메뉴 건너뛰기




Volumn 33, Issue 9, 2008, Pages 960-965

Salvage of C2 pedicle and pars screws using the intralaminar technique: A biomechanical analysis

Author keywords

Ankylosing spondylitis; Catastrophizing; Chronic pain; Diagnosis; Disability; Low back pain; Pain beliefs

Indexed keywords

ARTICLE; BONE DENSITY; CADAVER; CERVICAL SPINE; CORRELATION COEFFICIENT; DUAL ENERGY X RAY ABSORPTIOMETRY; HUMAN; HUMAN TISSUE; INTRALAMINAR TECHNIQUE; LAMINAR SCREW; LINEAR REGRESSION ANALYSIS; PARS SCREW; PEDICLE SCREW; PRIORITY JOURNAL; SPINE SURGERY; STATISTICAL SIGNIFICANCE; SURGEON; SURGICAL EQUIPMENT; BONE SCREW; COMPARATIVE STUDY; DEVICE REMOVAL; EQUIPMENT; EQUIPMENT DESIGN; INSTRUMENTATION; MATERIALS TESTING; ORTHOPEDIC SURGERY; RADIOGRAPHY; REOPERATION; REPRODUCIBILITY; SALVAGE THERAPY; TENSILE STRENGTH; TORQUE;

EID: 42449138374     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e31816c915b     Document Type: Article
Times cited : (102)

References (16)
  • 1
    • 0030973318 scopus 로고    scopus 로고
    • Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique
    • Madawi AA, Casey AT, Solanki GA, et al. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 1997;86:961-8.
    • (1997) J Neurosurg , vol.86 , pp. 961-968
    • Madawi, A.A.1    Casey, A.T.2    Solanki, G.A.3
  • 2
    • 1842332093 scopus 로고    scopus 로고
    • Variation of the groove in the axis vertebra for the vertebral artery: Implication for instrumentation
    • Abou MA, Solanki G, Caset AT, et al. Variation of the groove in the axis vertebra for the vertebral artery: implication for instrumentation. J Bone Joint Surg Br 1997;79:820-3.
    • (1997) J Bone Joint Surg Br , vol.79 , pp. 820-823
    • Abou, M.A.1    Solanki, G.2    Caset, A.T.3
  • 3
    • 0032143648 scopus 로고    scopus 로고
    • Anatomic study for ideal and safe posterior C1-2 transarticular screw fixation
    • Jun BY. Anatomic study for ideal and safe posterior C1-2 transarticular screw fixation. Spine 1998;23:1703-7.
    • (1998) Spine , vol.23 , pp. 1703-1707
    • Jun, B.Y.1
  • 4
    • 0029773340 scopus 로고    scopus 로고
    • The anatomical suitability of the C1-2 complex for transarticular screw fixation
    • Paramore CG, Dickman CA, Sonntag VK. The anatomical suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg 1996;85:221-4.
    • (1996) J Neurosurg , vol.85 , pp. 221-224
    • Paramore, C.G.1    Dickman, C.A.2    Sonntag, V.K.3
  • 5
    • 0011948449 scopus 로고
    • Fractures and dislocations of the cervical spine
    • Gallie WE. Fractures and dislocations of the cervical spine. Am J Surg 1939;46:495-9.
    • (1939) Am J Surg , vol.46 , pp. 495-499
    • Gallie, W.E.1
  • 6
    • 0017871668 scopus 로고
    • Atlanto-axial arthrodesis by the wedge compression method
    • Brooks AL, Jenkins EB. Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am 1978;60:279-84.
    • (1978) J Bone Joint Surg Am , vol.60 , pp. 279-284
    • Brooks, A.L.1    Jenkins, E.B.2
  • 7
    • 0032985799 scopus 로고    scopus 로고
    • Modified Gallie technique versus transarticular screw fixation in C1-C2 fusion
    • Farey I, Nadkarni S, Smith N. Modified Gallie technique versus transarticular screw fixation in C1-C2 fusion. Clin Orthop 1999;359:126-35.
    • (1999) Clin Orthop , vol.359 , pp. 126-135
    • Farey, I.1    Nadkarni, S.2    Smith, N.3
  • 8
    • 1842686189 scopus 로고    scopus 로고
    • Posterior C2 fixation using bilateral, crossing C2 laminar screws: Case series and technical note
    • Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 2004;17:158-62.
    • (2004) J Spinal Disord Tech , vol.17 , pp. 158-162
    • Wright, N.M.1
  • 9
    • 32944464250 scopus 로고    scopus 로고
    • Translaminar rigid screw fixation of the axis. Technical note
    • Wright NM. Translaminar rigid screw fixation of the axis. Technical note. J Neurosurg Spine 2005;3:409-14.
    • (2005) J Neurosurg Spine , vol.3 , pp. 409-414
    • Wright, N.M.1
  • 10
    • 22144451090 scopus 로고    scopus 로고
    • Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation
    • Gorek J, Acaroglu E, Berven S, et al. Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation. Spine 2005;30:1513-8.
    • (2005) Spine , vol.30 , pp. 1513-1518
    • Gorek, J.1    Acaroglu, E.2    Berven, S.3
  • 11
    • 0035890208 scopus 로고    scopus 로고
    • Posterior C1-C2 fusion with polyaxial screw and rod fixation
    • Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine 2001;26:2467-71.
    • (2001) Spine , vol.26 , pp. 2467-2471
    • Harms, J.1    Melcher, R.P.2
  • 12
    • 1542378014 scopus 로고    scopus 로고
    • Biomechanical comparison of anterior and posterior stabilization methods in atlantoaxial instability
    • Kim SM, Lim TJ, Paterno J, et al. Biomechanical comparison of anterior and posterior stabilization methods in atlantoaxial instability. J Neurosurg (Spine 3) 2004;100:277-83.
    • (2004) J Neurosurg (Spine 3) , vol.100 , pp. 277-283
    • Kim, S.M.1    Lim, T.J.2    Paterno, J.3
  • 13
    • 13444291294 scopus 로고    scopus 로고
    • Kuroki H, Rengachary SS, Goel VK, et al. Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation. Neurosurgery 2005;56 (ONS suppl 1):ONS 151-9.
    • Kuroki H, Rengachary SS, Goel VK, et al. Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation. Neurosurgery 2005;56 (ONS suppl 1):ONS 151-9.
  • 14
    • 0037112085 scopus 로고    scopus 로고
    • Biomechanical testing of posterior atlantoaxial fixation techniques
    • Melcher RP, Puttlitz CM, Kleinstueck FS, et al. Biomechanical testing of posterior atlantoaxial fixation techniques. Spine 2002;27:2435-40.
    • (2002) Spine , vol.27 , pp. 2435-2440
    • Melcher, R.P.1    Puttlitz, C.M.2    Kleinstueck, F.S.3
  • 15
    • 0029869526 scopus 로고    scopus 로고
    • Anatomic consideration of C-2 PS placement
    • Ebraheim N, Rollins JR, Xu R, et al. Anatomic consideration of C-2 PS placement. Spine 1996;21:691-5.
    • (1996) Spine , vol.21 , pp. 691-695
    • Ebraheim, N.1    Rollins, J.R.2    Xu, R.3
  • 16
    • 33745792102 scopus 로고    scopus 로고
    • Biomechanical comparison of four C1 to C2 rigid fixative techniques: Anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws
    • Lapsiwala SB, Anderson PA, Oza A, et al. Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 2006;58:516-21.
    • (2006) Neurosurgery , vol.58 , pp. 516-521
    • Lapsiwala, S.B.1    Anderson, P.A.2    Oza, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.