메뉴 건너뛰기




Volumn 544, Issue , 2012, Pages 10-16

A chip calorimeter for the monitoring of conventional bioreactors at elevated cell concentrations

Author keywords

Bioreactor; Chip calorimetry; Metabolic heat

Indexed keywords

BATCH FERMENTATION; CELL CONCENTRATIONS; CHIP CALORIMETER; METABOLIC HEAT; POWER INPUT; SAMPLE DILUTION; UPPER LIMITS;

EID: 84864425824     PISSN: 00406031     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.tca.2012.06.004     Document Type: Article
Times cited : (4)

References (27)
  • 1
    • 0032766128 scopus 로고    scopus 로고
    • Does microbial life always feed on negative entropy? Thermodynamic analysis of microbial growth
    • U. von Stockar, and J.S. Liu Does microbial life always feed on negative entropy? Thermodynamic analysis of microbial growth Biochim. Biophys. Acta 1412 1999 191 211
    • (1999) Biochim. Biophys. Acta , vol.1412 , pp. 191-211
    • Von Stockar, U.1    Liu, J.S.2
  • 2
    • 0003123020 scopus 로고    scopus 로고
    • La vie est donc un feu pour la calorimetrie: Half a century of calorimetry - Ingemar Wadsö at 70
    • R.B. Kemp, and I. Lamprecht La vie est donc un feu pour la calorimetrie: half a century of calorimetry - Ingemar Wadsö at 70 Thermochim. Acta 348 2000 1 17
    • (2000) Thermochim. Acta , vol.348 , pp. 1-17
    • Kemp, R.B.1    Lamprecht, I.2
  • 3
    • 0041041170 scopus 로고
    • Studies of enthalpy balance and adenosine triphosphate turnover in cultured animal cells
    • R.B. Kemp Studies of enthalpy balance and adenosine triphosphate turnover in cultured animal cells Pure Appl. Chem. 66 1994 479 484
    • (1994) Pure Appl. Chem. , vol.66 , pp. 479-484
    • Kemp, R.B.1
  • 4
    • 0000991952 scopus 로고
    • The relation of oxygen to the heat of combustion of organic compounds
    • W. Thornton The relation of oxygen to the heat of combustion of organic compounds Philos. Mag. 33 1917 196 203
    • (1917) Philos. Mag. , vol.33 , pp. 196-203
    • Thornton, W.1
  • 5
    • 0025320078 scopus 로고
    • Anaerobic metabolism in aerobic mammalian cells: Information from the ratio of calorimetric heat flux and respirometric oxygen flux
    • E. Gnaiger, and R.B. Kemp Anaerobic metabolism in aerobic mammalian cells: information from the ratio of calorimetric heat flux and respirometric oxygen flux Biochim. Biophys. Acta 1016 1990 328 332
    • (1990) Biochim. Biophys. Acta , vol.1016 , pp. 328-332
    • Gnaiger, E.1    Kemp, R.B.2
  • 6
    • 0035910669 scopus 로고    scopus 로고
    • The calorimetric-respirometric ratio is an on-line marker of enthalpy efficiency of yeast cells growing on a non-fermentable carbon source
    • L. Dejean, B. Beauvoit, O. Bunoust, C. Fleury, B. Guerin, and M. Rigoulet The calorimetric-respirometric ratio is an on-line marker of enthalpy efficiency of yeast cells growing on a non-fermentable carbon source Biochim. Biophys. Acta: Bioenerg. 1503 2001 329 340
    • (2001) Biochim. Biophys. Acta: Bioenerg. , vol.1503 , pp. 329-340
    • Dejean, L.1    Beauvoit, B.2    Bunoust, O.3    Fleury, C.4    Guerin, B.5    Rigoulet, M.6
  • 7
    • 0034738358 scopus 로고    scopus 로고
    • Fire burn and cauldron bubble (W. Shakespeare): What the calorimetric-respirometric (CR) ratio does for our understanding of cells?
    • R.B. Kemp Fire burn and cauldron bubble (W. Shakespeare): what the calorimetric-respirometric (CR) ratio does for our understanding of cells? Thermochim. Acta 355 2000 115 124
    • (2000) Thermochim. Acta , vol.355 , pp. 115-124
    • Kemp, R.B.1
  • 8
    • 8644230857 scopus 로고    scopus 로고
    • Development of biocalorimetry as a technique for process monitoring and control in technical scale fermentations
    • M. Tuerker Development of biocalorimetry as a technique for process monitoring and control in technical scale fermentations Thermochim. Acta 419 2000 73 81
    • (2000) Thermochim. Acta , vol.419 , pp. 73-81
    • Tuerker, M.1
  • 9
    • 0000799121 scopus 로고
    • Large-scale calorimetry and biotechnology
    • U. von Stockar, and I.W. Marison Large-scale calorimetry and biotechnology Thermochim. Acta 193 1991 215 242
    • (1991) Thermochim. Acta , vol.193 , pp. 215-242
    • Von Stockar, U.1    Marison, I.W.2
  • 10
    • 41149124506 scopus 로고    scopus 로고
    • A small-scale calorimetric reactor system combined with several chemical sensors for the investigation of microbial growth processes
    • R. Huettl, J. Harmel, A. Lissner, G. Wolf, P. Klare, W. Vonau, F. Berthold, and S. Herrmann A small-scale calorimetric reactor system combined with several chemical sensors for the investigation of microbial growth processes Eng. Life Sci. 8 2008 56 61
    • (2008) Eng. Life Sci. , vol.8 , pp. 56-61
    • Huettl, R.1    Harmel, J.2    Lissner, A.3    Wolf, G.4    Klare, P.5    Vonau, W.6    Berthold, F.7    Herrmann, S.8
  • 11
    • 0003166310 scopus 로고    scopus 로고
    • Probing the metabolism of genetically-engineered mammalian cells by heat flux
    • R.B. Kemp, and Y. Guan Probing the metabolism of genetically-engineered mammalian cells by heat flux Thermochim. Acta 309 1998 63 78
    • (1998) Thermochim. Acta , vol.309 , pp. 63-78
    • Kemp, R.B.1    Guan, Y.2
  • 12
    • 84914887587 scopus 로고
    • Calorimeter-fermentor combination for investigations on microbial steady state cultures
    • H.P. Leiseifer, and G.H. Schleser Calorimeter-fermentor combination for investigations on microbial steady state cultures Z. Naturforsch. 38c 1983 259 267
    • (1983) Z. Naturforsch. , vol.38 C , pp. 259-267
    • Leiseifer, H.P.1    Schleser, G.H.2
  • 15
    • 41449105031 scopus 로고    scopus 로고
    • Chip calorimetry and its use for biochemical and cell biological investigations
    • J. Lerchner, T. Maskow, and G. Wolf Chip calorimetry and its use for biochemical and cell biological investigations Chem. Eng. Process. 47 2008 991 999
    • (2008) Chem. Eng. Process. , vol.47 , pp. 991-999
    • Lerchner, J.1    Maskow, T.2    Wolf, G.3
  • 16
    • 33744974064 scopus 로고    scopus 로고
    • Chip calorimeters for the investigation of liquid phase reactions: Design rules
    • J. Lerchner, A. Wolf, G. Wolf, and I. Fernandez Chip calorimeters for the investigation of liquid phase reactions: design rules Thermochim. Acta 446 2006 168 175
    • (2006) Thermochim. Acta , vol.446 , pp. 168-175
    • Lerchner, J.1    Wolf, A.2    Wolf, G.3    Fernandez, I.4
  • 17
    • 33645366995 scopus 로고    scopus 로고
    • Chip calorimetry for the monitoring of whole cell biotransformation
    • T. Maskow, J. Lerchner, M. Peitzsch, H. Harms, and G. Wolf Chip calorimetry for the monitoring of whole cell biotransformation J. Biotechnol. 122 2006 431 442
    • (2006) J. Biotechnol. , vol.122 , pp. 431-442
    • Maskow, T.1    Lerchner, J.2    Peitzsch, M.3    Harms, H.4    Wolf, G.5
  • 18
    • 33646082049 scopus 로고    scopus 로고
    • Replacement of the glucose phosphotransferase transport system by galactose permease reduces acetate accumulation and improves process performance of Escherichia coli for recombinant protein production without impairment of growth rate
    • R. de Anda, A.R. Lara, V. Hernandez, V. Hernandez-Montalvo, G. Gosset, F. Bolivar, and O.T. Ramirez Replacement of the glucose phosphotransferase transport system by galactose permease reduces acetate accumulation and improves process performance of Escherichia coli for recombinant protein production without impairment of growth rate Metab. Eng. 8 2006 281 290
    • (2006) Metab. Eng. , vol.8 , pp. 281-290
    • De Anda, R.1    Lara, A.R.2    Hernandez, V.3    Hernandez-Montalvo, V.4    Gosset, G.5    Bolivar, F.6    Ramirez, O.T.7
  • 19
    • 77957336872 scopus 로고    scopus 로고
    • High cell-density processes in batch mode of a genetically engineered Escherichia coli strain with minimized overflow metabolism using a pressurized bioreactor
    • I. Knabben, L. Regestein, F. Marquering, S. Steinbusch, A.R. Lara, and J. Büchs High cell-density processes in batch mode of a genetically engineered Escherichia coli strain with minimized overflow metabolism using a pressurized bioreactor J. Biotechnol. 150 2010 73 79
    • (2010) J. Biotechnol. , vol.150 , pp. 73-79
    • Knabben, I.1    Regestein, L.2    Marquering, F.3    Steinbusch, S.4    Lara, A.R.5    Büchs, J.6
  • 22
    • 24944545103 scopus 로고    scopus 로고
    • Highly sensitive thermopile heat power sensor for micro-fluid calorimetry of biochemical processes
    • V. Baier, R. Foedisch, A. Ihring, E. Kessler, J. Lerchner, and G. Wolf Highly sensitive thermopile heat power sensor for micro-fluid calorimetry of biochemical processes Sens. Actuators A123-A124 2005 354 359
    • (2005) Sens. Actuators , vol.A123-A124 , pp. 354-359
    • Baier, V.1    Foedisch, R.2    Ihring, A.3    Kessler, E.4    Lerchner, J.5    Wolf, G.6
  • 23
    • 17144397579 scopus 로고    scopus 로고
    • The oxygen mass transfer, carbon dioxide inhibition, heat removal, and the energy and cost efficiencies of high pressure fermentation
    • A. Knoll, B. Maier, H. Tscherrig, and J. Büchs The oxygen mass transfer, carbon dioxide inhibition, heat removal, and the energy and cost efficiencies of high pressure fermentation Adv. Biochem. Eng. Biotechnol. 92 2005 77 99
    • (2005) Adv. Biochem. Eng. Biotechnol. , vol.92 , pp. 77-99
    • Knoll, A.1    Maier, B.2    Tscherrig, H.3    Büchs, J.4
  • 25
    • 84864461687 scopus 로고    scopus 로고
    • http://water.usgs.gov/owq/FieldManual/
  • 26
    • 77249162122 scopus 로고    scopus 로고
    • Calorimetric control for high cell density cultivation of a recombinant Escherichia coli strain
    • R. Biener, A. Steinkämpfer, and J. Hofmann Calorimetric control for high cell density cultivation of a recombinant Escherichia coli strain J. Biotechnol. 146 2010 45 53
    • (2010) J. Biotechnol. , vol.146 , pp. 45-53
    • Biener, R.1    Steinkämpfer, A.2    Hofmann, J.3
  • 27
    • 5644245248 scopus 로고    scopus 로고
    • Progress curve analysis for enzyme and microbial kinetic reactions using explicit solutions based on Lambert W function
    • C.T. Goudar, S.K. Harris, M.J. McInerney, and J.M. Suflita Progress curve analysis for enzyme and microbial kinetic reactions using explicit solutions based on Lambert W function J. Microbiol. Methods 59 2004 317 326
    • (2004) J. Microbiol. Methods , vol.59 , pp. 317-326
    • Goudar, C.T.1    Harris, S.K.2    McInerney, M.J.3    Suflita, J.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.