-
2
-
-
0038710648
-
Guidelines for the treatment of abdominal aortic aneurysms: Report of a subcommittee of the Joint Council of the American Association for Vascular Surgery and Society for Vascular Surgery
-
DOI 10.1067/mva.2003.363
-
D.C. Brewster, J.L. Cronenwett, and J.W. Hallett Jr. Guidelines for the treatment of abdominal aortic aneurysms. Report of a subcommittee of the Joint Council of the American Association for Vascular Surgery and Society for Vascular Surgery J Vasc Surg 37 5 2003 1106 1117 (Pubitemid 36538940)
-
(2003)
Journal of Vascular Surgery
, vol.37
, Issue.5
, pp. 1106-1117
-
-
Brewster, D.C.1
Cronenwett, J.L.2
Hallett Jr., J.W.3
Johnston, K.W.4
Krupski, W.C.5
Matsumura, J.S.6
-
3
-
-
0035107009
-
Risk factors for rupture of abdominal aortic aneurysm based on three-dimensional study
-
DOI 10.1067/mva.2001.111731
-
T. Hatakeyama, H. Shigematsu, and T. Muto Risk factors for rupture of abdominal aortic aneurysm based on three-dimensional study J Vasc Surg 33 3 2001 453 461 (Pubitemid 32215591)
-
(2001)
Journal of Vascular Surgery
, vol.33
, Issue.3
, pp. 453-461
-
-
Hatakeyama, T.1
Shigematsu, H.2
Muto, T.3
-
4
-
-
0037345954
-
Evaluation of aortoiliac aneurysm before endovascular repair: Comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool
-
DOI 10.1067/mva.2003.143
-
A.M. Lutz, J.K. Willmann, and T. Pfammatter Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool J Vasc Surg 37 3 2003 619 627 (Pubitemid 36350909)
-
(2003)
Journal of Vascular Surgery
, vol.37
, Issue.3
, pp. 619-627
-
-
Lutz, A.M.1
Willmann, J.K.2
Pfammatter, T.3
Lachat, M.4
Wildermuth, S.5
Marincek, B.6
Weishaupt, D.7
-
5
-
-
0029060108
-
Variability in measurement of abdominal aortic aneurysms. Abdominal Aortic Aneurysm Detection and Management Veterans Administration Cooperative Study Group
-
F.A. Lederle, S.E. Wilson, and G.R. Johnson Variability in measurement of abdominal aortic aneurysms. Abdominal Aortic Aneurysm Detection and Management Veterans Administration Cooperative Study Group J Vasc Surg 21 6 1995 945 952
-
(1995)
J Vasc Surg
, vol.21
, Issue.6
, pp. 945-952
-
-
Lederle, F.A.1
Wilson, S.E.2
Johnson, G.R.3
-
6
-
-
0036403252
-
Accuracy of serial screening for abdominal aortic aneurysms by ultrasound
-
A.B. Wilmink, M. Forshaw, and C.R. Quick Accuracy of serial screening for abdominal aortic aneurysms by ultrasound J Med Screen 9 3 2002 25 27
-
(2002)
J Med Screen
, vol.9
, Issue.3
, pp. 25-27
-
-
Wilmink, A.B.1
Forshaw, M.2
Quick, C.R.3
-
7
-
-
33748628567
-
Correlation between the measurement of transverse diameter in the proximal neck on computed tomography and on aortography before endovascular treatment of infrarenal aortic aneurysm
-
M.M. de Gracia, B. Rodriguez-Vigil, and G. Garzon-Moll Correlation between the measurement of transverse diameter in the proximal neck on computed tomography and on aortography before endovascular treatment of infrarenal aortic aneurysm Ann Vasc Surg 20 4 2006 8 95
-
(2006)
Ann Vasc Surg
, vol.20
, Issue.4
, pp. 8-95
-
-
De Gracia, M.M.1
Rodriguez-Vigil, B.2
Garzon-Moll, G.3
-
8
-
-
49049114477
-
Measurement and determinants of infrarenal aortic thrombus volume
-
J. Golledge, P. Wolanski, and A. Parr Measurement and determinants of infrarenal aortic thrombus volume Eur Radiol 15 2008
-
(2008)
Eur Radiol
-
-
Golledge, J.1
Wolanski, P.2
Parr, A.3
-
10
-
-
35148896924
-
Semi-automatic aortic aneurysm analysis
-
O. Bodur, L. Grady, and A. Stillman Semi-automatic aortic aneurysm analysis A. Manduca, X. Hu, Medical imaging 2007: physiology, function, and structure from medical images 2007
-
(2007)
Medical Imaging 2007: Physiology, Function, and Structure from Medical Images
-
-
Bodur, O.1
Grady, L.2
Stillman, A.3
-
11
-
-
34047115405
-
Aortic thrombus segmentation using narrow band active contour model
-
DOI 10.1109/IEMBS.2006.260125, 4029276, 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
-
B. Das, Y. Mallya, and S. Srikanth Aortic thrombus segmentation using narrow band active contour model Conf Proc IEEE Eng Med Biol Soc 1 2006 408 411 (Pubitemid 46519886)
-
(2006)
Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
, pp. 408-411
-
-
Das, B.1
Mallya, Y.2
Srikanth, S.3
Malladi, R.4
-
12
-
-
17444407892
-
Segmentation of thrombus in abdominal aortic aneurysms from CTA with nonparametric statistical grey level appearance modeling
-
DOI 10.1109/TMI.2004.843260, Vascular Imaging
-
S.D. Olabarriaga, J.M. Rouet, and M. Fradkin Segmentation of thrombus in abdominal aortic aneurysms from CTA with nonparametric statistical grey level appearance modeling IEEE Trans Med Imaging 24 4 2005 477 485 (Pubitemid 40538205)
-
(2005)
IEEE Transactions on Medical Imaging
, vol.24
, Issue.4
, pp. 477-485
-
-
Olabarriaga, S.D.1
Rouet, J.-M.2
Fradkin, M.3
Breeuwer, M.4
Niessen, W.J.5
-
13
-
-
27144531559
-
Model-based quantitative AAA image analysis using a priori knowledge
-
DOI 10.1016/j.cmpb.2005.06.009, PII S0169260705001240
-
M. Subasic, S. Loncaric, and E. Sorantin Model-based quantitative AAA image analysis using a priori knowledge Comput Methods Programs Biomed 80 2 2005 103 114 (Pubitemid 41501434)
-
(2005)
Computer Methods and Programs in Biomedicine
, vol.80
, Issue.2
, pp. 103-114
-
-
Subasic, M.1
Loncaric, S.2
Sorantin, E.3
-
14
-
-
33646440020
-
An abdominal aortic aneurysm segmentation method: Level set with region and statistical information
-
F. Zhuge, G.D. Rubin, and S. Sun An abdominal aortic aneurysm segmentation method: level set with region and statistical information Med Phys 33 5 2006 1440 1453
-
(2006)
Med Phys
, vol.33
, Issue.5
, pp. 1440-1453
-
-
Zhuge, F.1
Rubin, G.D.2
Sun, S.3
-
15
-
-
0017360990
-
The measurement of observer agreement for categorical data
-
J.R. Landis, and G.G. Koch The measurement of observer agreement for categorical data Biometrics 33 1 1977 159 174 (Pubitemid 8054849)
-
(1977)
Biometrics
, vol.33
, Issue.1
, pp. 159-174
-
-
Landis, J.R.1
Koch, G.G.2
-
16
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
PII S0140673686908378
-
J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 8476 1986 307 310 (Pubitemid 16134762)
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
17
-
-
12144287134
-
Variability of maximal aortic aneurysm diameter measurements on CT scan: Significance and methods to minimize
-
DOI 10.1016/j.jvs.2003.11.042
-
N.S. Cayne, F.J. Veith, and E.C. Lipsitz Variability of maximal aortic aneurysm diameter measurements on CT scan: significance and methods to minimize J Vasc Surg 39 4 2004 811 815 (Pubitemid 38405813)
-
(2004)
Journal of Vascular Surgery
, vol.39
, Issue.4
, pp. 811-815
-
-
Cayne, N.S.1
Veith, F.J.2
Lipsitz, E.C.3
Ohki, T.4
Mehta, M.5
Gargiulo, N.6
Suggs, W.D.7
Rozenblit, A.8
Ricci, Z.9
Timaran, C.H.10
-
18
-
-
0348161424
-
Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: Interobserver variability of various measurement protocols and its clinical relevance
-
DOI 10.1007/s00330-003-1914-8
-
H.T. Abada, M.R. Sapoval, and J.F. Paul Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: interobserver variability of various measurement protocols and its clinical relevance Eur Radiol 13 12 2003 2699 2704 (Pubitemid 37527076)
-
(2003)
European Radiology
, vol.13
, Issue.12
, pp. 2699-2704
-
-
Abada, H.T.1
Sapoval, M.R.2
Paul, J.-F.3
De Maertelaer, V.4
Mousseaux, E.5
Gaux, J.-L.6
-
19
-
-
0141702273
-
Two-dimensional versus three-dimensional CT scan for aortic measurement
-
DOI 10.1583/1545-1550(2003)010<0531:TVTCSF>2.0.CO;2
-
E.D. Dillavou, D.G. Buck, and S.C. Muluk Two-dimensional versus three-dimensional CT scan for aortic measurement J Endovasc Ther 10 3 2003 531 538 (Pubitemid 37129214)
-
(2003)
Journal of Endovascular Therapy
, vol.10
, Issue.3
, pp. 531-538
-
-
Dillavou, E.D.1
Buck, D.G.2
Muluk, S.C.3
Makaroun, M.S.4
|