메뉴 건너뛰기




Volumn 36, Issue 10, 2009, Pages 4654-4663

Ionization chamber gradient effects in nonstandard beam configurations

Author keywords

Dosimetry; IMRT; Ionization chamber; Monte Carlo; Perturbation

Indexed keywords

DOSIMETRY; IONIZATION; IONIZATION CHAMBERS; QUALITY ASSURANCE; RADIOTHERAPY;

EID: 70349658748     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3213518     Document Type: Article
Times cited : (80)

References (35)
  • 1
    • 70349676507 scopus 로고
    • Code of practice for x-ray measurements
    • HPA, "," ().
    • HPA, " Code of practice for x-ray measurements.," Phys. Vib. 33 (55), 55-59 (1960).
    • (1960) Phys. Vib. , vol.33 , Issue.55 , pp. 55-59
  • 2
    • 33745513754 scopus 로고
    • A code of practice for the dosimetry of 2 to 8 MV x-ray and caesium-137 and cobalt-60 gamma-ray beams
    • HPA, "," (),. 10.1088/0031-9155/9/4/302
    • HPA, " A code of practice for the dosimetry of 2 to 8 MV x-ray and caesium-137 and cobalt-60 gamma-ray beams.," Phys. Med. Biol. 9 (4), 457-463 (1964). 10.1088/0031-9155/9/4/302
    • (1964) Phys. Med. Biol. , vol.9 , Issue.4 , pp. 457-463
  • 3
    • 0013955423 scopus 로고
    • Protocol for the dosimetry of high energy electrons
    • AAPM (SCRAD), "," (),. 10.1088/0031-9155/11/4/301
    • AAPM (SCRAD), " Protocol for the dosimetry of high energy electrons.," Phys. Med. Biol. 11 (4), 505-520 (1966). 10.1088/0031-9155/11/ 4/301
    • (1966) Phys. Med. Biol. , vol.11 , Issue.4 , pp. 505-520
  • 4
    • 0014459732 scopus 로고
    • A code of practice for the dosimetry of 2 to 35 MV x-ray and caesium-137 and cobalt-60 gamma-ray beams
    • HPA, "," (),. 10.1088/0031-9155/14/1/001
    • HPA, " A code of practice for the dosimetry of 2 to 35 MV x-ray and caesium-137 and cobalt-60 gamma-ray beams.," Phys. Med. Biol. 14 (1), 1-8 (1969). 10.1088/0031-9155/14/1/001
    • (1969) Phys. Med. Biol. , vol.14 , Issue.1 , pp. 1-8
  • 6
    • 0015092562 scopus 로고
    • Protocol for the dosimetry of x- and gamma beams with maximum energies between 0.6 and 50 MeV
    • AAPM (SCRAD), "," (),. 10.1088/0031-9155/16/3/301
    • AAPM (SCRAD), " Protocol for the dosimetry of x- and gamma beams with maximum energies between 0.6 and 50 MeV.," Phys. Med. Biol. 16 (3), 379-396 (1971). 10.1088/0031-9155/16/3/301
    • (1971) Phys. Med. Biol. , vol.16 , Issue.3 , pp. 379-396
  • 7
    • 84907107154 scopus 로고
    • Procedures in radiation therapy dosimetry with 5 to 50 MeV electrons and roentgen and gamma rays with maximum photon energies between 1 and 50 MeV
    • NACP, "," ().
    • NACP, " Procedures in radiation therapy dosimetry with 5 to 50 MeV electrons and roentgen and gamma rays with maximum photon energies between 1 and 50 MeV.," Acta Radiol. Ther. Phys. Biol. 2 (6), 603-624 (1972).
    • (1972) Acta Radiol. Ther. Phys. Biol. , vol.2 , Issue.6 , pp. 603-624
  • 9
    • 0016686841 scopus 로고
    • Code of practice for x-ray therapy linear accelerators
    • AAPM, "," (),. 10.1118/1.594133
    • AAPM, " Code of practice for x-ray therapy linear accelerators.," Med. Phys. 2 (10), 110-121 (1975). 10.1118/1.594133
    • (1975) Med. Phys. , vol.2 , Issue.10 , pp. 110-121
  • 10
    • 0018823003 scopus 로고
    • Procedures in external radiation therapy dosimetry with electron and photon beams with maximum energies between 1 and 50 MeV
    • NACP
    • NACP, " Procedures in external radiation therapy dosimetry with electron and photon beams with maximum energies between 1 and 50 MeV.," Acta Radiol. Oncol. 19, 58-77 (1980).
    • (1980) Acta Radiol. Oncol. , vol.19 , pp. 58-77
  • 11
    • 0021062111 scopus 로고
    • A protocol for the determination of absorbed dose from high-energy photon and electron beams
    • DOI 10.1118/1.595446
    • AAPM Task Group 21 Radiation Therapy Committee, " A protocol for the determination of absorbed dose from high-energy photon and electron beams.," Med. Phys. 10 (6), 741-771 (1983). 10.1118/1.595446 (Pubitemid 14216123)
    • (1983) Medical Physics , vol.10 , Issue.6 , pp. 741-771
    • Schulz, R.J.1    Almond, P.R.2    Cunningham, J.R.3
  • 13
    • 0032874911 scopus 로고    scopus 로고
    • AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    • DOI 10.1118/1.598691
    • P. R. Almond, P. J. Biggs, B. M. Coursey, W. F. Hanson, M. S. Huq, R. Nath, and D. W. O. Rogers, " AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams.," Med. Phys. 26 (9), 1847-1869 (1999). 10.1118/1.598691 (Pubitemid 29442268)
    • (1999) Medical Physics , vol.26 , Issue.9 , pp. 1847-1870
    • Almond, P.R.1    Biggs, P.J.2    Coursey, B.M.3    Hanson, W.F.4    Huq, M.S.5    Nath, R.6    Rogers, D.W.O.7
  • 15
    • 0003651542 scopus 로고
    • International Commission on Radiation Units and Measurements, "," ICRU Report No. 50.
    • International Commission on Radiation Units and Measurements, " Prescribing, Recording, and Reporting Photon Beam Therapy.," ICRU Report No. 50, 1993.
    • (1993) Prescribing, Recording, and Reporting Photon Beam Therapy
  • 16
    • 0003982209 scopus 로고
    • International Commission on Radiation Units and Measurements, "," ICRU Report No. 33.
    • International Commission on Radiation Units and Measurements, " Radiation Quantities and Units.," ICRU Report No. 33, 1980.
    • (1980) Radiation Quantities and Units
  • 17
    • 33744828302 scopus 로고    scopus 로고
    • On the effective point of measurement in megavoltage photon beams
    • DOI 10.1118/1.2201147
    • I. Kawrakow, " On the effective point of measurement in megavoltage photon beams.," Med. Phys. 33 (6), 1829-1839 (2006). 10.1118/1.2201147 (Pubitemid 43830271)
    • (2006) Medical Physics , vol.33 , Issue.6 , pp. 1829-1839
    • Kawrakow, I.1
  • 18
    • 40049109564 scopus 로고    scopus 로고
    • The effective point of measurement of ionization chambers and the build-up anomaly in MV x-ray beams
    • DOI 10.1118/1.2839329
    • M. R. McEwen, I. Kawrakow, and C. K. Ross, " The effective point of measurement of ionization chambers and the build-up anomaly in MV x-ray beams.," Med. Phys. 35 (3), 950-958 (2008). 10.1118/1.2839329 (Pubitemid 351322676)
    • (2008) Medical Physics , vol.35 , Issue.3 , pp. 950-958
    • McEwen, M.R.1    Kawrakow, I.2    Ross, C.K.3
  • 19
    • 4644295340 scopus 로고    scopus 로고
    • Ionization chamber-based reference dosimetry of intensity modulated radiation beams
    • DOI 10.1118/1.1781333
    • H. Bouchard and J. Seuntjens, " Ionization chamber-based reference dosimetry of intensity modulated radiation beams.," Med. Phys. 31 (9), 2454-5465 (2004). 10.1118/1.1781333 (Pubitemid 39287859)
    • (2004) Medical Physics , vol.31 , Issue.9 , pp. 2454-2465
    • Bouchard, H.1    Seuntjens, J.2
  • 20
    • 4644300643 scopus 로고    scopus 로고
    • An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets
    • DOI 10.1118/1.1767691
    • R. Capote, F. Sánchez-Doblado, A. Leal, J. I. Lagares, R. Arráns, and G. H. Hartmann, " An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets.," Med. Phys. 31 (9), 2416-2422 (2004). 10.1118/1.1767691 (Pubitemid 39287855)
    • (2004) Medical Physics , vol.31 , Issue.9 , pp. 2416-2422
    • Capote, R.1    Sanchez-Doblado, F.2    Leal, A.3    Lagares, J.I.4    Arrans, R.5    Hartmann, G.H.6
  • 21
    • 10744230395 scopus 로고    scopus 로고
    • Ionization chamber dosimetry of small photon fields: A Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams
    • DOI 10.1088/0031-9155/48/14/304, PII S0031915503611528
    • F. Sanchez-Doblado, P. Andreo, R. Capote, A. Leal, M. Perucha, R. Arrans, L. Nunez, E. Mainegra, J. I. Lagares, and E. Carrasco, " Ionization chamber dosimetry of small photon fields: A Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams.," Phys. Med. Biol. 48 (14), 2081-2099 (2003). 10.1088/0031-9155/48/14/304 (Pubitemid 36926702)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.14 , pp. 2081-2099
    • Sanchez-Doblado, F.1    Andreo, P.2    Capote, R.3    Leal, A.4    Perucha, M.5    Arrans, R.6    Nunez, L.7    Mainegra, E.8    Lagares, J.I.9    Carrasco, E.10
  • 23
    • 31844450298 scopus 로고    scopus 로고
    • wall, for thimble ionization chambers
    • DOI 10.1118/1.2161403
    • wall, for thimble ionization chambers.," Med. Phys. 33 (2), 455-464 (2006). 10.1118/1.2161403 (Pubitemid 43183990)
    • (2006) Medical Physics , vol.33 , Issue.2 , pp. 455-464
    • Buckley, L.A.1    Rogers, D.W.O.2
  • 24
    • 45749111374 scopus 로고    scopus 로고
    • Monte-Carlo-based perturbation and beam quality correction factors for thimble ionization chambers in high-energy photon beams
    • DOI 10.1088/0031-9155/53/11/005, PII S0031915508724370
    • J. Wulff, J. T. Heverhagen, and K. Zink, " Monte-Carlo-based perturbation and beam quality correction factors for thimble ionization chambers in high-energy photon beams.," Phys. Med. Biol. 53 (11), 2823-2836 (2008). 10.1088/0031-9155/53/11/005 (Pubitemid 351868608)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11 , pp. 2823-2836
    • Wulff, J.1    Heverhagen, J.T.2    Zink, K.3
  • 25
    • 67649892570 scopus 로고    scopus 로고
    • The influence of small field sizes, penumbra, spot size and measurement depth on perturbation factors for microionization chambers
    • 10.1088/0031-9155/54/9/024
    • F. Crop, N. Reynaert, G. Pittomvils, L. Paelinck, C. De Wagter, L. Vakaet, and H. Thierens, " The influence of small field sizes, penumbra, spot size and measurement depth on perturbation factors for microionization chambers.," Phys. Med. Biol. 54 (9), 2951-2969 (2009). 10.1088/0031-9155/ 54/9/024
    • (2009) Phys. Med. Biol. , vol.54 , Issue.9 , pp. 2951-2969
    • Crop, F.1    Reynaert, N.2    Pittomvils, G.3    Paelinck, L.4    De Wagter, C.5    Vakaet, L.6    Thierens, H.7
  • 26
    • 0017871253 scopus 로고
    • Water/air mass stopping power ratios for megavoltage photon and electron beams
    • 10.1088/0031-9155/23/1/002
    • A. E. Nahum, " Water/air mass stopping power ratios for megavoltage photon and electron beams.," Phys. Med. Biol. 23 (1), 24-38 (1978). 10.1088/0031-9155/23/1/002
    • (1978) Phys. Med. Biol. , vol.23 , Issue.1 , pp. 24-38
    • Nahum, A.E.1
  • 27
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • DOI 10.1118/1.598917
    • I. Kawrakow, " Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version.," Med. Phys. 27 (3), 485-498 (2000). 10.1118/1.598917 (Pubitemid 30171797)
    • (2000) Medical Physics , vol.27 , Issue.3 , pp. 485-498
    • Kawrakow, I.1
  • 28
    • 41449107480 scopus 로고    scopus 로고
    • Efficiency improvements for ion chamber calculations in high energy photon beams
    • 10.1118/1.2874554
    • J. Wulff, K. Zink, and I. Kawrakow, " Efficiency improvements for ion chamber calculations in high energy photon beams.," Med. Phys. 35 (4), 1328-1336 (2008). 10.1118/1.2874554
    • (2008) Med. Phys. , vol.35 , Issue.4 , pp. 1328-1336
    • Wulff, J.1    Zink, K.2    Kawrakow, I.3
  • 30
    • 0029035150 scopus 로고
    • BEAM: A Monte Carlo code to simulate radiotherapy treatment units
    • 10.1118/1.597552
    • D. W. O. Rogers, B. A. Faddegon, G. X. Ding, C.-M. Ma, J. We, and T. R. Mackie, " BEAM: A Monte Carlo code to simulate radiotherapy treatment units.," Med. Phys. 22, 503-524 (1995). 10.1118/1.597552
    • (1995) Med. Phys. , vol.22 , pp. 503-524
    • Rogers, D.W.O.1    Faddegon, B.A.2    Ding, G.X.3    Ma, C.-M.4    We, J.5    MacKie, T.R.6
  • 32
    • 0000792876 scopus 로고
    • Note on the Bragg-Gray cavity principle for measuring energy dissipation
    • 10.2307/3570368
    • U. Fano, " Note on the Bragg-Gray cavity principle for measuring energy dissipation.," Radiat. Res. 1, 237-240 (1954). 10.2307/3570368
    • (1954) Radiat. Res. , vol.1 , pp. 237-240
    • Fano, U.1
  • 33
    • 44649089043 scopus 로고    scopus 로고
    • Modelling ionization chamber response to nonstandard beam configurations
    • 10.1088/1742-6596/102/1/012023
    • L. Tantot and J. Seuntjens, " Modelling ionization chamber response to nonstandard beam configurations.," J. Phys.: Conf. Ser. 102, 1-7 (2008). 10.1088/1742-6596/102/1/012023
    • (2008) J. Phys.: Conf. Ser. , vol.102 , pp. 1-7
    • Tantot, L.1    Seuntjens, J.2
  • 34
    • 0037323117 scopus 로고    scopus 로고
    • Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and 3 mm in diameter)
    • DOI 10.1118/1.1536290
    • K. A. Paskalev, J. P. Seuntjens, H. J. Patrocinio, and E. B. Podgorsak, " Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and 3 mm in diameter).," Med. Phys. 30, 111-118 (2003). 10.1118/1.1536290 (Pubitemid 36222845)
    • (2003) Medical Physics , vol.30 , Issue.2 , pp. 111-118
    • Paskalev, K.A.1    Seuntjens, J.P.2    Patrocinio, H.J.3    Podgorsak, E.B.4
  • 35
    • 16444362815 scopus 로고    scopus 로고
    • Microionization chamber for reference dosimetry in IMRT verification: Clinical implications on OAR dosimetric errors
    • DOI 10.1088/0031-9155/50/5/018
    • F. Sánchez-Doblado, R. Capote, A. Leal, J. V. Roselló, J. I. Lagares, R. Arráns, and G. H. Hartmann, " Microionization chamber for reference dosimetry in IMRT verification: Clinical implications on OAR dosimetric errors.," Phys. Med. Biol. 50 (5), 959-970 (2005). 10.1088/0031-9155/50/5/018 (Pubitemid 40477316)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.5 , pp. 959-970
    • Sanchez-Doblado, F.1    Capote, R.2    Leal, A.3    Rosello, J.V.4    Lagares, J.I.5    Arrans, R.6    Hartmann, G.H.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.