-
1
-
-
0037236412
-
Magnetic resonance imaging of short T2 components in tissue
-
Gatehouse PD, Bydder M,. Magnetic resonance imaging of short T2 components in tissue. Clin Radiol 2003; 58; 1-19.
-
(2003)
Clin Radiol
, vol.58
, pp. 1-19
-
-
Gatehouse, P.D.1
Bydder, M.2
-
2
-
-
36148981447
-
Proton magnetic resonance imaging for assessment of lung function and respiratory dynamics
-
Eichinger M, Tetzlaff R, Puderbach M, Woodhouse N, Kauczor HU,. Proton magnetic resonance imaging for assessment of lung function and respiratory dynamics. Eur J Radiol 2007; 64; 329-334.
-
(2007)
Eur J Radiol
, vol.64
, pp. 329-334
-
-
Eichinger, M.1
Tetzlaff, R.2
Puderbach, M.3
Woodhouse, N.4
Kauczor, H.U.5
-
3
-
-
0026451769
-
Boron-11 imaging with a three-dimensional reconstruction method
-
Glover GH, Pauly JM, Bradshaw KM,. Boron-11 imaging with a three-dimensional reconstruction method. J Magn Reson Imaging 1992; 2: 47-52.
-
(1992)
J Magn Reson Imaging
, vol.2
, pp. 47-52
-
-
Glover, G.H.1
Pauly, J.M.2
Bradshaw, K.M.3
-
4
-
-
0000178929
-
Sensitivity and resolution in NMR imaging
-
Callaghan PT, Eccles CD,. Sensitivity and resolution in NMR imaging. J Magn Reson 1987; 71: 426-445.
-
(1987)
J Magn Reson
, vol.71
, pp. 426-445
-
-
Callaghan, P.T.1
Eccles, C.D.2
-
5
-
-
33646447508
-
Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling
-
Rahmer J, Börnert P, Groen J, Bos C,. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn Reson Med 2006; 55: 1075-1082.
-
(2006)
Magn Reson Med
, vol.55
, pp. 1075-1082
-
-
Rahmer, J.1
Börnert, P.2
Groen, J.3
Bos, C.4
-
6
-
-
0027991443
-
Fast imaging in liquids and solids with the back-projection low angle shot (BLAST) technique
-
Hafner S,. Fast imaging in liquids and solids with the back-projection low angle shot (BLAST) technique. Magn Reson Imaging 1994; 12: 1047-1051.
-
(1994)
Magn Reson Imaging
, vol.12
, pp. 1047-1051
-
-
Hafner, S.1
-
7
-
-
0029099442
-
Ultra-fast imaging using low flip angles and FIDs
-
Madio DP, Lowe IJ,. Ultra-fast imaging using low flip angles and FIDs. Magn Reson Med 1995; 34: 525-529.
-
(1995)
Magn Reson Med
, vol.34
, pp. 525-529
-
-
Madio, D.P.1
Lowe, I.J.2
-
8
-
-
0031984714
-
Imaging lungs using inert fluorinated gases
-
Kuethe DO, Caprihan A, Fukushima E, Waggoner RA,. Imaging lungs using inert fluorinated gases. Magn Reson Med 1998; 39: 85-88.
-
(1998)
Magn Reson Med
, vol.39
, pp. 85-88
-
-
Kuethe, D.O.1
Caprihan, A.2
Fukushima, E.3
Waggoner, R.A.4
-
9
-
-
0031745382
-
Evaluation of bone mineral density using three-dimensional solid state phosphorus-31 NMR projection imaging
-
Wu Y, Ackerman JL, Chesler DA, Li J, Neer RM, Wang J, Glimcher MJ,. Evaluation of bone mineral density using three-dimensional solid state phosphorus-31 NMR projection imaging. Calcif Tissue Int 1998; 62: 512-518.
-
(1998)
Calcif Tissue Int
, vol.62
, pp. 512-518
-
-
Wu, Y.1
Ackerman, J.L.2
Chesler, D.A.3
Li, J.4
Neer, R.M.5
Wang, J.6
Glimcher, M.J.7
-
10
-
-
0001076476
-
Discrete Fourier transformation of NMR signals. The relationship between sampling delay time and spectral baseline
-
Zhu G, Torchia DA, Bax A,. Discrete Fourier transformation of NMR signals. The relationship between sampling delay time and spectral baseline. J Magn Reson A 1993; 105: 219-222.
-
(1993)
J Magn Reson A
, vol.105
, pp. 219-222
-
-
Zhu, G.1
Torchia, D.A.2
Bax, A.3
-
11
-
-
0033155738
-
Transforming NMR data despite missing points
-
Kuethe DO, Transforming NMR data despite missing points. J Magn Reson 1999; 139: 18-25.
-
(1999)
J Magn Reson
, vol.139
, pp. 18-25
-
-
Kuethe, D.O.1
-
12
-
-
33646777487
-
Single-point ramped imaging with T1 enhancement (SPRITE)
-
Balcom BJ, MacGregor RP, Beyea SD, Green DP, Armstrong RL, Bremner TW,. Single-point ramped imaging with T1 enhancement (SPRITE). J Magn Reson A 1996; 123: 131-134.
-
(1996)
J Magn Reson A
, vol.123
, pp. 131-134
-
-
Balcom, B.J.1
MacGregor, R.P.2
Beyea, S.D.3
Green, D.P.4
Armstrong, R.L.5
Bremner, T.W.6
-
13
-
-
0022598272
-
Use of frequency-modulated radiofrequency pulses in MR imaging experiments
-
Kunz DW,. Use of frequency-modulated radiofrequency pulses in MR imaging experiments. Magn Reson Med 1986; 3: 377-384.
-
(1986)
Magn Reson Med
, vol.3
, pp. 377-384
-
-
Kunz, D.W.1
-
14
-
-
0028850689
-
Spatial encoding and reconstruction in MRI with quadratic phase profiles
-
Pipe JG,. Spatial encoding and reconstruction in MRI with quadratic phase profiles. Magn Reson Med 1995; 33: 24-33.
-
(1995)
Magn Reson Med
, vol.33
, pp. 24-33
-
-
Pipe, J.G.1
-
15
-
-
47549104057
-
Gapped pulses for frequency-swept MRI
-
Idiyatullin D, Corum C, Moeller S, Garwood M,. Gapped pulses for frequency-swept MRI. J Magn Reson 2008; 193: 267-273.
-
(2008)
J Magn Reson
, vol.193
, pp. 267-273
-
-
Idiyatullin, D.1
Corum, C.2
Moeller, S.3
Garwood, M.4
-
16
-
-
33746312074
-
-
Idiyatullin D, Corum C, Park JY, Garwood M,. Fast and quiet MRI using a swept radiofrequency, J Magn Reson 2006; 181: 342-349.
-
(2006)
Fast and Quiet MRI Using A Swept Radiofrequency, J Magn Reson
, vol.181
, pp. 342-349
-
-
Idiyatullin, D.1
Corum, C.2
Park, J.Y.3
Garwood, M.4
-
17
-
-
78649603289
-
Progress in 3d Imaging at 4 T with SWIFT
-
Berlin
-
Corum CA, Idiyatullin D, Moeller S, Garwood M,. Progress in 3d Imaging at 4 T with SWIFT. In: Proceedings of International Society of Magnetic Resonance in Medicine, Berlin, 2007. p 1330.
-
(2007)
Proceedings of International Society of Magnetic Resonance in Medicine
, pp. 1330
-
-
Corum, C.A.1
Idiyatullin, D.2
Moeller, S.3
Garwood, M.4
-
18
-
-
0008757537
-
Correlation NMR spectroscopy
-
Dadok J, Sprecher RF,. Correlation NMR spectroscopy. J Magn Reson 1974; 13: 243-248.
-
(1974)
J Magn Reson
, vol.13
, pp. 243-248
-
-
Dadok, J.1
Sprecher, R.F.2
-
20
-
-
78649614736
-
Signal processing and image reconstruction for SWIFT
-
Berlin
-
Corum CA, Moeller S, Idiyatullin D, Garwood M,. Signal processing and image reconstruction for SWIFT. In: Proceedings of International Society of Magnetic Resonance in Medicine, Berlin, 2007. p 1669.
-
(2007)
Proceedings of International Society of Magnetic Resonance in Medicine
, pp. 1669
-
-
Corum, C.A.1
Moeller, S.2
Idiyatullin, D.3
Garwood, M.4
-
21
-
-
78649619036
-
Correction of RF pulse distortions in radial imaging using SWIFT
-
Toronto
-
Moeller S, Corum CA, Idiyatullin D, Chamberlain R, Garwood M,. Correction of RF pulse distortions in radial imaging using SWIFT, In: Proceedings of International Society of Magnetic Resonance in Medicine, Toronto, 2008. p. 229.
-
(2008)
Proceedings of International Society of Magnetic Resonance in Medicine
, pp. 229
-
-
Moeller, S.1
Corum, C.A.2
Idiyatullin, D.3
Chamberlain, R.4
Garwood, M.5
-
23
-
-
78649547038
-
Sampling strategies for MRI with simultaneous excitation and acquisition
-
Honolulu
-
Weiger M, Pruessmann KP, Tabbert M, Hennel F,. Sampling strategies for MRI with simultaneous excitation and acquisition. In: Proceedings of International Society of Magnetic Resonance in Medicine, Honolulu, 2009. p. 252.
-
(2009)
Proceedings of International Society of Magnetic Resonance in Medicine
, pp. 252
-
-
Weiger, M.1
Pruessmann, K.P.2
Tabbert, M.3
Hennel, F.4
-
24
-
-
0242565339
-
Application of real time digital filters in NMR spectroscopy
-
Moskau D,. Application of real time digital filters in NMR spectroscopy. Concepts Magn Reson 2002; 15: 164-176.
-
(2002)
Concepts Magn Reson
, vol.15
, pp. 164-176
-
-
Moskau, D.1
-
25
-
-
0000842145
-
Improved performance of frequency-swept pulses using offset-independent adiabaticity
-
Tannus A, Garwood M,. Improved performance of frequency-swept pulses using offset-independent adiabaticity. J Magn Reson A 1996; 120: 133-137.
-
(1996)
J Magn Reson A
, vol.120
, pp. 133-137
-
-
Tannus, A.1
Garwood, M.2
-
26
-
-
0000811634
-
Multiecho imaging sequences with low refocusing flip angles
-
Hennig J,. Multiecho imaging sequences with low refocusing flip angles. J Magn Reson 1988; 78: 397-407.
-
(1988)
J Magn Reson
, vol.78
, pp. 397-407
-
-
Hennig, J.1
-
27
-
-
0014905513
-
Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography
-
Gordon R, Bender R, Herman GT,. Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. J Theor Biol 1970; 29: 471-481.
-
(1970)
J Theor Biol
, vol.29
, pp. 471-481
-
-
Gordon, R.1
Bender, R.2
Herman, G.T.3
-
28
-
-
0024627075
-
Algebraic reconstruction in CT from limited views
-
Andersen AH,. Algebraic reconstruction in CT from limited views. IEEE Trans Med Imaging 1989; 8: 50-55.
-
(1989)
IEEE Trans Med Imaging
, vol.8
, pp. 50-55
-
-
Andersen, A.H.1
-
29
-
-
0032712873
-
SENSE: Sensitivity encoding for fast MRI
-
Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P,. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999; 42: 952-962.
-
(1999)
Magn Reson Med
, vol.42
, pp. 952-962
-
-
Pruessmann, K.P.1
Weiger, M.2
Scheidegger, M.B.3
Boesiger, P.4
-
30
-
-
33744530417
-
Encoding and reconstruction in parallel MRI
-
Pruessmann KP,. Encoding and reconstruction in parallel MRI. NMR Biomed 2006; 19: 288-299.
-
(2006)
NMR Biomed
, vol.19
, pp. 288-299
-
-
Pruessmann, K.P.1
-
31
-
-
1542346911
-
Parallel imaging reconstruction using automatic regularization
-
Lin FH, Kwong KK, Belliveau JW, Wald LL,. Parallel imaging reconstruction using automatic regularization. Magn Reson Med 2004; 51: 559-567.
-
(2004)
Magn Reson Med
, vol.51
, pp. 559-567
-
-
Lin, F.H.1
Kwong, K.K.2
Belliveau, J.W.3
Wald, L.L.4
-
32
-
-
32544450311
-
Minimum-norm reconstruction for sensitivity-encoded magnetic resonance spectroscopic imaging
-
Sanchez-Gonzalez J, Tsao J, Dydak U, Desco M, Boesiger P, Pruessmann KP,. Minimum-norm reconstruction for sensitivity-encoded magnetic resonance spectroscopic imaging. Magn Reson Med 2006; 55: 287-295.
-
(2006)
Magn Reson Med
, vol.55
, pp. 287-295
-
-
Sanchez-Gonzalez, J.1
Tsao, J.2
Dydak, U.3
Desco, M.4
Boesiger, P.5
Pruessmann, K.P.6
-
33
-
-
0026219520
-
Selection of a convolution function for Fourier inversion using gridding
-
Jackson JI, Meyer CH, Nishimura DG, Macovski A,. Selection of a convolution function for Fourier inversion using gridding. IEEE Trans Med Imaging 1991; 10: 473-478.
-
(1991)
IEEE Trans Med Imaging
, vol.10
, pp. 473-478
-
-
Jackson, J.I.1
Meyer, C.H.2
Nishimura, D.G.3
MacOvski, A.4
-
34
-
-
0346331285
-
Equi-ripple design of quadratic-phase RF pulses
-
Schulte RF, Tsao J, Boesiger P, Pruessmann KP,. Equi-ripple design of quadratic-phase RF pulses. J Magn Reson 2004; 166: 111-122.
-
(2004)
J Magn Reson
, vol.166
, pp. 111-122
-
-
Schulte, R.F.1
Tsao, J.2
Boesiger, P.3
Pruessmann, K.P.4
-
35
-
-
34249938021
-
Design of broadband RF pulses with polynomial-phase response
-
Schulte RF, Henning A, Tsao J, Boesiger P, Pruessmann KP,. Design of broadband RF pulses with polynomial-phase response. J Magn Reson 2007; 186: 167-175.
-
(2007)
J Magn Reson
, vol.186
, pp. 167-175
-
-
Schulte, R.F.1
Henning, A.2
Tsao, J.3
Boesiger, P.4
Pruessmann, K.P.5
-
36
-
-
33646438018
-
Ultrashort TE imaging with single-digit (8 μs) TE
-
Kyoto, Japan
-
Brittain JH, Shankaranarayanan A, Ramanan V, Shimakawa A, Cunningham CH, Hinks S, Francis R, Turner R, Johnson JW, Nayak KS, Tan S, Pauly JM, Bydder GM,. Ultrashort TE imaging with single-digit (8 μs) TE. In: Proceedings of the 12th Annual Meeting of ISMRM, Kyoto, Japan, 2004. p. 629.
-
(2004)
Proceedings of the 12th Annual Meeting of ISMRM
, pp. 629
-
-
Brittain, J.H.1
Shankaranarayanan, A.2
Ramanan, V.3
Shimakawa, A.4
Cunningham, C.H.5
Hinks, S.6
Francis, R.7
Turner, R.8
Johnson, J.W.9
Nayak, K.S.10
Tan, S.11
Pauly, J.M.12
Bydder, G.M.13
-
37
-
-
78649541492
-
Implementation of SWIFT on a Siemens clinical scanner
-
Honolulu
-
Valette J, Moeller S, Idiyatullin D, Corum C, Le Bihan D, Garwood M, Lethimonnier F,. Implementation of SWIFT on a Siemens clinical scanner. In: Proceedings of International Society of Magnetic Resonance in Medicine, Honolulu, 2009. p. 2672.
-
(2009)
Proceedings of International Society of Magnetic Resonance in Medicine
, pp. 2672
-
-
Valette, J.1
Moeller, S.2
Idiyatullin, D.3
Corum, C.4
Le Bihan, D.5
Garwood, M.6
Lethimonnier, F.7
-
38
-
-
0034794323
-
Advances in sensitivity encoding with arbitrary k-space trajectories
-
Pruessmann KP, Weiger M, Börnert P, Boesiger P,. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001; 46: 638-651.
-
(2001)
Magn Reson Med
, vol.46
, pp. 638-651
-
-
Pruessmann, K.P.1
Weiger, M.2
Börnert, P.3
Boesiger, P.4
-
39
-
-
0020644027
-
The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods
-
Twieg DB,. The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods. Med Phys 1983; 10: 610-621.
-
(1983)
Med Phys
, vol.10
, pp. 610-621
-
-
Twieg, D.B.1
-
41
-
-
0027494434
-
A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO)
-
Liu G, Sobering G, Duyn J, Moonen CT,. A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO). Magn Reson Med 1993; 30: 764-768.
-
(1993)
Magn Reson Med
, vol.30
, pp. 764-768
-
-
Liu, G.1
Sobering, G.2
Duyn, J.3
Moonen, C.T.4
|