaviour in ZTE imaging. Proceedings of the 18th Annual Meeting ISMRM, Montreal, Canada, 2011; 747.
    • (2011) , pp. 747
    • Weiger, M.1    Pruessmann, K.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.