메뉴 건너뛰기




Volumn 41, Issue 1, 1996, Pages 93-110

A comparison of dosimetry techniques in stereotactic radiosurgery

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; DOSIMETRY; PRIORITY JOURNAL; RADIOSURGERY; STEREOTAXIC SURGERY;

EID: 0030026160     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/41/1/008     Document Type: Article
Times cited : (191)

References (34)
  • 1
    • 0026750950 scopus 로고
    • A pencil beam model for photon dose calculation
    • Ahnesjo A, Saxner M and Trepp A 1992 A pencil beam model for photon dose calculation Med. Phys. 19 263-73
    • (1992) Med. Phys. , vol.19 , pp. 263-273
    • Ahnesjo, A.1    Saxner, M.2    Trepp, A.3
  • 2
    • 0022529652 scopus 로고
    • Stopping power data for high-energy photon beams
    • Andreo P and Brahme A 1986 Stopping power data for high-energy photon beams Phys. Med. Biol. 31 839-58
    • (1986) Phys. Med. Biol. , vol.31 , pp. 839-858
    • Andreo, P.1    Brahme, A.2
  • 3
    • 0022364564 scopus 로고
    • Dose measurements and calculations of small radiation fields for 9-MV x rays
    • Arcovito G, Piermattei A, D'Abramo G and Bassi F A 1985 Dose measurements and calculations of small radiation fields for 9-MV x rays Med. Phys. 12 779-84
    • (1985) Med. Phys. , vol.12 , pp. 779-784
    • Arcovito, G.1    Piermattei, A.2    D'Abramo, G.3    Bassi, F.A.4
  • 4
    • 0028133287 scopus 로고
    • Absorbed dose perturbation caused by diodes for small field photon dosimetry
    • Beddar A S, Mason D J and O'Brien P F 1994 Absorbed dose perturbation caused by diodes for small field photon dosimetry Med. Phys. 21 1075-9
    • (1994) Med. Phys. , vol.21 , pp. 1075-1079
    • Beddar, A.S.1    Mason, D.J.2    O'Brien, P.F.3
  • 6
    • 0025998559 scopus 로고
    • Fractionated regimens for stereotactic radiotherapy of recurrent tumours in the brain
    • Brenner D J, Martel M K and Hall E J 1991 Fractionated regimens for stereotactic radiotherapy of recurrent tumours in the brain Int. J. Radiat. Oncol. Biol. Phys. 21 819-24
    • (1991) Int. J. Radiat. Oncol. Biol. Phys. , vol.21 , pp. 819-824
    • Brenner, D.J.1    Martel, M.K.2    Hall, E.J.3
  • 7
    • 0023631671 scopus 로고
    • Electron dose distributions in experimental phantoms: A comparison with 2D pencil beam calculations
    • Cygler J, Battista J J, Scrimger J W, Mah E and Antolak J 1987 Electron dose distributions in experimental phantoms: a comparison with 2D pencil beam calculations Phys. Med. Biol. 32 1073-86
    • (1987) Phys. Med. Biol. , vol.32 , pp. 1073-1086
    • Cygler, J.1    Battista, J.J.2    Scrimger, J.W.3    Mah, E.4    Antolak, J.5
  • 8
    • 0021227635 scopus 로고
    • Analysis of physical parameters associated with the measurement of high energy x-ray penumbera
    • Dawson D J, Harper J M and Akinradewo A C 1984 Analysis of physical parameters associated with the measurement of high energy x-ray penumbera Med Phys. 11 491-7
    • (1984) Med Phys. , vol.11 , pp. 491-497
    • Dawson, D.J.1    Harper, J.M.2    Akinradewo, A.C.3
  • 9
    • 0025990959 scopus 로고
    • Fractionated radiotherapy of small inoperable lesions of the brain using a non-invasive stereotactic frame
    • Delannes M, Daly N J, Bonnet J, Sabatier J and Tremoulet M 1991 Fractionated radiotherapy of small inoperable lesions of the brain using a non-invasive stereotactic frame Int. J. Radiat. Oncol. Biol. Phys. 21 749-55
    • (1991) Int. J. Radiat. Oncol. Biol. Phys. , vol.21 , pp. 749-755
    • Delannes, M.1    Daly, N.J.2    Bonnet, J.3    Sabatier, J.4    Tremoulet, M.5
  • 10
    • 0003275902 scopus 로고
    • Solid state electrical conductivity dosimeters
    • ed F H Attix and W C Roesch (New York: Academic)
    • Fowler J F 1966 Solid state electrical conductivity dosimeters Radiation Dosimetry ed F H Attix and W C Roesch (New York: Academic)
    • (1966) Radiation Dosimetry
    • Fowler, J.F.1
  • 12
    • 0028341289 scopus 로고
    • Measurements of phantom scatter factors for small field sizes in high energy x rays
    • Haider T K and El-Khatib E E 1994 Measurements of phantom scatter factors for small field sizes in high energy x rays Med. Phys. 21 663-6
    • (1994) Med. Phys. , vol.21 , pp. 663-666
    • Haider, T.K.1    El-Khatib, E.E.2
  • 13
    • 0027477449 scopus 로고
    • The radiobiology of radiosurgery: Rationale for different treatment regimes for AVMs and malignancies
    • Hall E J and Brenner D J 1993 The radiobiology of radiosurgery: rationale for different treatment regimes for AVMs and malignancies Int. J. Radiat. Oncol. Biol. Phys. 25 381-5
    • (1993) Int. J. Radiat. Oncol. Biol. Phys. , vol.25 , pp. 381-385
    • Hall, E.J.1    Brenner, D.J.2
  • 15
    • 0027561643 scopus 로고
    • Data acquisition for linac based stereotactic radiosurgery
    • Haworth A and Perry A M 1993 Data acquisition for linac based stereotactic radiosurgery Aust. Phys. Eng. Sci. Med. 13 49-56
    • (1993) Aust. Phys. Eng. Sci. Med. , vol.13 , pp. 49-56
    • Haworth, A.1    Perry, A.M.2
  • 17
    • 0028049726 scopus 로고
    • Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam
    • Hoban P W, Heydarian M, Beckham W A and Beddoe A H 1994 Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam Phys. Med Biol 39 1219-29
    • (1994) Phys. Med Biol , vol.39 , pp. 1219-1229
    • Hoban, P.W.1    Heydarian, M.2    Beckham, W.A.3    Beddoe, A.H.4
  • 18
    • 0014835880 scopus 로고
    • The extention of the concept of tissue-air ratios (TAR) to high energy x-ray beams
    • Holt G, Laughlin J and Moroney J 1970 The extention of the concept of tissue-air ratios (TAR) to high energy x-ray beams Radiology 96 437-46
    • (1970) Radiology , vol.96 , pp. 437-446
    • Holt, G.1    Laughlin, J.2    Moroney, J.3
  • 19
    • 0020213666 scopus 로고
    • Photon mass attenuation and energy- absorption coefficients from 1 KeV to 20 MeV
    • Hubbell J H 1982 Photon mass attenuation and energy- absorption coefficients from 1 KeV to 20 MeV Int. J. Appl. Radiat. Isot. 33 1269-90
    • (1982) Int. J. Appl. Radiat. Isot. , vol.33 , pp. 1269-1290
    • Hubbell, J.H.1
  • 20
    • 0003484991 scopus 로고
    • Absorbed dose determination in photon and electron beams. An international code of practice
    • Vienna: IAEA
    • IAEA 1987 Absorbed dose determination in photon and electron beams. An international code of practice IAEA Technical Report 277 (Vienna: IAEA)
    • (1987) IAEA Technical Report 277
  • 21
    • 0018858258 scopus 로고
    • Revision of tissue maximum ratios and scatter maximum ratio concepts for cobalt 60 and higher energy x-ray beams
    • Khan F, Swechand W, Lee J and Williamson J 1980 Revision of tissue maximum ratios and scatter maximum ratio concepts for cobalt 60 and higher energy x-ray beams Med. Phys. 7 230-7
    • (1980) Med. Phys. , vol.7 , pp. 230-237
    • Khan, F.1    Swechand, W.2    Lee, J.3    Williamson, J.4
  • 23
    • 0026729304 scopus 로고
    • Measurement of the source size of a 6 and 18 MV radiotherapy linac
    • Loewenthal E, Loewinger E, Bar-Avraham E and Barnea G 1992 Measurement of the source size of a 6 and 18 MV radiotherapy linac Med. Phys. 19 687-90
    • (1992) Med. Phys. , vol.19 , pp. 687-690
    • Loewenthal, E.1    Loewinger, E.2    Bar-Avraham, E.3    Barnea, G.4
  • 24
    • 0028218940 scopus 로고
    • The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics
    • McLaughlin W L, Soares C G, Sayeg J A, McCullough E C, Kline R W, Wu A and Maitz A H 1994 The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics Med. Phys. 21 379-88
    • (1994) Med. Phys. , vol.21 , pp. 379-388
    • McLaughlin, W.L.1    Soares, C.G.2    Sayeg, J.A.3    McCullough, E.C.4    Kline, R.W.5    Wu, A.6    Maitz, A.H.7
  • 25
    • 0020213646 scopus 로고
    • Calculation of the energy dependence of dosimeter response to ionizing photons
    • Miller A and McLaughlin W L 1982 Calculation of the energy dependence of dosimeter response to ionizing photons Int. J. Appl. Radiat Isot. 33 1299-310
    • (1982) Int. J. Appl. Radiat Isot. , vol.33 , pp. 1299-1310
    • Miller, A.1    McLaughlin, W.L.2
  • 26
    • 0021849353 scopus 로고
    • Energy and angular distributions of photons from medical linear accelerators
    • Mohan R, Chui C and Lidofsky L 1985 Energy and angular distributions of photons from medical linear accelerators Med. Phys. 12 592-7
    • (1985) Med. Phys. , vol.12 , pp. 592-597
    • Mohan, R.1    Chui, C.2    Lidofsky, L.3
  • 27
    • 0023623538 scopus 로고
    • Dose distributions in dynamic stereotactic radiosurgery
    • Pike B, Podgorsak E B, Peters T M and Pla C 1987 Dose distributions in dynamic stereotactic radiosurgery Med. Phys. 14 780-9
    • (1987) Med. Phys. , vol.14 , pp. 780-789
    • Pike, B.1    Podgorsak, E.B.2    Peters, T.M.3    Pla, C.4
  • 29
    • 0028349847 scopus 로고
    • The use of radiochromic film in treatment verification of stereotactic radiosurgery
    • Ramani R, Lightstone A W, Mason D L D and O'Brien P F 1994 The use of radiochromic film in treatment verification of stereotactic radiosurgery Med. Phys. 21 389-92
    • (1994) Med. Phys. , vol.21 , pp. 389-392
    • Ramani, R.1    Lightstone, A.W.2    Mason, D.L.D.3    O'Brien, P.F.4
  • 30
    • 0023632209 scopus 로고
    • Measurements of dose distributions in small beams of 6 MV x-rays
    • Rice R K, Hansen J L, Svensson G K and Siddon R L 1987 Measurements of dose distributions in small beams of 6 MV x-rays Phys. Med. Biol. 32 1087-99
    • (1987) Phys. Med. Biol. , vol.32 , pp. 1087-1099
    • Rice, R.K.1    Hansen, J.L.2    Svensson, G.K.3    Siddon, R.L.4
  • 31
    • 0029004417 scopus 로고
    • Evaluation of the dosimetric characteristics of a diamond detector for photon beam measurements
    • Rustgi S N 1995 Evaluation of the dosimetric characteristics of a diamond detector for photon beam measurements Med. Phys. 22 567-70
    • (1995) Med. Phys. , vol.22 , pp. 567-570
    • Rustgi, S.N.1
  • 33
    • 0027210922 scopus 로고
    • Comments on dose measurements for a narrow beam in radiosurgery
    • Wu A, Zwicker R D, Kalend A M and Zheng Z 1993 Comments on dose measurements for a narrow beam in radiosurgery Med. Phys. 20 777-9
    • (1993) Med. Phys. , vol.20 , pp. 777-779
    • Wu, A.1    Zwicker, R.D.2    Kalend, A.M.3    Zheng, Z.4
  • 34
    • 0029052123 scopus 로고
    • Physical penumbra change of beam profile due to film digitization
    • Yin F F 1995 Physical penumbra change of beam profile due to film digitization Med. Phys. 22 803-5
    • (1995) Med. Phys. , vol.22 , pp. 803-805
    • Yin, F.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.