-
1
-
-
84864611623
-
-
Blood GlucoseMeters. (2010), Online.Available: http://www.diabetesnet. com/diabetes-technology/meters-monitors/blood-glucose-meters
-
(2010)
Blood GlucoseMeters
-
-
-
2
-
-
58349120590
-
Continuous glucose monitoring: A review of biochemical perspectives and clinical use in type 1 diabetes
-
Feb
-
C.M. Girardin, C. Huot,M. Gonthier, and E. Delvin, "Continuous glucose monitoring: A review of biochemical perspectives and clinical use in type 1 diabetes," Clin. Biochem., vol. 42, no. 3, pp. 136-142, Feb. 2009.
-
(2009)
Clin. Biochem.
, vol.42
, Issue.3
, pp. 136-142
-
-
Girardin, C.M.1
Huotm. Gonthier, C.2
Delvin, E.3
-
3
-
-
0034491769
-
Analysis of ultrasonically extracted interstitial fluid as a predictor of blood glucose levels
-
S. Mitragotri, M. Coleman, J. Kost, and R. Langer, "Analysis of ultrasonically extracted interstitial fluid as a predictor of blood glucose levels," J. Appl. Physiol., vol. 89, no. 3, pp. 961-966, Sep. 2000. (Pubitemid 32125394)
-
(2000)
Journal of Applied Physiology
, vol.89
, Issue.3
, pp. 961-966
-
-
Mitragotri, S.1
Coleman, M.2
Kost, J.3
Langer, R.4
-
4
-
-
0037066415
-
Glucose gradient differences in subcutaneous tissue of healthy volunteers assessed with ultraslow microdialysis and a nanolitre glucose sensor
-
DOI 10.1016/S0024-3205(02)01515-1, PII S0024320502015151
-
R. G. Tiessen, M. M. Rhemrev-Boom, and J. Korf, "Glucose gradient differences in subcutaneous tissue of healthy volunteers assessed with ultraslow microdialysis and a nanolitre glucose sensor," Life Sci., vol. 70, pp. 2457-2466, 2002. (Pubitemid 34267035)
-
(2002)
Life Sciences
, vol.70
, Issue.21
, pp. 2457-2466
-
-
Tiessen, R.G.1
Rhemrev-Boom, M.M.2
Korf, J.3
-
5
-
-
0032882086
-
Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes
-
DOI 10.2337/diacare.22.10.1708
-
S. K. Garg, S. J. Fermi, R. O. Potts, J. A. Tamada, N. R. Ackerman, and H. P. Chase, "Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes," Diabetes Care, vol. 22, no. 10, pp. 1708-1714, Oct. 1999. (Pubitemid 29458398)
-
(1999)
Diabetes Care
, vol.22
, Issue.10
, pp. 1708-1714
-
-
Garg, S.K.1
Potts, R.O.2
Ackerman, N.R.3
Fermi, S.J.4
Tamada, J.A.5
Chase, H.P.6
-
6
-
-
12444301362
-
Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum
-
DOI 10.1089/152091503321827812
-
S. Gebhart, M. Faupel, R. Fowler, C. Kapsner, D. Lincoln, V. McGee, J. Pasqua, L. Steed, M. Wangsness, F. Xu, and M. Vanstory, "Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum," Diabetes Technol. Therapeutics, vol. 5, no. 2, pp. 159-166, Jul. 2004. (Pubitemid 36617645)
-
(2003)
Diabetes Technology and Therapeutics
, vol.5
, Issue.2
, pp. 159-166
-
-
Gebhart, S.1
Faupel, M.2
Fowler, R.3
Kapsner, C.4
Lincoln, D.5
McGee, V.6
Pasqua, J.7
Steed, L.8
Wangsness, M.9
Xu, F.10
Vanstory, M.11
-
7
-
-
4243108935
-
A microneedle-based glucose monitor: Fabricated on a wafer-level using in-device enzyme immobilization
-
S. Zimmermann, D. Fienbork, B. Stoeber, A. W. Flounders, and D. Liepmann, "A microneedle-based glucose monitor: Fabricated on a wafer-level using in-device enzyme immobilization," in Proc. Transducers, 2003, pp. 99-102.
-
(2003)
Proc. Transducers
, pp. 99-102
-
-
Zimmermann, S.1
Fienbork, D.2
Stoeber, B.3
Flounders, A.W.4
Liepmann, D.5
-
8
-
-
34247134514
-
Non-invasive glucose monitoring: Assessment of technologies and devices according to quantitative criteria
-
DOI 10.1016/j.diabres.2006.10.027, PII S0168822706004931
-
A. Tura, A. Maran, and G. Pacini, "Non-invasive glucose monitoring: Assessment of technologies and devices according to quantitative criteria," Diabetes Res. Clin. Pract., vol. 77, no. 1, pp. 16-40, Jul. 2007. (Pubitemid 46590478)
-
(2007)
Diabetes Research and Clinical Practice
, vol.77
, Issue.1
, pp. 16-40
-
-
Tura, A.1
Maran, A.2
Pacini, G.3
-
9
-
-
14844345011
-
Noninvasive and minimally invasive methods for transdermal glucose monitoring
-
DOI 10.1089/dia.2005.7.174
-
A. Sieg, R. H. Guy, and M. B. Delgado-Charro, "Noninvasive and minimally invasive methods for transdermal glucose monitoring," Diabetes Technol. Therapeutics, vol. 7, no. 7, pp. 174-197, 2005. (Pubitemid 40354587)
-
(2005)
Diabetes Technology and Therapeutics
, vol.7
, Issue.1
, pp. 174-197
-
-
Sieg, A.1
Guy, R.H.2
Delgado-Charro, M.B.3
-
10
-
-
77949879803
-
New features and performance of a next-generation seven-day continuous glucose monitoring system with short lag time
-
Dec
-
T. Bailey, H. Zisser, and A. Chang, "New features and performance of a next-generation seven-day continuous glucose monitoring system with short lag time," Diabetes Technol. Therapeutics, vol. 11, no. 12, pp. 749-755, Dec. 2009.
-
(2009)
Diabetes Technol. Therapeutics
, vol.11
, Issue.12
, pp. 749-755
-
-
Bailey, T.1
Zisser, H.2
Chang, A.3
-
11
-
-
50049108982
-
The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes
-
Oct
-
J. Mastrototaro, J. Shin, A. Marcus, and G. Sulur, "The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes," Diabetes Technol. Therapeutics, vol. 10, no. 5, pp. 385-390, Oct. 2008.
-
(2008)
Diabetes Technol. Therapeutics
, vol.10
, Issue.5
, pp. 385-390
-
-
Mastrototaro, J.1
Shin, J.2
Marcus, A.3
Sulur, G.4
-
12
-
-
34247600583
-
Accuracy of the 5-day FreeStyle navigator continuous glucose monitoring system
-
May
-
R. L. Weinstein, S. L. Schwartz, R. L. Brazg, J. R. Bugler, T. A. Peyser, and G. V. McGarraugh, "Accuracy of the 5-day FreeStyle navigator continuous glucose monitoring system," Diabetes Care, vol. 30, no. 5, pp. 1125-1130, May 2007.
-
(2007)
Diabetes Care
, vol.30
, Issue.5
, pp. 1125-1130
-
-
Weinstein, R.L.1
Schwartz, S.L.2
Brazg, R.L.3
Bugler, J.R.4
Peyser, T.A.5
McGarraugh, G.V.6
-
13
-
-
14644392814
-
In vivo glucose monitoring: The clinical reality and the promise
-
DOI 10.1016/j.bios.2004.08.016, PII S0956566304003847
-
J. C. Pickup, F. Hussain, N. D. Evans, and N. Sachedina, "In vivo glucose monitoring: The clinical reality and the promise," Biosens. Bioelectron., vol. 20, no. 10, pp. 1897-1902, Apr. 2005. (Pubitemid 40312083)
-
(2005)
Biosensors and Bioelectronics
, vol.20
, Issue.10 SPEC. ISS.
, pp. 1897-1902
-
-
Pickup, J.C.1
Hussain, F.2
Evans, N.D.3
Sachedina, N.4
-
14
-
-
0034061329
-
Transdermal monitoring of glucose and other analytes using ultrasound
-
DOI 10.1038/73213
-
J. Kost, S. Mitragotri, R. A. Gabbay, M. Pishko, and R. Langer, "Transdermal monitoring of glucose and other analytes using ultrasound," Nat. Med., vol. 6, no. 3, pp. 347-350, Mar. 2000. (Pubitemid 30148630)
-
(2000)
Nature Medicine
, vol.6
, Issue.3
, pp. 347-350
-
-
Kost, J.1
Mitragotri, S.2
Gabbay, R.A.3
Pishko, M.4
Langer, R.5
-
15
-
-
33745844749
-
Current developments using emerging transdermal technologies in physical enhancement methods
-
DOI 10.2174/156720106777731091
-
A. Nanda, S. Nanda, and N. M. K. Ghilzai, "Current developments using emerging transdermal technologies in physical enhancement methods," Current Drug Del., vol. 3, no. 3, pp. 233-242, Jul. 2006. (Pubitemid 44031622)
-
(2006)
Current Drug Delivery
, vol.3
, Issue.3
, pp. 233-242
-
-
Nanda, A.1
Nanda, S.2
Ghilzai, N.M.K.3
-
16
-
-
17844373273
-
Transdermal drug delivery: Penetration enhancement techniques
-
DOI 10.2174/1567201052772915
-
H. Benson, "Transdermal drug delivery: Penetration enhancement techniques," Current Drug Del., vol. 2, no. 1, pp. 23-33, Jan. 2005. (Pubitemid 40590918)
-
(2005)
Current Drug Delivery
, vol.2
, Issue.1
, pp. 23-33
-
-
Benson, H.A.E.1
-
17
-
-
0031937875
-
Characterization of the transport pathways induced during low to moderate voltage iontophoresis in human epidermal membrane
-
DOI 10.1021/js970189l
-
S. K. Li, A. Ghanem, K. D. Peck, and W. I. Higuchi, " Characterization of the transport pathways induced during low to moderate voltage iontophoresis in human epidermal membrane," J. Pharm. Sci., vol. 87, no. 1, pp. 40-48, Jan. 1998. (Pubitemid 28079259)
-
(1998)
Journal of Pharmaceutical Sciences
, vol.87
, Issue.1
, pp. 40-48
-
-
Li, S.K.1
Ghanem, A.-H.2
Peck, K.D.3
Higuchi, W.I.4
-
18
-
-
0029918482
-
Transdermal drug delivery using low-frequency sonophoresis
-
DOI 10.1023/A:1016096626810
-
S. Mitragotri, D. Blankschtein, and R. Langer, "Transdermal drug delivery using low-frequency sonophoresis," Pharm. Res., vol. 13, no. 3, pp. 411-420, Mar. 1996. (Pubitemid 26114728)
-
(1996)
Pharmaceutical Research
, vol.13
, Issue.3
, pp. 411-420
-
-
Mitragotri, S.1
Blankschtein, D.2
Langer, R.3
-
19
-
-
67650260349
-
Recovery of skin barrier properties after sonication in human subjects
-
Aug
-
J. Gupta and M. R. Prausnitz, "Recovery of skin barrier properties after sonication in human subjects," Ultrasound Med. Biol., vol. 35, no. 8, pp. 1405-1408, Aug. 2009.
-
(2009)
Ultrasound Med. Biol.
, vol.35
, Issue.8
, pp. 1405-1408
-
-
Gupta, J.1
Prausnitz, M.R.2
-
20
-
-
84864602856
-
Using skin impedance to improve prediction accuracy of continuous glucose monitoring system
-
H. Yu, J. Liu, T. Shi, D. Li, Z. Du, and K. Xu, "Using skin impedance to improve prediction accuracy of continuous glucose monitoring system," in Proc. SPIE, 2008, p. 686 30S.
-
(2008)
Proc. SPIE
-
-
Yu, H.1
Liu, J.2
Shi, T.3
Li, D.4
Du, Z.5
Xu, K.6
-
21
-
-
34748821880
-
Characterizing and patterning of PDMS-based conducting composites
-
DOI 10.1002/adma.200602515
-
X. Niu, S. Peng, L. Liu, W. Wen, and P. Sheng, "Characterizing and patterning of PDMS-based conducting composites," Adv. Mater., vol. 19, no. 18, pp. 2682-2686, Sep. 2007. (Pubitemid 47481836)
-
(2007)
Advanced Materials
, vol.19
, Issue.18
, pp. 2682-2686
-
-
Niu, X.1
Peng, S.2
Liu, L.3
Wen, W.4
Sheng, P.5
-
22
-
-
77951923493
-
Measurement of glucose concentration by surface plasmon resonance with D-galactose/D-glucose binding protein
-
F. Huang, D. Li, B. Song, P. Wu, J. Zhang, and K. Xu, "Measurement of glucose concentration by surface plasmon resonance with D-galactose/D-glucose binding protein," Nanotechnol. Precision Eng., vol. 8, pp. 132-136, 2010.
-
(2010)
Nanotechnol. Precision Eng.
, vol.8
, pp. 132-136
-
-
Huang, F.1
Li, D.2
Song, B.3
Wu, P.4
Zhang, J.5
Xu, K.6
|