메뉴 건너뛰기




Volumn 37, Issue 1, 2010, Pages 54-62

Lung perfusion imaging in small animals using 4D micro-CT at heartbeat temporal resolution

Author keywords

Digital subtraction angiography; Functional imaging; Image reconstruction; Lung; Micro CT; Perfusion; Small animal; X ray

Indexed keywords

BIOLOGICAL ORGANS; IMAGE RECONSTRUCTION; IMAGE RESOLUTION; RATS; X RAYS;

EID: 73649083320     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3264619     Document Type: Article
Times cited : (32)

References (32)
  • 1
    • 28444486874 scopus 로고    scopus 로고
    • Arterial spin labeling in small animals: Methods and applications to experimental cerebral ischemia
    • DOI 10.1002/jmri.20453
    • D. L. Thomas, " Arterial spin labeling in small animals: Methods and applications to experimental cerebral ischemia.," J. Magn. Reson Imaging 1053-1807 22, 741-744 (2005). 10.1002/jmri.20453 (Pubitemid 41741241)
    • (2005) Journal of Magnetic Resonance Imaging , vol.22 , Issue.6 , pp. 741-744
    • Thomas, D.L.1
  • 2
    • 3543119624 scopus 로고    scopus 로고
    • Assessment of tumor blood perfusion by high-resolution dynamic contrast-enhance MRI: A preclinical study of human melanoma xenografts
    • DOI 10.1002/mrm.20149
    • I. C. Benjaminsen, B. A. Graff, K. G. Brurberg, and E. K. Rofstad, " Assessment of tumor blood perfusion by high-resolution dynamic contrast-enhanced MRI: A preclinical study of human melanoma xenografts.," Magn. Reson. Med. 0740-3194 52, 269-276 (2004). 10.1002/mrm.20149 (Pubitemid 39025270)
    • (2004) Magnetic Resonance in Medicine , vol.52 , Issue.2 , pp. 269-276
    • Benjaminsen, I.C.1    Graff, B.A.2    Brurberg, K.G.3    Rofstad, E.K.4
  • 3
    • 26444526921 scopus 로고    scopus 로고
    • 15O labelled water: The application of a cardiac time-activity curve for the tracer arterial input function
    • DOI 10.1097/00006231-200510000-00009
    • S. H. Yee, P. A. Jerabek, and P. T. Fox, " Non-invasive quantification of cerebral blood flow for rats by microPET imaging of 15O labeled water: The application of a cardiac time-activity curve for the tracer arterial input function.," Nucl. Med. Commun. 0143-3636 26, 903-911 (2005). 10.1097/00006231-200510000-00009 (Pubitemid 41426553)
    • (2005) Nuclear Medicine Communications , vol.26 , Issue.10 , pp. 903-911
    • Yee, S.-H.1    Jerabek, P.A.2    Fox, P.T.3
  • 4
    • 23044453691 scopus 로고    scopus 로고
    • Assessment of left ventricular perfusion, volumes, and motion in mice using pinhole gated SPECT
    • 0161-5505
    • A. Constantinesco, P. Choquet, L. Monassier, V. Israel-Jost, and L. Mertz, " Assessment of left ventricular perfusion, volumes, and motion in mice using pinhole gated SPECT.," J. Nucl. Med. 0161-5505 46, 1005-1011 (2005).
    • (2005) J. Nucl. Med. , vol.46 , pp. 1005-1011
    • Constantinesco, A.1    Choquet, P.2    Monassier, L.3    Israel-Jost, V.4    Mertz, L.5
  • 5
    • 33745366060 scopus 로고    scopus 로고
    • Image quality assessment of a pre-clinical flat-panel volumetric micro-CT scanner
    • DOI 10.1117/12.650970, Medical Imaging 2006: Physics of Medical Imaging
    • L. Y. Du, T. -Y. Lee, and D. W. Holdsworth, " Image quality assessment of a pre-clinical flat-panel volumetric micro-CT scanner.," Proc. SPIE 0277-786X 6142, 614216.1-614216.8 (2006). 10.1117/12.650970 (Pubitemid 43944892)
    • (2006) Progress in Biomedical Optics and Imaging - Proceedings of SPIE , vol.6142 , pp. 614216
    • Du, L.Y.1    Lee, T.-Y.2    Holdsworth, D.W.3
  • 8
    • 34548661688 scopus 로고    scopus 로고
    • Dynamic perfusion CT: Optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients
    • DOI 10.1016/j.ejrad.2007.02.025, PII S0720048X07001027
    • A. Kamena, F. Streitparth, C. Grieser, L. Lehmkuhl, B. Jamil, K. Wojtal, J. Ricke, and M. Pech, " Dynamic perfusion CT: Optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients.," Eur. J. Radiol. 0720-048X 64, 111-118 (2007). 10.1016/j.ejrad.2007.02.025 (Pubitemid 47418571)
    • (2007) European Journal of Radiology , vol.64 , Issue.1 , pp. 111-118
    • Kamena, A.1    Streitparth, F.2    Grieser, C.3    Lehmkuhl, L.4    Jamil, B.5    Wojtal, K.6    Ricke, J.7    Pech, M.8
  • 9
    • 84884460912 scopus 로고    scopus 로고
    • (American College of Laboratory Animal Medicine, December 14, 2006), edited by J. G. Fox, S. W. Barthold, M. T. Davisson, C. E. Newcomer, F. W. Quimby, and A. Smith (Academic Press, Elsevier Science and Technology Books)
    • The Mouse in Biomedical Research, Volume 2, Second Edition: Diseases (American College of Laboratory Animal Medicine, December 14, 2006), edited by, J. G. Fox, S. W. Barthold, M. T. Davisson, C. E. Newcomer, F. W. Quimby, and, A. Smith, (Academic Press, Elsevier Science and Technology Books, 2007).
    • (2007) The Mouse in Biomedical Research, Volume 2, Second Edition: Diseases
  • 10
    • 0036084815 scopus 로고    scopus 로고
    • Autonomic control of blood pressure in mice: Basic physiology and effects of genetic modification
    • 0363-6119
    • B. J. Janssen and J. F. Smits, " Autonomic control of blood pressure in mice: Basic physiology and effects of genetic modification.," Am. J. Physiol. Regulatory Integrative Comp. Physiol. 0363-6119 282, R1545-R1564 (2002).
    • (2002) Am. J. Physiol. Regulatory Integrative Comp. Physiol. , vol.282
    • Janssen, B.J.1    Smits, J.F.2
  • 11
    • 34250159800 scopus 로고    scopus 로고
    • A micro-computed tomography-based method for the measurement of pulmonary compliance in healthy and bleomycin-exposed mice
    • DOI 10.1080/01902140701364458, PII 779292672
    • S. Shofer, C. Badea, S. Auerbach, D. A. Schwartz, and G. A. Johnson, " A micro-computed tomography-based method for the measurement of pulmonary compliance in healthy and bleomycin-exposed mice.," Exp. Lung Res. 0190-2148 33, 169-183 (2007). 10.1080/01902140701364458 (Pubitemid 46897655)
    • (2007) Experimental Lung Research , vol.33 , Issue.3-4 , pp. 169-183
    • Shofer, S.1    Badea, C.2    Auerbach, S.3    Schwartz, D.A.4    Johnson, G.A.5
  • 12
    • 27944437472 scopus 로고    scopus 로고
    • In vivo assessment of emphysema in mice by high resolution X-ray microtomography
    • DOI 10.1111/j.1365-2818.2005.01510.x
    • A. A. Postnov, K. Meurrens, H. Weiler, D. Van Dyck, H. Xu, P. Terpstra, and N. M. De Clerck, " In vivo assessment of emphysema in mice by high resolution x-ray microtomography.," J. Microsc. 0022-2720 220, 70-75 (2005). 10.1111/j.1365-2818.2005.01510.x (Pubitemid 41676703)
    • (2005) Journal of Microscopy , vol.220 , Issue.1 , pp. 70-75
    • Postnov, A.A.1    Meurrens, K.2    Weiler, H.3    Van Dyck, D.4    Xu, H.5    Terpstra, P.6    De Clerck, N.M.7
  • 13
    • 33750568639 scopus 로고    scopus 로고
    • Optimized radiographic spectra for small animal digital subtraction angiography
    • DOI 10.1118/1.2356646
    • M. De Lin, E. Samei, C. Badea, and G. A. Johnson, " Optimized radiographic spectra for small animal digital subtraction angiography.," Med. Phys. 0094-2405 33, 4249-4257 (2006). 10.1118/1.2356646 (Pubitemid 44673114)
    • (2006) Medical Physics , vol.33 , Issue.11 , pp. 4249-4257
    • De Lin, M.1    Samei, E.2    Badea, C.T.3    Yoshizumi, T.T.4    Johnson, G.A.5
  • 14
    • 34247615131 scopus 로고    scopus 로고
    • Tomographic digital subtraction angiography for lung perfusion estimation in rodents
    • DOI 10.1118/1.2717384
    • C. T. Badea, L. W. Hedlund, M. De Lin, J. S. Mackel, E. Samei, and G. A. Johnson, " Tomographic digital subtraction angiography for lung perfusion estimation in rodents.," Med. Phys. 0094-2405 34, 1546-1555 (2007). 10.1118/1.2717384 (Pubitemid 46669151)
    • (2007) Medical Physics , vol.34 , Issue.5 , pp. 1546-1555
    • Badea, C.T.1    Hedlund, L.W.2    De Lin, M.3    Boslego MacKel, J.S.4    Samei, E.5    Allan Johnson, G.6
  • 15
    • 38949202992 scopus 로고    scopus 로고
    • Pulmonary perfusion imaging in the rodent lung using dynamic contrast-enhanced MRI
    • DOI 10.1002/mrm.21353
    • N. N. Mistry, J. Pollaro, J. Song, M. De Lin, and G. A. Johnson, " Pulmonary perfusion imaging in the rodent lung using dynamic contrast-enhanced MRI.," Magn. Reson. Med. 0740-3194 59, 289-297 (2008). 10.1002/mrm.21353 (Pubitemid 351220092)
    • (2008) Magnetic Resonance in Medicine , vol.59 , Issue.2 , pp. 289-297
    • Mistry, N.N.1    Pollaro, J.2    Song, J.3    Ming, D.L.4    Johnson, G.A.5
  • 17
    • 42949159662 scopus 로고    scopus 로고
    • Geometric calibration for a dual tube/detector micro-CT system
    • DOI 10.1118/1.2900000
    • S. Johnston, G. A. Johnson, and C. T. Badea, " Geometric calibration for a dual tube/detector micro-CT system.," Med. Phys. 0094-2405 35, 1820-1829 (2008). 10.1118/1.2900000 (Pubitemid 351614796)
    • (2008) Medical Physics , vol.35 , Issue.5 , pp. 1820-1829
    • Johnston, S.M.1    Johnson, G.A.2    Badea, C.T.3
  • 18
    • 39749124359 scopus 로고    scopus 로고
    • A high-precision contrast injector for small animal X-ray digital subtraction angiography
    • DOI 10.1109/TBME.2007.909541
    • M. Lin, L. Ning, C. T. Badea, N. N. Mistry, Y. Qi, and G. A. Johnson, " A high-precision contrast injector for small animal x-ray digital subtraction angiography.," IEEE Trans. Biomed. Eng. 0018-9294 55, 1082-1091 (2008). 10.1109/TBME.2007.909541 (Pubitemid 351301231)
    • (2008) IEEE Transactions on Biomedical Engineering , vol.55 , Issue.3 , pp. 1082-1091
    • Lin, M.D.1    Ning, L.2    Badea, C.T.3    Mistry, N.N.4    Qi, Y.5    Johnson, G.A.6
  • 19
    • 0036249129 scopus 로고    scopus 로고
    • Mechanical ventilation for imaging the small animal lung
    • 1084-2020.
    • L. W. Hedlund and G. A. Johnson, " Mechanical ventilation for imaging the small animal lung.," ILAR J. 1084-2020 43, 159-174 (2002).
    • (2002) ILAR J. , vol.43 , pp. 159-174
    • Hedlund, L.W.1    Johnson, G.A.2
  • 21
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis
    • DOI 10.1002/mrm.1910360510
    • L. stergaard, R. M. Weisskoff, D. A. Chesler, C. Gyldensted, and B. R. Rosen, " High resolution measurement of cerebral blood flow using intravascular tracer bolus passages: Part I. Mathematical approach and statistical analysis.," Magn. Reson. Med. 0740-3194 36, 715-725 (1996). 10.1002/mrm.1910360510 (Pubitemid 26376710)
    • (1996) Magnetic Resonance in Medicine , vol.36 , Issue.5 , pp. 715-725
    • Ostergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, G.4    Rosen, B.R.5
  • 22
    • 0034351119 scopus 로고    scopus 로고
    • Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware
    • 0278-0062. 10.1109/42.897815
    • K. Mueller and R. Yagel, " Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware.," IEEE Trans. Med. Imaging 0278-0062 19, 1227-1237 (2000). 10.1109/42.897815
    • (2000) IEEE Trans. Med. Imaging , vol.19 , pp. 1227-1237
    • Mueller, K.1    Yagel, R.2
  • 23
    • 0021445363 scopus 로고
    • Practical cone-beam algorithm
    • 0030-3941. 10.1364/JOSAA.1.000612
    • L. A. Feldkamp, L. C. Davis, and J. W. Kress, " Practical cone-beam algorithm.," J. Opt. Soc. Am. 0030-3941 1, 612-619 (1984). 10.1364/JOSAA.1.000612
    • (1984) J. Opt. Soc. Am. , vol.1 , pp. 612-619
    • Feldkamp, L.A.1    Davis, L.C.2    Kress, J.W.3
  • 24
    • 2942654916 scopus 로고    scopus 로고
    • Development of a 4-digital mouse phantom for molecular imaging research
    • DOI 10.1016/j.mibio.2004.03.002, PII S1536163204002173
    • W. P. Segars, B. M. W. Tsui, E. C. Frey, G. A. Johnson, and S. S. Berr, " Development of a 4-D digital mouse phantom for molecular imaging research.," Mol. Imaging Biol. 1536-1632 6, 149-159 (2004). 10.1016/j.mibio.2004.03.002 (Pubitemid 38771978)
    • (2004) Molecular Imaging and Biology , vol.6 , Issue.3 , pp. 149-159
    • Segars, W.P.1    Tsui, B.M.W.2    Frey, E.C.3    Johnson, G.A.4    Berr, S.S.5
  • 25
    • 17144369200 scopus 로고    scopus 로고
    • Optimized radiographic spectra for digital subtraction angiography in the mouse
    • Arlington, VA, (unpublished)
    • M. Lin, C. T. Badea, and G. A. Johnson, " Optimized radiographic spectra for digital subtraction angiography in the mouse.," IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Arlington, VA, 2004, Vol. 2, pp. 1412-1415 (unpublished).
    • (2004) IEEE International Symposium on Biomedical Imaging: From Nano to Macro , vol.2 , pp. 1412-1415
    • Lin, M.1    Badea, C.T.2    Johnson, G.A.3
  • 26
    • 49249094515 scopus 로고    scopus 로고
    • Application of MOSFET detectors for dosimetry in small animal radiography using short exposure times
    • 0033-7587. 10.1667/RR1328.1
    • M. Lin, G. Toncheva, G. Nguyen, S. Kim, C. Anderson-Evans, G. A. Johnson, and T. T. Yoshizumi, " Application of MOSFET detectors for dosimetry in small animal radiography using short exposure times.," Radiat. Res. 0033-7587 170, 260-263 (2008). 10.1667/RR1328.1
    • (2008) Radiat. Res. , vol.170 , pp. 260-263
    • Lin, M.1    Toncheva, G.2    Nguyen, G.3    Kim, S.4    Anderson-Evans, C.5    Johnson, G.A.6    Yoshizumi, T.T.7
  • 27
    • 33847411919 scopus 로고    scopus 로고
    • Small animal absorbed radiation dose from serial micro-computed tomography imaging
    • DOI 10.1007/s11307-007-0080-9
    • S. K. Carlson, K. L. Classic, C. E. Bender, and S. J. Russell, " Small animal absorbed radiation dose from serial micro-computed tomography imaging.," Mol. Imaging Biol. 1536-1632 9, 78-82 (2007). 10.1007/s11307-007-0080-9 (Pubitemid 46336222)
    • (2007) Molecular Imaging and Biology , vol.9 , Issue.2 , pp. 78-82
    • Carlson, S.K.1    Classic, K.L.2    Bender, C.E.3    Russell, S.J.4
  • 28
    • 0038354781 scopus 로고    scopus 로고
    • Effects of radiographic contrast media on the lung
    • DOI 10.1259/bjr/54892465
    • S. K. Morcos, " Review article: Effects of radiographic contrast media on the lung.," Br. J. Radiol. 0007-1285 76, 290-295 (2003). 10.1259/bjr/54892465 (Pubitemid 36826736)
    • (2003) British Journal of Radiology , vol.76 , Issue.905 , pp. 290-295
    • Morcos, S.K.1
  • 29
    • 35648981849 scopus 로고    scopus 로고
    • Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT
    • DOI 10.1118/1.2795830
    • J. Song, Q. H. Liu, G. A. Johnson, and C. T. Badea, " Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT.," Med. Phys. 0094-2405 34, 4476-4483 (2007). 10.1118/1.2795830 (Pubitemid 350029668)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4476-4483
    • Song, J.1    Liu, Q.H.2    Johnson, G.A.3    Badea, C.T.4
  • 30
    • 0035667862 scopus 로고    scopus 로고
    • Can we use vertical bore magnetic resonance scanners for murine cardiovascular phenotype characterization? Influence of upright body position on left ventricular hemodynamics in mice
    • DOI 10.1081/JCMR-100108584
    • F. Wiesmann, S. Neubauer, A. Haase, and L. Hein, " Can we use vertical bore magnetic resonance scanners for murine cardiovascular phenotype characterization? Influence of upright body position on left ventricular hemodynamics in mice.," J. Cardiovasc. Magn. Reson. 3, 311-315 (2001). 10.1081/JCMR-100108584 1097-6647 (Pubitemid 34031562)
    • (2001) Journal of Cardiovascular Magnetic Resonance , vol.3 , Issue.4 , pp. 311-315
    • Wiesmann, F.1    Neubauer, S.2    Haase, A.3    Hein, L.4
  • 32
    • 33644824867 scopus 로고    scopus 로고
    • CINE-MR imaging of the normal and infarcted rat heart using an 11.7 T vertical bore MR system
    • DOI 10.1080/10976640500451903, PII K021636618824
    • D. J. Tyler, C. A. Lygate, J. E. Schneider, P. J. Cassidy, S. Neubauer, and K. Clarke, " CINE-MR imaging of the normal and infarcted rat heart using an 11.7 T vertical bore MR system.," J. Cardiovasc. Magn. Reson. 8, 327-333 (2006). 10.1080/10976640500451903 1097-6647 (Pubitemid 43355105)
    • (2006) Journal of Cardiovascular Magnetic Resonance , vol.8 , Issue.2 , pp. 327-333
    • Tyler, D.1    Lygate, C.2    Schneider, J.3    Cassidy, P.4    Neubauer, S.5    Clarke, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.