-
1
-
-
0141920503
-
Burden of major musculoskeletal conditions
-
A.D. Woolf, and B. Pfleger Burden of major musculoskeletal conditions Bull World Health Organ 81 9 2003 646 656
-
(2003)
Bull World Health Organ
, vol.81
, Issue.9
, pp. 646-656
-
-
Woolf, A.D.1
Pfleger, B.2
-
3
-
-
77951909410
-
The evidence-based approach in bringing new orthopaedic devices to market
-
E.H. Schemitsch, M. Bhandari, S.D. Boden, R.B. Bourne, K.J. Bozic, and J.J. Jacobs The evidence-based approach in bringing new orthopaedic devices to market J Bone Joint Surg Am 92 4 2010 1030 1037
-
(2010)
J Bone Joint Surg Am
, vol.92
, Issue.4
, pp. 1030-1037
-
-
Schemitsch, E.H.1
Bhandari, M.2
Boden, S.D.3
Bourne, R.B.4
Bozic, K.J.5
Jacobs, J.J.6
-
4
-
-
0023809603
-
Early temporary porosis of bone induced by internal fixation implants. A reaction to necrosis, not to stress protection?
-
S.M. Perren, J. Cordey, B.A. Rahn, E. Gautier, and E. Schneider Early temporary porosis of bone induced by internal fixation implants. A reaction to necrosis, not to stress protection? Clin Orthop Relat Res 232 1988 139 151
-
(1988)
Clin Orthop Relat Res
, vol.232
, pp. 139-151
-
-
Perren, S.M.1
Cordey, J.2
Rahn, B.A.3
Gautier, E.4
Schneider, E.5
-
5
-
-
0031277777
-
In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur
-
A. Aamodt, J. Lund-Larsen, J. Eine, E. Andersen, P. Benum, and O.S. Husby In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur J Orthop Res 15 6 1997 927 931
-
(1997)
J Orthop Res
, vol.15
, Issue.6
, pp. 927-931
-
-
Aamodt, A.1
Lund-Larsen, J.2
Eine, J.3
Andersen, E.4
Benum, P.5
Husby, O.S.6
-
6
-
-
15944383441
-
Determination of muscle loading at the hip joint for use in pre-clinical testing
-
M.O. Heller, G. Bergmann, J.P. Kassi, L. Claes, N.P. Haas, and G.N. Duda Determination of muscle loading at the hip joint for use in pre-clinical testing J Biomech 38 5 2005 1155 1163
-
(2005)
J Biomech
, vol.38
, Issue.5
, pp. 1155-1163
-
-
Heller, M.O.1
Bergmann, G.2
Kassi, J.P.3
Claes, L.4
Haas, N.P.5
Duda, G.N.6
-
7
-
-
0014746120
-
Abduction forces in one-legged stance
-
R.D. Mcleish, and J. Charnley Abduction forces in one-legged stance J Biomech 3 2 1970 191
-
(1970)
J Biomech
, vol.3
, Issue.2
, pp. 191
-
-
McLeish, R.D.1
Charnley, J.2
-
8
-
-
0034984126
-
Hip contact forces and gait patterns from routine activities
-
G. Bergmann, G. Deuretzbacher, M. Heller, F. Graichen, A. Rohlmann, and J. Strauss Hip contact forces and gait patterns from routine activities J Biomech 34 7 2001 859 871
-
(2001)
J Biomech
, vol.34
, Issue.7
, pp. 859-871
-
-
Bergmann, G.1
Deuretzbacher, G.2
Heller, M.3
Graichen, F.4
Rohlmann, A.5
Strauss, J.6
-
9
-
-
0018090413
-
A biomechanical investigation of the human hip
-
R.D. Crowninshield, R.C. Johnston, J.G. Andrews, and R.A. Brand A biomechanical investigation of the human hip J Biomech 11 1-2 1978 75 85
-
(1978)
J Biomech
, vol.11
, Issue.12
, pp. 75-85
-
-
Crowninshield, R.D.1
Johnston, R.C.2
Andrews, J.G.3
Brand, R.A.4
-
10
-
-
57349085028
-
Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation
-
M. Windolf, V. Braunstein, C. Dutoit, and K. Schwieger Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation Clin Biomech (Bristol, Avon) 24 1 2009 59 64
-
(2009)
Clin Biomech (Bristol, Avon)
, vol.24
, Issue.1
, pp. 59-64
-
-
Windolf, M.1
Braunstein, V.2
Dutoit, C.3
Schwieger, K.4
-
11
-
-
61849155780
-
Finite element analysis of four different implants inserted in different positions to stabilize an idealized trochanteric femoral fracture
-
P. Helwig, G. Faust, U. Hindenlang, A. Hirschmuller, L. Konstantinidis, and C. Bahrs Finite element analysis of four different implants inserted in different positions to stabilize an idealized trochanteric femoral fracture Injury 40 3 2009 288 295
-
(2009)
Injury
, vol.40
, Issue.3
, pp. 288-295
-
-
Helwig, P.1
Faust, G.2
Hindenlang, U.3
Hirschmuller, A.4
Konstantinidis, L.5
Bahrs, C.6
-
12
-
-
0023869835
-
Telemetric force measurements across the hip after total arthroplasty
-
D.T. Davy, G.M. Kotzar, R.H. Brown, K.G. Heiple, V.M. Goldberg, and K.G. Heiple Jr. Telemetric force measurements across the hip after total arthroplasty J Bone Joint Surg Am 70 1 1988 45 50
-
(1988)
J Bone Joint Surg Am
, vol.70
, Issue.1
, pp. 45-50
-
-
Davy, D.T.1
Kotzar, G.M.2
Brown, R.H.3
Heiple, K.G.4
Goldberg, V.M.5
Heiple, Jr.K.G.6
-
14
-
-
0031923801
-
Postoperative weight-bearing after a fracture of the femoral neck or an intertrochanteric fracture
-
K.J. Koval, D.A. Sala, F.J. Kummer, and J.D. Zuckerman Postoperative weight-bearing after a fracture of the femoral neck or an intertrochanteric fracture J Bone Joint Surg Am 80 3 1998 352 356
-
(1998)
J Bone Joint Surg Am
, vol.80
, Issue.3
, pp. 352-356
-
-
Koval, K.J.1
Sala, D.A.2
Kummer, F.J.3
Zuckerman, J.D.4
-
15
-
-
53349146702
-
The Norwegian Hip Fracture Register: Experiences after the first 2 years and 15,576 reported operations
-
J.E. Gjertsen, L.B. Engesaeter, O. Furnes, L.I. Havelin, K. Steindal, and T. Vinje The Norwegian Hip Fracture Register: experiences after the first 2 years and 15,576 reported operations Acta Orthop 79 5 2008 583 593
-
(2008)
Acta Orthop
, vol.79
, Issue.5
, pp. 583-593
-
-
Gjertsen, J.E.1
Engesaeter, L.B.2
Furnes, O.3
Havelin, L.I.4
Steindal, K.5
Vinje, T.6
-
16
-
-
0000363188
-
Low-Angle Fixation in Fractures of the Femoral Neck
-
R.S. Garden Low-Angle Fixation in Fractures of the Femoral Neck J Bone Joint Surg Br 43 4 1961 647 663
-
(1961)
J Bone Joint Surg Br
, vol.43
, Issue.4
, pp. 647-663
-
-
Garden, R.S.1
-
17
-
-
0014836557
-
Intracapsular fractures of the neck of the femur
-
L. Klenerman, and R.W. Marcuson Intracapsular fractures of the neck of the femur J Bone Joint Surg Br 52 3 1970 514 517
-
(1970)
J Bone Joint Surg Br
, vol.52
, Issue.3
, pp. 514-517
-
-
Klenerman, L.1
Marcuson, R.W.2
-
18
-
-
61549115328
-
Posterior multifragmentation of the femoral neck: Does it portend a poor outcome in internally fixed intracapsular hip fractures?
-
S.K. Khan, A. Khanna, and M.J. Parker Posterior multifragmentation of the femoral neck: does it portend a poor outcome in internally fixed intracapsular hip fractures? Injury 40-43 2009 280 282
-
(2009)
Injury
, vol.4043
, pp. 280-282
-
-
Khan, S.K.1
Khanna, A.2
Parker, M.J.3
-
19
-
-
53549110012
-
Treatment of femoral neck fractures in young adults
-
T.V. Ly, and M.F. Swiontkowski Treatment of femoral neck fractures in young adults J Bone Joint Surg Am 90 10 2008 2254 2266
-
(2008)
J Bone Joint Surg Am
, vol.90
, Issue.10
, pp. 2254-2266
-
-
Ly, T.V.1
Swiontkowski, M.F.2
-
20
-
-
10044224621
-
Complications after intracapsular hip fractures in young adults. A meta-analysis of 18 published studies involving 564 fractures
-
D.S. Damany, M.J. Parker, and A. Chojnowski Complications after intracapsular hip fractures in young adults. A meta-analysis of 18 published studies involving 564 fractures Injury 36 1 2005 131 141
-
(2005)
Injury
, vol.36
, Issue.1
, pp. 131-141
-
-
Damany, D.S.1
Parker, M.J.2
Chojnowski, A.3
-
22
-
-
0033093073
-
Internal fixation of femoral neck fractures with posterior comminution: A biomechanical study
-
J.I. Kauffman, J.A. Simon, F.J. Kummer, C.J. Pearlman, J.D. Zuckerman, and K.J. Koval Internal fixation of femoral neck fractures with posterior comminution: a biomechanical study J Orthop Trauma 13 3 1999 155 159
-
(1999)
J Orthop Trauma
, vol.13
, Issue.3
, pp. 155-159
-
-
Kauffman, J.I.1
Simon, J.A.2
Kummer, F.J.3
Pearlman, C.J.4
Zuckerman, J.D.5
Koval, K.J.6
-
23
-
-
33748130352
-
Biomechanical analysis of the percutaneous compression plate and sliding hip screw in intracapsular hip fractures: Experimental assessment using synthetic and cadaver bones
-
E. Brandt, N. Verdonschot, A. van Vugt, and A. van Kampen Biomechanical analysis of the percutaneous compression plate and sliding hip screw in intracapsular hip fractures: experimental assessment using synthetic and cadaver bones Injury 37 10 2006 979 983
-
(2006)
Injury
, vol.37
, Issue.10
, pp. 979-983
-
-
Brandt, E.1
Verdonschot, N.2
Van Vugt, A.3
Van Kampen, A.4
-
24
-
-
0028265771
-
Implant/bone constructs in femoral neck osteotomy. An autopsy study
-
J.G. Benterud, A. Alho, and A. Hoiseth Implant/bone constructs in femoral neck osteotomy. An autopsy study Arch Orthop Trauma Surg 113 2 1994 97 100
-
(1994)
Arch Orthop Trauma Surg
, vol.113
, Issue.2
, pp. 97-100
-
-
Benterud, J.G.1
Alho, A.2
Hoiseth, A.3
-
25
-
-
84865487721
-
Side plate fixation vs. intramedullary nailing in an unstable medial femoral neck fracture model: A comparative biomechanical study
-
G. Roderer, S. Moll, F. Gebhard, L. Claes, and G. Krischak Side plate fixation vs. intramedullary nailing in an unstable medial femoral neck fracture model: a comparative biomechanical study Clin Biomech (Bristol, Avon) 2010
-
(2010)
Clin Biomech (Bristol, Avon)
-
-
Roderer, G.1
Moll, S.2
Gebhard, F.3
Claes, L.4
Krischak, G.5
-
26
-
-
84865527021
-
Biomechanical analysis of the sliding hip screw, cannulated screws and Targon((R)) FN in intracapsular hip fractures in cadaver femora
-
E. Brandt, N. Verdonschot, A. van Vugt, and A. van Kampen Biomechanical analysis of the sliding hip screw, cannulated screws and Targon((R)) FN in intracapsular hip fractures in cadaver femora Injury 2010
-
(2010)
Injury
-
-
Brandt, E.1
Verdonschot, N.2
Van Vugt, A.3
Van Kampen, A.4
-
27
-
-
35648957731
-
Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding hip screw and percutaneous compression plate
-
G.D. Krischak, P. Augat, A. Beck, M. Arand, B. Baier, and R. Blakytny Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: sliding hip screw and percutaneous compression plate Clin Biomech (Bristol, Avon) 22 10 2007 1112 1118
-
(2007)
Clin Biomech (Bristol, Avon)
, vol.22
, Issue.10
, pp. 1112-1118
-
-
Krischak, G.D.1
Augat, P.2
Beck, A.3
Arand, M.4
Baier, B.5
Blakytny, R.6
-
28
-
-
0031183549
-
Biomechanical comparison of internal fixation techniques for the treatment of unstable basicervical femoral neck fractures
-
D.A. Deneka, P.T. Simonian, C.J. Stankewich, D. Eckert, J.R. Chapman, and A.F. Tencer Biomechanical comparison of internal fixation techniques for the treatment of unstable basicervical femoral neck fractures J Orthop Trauma 11 5 1997 337 343
-
(1997)
J Orthop Trauma
, vol.11
, Issue.5
, pp. 337-343
-
-
Deneka, D.A.1
Simonian, P.T.2
Stankewich, C.J.3
Eckert, D.4
Chapman, J.R.5
Tencer, A.F.6
-
29
-
-
78650832158
-
A biomechanical comparison of two triple-screw methods for femoral neck fracture fixation in a synthetic bone model
-
R. Zdero, O. Keast-Butler, and E.H. Schemitsch A biomechanical comparison of two triple-screw methods for femoral neck fracture fixation in a synthetic bone model J Trauma 69 6 2010 1537 1544
-
(2010)
J Trauma
, vol.69
, Issue.6
, pp. 1537-1544
-
-
Zdero, R.1
Keast-Butler, O.2
Schemitsch, E.H.3
-
30
-
-
0347003735
-
Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: A biomechanical study
-
V.T. Selvan, M.J. Oakley, A. Rangan, and M.K. Al-Lami Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: a biomechanical study Injury 35 2 2004 136 141
-
(2004)
Injury
, vol.35
, Issue.2
, pp. 136-141
-
-
Selvan, V.T.1
Oakley, M.J.2
Rangan, A.3
Al-Lami, M.K.4
-
31
-
-
77952012233
-
Mechanical evaluation of large-size fourth-generation composite femur and tibia models
-
M.P. Gardner, A.C. Chong, A.G. Pollock, and P.H. Wooley Mechanical evaluation of large-size fourth-generation composite femur and tibia models Ann Biomed Eng 38 3 2010 613 620
-
(2010)
Ann Biomed Eng
, vol.38
, Issue.3
, pp. 613-620
-
-
Gardner, M.P.1
Chong, A.C.2
Pollock, A.G.3
Wooley, P.H.4
-
32
-
-
33845905793
-
Biomechanical evaluation of a new augmentation method for enhanced screw fixation in osteoporotic proximal femoral fractures
-
P. von der Linden, A. Gisep, V. Boner, M. Windolf, A. Appelt, and N. Suhm Biomechanical evaluation of a new augmentation method for enhanced screw fixation in osteoporotic proximal femoral fractures J Orthop Res 24 12 2006 2230 2237
-
(2006)
J Orthop Res
, vol.24
, Issue.12
, pp. 2230-2237
-
-
Von Der Linden, P.1
Gisep, A.2
Boner, V.3
Windolf, M.4
Appelt, A.5
Suhm, N.6
-
33
-
-
80755128919
-
Internal fixation of femoral neck fractures with posterior comminution: A biomechanical comparison of DHS(R) and Intertan nail(R)
-
M. Rupprecht, L. Grossterlinden, K. Sellenschloh, M. Hoffmann, K. Puschel, and M. Morlock Internal fixation of femoral neck fractures with posterior comminution: a biomechanical comparison of DHS(R) and Intertan nail(R) Int Orthop 2011
-
(2011)
Int Orthop
-
-
Rupprecht, M.1
Grossterlinden, L.2
Sellenschloh, K.3
Hoffmann, M.4
Puschel, K.5
Morlock, M.6
-
34
-
-
0034865876
-
Changes in proximal femoral strain after insertion of uncemented standard and customised femoral stems. An experimental study in human femora
-
A. Aamodt, J. Lund-Larsen, J. Eine, E. Andersen, P. Benum, and O.S. Husby Changes in proximal femoral strain after insertion of uncemented standard and customised femoral stems. An experimental study in human femora J Bone Joint Surg Br 83 6 2001 921 929
-
(2001)
J Bone Joint Surg Br
, vol.83
, Issue.6
, pp. 921-929
-
-
Aamodt, A.1
Lund-Larsen, J.2
Eine, J.3
Andersen, E.4
Benum, P.5
Husby, O.S.6
-
35
-
-
34548575173
-
In vitro replication of spontaneous fractures of the proximal human femur
-
L. Cristofolini, M. Juszczyk, S. Martelli, F. Taddei, and M. Viceconti In vitro replication of spontaneous fractures of the proximal human femur J Biomech 40 13 2007 2837 2845
-
(2007)
J Biomech
, vol.40
, Issue.13
, pp. 2837-2845
-
-
Cristofolini, L.1
Juszczyk, M.2
Martelli, S.3
Taddei, F.4
Viceconti, M.5
-
36
-
-
79251588445
-
Metaphyseal fracture healing follows similar biomechanical rules as diaphyseal healing
-
L. Claes, M. Reusch, M. Gockelmann, M. Ohnmacht, T. Wehner, and M. Amling Metaphyseal fracture healing follows similar biomechanical rules as diaphyseal healing J Orthop Res 29 3 2011 425 432
-
(2011)
J Orthop Res
, vol.29
, Issue.3
, pp. 425-432
-
-
Claes, L.1
Reusch, M.2
Gockelmann, M.3
Ohnmacht, M.4
Wehner, T.5
Amling, M.6
-
37
-
-
0027175806
-
Basic biomechanical measurements of bone: A tutorial
-
C.H. Turner, and D.B. Burr Basic biomechanical measurements of bone: a tutorial Bone 14 4 1993 595 608
-
(1993)
Bone
, vol.14
, Issue.4
, pp. 595-608
-
-
Turner, C.H.1
Burr, D.B.2
-
39
-
-
77958150811
-
Patient specific quantitative analysis of fracture fixation in the proximal femur implementing principal strain ratios. Method and experimental validation
-
E. Peleg, M. Beek, L. Joskowicz, M. Liebergall, R. Mosheiff, and C. Whyne Patient specific quantitative analysis of fracture fixation in the proximal femur implementing principal strain ratios. Method and experimental validation J Biomech 43 14 2010 2684 2688
-
(2010)
J Biomech
, vol.43
, Issue.14
, pp. 2684-2688
-
-
Peleg, E.1
Beek, M.2
Joskowicz, L.3
Liebergall, M.4
Mosheiff, R.5
Whyne, C.6
-
40
-
-
78049458315
-
A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in vitro tests
-
S. Eberle, C. Gerber, G. von Oldenburg, F. Hogel, and P. Augat A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in vitro tests Proc Inst Mech Eng H 224 H10 2010 1141 1152
-
(2010)
Proc Inst Mech Eng H
, vol.224
, Issue.H10
, pp. 1141-1152
-
-
Eberle, S.1
Gerber, C.2
Von Oldenburg, G.3
Hogel, F.4
Augat, P.5
-
41
-
-
0019017296
-
Investigation of load transfer and optimum pin configuration in the internal fixation, by Muller screws, of fractured femoral necks
-
J. Mizrahi, R.S. Hurlin, J.K. Taylor, and L. Solomon Investigation of load transfer and optimum pin configuration in the internal fixation, by Muller screws, of fractured femoral necks Med Biol Eng Comput 18 3 1980 319 325
-
(1980)
Med Biol Eng Comput
, vol.18
, Issue.3
, pp. 319-325
-
-
Mizrahi, J.1
Hurlin, R.S.2
Taylor, J.K.3
Solomon, L.4
-
42
-
-
47649109270
-
Finite element analysis of intramedullary devices: The effect of the gap between the implant and the bone
-
D.J. Simpson, C.J. Brown, A.L. Yettram, P. Procter, and G.J. Andrew Finite element analysis of intramedullary devices: the effect of the gap between the implant and the bone Proc Inst Mech Eng H 222 3 2008 333 345
-
(2008)
Proc Inst Mech Eng H
, vol.222
, Issue.3
, pp. 333-345
-
-
Simpson, D.J.1
Brown, C.J.2
Yettram, A.L.3
Procter, P.4
Andrew, G.J.5
-
43
-
-
0029715338
-
Relationship of mechanical factors to the strength of proximal femur fractures fixed with cancellous screws
-
C.J. Stankewich, J. Chapman, R. Muthusamy, G. Quaid, E. Schemitsch, and A.F. Tencer Relationship of mechanical factors to the strength of proximal femur fractures fixed with cancellous screws J Orthop Trauma 10 4 1996 248 257
-
(1996)
J Orthop Trauma
, vol.10
, Issue.4
, pp. 248-257
-
-
Stankewich, C.J.1
Chapman, J.2
Muthusamy, R.3
Quaid, G.4
Schemitsch, E.5
Tencer, A.F.6
-
44
-
-
67949112753
-
Type of hip fracture determines load share in intramedullary osteosynthesis
-
S. Eberle, C. Gerber, G. von Oldenburg, S. Hungerer, and P. Augat Type of hip fracture determines load share in intramedullary osteosynthesis Clin Orthop Relat Res 467 8 2009 1972 1980
-
(2009)
Clin Orthop Relat Res
, vol.467
, Issue.8
, pp. 1972-1980
-
-
Eberle, S.1
Gerber, C.2
Von Oldenburg, G.3
Hungerer, S.4
Augat, P.5
-
45
-
-
0035226309
-
Internal fixation implants for intracapsular proximal femoral fractures in adults
-
M.J. Parker, and G. Stockton Internal fixation implants for intracapsular proximal femoral fractures in adults Cochrane Database Syst Rev 4 2001 CD001467
-
(2001)
Cochrane Database Syst Rev
, vol.4
, pp. 001467
-
-
Parker, M.J.1
Stockton, G.2
-
46
-
-
0030131155
-
Mechanical validation of whole bone composite femur models
-
L. Cristofolini, M. Viceconti, A. Cappello, and A. Toni Mechanical validation of whole bone composite femur models J Biomech 29 4 1996 525 535
-
(1996)
J Biomech
, vol.29
, Issue.4
, pp. 525-535
-
-
Cristofolini, L.1
Viceconti, M.2
Cappello, A.3
Toni, A.4
-
47
-
-
33645310414
-
Does screw configuration affect subtrochanteric fracture after femoral neck fixation?
-
J.W. Oakey, M.D. Stover, H.D. Summers, M. Sartori, R.M. Havey, and A.G. Patwardhan Does screw configuration affect subtrochanteric fracture after femoral neck fixation? Clin Orthop Relat Res 443 2006 302 306
-
(2006)
Clin Orthop Relat Res
, vol.443
, pp. 302-306
-
-
Oakey, J.W.1
Stover, M.D.2
Summers, H.D.3
Sartori, M.4
Havey, R.M.5
Patwardhan, A.G.6
|