메뉴 건너뛰기




Volumn 73, Issue , 2012, Pages 55-61

A micro-fluidic sub-microliter sample introduction system for direct analysis of Chinese rice wine by inductively coupled plasma mass spectrometry using external aqueous calibration

Author keywords

Chinese rice wine; Direct analysis; Inductively coupled plasma mass spectrometry; Microfluidic; Sub microliter sample

Indexed keywords

CARBON DEPOSITION; CERTIFIED REFERENCE MATERIALS; CHINESE RICE WINE; DETECTION LIMITS; DIRECT ANALYSIS; DIRECT DETERMINATION; FLOW-INJECTION ANALYSIS; MATRIX EFFECTS; MICRO-FLOW; MICROFLUIDIC CHIP; MICROWAVE ASSISTED DIGESTION; MULTI-ELEMENT STANDARDS; MULTI-FUNCTIONAL; PEAK HEIGHT; PERISTALTIC PUMP; QUALITY CONTROL TESTS; RED WINE; SAMPLE INTRODUCTION; SAMPLING SYSTEMS; SAMPLING VOLUME; SUB-MICROLITER SAMPLE; SYRINGE PUMPS; THREE SOLUTIONS;

EID: 84864657460     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sab.2012.07.010     Document Type: Article
Times cited : (20)

References (29)
  • 2
    • 33644867277 scopus 로고    scopus 로고
    • Antioxidant activities of five Chinese rice wines and the involvement of phenolic compounds
    • DOI 10.1016/j.foodres.2005.12.001, PII S0963996905002577
    • F. Que, L.C. Mao, and X. Pan Antioxidant activities of five Chinese rice wines and the involvement of phenolic compounds Food Res. Int. 39 2006 581 587 (Pubitemid 43374956)
    • (2006) Food Research International , vol.39 , Issue.5 , pp. 581-587
    • Que, F.1    Mao, L.2    Pan, X.3
  • 3
    • 34248523520 scopus 로고    scopus 로고
    • Chinese yellow wine inhibits production of homocysteine-induced extracellular matrix metalloproteinase-2 in cultured rat vascular smooth muscle cells
    • DOI 10.1016/j.clnu.2007.01.007, PII S0261561407000325
    • H.Y. Guo, P. Wang, B.Q. You, Y.B. Xing, and J.D. Lee Chinese yellow wine inhibits production of homocysteine-induced extracellular matrix metalloproteinase-2 in cultured rat vascular smooth muscle cells Clin. Nutr. 26 2007 348 354 (Pubitemid 46760479)
    • (2007) Clinical Nutrition , vol.26 , Issue.3 , pp. 348-354
    • Guo, H.1    Wang, P.2    You, B.3    Xing, Y.4    Lee, J.-D.5
  • 4
    • 77952133678 scopus 로고    scopus 로고
    • Chinese yellow wine and red wine inhibit matrix metalloproteinase-2 and improve atherosclerotic plaque in LDL receptor knockout mice
    • H.Y. Guo, L.B. Liu, Y.F. Shi, A.J. Sun, F.K. Xu, J.F. Chi, and D.L. Huang Chinese yellow wine and red wine inhibit matrix metalloproteinase-2 and improve atherosclerotic plaque in LDL receptor knockout mice Cardiovasc. Ther. 28 2010 161 168
    • (2010) Cardiovasc. Ther. , vol.28 , pp. 161-168
    • Guo, H.Y.1    Liu, L.B.2    Shi, Y.F.3    Sun, A.J.4    Xu, F.K.5    Chi, J.F.6    Huang, D.L.7
  • 5
    • 35148879556 scopus 로고    scopus 로고
    • What do metals tell us about wine?
    • DOI 10.1016/j.trac.2007.07.005, PII S0165993607001513
    • P. Pohl What do metals tell us about wine? TrAC-Trend. Anal. Chem. 26 2007 941 949 (Pubitemid 47534239)
    • (2007) TrAC - Trends in Analytical Chemistry , vol.26 , Issue.9 , pp. 941-949
    • Pohl, P.1
  • 6
    • 0037201960 scopus 로고    scopus 로고
    • Antioxidant nutrients and lead toxicity
    • P.C. Hsu, and Y.L.L. Guo Antioxidant nutrients and lead toxicity Toxicology 180 2002 33 44
    • (2002) Toxicology , vol.180 , pp. 33-44
    • Hsu, P.C.1    Guo, Y.L.L.2
  • 7
    • 78349310471 scopus 로고    scopus 로고
    • New perspectives in cadmium toxicity: An introduction
    • J.M. Moulis, and F. Thévenod New perspectives in cadmium toxicity: an introduction Biometals 23 2010 763 768
    • (2010) Biometals , vol.23 , pp. 763-768
    • Moulis, J.M.1    Thévenod, F.2
  • 8
    • 77649185955 scopus 로고    scopus 로고
    • Characterization of wines using compositional profiles and chemometrics
    • J. Saurina Characterization of wines using compositional profiles and chemometrics TrAC-Trend. Anal. Chem. 29 2010 234 245
    • (2010) TrAC-Trend. Anal. Chem. , vol.29 , pp. 234-245
    • Saurina, J.1
  • 9
    • 34250649282 scopus 로고    scopus 로고
    • Discrimination between Chinese rice wines of different geographical origins by NIRS and AAS
    • DOI 10.1007/s00217-006-0416-8
    • H.Y. Yu, Y. Zhou, X.P. Fu, L.J. Xie, and Y.B. Ying Discrimination between Chinese rice wines of different geographical origins by NIRS and AAS Eur. Food Res. Technol. 225 2007 313 320 (Pubitemid 46945647)
    • (2007) European Food Research and Technology , vol.225 , Issue.3-4 , pp. 313-320
    • Yu, H.1    Fu, X.2    Xie, L.3    Ying, Y.4    Zhou, Y.5
  • 10
    • 77953594666 scopus 로고    scopus 로고
    • Inductively coupled plasma mass spectrometry
    • D. Beauchemin Inductively coupled plasma mass spectrometry Anal. Chem. 82 2010 4786 4810
    • (2010) Anal. Chem. , vol.82 , pp. 4786-4810
    • Beauchemin, D.1
  • 11
    • 47849105967 scopus 로고    scopus 로고
    • Searching the most appropriate sample pretreatment for the elemental analysis of wines by inductively coupled plasma-based techniques
    • DOI 10.1021/jf800286y
    • A. Gonzálvez, S. Armenta, A. Pastor, and M. de la Guardia Searching the most appropriate sample pretreatment for the elemental analysis of wines by inductively coupled plasma-based techniques J. Agric. Food Chem. 56 2008 4943 4954 (Pubitemid 352039088)
    • (2008) Journal of Agricultural and Food Chemistry , vol.56 , Issue.13 , pp. 4943-4954
    • Gonzalvez, A.1    Armenta, S.2    Pastor, A.3    De La Guardia, M.4
  • 12
    • 53649096508 scopus 로고    scopus 로고
    • Application of a microwave-based desolvation system for multi-elemental analysis of wine by inductively coupled plasma based techniques
    • G. Grindlay, J. Mora, S. Maestre, and L. Gras Application of a microwave-based desolvation system for multi-elemental analysis of wine by inductively coupled plasma based techniques Anal. Chim. Acta 629 2008 24 37
    • (2008) Anal. Chim. Acta , vol.629 , pp. 24-37
    • Grindlay, G.1    Mora, J.2    Maestre, S.3    Gras, L.4
  • 13
    • 0036008145 scopus 로고    scopus 로고
    • Precise determination of the strontium isotope ratios in wine by inductively coupled plasma sector field multicollector mass spectrometry (ICP-SF-MC-MS)
    • DOI 10.1039/b109559p
    • M. Barbaste, K. Robinson, S. Guilfoyle, B. Medina, and R. Lobinski Precise determination of the strontium isotope ratios in wine by inductively coupled plasma sector field multicollector mass spectrometry (ICP-SF-MC-MS) J. Anal. At. Spectrom. 17 2002 135 137 (Pubitemid 34154323)
    • (2002) Journal of Analytical Atomic Spectrometry , vol.17 , Issue.2 , pp. 135-137
    • Barbaste, M.1    Robinson, K.2    Guilfoyle, S.3    Medina, B.4    Lobinski, R.5
  • 14
    • 33947514266 scopus 로고    scopus 로고
    • Differentiation of two Canary DO red wines according to their metal content from inductively coupled plasma optical emission spectrometry and graphite furnace atomic absorption spectrometry by using Probabilistic Neural Networks
    • DOI 10.1016/j.talanta.2006.10.029, PII S0039914006007168
    • I.M. Moreno, D. González-Weller, V. Gutierrez, M. Marino, A.M. Cameán, A.G. González, and A. Hardisson Differentiation of two Canary DO red wines according to their metal content from inductively coupled plasma optical emission spectrometry and graphite furnace atomic absorption spectrometry by using Probabilistic Neural Networks Talanta 72 2007 263 268 (Pubitemid 46463925)
    • (2007) Talanta , vol.72 , Issue.1 , pp. 263-268
    • Moreno, I.M.1    Gonzalez-Weller, D.2    Gutierrez, V.3    Marino, M.4    Camean, A.M.5    Gonzalez, A.G.6    Hardisson, A.7
  • 16
    • 52949149338 scopus 로고    scopus 로고
    • Study on different pre-treatment procedures for metal determination in Orujo spirit samples by ICP-AES
    • J. Barciela, M. Vilar, S. García-Martín, R.M. Peña, and C. Herrero Study on different pre-treatment procedures for metal determination in Orujo spirit samples by ICP-AES Anal. Chim. Acta 628 2008 33 40
    • (2008) Anal. Chim. Acta , vol.628 , pp. 33-40
    • Barciela, J.1    Vilar, M.2    García-Martín, S.3    Peña, R.M.4    Herrero, C.5
  • 17
    • 50049124277 scopus 로고    scopus 로고
    • Determination of trace elements in fuel ethanol by ICP-MS using direct sample introduction by a microconcentric nebulizer
    • L. Tormen, E.S. Chaves, T.D. Saint'Pierre, V.L.A. Frescura, and A.J. Curtius Determination of trace elements in fuel ethanol by ICP-MS using direct sample introduction by a microconcentric nebulizer J. Anal. At. Spectrom. 23 2008 1300 1304
    • (2008) J. Anal. At. Spectrom. , vol.23 , pp. 1300-1304
    • Tormen, L.1    Chaves, E.S.2    Saint'Pierre, T.D.3    Frescura, V.L.A.4    Curtius, A.J.5
  • 18
    • 0037010549 scopus 로고    scopus 로고
    • Trace element determination in crude oil and its fractions by inductively coupled plasma mass spectrometry using ultrasonic nebulization of toluene solutions
    • C. Duyck, N. Miekeley, C.L.P. da Silveira, and P. Szatmari Trace element determination in crude oil and its fractions by inductively coupled plasma mass spectrometry using ultrasonic nebulization of toluene solutions Spectrochim. Acta Part B 57 2002 1979 1990
    • (2002) Spectrochim. Acta Part B , vol.57 , pp. 1979-1990
    • Duyck, C.1    Miekeley, N.2    Da Silveira, C.L.P.3    Szatmari, P.4
  • 19
    • 77951853625 scopus 로고    scopus 로고
    • Direct multi-element analysis of crude oils and gas condensates by double-focusing sector field inductively coupled plasma mass spectrometry (ICP MS)
    • P. Pohl, N. Vorapalawut, B. Bouyssiere, H. Carrier, and R. Lobinski Direct multi-element analysis of crude oils and gas condensates by double-focusing sector field inductively coupled plasma mass spectrometry (ICP MS) J. Anal. At. Spectrom. 25 2010 704 709
    • (2010) J. Anal. At. Spectrom. , vol.25 , pp. 704-709
    • Pohl, P.1    Vorapalawut, N.2    Bouyssiere, B.3    Carrier, H.4    Lobinski, R.5
  • 20
    • 33646391712 scopus 로고    scopus 로고
    • Novel multi-depth microfluidic chip for single cell analysis
    • S. Yue, and X.F. Yin Novel multi-depth microfluidic chip for single cell analysis J. Chromatogr. A 1117 2006 228 233
    • (2006) J. Chromatogr. A , vol.1117 , pp. 228-233
    • Yue, S.1    Yin, X.F.2
  • 21
    • 0032814992 scopus 로고    scopus 로고
    • Microfluidic devices connected to fused-silica capillaries with minimal dead volume
    • DOI 10.1021/ac981419z
    • N.H. Bings, C. Wang, C.D. Skinner, C.L. Colyer, P. Thibault, and D.J. Harrison Microfluidic devices connected to fused-silica capillaries with minimal dead volume Anal. Chem. 71 1999 3292 3296 (Pubitemid 29372752)
    • (1999) Analytical Chemistry , vol.71 , Issue.15 , pp. 3292-3296
    • Bings, N.H.1    Wang, C.2    Skinner, C.D.3    Colyer, C.L.4    Thibault, P.5    Harrison, D.J.6
  • 22
    • 79958117772 scopus 로고    scopus 로고
    • A simple and demountable capillary microflow nebulizer with a tapered tip for inductively coupled plasma mass spectrometry
    • H.Y. Cheng, X.F. Yin, Z.G. Xu, X.Z. Wang, and H. Shen A simple and demountable capillary microflow nebulizer with a tapered tip for inductively coupled plasma mass spectrometry Talanta 85 2011 794 799
    • (2011) Talanta , vol.85 , pp. 794-799
    • Cheng, H.Y.1    Yin, X.F.2    Xu, Z.G.3    Wang, X.Z.4    Shen, H.5
  • 23
    • 84863011444 scopus 로고    scopus 로고
    • A microfluidic system for introduction of nanolitre sample in inductively coupled plasma mass spectrometry using electrokinetic flow combined with hydrodynamic flow
    • H.Y. Cheng, Z.G. Xu, J.H. Liu, X.Z. Wang, and X.F. Yin A microfluidic system for introduction of nanolitre sample in inductively coupled plasma mass spectrometry using electrokinetic flow combined with hydrodynamic flow J. Anal. At. Spectrom. 27 2012 346 353
    • (2012) J. Anal. At. Spectrom. , vol.27 , pp. 346-353
    • Cheng, H.Y.1    Xu, Z.G.2    Liu, J.H.3    Wang, X.Z.4    Yin, X.F.5
  • 25
    • 0001374212 scopus 로고
    • Reduction of polyatomic ion interferences in inductively coupled plasma mass spectrometry by cryogenic desolvation
    • L.C. Alves, D.R. Wiederin, and R.S. Houk Reduction of polyatomic ion interferences in inductively coupled plasma mass spectrometry by cryogenic desolvation Anal. Chem. 64 1992 1164 1169
    • (1992) Anal. Chem. , vol.64 , pp. 1164-1169
    • Alves, L.C.1    Wiederin, D.R.2    Houk, R.S.3
  • 27
    • 84864717711 scopus 로고    scopus 로고
    • Techniques for the analysis of organic chemicals by inductively coupled plasma mass spectrometry (ICP-MS)
    • E. McCurdy, and D. Potter Techniques for the analysis of organic chemicals by inductively coupled plasma mass spectrometry (ICP-MS) Agilent Technologies 2002 (http://www.chem.agilent.com/Library/applications/5988-6190EN. pdf)
    • (2002) Agilent Technologies
    • McCurdy, E.1    Potter, D.2
  • 29
    • 67649684026 scopus 로고    scopus 로고
    • Heated-spray chamber-based low sample consumption system for inductively coupled plasma spectrometry
    • E. Paredes, M. Grotti, J.M. Mermet, and J.L. Todolí Heated-spray chamber-based low sample consumption system for inductively coupled plasma spectrometry J. Anal. At. Spectrom. 24 2009 903 910
    • (2009) J. Anal. At. Spectrom. , vol.24 , pp. 903-910
    • Paredes, E.1    Grotti, M.2    Mermet, J.M.3    Todolí, J.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.