메뉴 건너뛰기




Volumn 51, Issue 4, 2010, Pages 821-828

Validation of a new standardized method to measure proximal aneurysm neck angulation

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ADULT; AGED; AORTA NECK ANGLE MEASUREMENT; AORTA RECONSTRUCTION; ARTICLE; CLINICAL ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; ENDOVASCULAR SURGERY; FEMALE; HUMAN; IMAGE RECONSTRUCTION; MALE; MEASUREMENT; OBSERVER VARIATION; PRIORITY JOURNAL; STANDARDIZATION; VALIDATION STUDY;

EID: 77949897451     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvs.2009.10.114     Document Type: Article
Times cited : (89)

References (15)
  • 1
    • 5344261145 scopus 로고    scopus 로고
    • A randomized trial comparing conventional and endovascular repair of abdominal aortic aneurysms
    • Prinssen M., Verhoeven E.L., Buth J., Cuypers P.W., van Sambeek M.R., Balm R., et al. A randomized trial comparing conventional and endovascular repair of abdominal aortic aneurysms. N Engl J Med 351 (2004) 1607-1618
    • (2004) N Engl J Med , vol.351 , pp. 1607-1618
    • Prinssen, M.1    Verhoeven, E.L.2    Buth, J.3    Cuypers, P.W.4    van Sambeek, M.R.5    Balm, R.6
  • 2
    • 0034164052 scopus 로고    scopus 로고
    • Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms
    • Albertini J., Kalliafas S., Travis S., Yusuf S.W., Macierewicz J.A., Whitaker S.C., et al. Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms. Eur J Vasc Endovasc Surg 19 (2000) 308-312
    • (2000) Eur J Vasc Endovasc Surg , vol.19 , pp. 308-312
    • Albertini, J.1    Kalliafas, S.2    Travis, S.3    Yusuf, S.W.4    Macierewicz, J.A.5    Whitaker, S.C.6
  • 3
    • 30544448633 scopus 로고    scopus 로고
    • Predictors of success following endovascular aneurysm repair: mid-term results
    • Audit Reference Group
    • Boult M., Babidge W., Maddern G., Barnes M., Fitridge R., and Audit Reference Group. Predictors of success following endovascular aneurysm repair: mid-term results. Eur J Vasc Endovasc Surg 31 (2006) 123-129
    • (2006) Eur J Vasc Endovasc Surg , vol.31 , pp. 123-129
    • Boult, M.1    Babidge, W.2    Maddern, G.3    Barnes, M.4    Fitridge, R.5
  • 4
    • 33745638740 scopus 로고    scopus 로고
    • Dynamic magnetic resonance angiography of the aneurysm neck: conformational changes during the cardiac cycle with possible consequences for endograft sizing and future design
    • van Herwaarden J.A., Bartels L.W., Muhs B.E., Vincken K.L., Lindeboom M.Y., Teutelink A., et al. Dynamic magnetic resonance angiography of the aneurysm neck: conformational changes during the cardiac cycle with possible consequences for endograft sizing and future design. J Vasc Surg 44 (2006) 22-28
    • (2006) J Vasc Surg , vol.44 , pp. 22-28
    • van Herwaarden, J.A.1    Bartels, L.W.2    Muhs, B.E.3    Vincken, K.L.4    Lindeboom, M.Y.5    Teutelink, A.6
  • 6
  • 7
    • 0034911651 scopus 로고    scopus 로고
    • Intraoperative proximal endoleaks during AAA stent-graft repair: evaluation of risk factors and treatment with Palmaz stents
    • Dias N.V., Resch T., Malina M., Lindblad B., and Ivancev K. Intraoperative proximal endoleaks during AAA stent-graft repair: evaluation of risk factors and treatment with Palmaz stents. J Endovasc Ther 8 (2001) 268-273
    • (2001) J Endovasc Ther , vol.8 , pp. 268-273
    • Dias, N.V.1    Resch, T.2    Malina, M.3    Lindblad, B.4    Ivancev, K.5
  • 8
    • 33847176605 scopus 로고    scopus 로고
    • Influence of severe infrarenal aortic neck angulation on complications at the proximal neck following endovascular AAA repair: a EUROSTAR study
    • Hobo R., Kievit J., Leurs L.J., and Buth J. Influence of severe infrarenal aortic neck angulation on complications at the proximal neck following endovascular AAA repair: a EUROSTAR study. J Endovasc Ther 14 (2007) 1-11
    • (2007) J Endovasc Ther , vol.14 , pp. 1-11
    • Hobo, R.1    Kievit, J.2    Leurs, L.J.3    Buth, J.4
  • 9
    • 0036518028 scopus 로고    scopus 로고
    • Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair
    • Sternbergh III W.C., Carter G., York J.W., Yoselevitz M., and Money S.R. Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair. J Vasc Surg 35 (2002) 482-486
    • (2002) J Vasc Surg , vol.35 , pp. 482-486
    • Sternbergh III, W.C.1    Carter, G.2    York, J.W.3    Yoselevitz, M.4    Money, S.R.5
  • 11
    • 49749101185 scopus 로고    scopus 로고
    • Sixty-four-detector CT angiography of infrarenal aortic neck length and angulation: prospective analysis of interobserver variability
    • Diehm N., Katzen B.T., Samuels S., Pena C., Powell A., and Dick F. Sixty-four-detector CT angiography of infrarenal aortic neck length and angulation: prospective analysis of interobserver variability. J Vasc Interv Radiol 19 (2008) 1283-1288
    • (2008) J Vasc Interv Radiol , vol.19 , pp. 1283-1288
    • Diehm, N.1    Katzen, B.T.2    Samuels, S.3    Pena, C.4    Powell, A.5    Dick, F.6
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 0041884957 scopus 로고    scopus 로고
    • Aortoiliac morphologic correlations in aneurysms undergoing endovascular repair
    • Ouriel K., Tanquilut E., Greenberg R.K., and Walker E. Aortoiliac morphologic correlations in aneurysms undergoing endovascular repair. J Vasc Surg 38 (2003) 323-328
    • (2003) J Vasc Surg , vol.38 , pp. 323-328
    • Ouriel, K.1    Tanquilut, E.2    Greenberg, R.K.3    Walker, E.4
  • 15
    • 70350170546 scopus 로고    scopus 로고
    • Potential value of aneurysm sac volume measurements in addition to diameter measurements after endovascular aneurysm repair
    • van Keulen J.W., van Prehn J., Prokop M., Moll F.L., and van Herwaarden J.A. Potential value of aneurysm sac volume measurements in addition to diameter measurements after endovascular aneurysm repair. J Endovasc Ther 16 (2009) 506-513
    • (2009) J Endovasc Ther , vol.16 , pp. 506-513
    • van Keulen, J.W.1    van Prehn, J.2    Prokop, M.3    Moll, F.L.4    van Herwaarden, J.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.