메뉴 건너뛰기




Volumn 19, Issue 3, 2012, Pages 400-414

St George's vascular institute protocol: An accurate and reproducible methodology to enable comprehensive characterization of infrarenal abdominal aortic aneurysm morphology in clinical and research applications

Author keywords

3D imaging; Abdominal aortic aneurysm; Access vessels; Aneurysm sac; Aortic neck; Calcification; Common iliac arteries; Computed tomographic angiography; Dimensions; Endovascular aneurysm repair; Morphological assessment; Observer variability; Tortuosity

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ACCURACY; ADULT; AGED; ARTICLE; CALCIFICATION; CLINICAL ARTICLE; CLINICAL ASSESSMENT; CLINICAL PROTOCOL; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTER PROGRAM; ENDOVASCULAR ANEURYSM REPAIR; FEMALE; HUMAN; ILIAC ARTERY; IMAGE RECONSTRUCTION; MALE; METHODOLOGY; OBSERVER VARIATION; PREOPERATIVE PERIOD; PRIORITY JOURNAL; REPRODUCIBILITY; VALIDATION STUDY;

EID: 84864537042     PISSN: 15266028     EISSN: 15451550     Source Type: Journal    
DOI: 10.1583/11-3731MR.1     Document Type: Article
Times cited : (48)

References (34)
  • 1
    • 33645885342 scopus 로고    scopus 로고
    • Consistency in endovascular aneurysm repair suitability assessment requires group decision audit
    • Rödel SG, Geelkerken RH, van Herwaarden JA, et al. Consistency in endovascular aneurysm repair suitability assessment requires group decision audit. J Vasc Surg. 2006;43:671-676.
    • (2006) J Vasc Surg , vol.43 , pp. 671-676
    • Rödel, S.G.1    Geelkerken, R.H.2    Van Herwaarden, J.A.3
  • 2
    • 34347229450 scopus 로고    scopus 로고
    • Factors Affecting Survival after Endovascular Aneurysm Repair: Results from a Population Based Audit
    • DOI 10.1016/j.ejvs.2007.02.020, PII S1078588407001876
    • Boult M, Maddern G, Barnes M, et al. Factors affecting survival after endovascular aneurysm repair: results from a population based audit. Eur J Vasc Endovasc Surg. 2007;34:156-162. (Pubitemid 47007436)
    • (2007) European Journal of Vascular and Endovascular Surgery , vol.34 , Issue.2 , pp. 156-162
    • Boult, M.1    Maddern, G.2    Barnes, M.3    Fitridge, R.4
  • 3
    • 38749096232 scopus 로고    scopus 로고
    • Endovascular repair of abdominal aortic aneurysm
    • Greenhalgh RM, Powell JT. Endovascular repair of abdominal aortic aneurysm. N Engl J Med. 2008;358:494-501.
    • (2008) N Engl J Med. , vol.358 , pp. 494-501
    • Greenhalgh, R.M.1    Powell, J.T.2
  • 5
    • 79959290152 scopus 로고    scopus 로고
    • Pragmatic minimum reporting standards for endovascular abdominal aortic aneurysm repair
    • Boyle JR, Thompson MM, Vallabhaneni SR, et al. Pragmatic minimum reporting standards for endovascular abdominal aortic aneurysm repair. J Endovasc Ther. 2011;18:263-271.
    • (2011) J Endovasc Ther , vol.18 , pp. 263-271
    • Boyle, J.R.1    Thompson, M.M.2    Vallabhaneni, S.R.3
  • 7
    • 33847176605 scopus 로고    scopus 로고
    • Influence of severe infrarenal aortic neck angulation on complications at the proximal neck following endovascular AAA repair: A EUROSTAR study
    • Hobo R, Kievit J, Leurs LJ, et al. Influence of severe infrarenal aortic neck angulation on complications at the proximal neck following endovascular AAA repair: a EUROSTAR study. J Endovasc Ther . 2007;14:1-11.
    • (2007) J Endovasc Ther , vol.14 , pp. 1-11
    • Hobo, R.1    Kievit, J.2    Leurs, L.J.3
  • 10
    • 0036518028 scopus 로고    scopus 로고
    • Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair
    • DOI 10.1067/mva.2002.119506
    • Sternbergh WC, Carter G, York JW, et al. Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair. J Vasc Surg . 2002;35:482-486. (Pubitemid 44718591)
    • (2002) Journal of Vascular Surgery , vol.35 , Issue.3 , pp. 482-486
    • Sternbergh III, W.C.1    Carter, G.2    York, J.W.3    Yoselevitz, M.4    Money, S.R.5
  • 12
    • 33846657728 scopus 로고    scopus 로고
    • Endovascular abdominal aortic aneurysm sizing and case planning using the TeraRecon aquarius workstation
    • DOI 10.1177/1538574406296244
    • Lee WA. Endovascular abdominal aortic aneurysm sizing and case planning using the Tera- Recon Aquarius workstation. Vasc Endovascular Surg. 2007;41:61-67. (Pubitemid 46198605)
    • (2007) Vascular and Endovascular Surgery , vol.41 , Issue.1 , pp. 61-67
    • Lee, W.A.1
  • 13
    • 56349165708 scopus 로고    scopus 로고
    • Intra- and interobserver variability of aortic aneurysm volume measurement with fast CTA postprocessing software
    • van Prehn J, van der Wal MB, Vincken K, et al. Intra- and interobserver variability of aortic aneurysm volume measurement with fast CTA postprocessing software. J Endovasc Ther. 2008;15:504-510.
    • (2008) J Endovasc Ther , vol.15 , pp. 504-510
    • Van Prehn, J.1    Van Der Wal, M.B.2    Vincken, K.3
  • 14
    • 77949897451 scopus 로고    scopus 로고
    • Validation of a new standardized method to measure proximal aneurysm neck angulation
    • van Keulen JW, Moll FL, Tolenaar JL, et al. Validation of a new standardized method to measure proximal aneurysm neck angulation. J Vasc Surg. 2010;51:821-828.
    • (2010) J Vasc Surg , vol.51 , pp. 821-828
    • Van Keulen, J.W.1    Moll, F.L.2    Tolenaar, J.L.3
  • 15
    • 79952992342 scopus 로고    scopus 로고
    • Clinical validation of a software for quantitative follow-up of abdominal aortic aneurysm maximal diameter and growth by CT angiography
    • Kauffmann C, Tang A, Dugas A, et al. Clinical validation of a software for quantitative follow-up of abdominal aortic aneurysm maximal diameter and growth by CT angiography. Eur J Radiol. 2011;77:502-508.
    • (2011) Eur J Radiol , vol.77 , pp. 502-508
    • Kauffmann, C.1    Tang, A.2    Dugas, A.3
  • 16
    • 84872208562 scopus 로고    scopus 로고
    • A systematic review of protocols for the three-dimensional morphologic assessment of abdominal aortic aneurysms using computed tomographic angiography
    • Dec 10. [Epub ahead of print]
    • Ghatwary TM, Patterson BO, Karthikesalingam A, et al. A systematic review of protocols for the three-dimensional morphologic assessment of abdominal aortic aneurysms using computed tomographic angiography. Cardiovasc Intervent Radiol. 2011 Dec 10. [Epub ahead of print]
    • (2011) Cardiovasc Intervent Radiol
    • Ghatwary, T.M.1    Patterson, B.O.2    Karthikesalingam, A.3
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 27644592801 scopus 로고    scopus 로고
    • Aneurysm diameter and proximal aortic neck diameter influence clinical outcome of endovascular abdominal aortic repair: A 4-year EUROSTAR experience
    • DOI 10.1007/s10016-005-7971-5
    • Waasdorp EJ, Vries JP, Hobo R, et al. Aneurysm diameter and proximal aortic neck diameter influence clinical outcome of endovascular abdominal aortic repair: a 4-year EUROSTAR experience. Ann Vasc Surg. 2005;19:755-761. (Pubitemid 41570044)
    • (2005) Annals of Vascular Surgery , vol.19 , Issue.6 , pp. 755-761
    • Waasdorp, E.J.1    De Vries, J.-P.P.M.2    Hobo, R.3    Leurs, L.J.4    Buth, J.5    Moll, F.L.6
  • 20
    • 41549094084 scopus 로고    scopus 로고
    • A Model to Predict Outcomes for Endovascular Aneurysm Repair Using Preoperative Variables
    • DOI 10.1016/j.ejvs.2007.12.003, PII S1078588407007526
    • Barnes M, Boult M, Maddern G, et al. A model to predict outcomes for endovascular aneurysm repair using preoperative variables. Eur J Vasc Endovasc Surg. 2008;35:571-579. (Pubitemid 351469941)
    • (2008) European Journal of Vascular and Endovascular Surgery , vol.35 , Issue.5 , pp. 571-579
    • Barnes, M.1    Boult, M.2    Maddern, G.3    Fitridge, R.4
  • 21
    • 77958592721 scopus 로고    scopus 로고
    • A 5-year comparison of EVAR for large and small aortic necks
    • Jim J, Rubin BG, Geraghty PJ, et al. A 5-year comparison of EVAR for large and small aortic necks. J Endovasc Ther. 2010;17:575-584.
    • (2010) J Endovasc Ther , vol.17 , pp. 575-584
    • Jim, J.1    Rubin, B.G.2    Geraghty, P.J.3
  • 22
    • 33751008341 scopus 로고    scopus 로고
    • Influence of infrarenal neck length on outcome of endovascular abdominal aortic aneurysm repair
    • DOI 10.1583/06-1882.1
    • Leurs LJ, Kievit J, Dagnelie PC, et al. Influence of infrarenal neck length on outcome of endovascular abdominal aortic aneurysm repair. J Endovasc Ther. 2006;13:640-648. (Pubitemid 44749195)
    • (2006) Journal of Endovascular Therapy , vol.13 , Issue.5 , pp. 640-648
    • Leurs, L.J.1    Kievit, J.2    Dagnelie, P.C.3    Nelemans, P.J.4    Buth, J.5
  • 23
    • 30344472418 scopus 로고    scopus 로고
    • Adverse events at the aneurysmal neck identified at follow-up after endovascular abdominal aortic aneursym repair: How do they correlate?
    • Leurs LJ, Stultiens G, Kievit J, et al. Adverse events at the aneurysmal neck identified at follow-up after endovascular abdominal aortic aneurysm repair: how do they correlate? Vascular. 2005;13:261-267. (Pubitemid 43057799)
    • (2005) Vascular , vol.13 , Issue.5 , pp. 261-267
    • Leurs, L.J.1    Stultiens, G.2    Kievit, J.3    Buth, J.4
  • 24
    • 49749101185 scopus 로고    scopus 로고
    • Sixty-four- Detector CT angiography of infrarenal aortic neck length and angulation: Prospective analysis of interobserver variability
    • Diehm N, Katzen BT, Samuels S, et al. Sixty-four- detector CT angiography of infrarenal aortic neck length and angulation: prospective analysis of interobserver variability. J Vasc Interv Radiol. 2008;19:1283-1288.
    • (2008) J Vasc Interv Radiol , vol.19 , pp. 1283-1288
    • Diehm, N.1    Katzen, B.T.2    Samuels, S.3
  • 26
    • 71649111814 scopus 로고    scopus 로고
    • Three-dimensional imaging core laboratory of the endovascular aneurysm repair trials: Validation of methodology
    • Wyss TR, Dick F, England A, et al. Three-dimensional imaging core laboratory of the endovascular aneurysm repair trials: validation of methodology. Eur J Vasc Endovasc Surg. 2009;38:724-731.
    • (2009) Eur J Vasc Endovasc Surg , vol.38 , pp. 724-731
    • Wyss, T.R.1    Dick, F.2    England, A.3
  • 27
    • 7244254266 scopus 로고    scopus 로고
    • Multidetector CT angiography versus digital subtraction angiography for aortoiliac length measurements prior to endovascular AAA repair
    • DOI 10.1583/03-1172.1
    • Diehm N, Herrmann P, Dinkel HP. Multidetector CT angiography versus digital subtraction angiography for aortoiliac length measurements prior to endovascular AAA repair. J Endovasc Ther. 2004;11:527-534. (Pubitemid 39435080)
    • (2004) Journal of Endovascular Therapy , vol.11 , Issue.5 , pp. 527-534
    • Diehm, N.1    Herrmann, P.2    Dinkel, H.-P.3
  • 28
    • 0037345954 scopus 로고    scopus 로고
    • Evaluation of aortoiliac aneurysm before endovascular repair: Comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool
    • DOI 10.1067/mva.2003.143
    • Lutz AM, Willmann JK, Pfammatter T, et al. Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool. J Vasc Surg. 2003;37:619-627. (Pubitemid 36350909)
    • (2003) Journal of Vascular Surgery , vol.37 , Issue.3 , pp. 619-627
    • Lutz, A.M.1    Willmann, J.K.2    Pfammatter, T.3    Lachat, M.4    Wildermuth, S.5    Marincek, B.6    Weishaupt, D.7
  • 29
    • 0035489379 scopus 로고    scopus 로고
    • Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: Evaluation of 3D computer-based assessment
    • DOI 10.1067/mva.2001.118586
    • Wolf YG, Tillich M, Lee WA, et al. Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: evaluation of 3D computer-based assessment. J Vasc Surg. 2001;34:594-599. (Pubitemid 33664905)
    • (2001) Journal of Vascular Surgery , vol.34 , Issue.4 , pp. 594-599
    • Wolf, Y.G.1    Tillich, M.2    Lee, W.A.3    Rubin, G.D.4    Fogarty, T.J.5    Zarins, C.K.6
  • 31
    • 0038044566 scopus 로고    scopus 로고
    • Three-dimensional CT evaluation for endovascular abdominal aortic aneurysm repair. Quantitative assessment of the infrarenal aortic neck
    • Filis KA, Arko FR, Rubin GD, et al. Three-dimensional CT evaluation for endovascular abdominal aortic aneurysm repair. Quantitative assessment of the infrarenal aortic neck. Acta Chir Belg. 2003;103:81-86. (Pubitemid 38340204)
    • (2003) Acta Chirurgica Belgica , vol.103 , Issue.1 , pp. 81-86
    • Filis, K.A.1    Arko, F..R.2    Rubin, G.D.3    Zarins, C.K.4
  • 32
    • 34247621942 scopus 로고    scopus 로고
    • Thrombus and calcium in aortic aneurysm necks: Validation of a scoring system in a Dutch cohort study
    • DOI 10.1177/1538574406298081
    • Tournoij E, Slisatkorn W, Prokop M, et al. Thrombus and calcium in aortic aneurysm necks: validation of a scoring system in a Dutch cohort study. Vasc Endovascular Surg. 2007;41:120-125. (Pubitemid 46669138)
    • (2007) Vascular and Endovascular Surgery , vol.41 , Issue.2 , pp. 120-125
    • Tournoij, E.1    Slisatkorn, W.2    Prokop, M.3    Verhagen, H.J.M.4    Moll, F.L.5
  • 34
    • 58849123366 scopus 로고    scopus 로고
    • Interobserver variability in the measurement of abdominal aortic calcification using unenhanced CT
    • Bowden DJ, Aitken SR, Wilkinson IB, et al. Interobserver variability in the measurement of abdominal aortic calcification using unenhanced CT. Br J Radiol. 2009;82(973):69-72.
    • (2009) Br J Radiol. , vol.82 , Issue.973 , pp. 69-72
    • Bowden, D.J.1    Aitken, S.R.2    Wilkinson, I.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.