메뉴 건너뛰기




Volumn 39, Issue 8, 2012, Pages 4875-4885

On the output factor measurements of the CyberKnife iris collimator small fields: Experimental determination of the kQclin, Qmsr fclin, f msr correction factors for microchamber and diode detectors

Author keywords

correction factor; CyberKnife; output factor; polymer gel; small fields

Indexed keywords

AMINO ACIDS; DOSIMETERS; MICROCHANNELS; POLYMER FILMS;

EID: 84864692059     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4736810     Document Type: Article
Times cited : (62)

References (37)
  • 2
    • 37549052531 scopus 로고    scopus 로고
    • Small fields: Nonequilibrium radiation dosimetry
    • 10.1118/1.2815356
    • I. J. Das, G. X. Ding, and A. Ahnesjo, Small fields: Nonequilibrium radiation dosimetry., Med. Phys. 35, 206-215 (2008). 10.1118/1.2815356
    • (2008) Med. Phys. , vol.35 , pp. 206-215
    • Das, I.J.1    Ding, G.X.2    Ahnesjo, A.3
  • 3
    • 70350741707 scopus 로고    scopus 로고
    • Determination of output factors for stereotactic radiosurgery beams
    • 10.1118/1.3232217
    • J. Fan, K. Paskalev, L. Wang, L. Jin, J. Li, A. Eldeeb, and C. Ma, Determination of output factors for stereotactic radiosurgery beams., Med. Phys. 36, 5292-5300 (2009). 10.1118/1.3232217
    • (2009) Med. Phys. , vol.36 , pp. 5292-5300
    • Fan, J.1    Paskalev, K.2    Wang, L.3    Jin, L.4    Li, J.5    Eldeeb, A.6    Ma, C.7
  • 4
    • 0031956451 scopus 로고    scopus 로고
    • Use of a new type of radiochromic film, a new parallel-plate micro- chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beams
    • DOI 10.1118/1.598227
    • P. Francescon, S. Cora, C. Cavedon, P. Scalchi, S. Reccanello, and F. Colombo, Use of a new type of radiochromic film, a new parallel-plate micro-chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beams., Med. Phys. 25, 503-511 (1998). 10.1118/1.598227 (Pubitemid 28178358)
    • (1998) Medical Physics , vol.25 , Issue.4 , pp. 503-511
    • Francescon, P.1    Cora, S.2    Cavedon, C.3    Scalchi, P.4    Reccanello, S.5    Colombo, F.6
  • 5
    • 0030026160 scopus 로고    scopus 로고
    • A comparison of dosimetry techniques in stereotactic radiosurgery
    • DOI 10.1088/0031-9155/41/1/008
    • M. Heydarian, P. W. Hoban, and A. H. Beddoe, A comparison of dosimetry techniques in stereotactic radiosurgery., Phys. Med. Biol. 41, 93-110 (1996). 10.1088/0031-9155/41/1/008 (Pubitemid 26034227)
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.1 , pp. 93-110
    • Heydarian, M.1    Hoban, P.W.2    Beddoe, A.H.3
  • 6
    • 0037339773 scopus 로고    scopus 로고
    • The volume effect of detectors in the dosimetry of small fields used in IMRT
    • DOI 10.1118/1.1544678
    • W. U. Laub and T. Wong, The volume effect of detectors in the dosimetry of small fields used in IMRT., Med. Phys. 30, 341-347 (2003). 10.1118/1.1544678 (Pubitemid 36337100)
    • (2003) Medical Physics , vol.30 , Issue.3 , pp. 341-347
    • Lauba, W.U.1    Wong, T.2
  • 9
    • 34447336432 scopus 로고    scopus 로고
    • Measurement of output factors for small photon beams
    • DOI 10.1118/1.2734383
    • O. A. Sauer and J. Wilbert, Measurement of output factors for small photon beams., Med. Phys. 34, 1983-1988 (2007). 10.1118/1.2734383 (Pubitemid 47055733)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 1983-1988
    • Sauer, O.A.1    Wilbert, J.2
  • 10
    • 0034063760 scopus 로고    scopus 로고
    • Total scatter factors and tissue maximum ratios for small radiosurgery fields: Comparison of diode detectors, a parallel-plate ion chamber, and radiographic film
    • DOI 10.1118/1.598915
    • X. R. Zhu, J. J. Allen, J. Shi, and W. E. Simon, Total scatter factors and tissue maximum ratios for small radiosurgery fields: Comparison of diode detectors, a parallel-plate ion chamber, and radiographic film., Med. Phys. 27, 472-477 (2000). 10.1118/1.598915 (Pubitemid 30171795)
    • (2000) Medical Physics , vol.27 , Issue.3 , pp. 472-477
    • Zhu, X.R.1    Allen, J.J.2    Shi, J.3    Simon, W.E.4
  • 11
    • 0034065594 scopus 로고    scopus 로고
    • Comparative dosimetry in narrow high-energy photon beams
    • DOI 10.1088/0031-9155/45/3/308, PII S0031915500086930
    • M. Westermark, J. Arndt, B. Nilsson, and A. Brahme, Comparative dosimetry in narrow high-energy photon beams., Phys. Med. Biol. 45, 685-702 (2000). 10.1088/0031-9155/45/3/308 (Pubitemid 30163657)
    • (2000) Physics in Medicine and Biology , vol.45 , Issue.3 , pp. 685-702
    • Westermark, M.1    Arndt, J.2    Nilsson, B.3    Brahme, A.4
  • 12
    • 38849151519 scopus 로고    scopus 로고
    • Total scatter factors of small beams: A multidetector and Monte Carlo study
    • DOI 10.1118/1.2828195
    • P. Francescon, S. Cora, and C. Cavedon, Total scatter factors of small beams: A multidetector and Monte Carlo study., Med. Phys. 35, 504-513 (2008). 10.1118/1.2828195 (Pubitemid 351190870)
    • (2008) Medical Physics , vol.35 , Issue.2 , pp. 504-513
    • Francescon, P.1    Cora, S.2    Cavedon, C.3
  • 13
    • 70049102550 scopus 로고    scopus 로고
    • Application of a Monte Carlo-based method for total scatter factors of small beams to new solid state micro-detectors
    • P. Francescon, S. Cora, C. Cavedon, and P. Scalchi, Application of a Monte Carlo-based method for total scatter factors of small beams to new solid state micro-detectors., J. Appl. Clin. Med. Phys. 10, 147-152 (2009).
    • (2009) J. Appl. Clin. Med. Phys. , vol.10 , pp. 147-152
    • Francescon, P.1    Cora, S.2    Cavedon, C.3    Scalchi, P.4
  • 15
    • 70349658748 scopus 로고    scopus 로고
    • Ionization chamber gradient effects in nonstandard beam configurations
    • 10.1118/1.3213518
    • H. Bouchard, J. Seuntjens, J. F. Carrier, and I. Kawrakow, Ionization chamber gradient effects in nonstandard beam configurations., Med. Phys. 36, 4654-4663 (2009). 10.1118/1.3213518
    • (2009) Med. Phys. , vol.36 , pp. 4654-4663
    • Bouchard, H.1    Seuntjens, J.2    Carrier, J.F.3    Kawrakow, I.4
  • 16
    • 79953689907 scopus 로고    scopus 로고
    • A Monte Carlo method to evaluate the impact of positioning errors on detector response and quality correction factors in nonstandard beams
    • 10.1088/0031-9155/56/8/018
    • H. Bouchard, J. Seuntjens, and I. Kawrakow, A Monte Carlo method to evaluate the impact of positioning errors on detector response and quality correction factors in nonstandard beams., Phys. Med. Biol. 56, 2617-2634 (2011). 10.1088/0031-9155/56/8/018
    • (2011) Phys. Med. Biol. , vol.56 , pp. 2617-2634
    • Bouchard, H.1    Seuntjens, J.2    Kawrakow, I.3
  • 17
    • 52949151876 scopus 로고    scopus 로고
    • Using a Monte Carlo model to predict dosimetric properties of small radiotherapy photon fields
    • 10.1118/1.2975223
    • A. J. Scott, A. E. Nahum, and J. D. Fenwick, Using a Monte Carlo model to predict dosimetric properties of small radiotherapy photon fields., Med. Phys. 35, 4671-4684 (2008). 10.1118/1.2975223
    • (2008) Med. Phys. , vol.35 , pp. 4671-4684
    • Scott, A.J.1    Nahum, A.E.2    Fenwick, J.D.3
  • 19
    • 82755181817 scopus 로고    scopus 로고
    • Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors
    • 10.1118/1.3658572
    • G. Cranmer-Sargison, S. Weston, J. A. Evans, N. P. Sidhu, and D. I. Thwaites, Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors., Med. Phys. 38, 6592-6602 (2011). 10.1118/1.3658572
    • (2011) Med. Phys. , vol.38 , pp. 6592-6602
    • Cranmer-Sargison, G.1    Weston, S.2    Evans, J.A.3    Sidhu, N.P.4    Thwaites, D.I.5
  • 22
    • 0034023628 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulations
    • DOI 10.1118/1.598918
    • I. Kawrakow, Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulations., Med. Phys. 27, 499-513 (2000). 10.1118/1.598918 (Pubitemid 30171798)
    • (2000) Medical Physics , vol.27 , Issue.3 , pp. 499-513
    • Kawrakow, I.1
  • 23
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • DOI 10.1118/1.598917
    • I. Kawrakow, Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version., Med. Phys. 27, 485-498 (2000). 10.1118/1.598917 (Pubitemid 30171797)
    • (2000) Medical Physics , vol.27 , Issue.3 , pp. 485-498
    • Kawrakow, I.1
  • 24
    • 67649625514 scopus 로고    scopus 로고
    • Monte Carlo modeling of small photon fields: Quantifying the impact of focal spot size on source occlusion and output factors, and exploring miniphantom design for small-field measurements
    • 10.1118/1.3152866
    • A. J. Scott, A. E. Nahum, and J. D. Fenwick, Monte Carlo modeling of small photon fields: Quantifying the impact of focal spot size on source occlusion and output factors, and exploring miniphantom design for small-field measurements., Med. Phys. 36, 3132-3144 (2009). 10.1118/1.3152866
    • (2009) Med. Phys. , vol.36 , pp. 3132-3144
    • Scott, A.J.1    Nahum, A.E.2    Fenwick, J.D.3
  • 25
    • 78149290698 scopus 로고    scopus 로고
    • Investigation of systematic uncertainties in Monte Carlo-calculated beam quality correction factors
    • 10.1088/0031-9155/55/16/S04
    • J. Wulff, J. T. Heverhagen, K. Zink, and I. Kawrakow, Investigation of systematic uncertainties in Monte Carlo-calculated beam quality correction factors., Phys. Med. Biol. 55, 4481-4493 (2010). 10.1088/0031-9155/55/16/S04
    • (2010) Phys. Med. Biol. , vol.55 , pp. 4481-4493
    • Wulff, J.1    Heverhagen, J.T.2    Zink, K.3    Kawrakow, I.4
  • 27
    • 51849098609 scopus 로고    scopus 로고
    • Performance evaluation of a CyberKnife G4 image-guided robotic stereotactic radiosurgery system
    • 10.1088/0031-9155/53/17/016
    • C. Antypas and E. Pantelis, Performance evaluation of a CyberKnife G4 image-guided robotic stereotactic radiosurgery system., Phys. Med. Biol. 53, 4697-4718 (2008). 10.1088/0031-9155/53/17/016
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4697-4718
    • Antypas, C.1    Pantelis, E.2
  • 33
  • 34
    • 71049114250 scopus 로고    scopus 로고
    • Characterization of a new polymer gel for radiosurgery dosimetry using magnetic resonance imaging
    • 10.1088/1748-0221/4/06/P06018
    • L. Petrokokkinos, M. Kozicki, E. Pantelis, C. Antypas, J. Fijuth, P. Karaiskos, L. Sakelliou, and I. Seimenis, Characterization of a new polymer gel for radiosurgery dosimetry using magnetic resonance imaging., J. Instrum. 4, P06018 (2009). 10.1088/1748-0221/4/06/P06018
    • (2009) J. Instrum. , vol.4 , pp. 06018
    • Petrokokkinos, L.1    Kozicki, M.2    Pantelis, E.3    Antypas, C.4    Fijuth, J.5    Karaiskos, P.6    Sakelliou, L.7    Seimenis, I.8
  • 36
    • 0032178596 scopus 로고    scopus 로고
    • Mathematical analysis and experimental investigation of noise in quantitative magnetic resonance imaging applied in polymer gel dosimetry
    • PII S0165168498001157
    • Y. De Deene, R. Van de Walle, E. Achten, and C. De Wagter, Mathematical analysis and experimental investigation of noise in quantitative magnetic resonance imaging applied in polymer gel dosimetry., Signal Process. 70, 85-101 (1998). 10.1016/S0165-1684(98)00115-7 (Pubitemid 128421085)
    • (1998) Signal Processing , vol.70 , Issue.2 , pp. 85-101
    • De Deene, Y.1    Van De Walle, R.2    Achten, E.3    De Wagter, C.4
  • 37
    • 84862001085 scopus 로고    scopus 로고
    • Monte Carlo simulated correction factors for machine specific reference field dose calibration and output factor measurement using fixed and iris collimators on the CyberKnife system
    • 10.1088/0031-9155/57/12/3741
    • P. Francescon, W. Kilby, N. Satariano, and S. Cora, Monte Carlo simulated correction factors for machine specific reference field dose calibration and output factor measurement using fixed and iris collimators on the CyberKnife system., Phys. Med. Biol. 57, 3741-3758 (2012). 10.1088/0031-9155/57/12/3741
    • (2012) Phys. Med. Biol. , vol.57 , pp. 3741-3758
    • Francescon, P.1    Kilby, W.2    Satariano, N.3    Cora, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.