1
-
-
0025756532
-
Semiempirical model for generating tungsten target x-ray spectra
-
10.1118/1.596709
-
D. M. Tucker, G. T. Barnes, and D. P. Chakraborty, " Semiempirical model for generating tungsten target x-ray spectra.," Med. Phys. 18 (2), 211-218 (1991). 10.1118/1.596709
-
(1991)
Med. Phys.
, vol.18
, Issue.2
, pp. 211-218
-
-
Tucker, D.M.1
Barnes, G.T.2
Chakraborty, D.P.3
-
2
-
-
33645196336
-
-
(Springer-Verlag, Berlin).
-
H. Aichinger, J. Dierker, S. Joite-BarfuΒ, and M. Säbel, Radiation Exposure and Image Quality in X-Ray Diagnostic Radiology (Springer-Verlag, Berlin, 2004).
-
(2004)
Radiation Exposure and Image Quality in X-Ray Diagnostic Radiology
-
-
Aichinger, H.1
Dierker, J.2
Joite-Barfu, S.3
Säbel, M.4
-
3
-
-
44649117043
-
Signal transport in computed tomography detectors
-
10.1016/j.nima.2008.03.018
-
B. J. Heismann, K. Pham-Gia, W. Metzger, D. Niederloehner, and S. Wirth, " Signal transport in computed tomography detectors.," Nucl. Instrum. Methods Phys. Res. A 591 (1), 28-33 (2008). 10.1016/j.nima.2008.03.018
-
(2008)
Nucl. Instrum. Methods Phys. Res. A
, vol.591
, Issue.1
, pp. 28-33
-
-
Heismann, B.J.1
Pham-Gia, K.2
Metzger, W.3
Niederloehner, D.4
Wirth, S.5
-
4
-
-
0017810277
-
A method for correcting bone induced artifacts in CT scanners
-
10.1097/00004728-197801000-00017
-
P. M. Joseph and R. D. Spital, " A method for correcting bone induced artifacts in CT scanners.," J. Comput. Assist. Tomogr. 2, 100-108 (1978). 10.1097/00004728-197801000-00017
-
(1978)
J. Comput. Assist. Tomogr.
, vol.2
, pp. 100-108
-
-
Joseph, P.M.1
Spital, R.D.2
-
5
-
-
0018404829
-
Post-reconstruction method for beam hardening in computerised tomography
-
10.1088/0031-9155/24/2/009
-
O. Nalcioglu and R. Lou, " Post-reconstruction method for beam hardening in computerised tomography.," Phys. Med. Biol. 24 (2), 330-340 (1979). 10.1088/0031-9155/24/2/009
-
(1979)
Phys. Med. Biol.
, vol.24
, Issue.2
, pp. 330-340
-
-
Nalcioglu, O.1
Lou, R.2
-
6
-
-
0030867231
-
A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine
-
DOI 10.1118/1.597970
-
P. M. Joseph and C. Ruth, " A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine.," Med. Phys. 24 (10), 1629-1634 (1997). 10.1118/1.597970 (Pubitemid 27449551)
-
(1997)
Medical Physics
, vol.24
, Issue.10
, pp. 1629-1634
-
-
Joseph, P.M.1
Ruth, C.2
-
7
-
-
0033624949
-
Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction
-
DOI 10.1109/42.832955
-
C. H. Yan, R. T. Whalen, G. S. Beaupre, S. Y. Yen, and S. Napel, " Reconstruction algorithm for polychromatic CT imaging: Application to beam hardening correction.," IEEE Trans. Med. Imaging 19 (1), 1-11 (2000). 10.1109/42.832955 (Pubitemid 30594950)
-
(2000)
IEEE Transactions on Medical Imaging
, vol.19
, Issue.1
, pp. 1-11
-
-
Yan, C.H.1
Whalen, R.T.2
Beaupre, G.S.3
Yen, S.Y.4
Napel, S.5
-
8
-
-
0018399326
-
Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with Ge(Li) detector
-
10.1088/0031-9155/24/3/002
-
R. Birch and M. Marshall, " Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with Ge(Li) detector.," Phys. Med. Biol. 24 (3), 505-517 (1979). 10.1088/0031-9155/24/3/002
-
(1979)
Phys. Med. Biol.
, vol.24
, Issue.3
, pp. 505-517
-
-
Birch, R.1
Marshall, M.2
-
9
-
-
0003966102
-
-
NIST Standard Reference Database 8 (XGAM).
-
M. J. Berger, J. H. Hubbell, S. M. Seltzer, J. Chang, J. S. Coursey, R. Sukumar, and D. S. Zucker, " XCOM: Photon cross sections database.," NIST Standard Reference Database 8 (XGAM), 1998.
-
(1998)
XCOM: Photon Cross Sections Database
-
-
Berger, M.J.1
Hubbell, J.H.2
Seltzer, S.M.3
Chang, J.4
Coursey, J.S.5
Sukumar, R.6
Zucker, D.S.7
-
12
-
-
38649132610
-
Impact of photon transport properties on the detection efficiency of scintillator arrays
-
(IEEE, San Diego), paper No. M11-212
-
S. Wirth, W. Metzger, K. Pham-Gia, and B. J. Heismann, " Impact of photon transport properties on the detection efficiency of scintillator arrays.," IEEE Nuclear Science Symposium Conference (IEEE, San Diego, 2003), paper No. M11-212, pp. 2602-2603.
-
(2003)
IEEE Nuclear Science Symposium Conference
, pp. 2602-2603
-
-
Wirth, S.1
Metzger, W.2
Pham-Gia, K.3
Heismann, B.J.4
-
13
-
-
0345390820
-
Modeling of polychromatic attenuation using computed tomography reconstructed images
-
DOI 10.1118/1.598563
-
C. H. Yan, R. T. Whalen, G. S. Beaupr, S. Y. Yen, and S. Napel, " Modeling of polychromatic attenuation using computed tomography reconstructed images.," Med. Phys. 26 (4), 631-642 (1999). 10.1118/1.598563 (Pubitemid 29186282)
-
(1999)
Medical Physics
, vol.26
, Issue.4
, pp. 631-642
-
-
Yan, C.H.1
Whalen, R.T.2
Beaupre, G.S.3
Yen, S.Y.4
Napel, S.5
-
14
-
-
0030919839
-
Estimation of a photon energy spectrum for a computed tomography scanner
-
DOI 10.1118/1.598159
-
C. Ruth and P. M. Joseph, " Estimation of a photon energy spectrum for a computed tomography scanner.," Med. Phys. 24 (5), 695-702 (1997). 10.1118/1.598159 (Pubitemid 27215205)
-
(1997)
Medical Physics
, vol.24
, Issue.5
, pp. 695-702
-
-
Ruth, C.1
Joseph, P.M.2
-
15
-
-
21644449154
-
A robust method of x-ray source spectrum estimation from transmission measurements: Demonstrated on computer simulated, scatter-free transmission data
-
DOI 10.1063/1.1928312, 124701
-
E. Y. Sidky, L. Yu, X. Pan, Y. Zou, and M. Vannier, " A robust method of x-ray source spectrum estimation from transmission measurements: Demonstrated on computer simulated, scatter free transmission data.," J. Appl. Phys. 97 (12), 124701-124711 (2005). 10.1063/1.1928312 (Pubitemid 40925370)
-
(2005)
Journal of Applied Physics
, vol.97
, Issue.12
, pp. 1-11
-
-
Sidky, E.Y.1
Yu, L.2
Pan, X.3
Zou, Y.4
Vannier, M.5
-
16
-
-
0001169360
-
Über die Bestimmung von Funktionen durch ihre Integralwerte längs gewisser Mannigfaltigkeiten
-
J. Radon, " Über die Bestimmung von Funktionen durch ihre Integralwerte längs gewisser Mannigfaltigkeiten.," Bericht der Sächsischen Akademie Wissenschaften 69, 262-277 (1917).
-
(1917)
Bericht der Sächsischen Akademie Wissenschaften
, vol.69
, pp. 262-277
-
-
Radon, J.1
-
17
-
-
0017108614
-
Energy-selective reconstructions in x-ray computerized tomography
-
10.1088/0031-9155/21/5/002
-
R. E. Alvarez and A. Macovski, " Energy-selective reconstructions in x-ray computerized tomography.," Phys. Med. Biol. 21 (5), 733-744 (1976). 10.1088/0031-9155/21/5/002
-
(1976)
Phys. Med. Biol.
, vol.21
, Issue.5
, pp. 733-744
-
-
Alvarez, R.E.1
MacOvski, A.2
-
18
-
-
35148816698
-
Image-domain material decomposition using photon-counting CT
-
DOI 10.1117/12.713508, Medical Imaging 2007: Physics of Medical Imaging
-
K. Taguchi, M. Zhang, E. C. Frey, J. Xu, W. P. Segars, and B. M. W. Tsui, " Image-domain material decomposition using photon-counting CT.," Proc. SPIE 6510 (1), 651008-651012 (2007). 10.1117/12.713508 (Pubitemid 47550103)
-
(2007)
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
, vol.6510
, Issue.PART 1
, pp. 651008
-
-
Taguchi, K.1
Zhang, M.2
Frey, E.C.3
Xu, J.4
Segars, W.P.5
Tsui, B.M.W.6
-
19
-
-
0022528370
-
Tissue analysis by dual-energy computed tomography
-
10.1259/0007-1285-59-702-537
-
D. J. Hawkes, D. F. Jackson, and R. P. Parker, " Tissue analysis by dual-energy computed tomography.," Br. J. Radiol. 59, 537-542 (1986). 10.1259/0007-1285-59-702-537
-
(1986)
Br. J. Radiol.
, vol.59
, pp. 537-542
-
-
Hawkes, D.J.1
Jackson, D.F.2
Parker, R.P.3
-
20
-
-
0022528984
-
Evaluation of a prototype dual-energy computed tomographic apparatus. II. Determination of vertebral bone mineral content
-
DOI 10.1118/1.595951
-
J. Vetter, W. Perman, W. A. Kalender, R. Mazess, and J. Holden, " Evaluation of a prototype dual-energy computed tomographic apparatus. II. Determination of vertebral bone mineral content.," Med. Phys. 13 (3), 340-343 (1986). 10.1118/1.595951 (Pubitemid 16062266)
-
(1986)
Medical Physics
, vol.13
, Issue.3
, pp. 340-349
-
-
Vetter, J.R.1
Perman, W.H.2
Kalender, W.A.3
-
21
-
-
0042510909
-
Density and atomic number measurements with spectral x-ray attenuation method
-
10.1063/1.1586963
-
B. J. Heismann, J. Leppert, and K. Stierstorfer, " Density and atomic number measurements with spectral x-ray attenuation method.," J. Appl. Phys. 94 (3), 2074-2079 (2003). 10.1063/1.1586963
-
(2003)
J. Appl. Phys.
, vol.94
, Issue.3
, pp. 2074-2079
-
-
Heismann, B.J.1
Leppert, J.2
Stierstorfer, K.3
|