메뉴 건너뛰기




Volumn 36, Issue 11, 2009, Pages 5292-5300

Determination of output factors for stereotactic radiosurgery beams

Author keywords

Output factor; Scan beam scan chamber method; Small field dosimetry; Trilogy

Indexed keywords

DOSIMETRY; INTERACTIVE COMPUTER SYSTEMS; IONIZATION CHAMBERS; RADIOTHERAPY; SCANNING; UNCERTAINTY ANALYSIS;

EID: 70350741707     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3232217     Document Type: Article
Times cited : (38)

References (18)
  • 1
    • 21144432528 scopus 로고    scopus 로고
    • Relative output factor measurements of a 5 mm diameter radiosurgical photon beam using polymer gel dosimetry
    • DOI 10.1118/1.1916048
    • E. Pappas, L. Petrokokkinos, A. Angelopoulos, T. G. Maris, M. Kozicki, I. Dalezios, and V. Kouloulias, " Relative output factor measurements of a 5 mm diameter radiosurgical photon beam using polymer gel dosimetry.," Med. Phys. 32, 1513-1521 (2005). 10.1118/1.1916048 (Pubitemid 40880542)
    • (2005) Medical Physics , vol.32 , Issue.6 , pp. 1513-1520
    • Pappas, E.1    Petrokokkinos, L.2    Angelopoulos, A.3    Maris, T.G.4    Kozicki, M.5    Dalezios, I.6    Kouloulias, V.7
  • 2
    • 0032829872 scopus 로고    scopus 로고
    • Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition
    • DOI 10.1088/0031-9155/44/9/303, PII S0031915599005382
    • C. McKerracher and D. I. Thwaites, " Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition.," Phys. Med. Biol. 44, 2143-2160 (1999). 10.1088/0031-9155/44/ 9/303 (Pubitemid 29424376)
    • (1999) Physics in Medicine and Biology , vol.44 , Issue.9 , pp. 2143-2160
    • McKerracher, C.1    Thwaites, D.I.2
  • 3
    • 33749839277 scopus 로고    scopus 로고
    • Limitations of silicon diodes for clinical electron dosimetry
    • DOI 10.1093/rpd/ncj007
    • H. Song, M. Ahmad, J. Deng, Z. Chen, N. J. Yue, and R. Nath, " Limitations of silicon diodes for clinical electron dosimetry.," Radiat. Prot. Dosim. 120, 56-59 (2006). 10.1093/rpd/ncj007 (Pubitemid 44559987)
    • (2006) Radiation Protection Dosimetry , vol.120 , Issue.1-4 , pp. 56-59
    • Song, H.1    Ahmad, M.2    Deng, J.3    Chen, Z.4    Yue, N.J.5    Nath, R.6
  • 4
    • 34247626996 scopus 로고    scopus 로고
    • Energy dependence of commercially available diode detectors for in-vivo dosimetry
    • DOI 10.1118/1.2719365
    • A. S. Saini and T. C. Zhu, " Energy dependence of commercially available diode detectors for in-vivo dosimetry.," Med. Phys. 34, 1704-1711 (2007). 10.1118/1.2719365 (Pubitemid 46669165)
    • (2007) Medical Physics , vol.34 , Issue.5 , pp. 1704-1711
    • Saini, A.S.1    Zhu, T.C.2
  • 5
    • 21144456660 scopus 로고    scopus 로고
    • Application of a radiophotoluminescent glass plate dosimeter for small field dosimetry
    • DOI 10.1118/1.1925187
    • F. Aaki, T. Ishidoya, T. Ikegami, N. Moribe, and Y. Yamashita, " Application of a radiophotoluminescent glass plate dosimeter for small field dosimetry.," Med. Phys. 32, 1548-1554 (2005). 10.1118/1.1925187 (Pubitemid 40880548)
    • (2005) Medical Physics , vol.32 , Issue.6 , pp. 1548-1554
    • Aaki, F.1    Ishidoya, T.2    Ikegami, T.3    Moribe, N.4    Yamashita, Y.5
  • 6
    • 4444263965 scopus 로고    scopus 로고
    • Response corrections for solid-state detectors in megavoltage photon dosimetry
    • DOI 10.1088/0031-9155/49/16/015, PII S0031915504785395
    • Z. Yin, R. P. Hugtenburg, and A. H. Beddoe, " Response corrections for solid-state detectors in megavoltage photon dosimetry.," Phys. Med. Biol. 49, 3691-3702 (2004). 10.1088/0031-9155/49/16/015 (Pubitemid 39206450)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.16 , pp. 3691-3702
    • Yin, Z.1    Hugtenburg, R.P.2    Beddoe, A.H.3
  • 7
    • 0037323117 scopus 로고    scopus 로고
    • Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and 3 mm in diameter)
    • DOI 10.1118/1.1536290
    • K. A. Paskalev, J. P. Seuntjens, H. J. Patrocinio, and E. B. Podgorsak, " Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and 3 mm in diameter).," Med. Phys. 30, 111-118 (2003). 10.1118/1.1536290 (Pubitemid 36222845)
    • (2003) Medical Physics , vol.30 , Issue.2 , pp. 111-118
    • Paskalev, K.A.1    Seuntjens, J.P.2    Patrocinio, H.J.3    Podgorsak, E.B.4
  • 8
    • 0037339773 scopus 로고    scopus 로고
    • The volume effect of detectors in the dosimetry of small fields used in IMRT
    • DOI 10.1118/1.1544678
    • W. U. Laub and T. Wong, " The volume effect of detectors in the dosimetry of small fields used in IMRT.," Med. Phys. 30, 341-347 (2003). 10.1118/1.1544678 (Pubitemid 36337100)
    • (2003) Medical Physics , vol.30 , Issue.3 , pp. 341-347
    • Lauba, W.U.1    Wong, T.2
  • 9
    • 0036168784 scopus 로고    scopus 로고
    • An investigation of the operating characteristics of two PTW diamond detectors in photon and electron beams
    • DOI 10.1118/1.1446101
    • C. D. Angelis, S. Onori, M. Pacilio, G. A. Cirrone, G. Cuttone, L. Raffaele, M. Bucciolini, and S. Mazzocchi, " An investigation of the operating characteristics of two PTW diamond detectors in photon and electron beams.," Med. Phys. 29, 248-254 (2002). 10.1118/1.1446101 (Pubitemid 34157997)
    • (2002) Medical Physics , vol.29 , Issue.2 , pp. 248-254
    • De Angelis, C.1    Onori, S.2    Pacilio, M.3    Cirrone, G.A.P.4    Cuttone, G.5    Raffaele, L.6    Bucciolini, M.7    Mazzocchi, S.8
  • 10
    • 0033795118 scopus 로고    scopus 로고
    • The value of the PinPoint ion chamber for characterization of small field segments used in intensity modulated radiotherapy
    • 10.1088/0031-9155/45/9/306
    • C. Martens, C. D. Wagter, and W. De Neve, " The value of the PinPoint ion chamber for characterization of small field segments used in intensity modulated radiotherapy.," Phys. Med. Biol. 45, 2519-2530 (2000). 10.1088/0031-9155/45/9/306
    • (2000) Phys. Med. Biol. , vol.45 , pp. 2519-2530
    • Martens, C.1    Wagter, C.D.2    De Neve, W.3
  • 11
    • 0031956451 scopus 로고    scopus 로고
    • Use of a new type of radiochromic film, a new parallel-plate micro- chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beams
    • DOI 10.1118/1.598227
    • P. Francescon, S. Cora, C. Cavedon, P. Scalchi, S. Reccanello, and F. Colombo, " Use of a new type of radiochromic film, a new parallel-plate micro-chamber, MOSFETs and TLD 800 microcubes in the dosimetry of small beams.," Med. Phys. 25, 503-511 (1998). 10.1118/1.598227 (Pubitemid 28178358)
    • (1998) Medical Physics , vol.25 , Issue.4 , pp. 503-511
    • Francescon, P.1    Cora, S.2    Cavedon, C.3    Scalchi, P.4    Reccanello, S.5    Colombo, F.6
  • 12
    • 34447336432 scopus 로고    scopus 로고
    • Measurement of output factors for small photon beams
    • DOI 10.1118/1.2734383
    • O. A. Sauer and J. Wilbert, " Measurement of output factors for small photon beams.," Med. Phys. 34, 1983-1988 (2007). 10.1118/1.2734383 (Pubitemid 47055733)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 1983-1988
    • Sauer, O.A.1    Wilbert, J.2
  • 14
    • 0030026160 scopus 로고    scopus 로고
    • A comparison of dosimetry techniques in stereotactic radiosurgery
    • DOI 10.1088/0031-9155/41/1/008
    • M. Heydarian, P. W. Hoban, and A. H. Beddoe, " A comparison of dosimetry techniques in stereotactic radiosurgery.," Phys. Med. Biol. 41, 93-110 (1996). 10.1088/0031-9155/41/1/008 (Pubitemid 26034227)
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.1 , pp. 93-110
    • Heydarian, M.1    Hoban, P.W.2    Beddoe, A.H.3
  • 16
    • 27644471150 scopus 로고    scopus 로고
    • Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range
    • DOI 10.1016/j.apradiso.2005.07.002, PII S0969804305002332
    • M. J. Butson, T. Cheung, and P. K. N. Yu, " Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp x-ray range.," Appl. Radiat. Isot. 64, 60-62 (2006). 10.1016/j.apradiso.2005.07.002 (Pubitemid 41550172)
    • (2006) Applied Radiation and Isotopes , vol.64 , Issue.1 , pp. 60-62
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.N.3
  • 18
    • 33749387201 scopus 로고    scopus 로고
    • Experimental determination of the effect of detector size on profile measurements in narrow photon beams
    • DOI 10.1118/1.2349691
    • E. Pappas, T. G. Maris, A. Papadakis, F. Zacharopoulou, J. Damilakis, N. Papanikolaou, and N. Gourtsoyiannis, " Experimental determination of the effect of detector size on profile measurements in narrow photon beams.," Med. Phys. 33, 3700-3710 (2006). 10.1118/1.2349691 (Pubitemid 44505096)
    • (2006) Medical Physics , vol.33 , Issue.10 , pp. 3700-3710
    • Pappas, E.1    Maris, T.G.2    Papadakis, A.3    Zacharopoulou, F.4    Damilakis, J.5    Papanikolaou, N.6    Gourtsoyiannis, N.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.