메뉴 건너뛰기




Volumn 57, Issue 6, 2012, Pages 1719-1723

Safety of capsule endoscopy using human body communication in patients with cardiac devices

Author keywords

Capsule endoscopy; Cardiac pacemaker; Human body communication; Implantable cardiac defibrillator

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; BODY REGIONS; CAPSULE ENDOSCOPY; CARDIOLOGIST; CARDIOVASCULAR EQUIPMENT; CARDIOVERSION; CLINICAL ARTICLE; DEFIBRILLATION; DEFIBRILLATOR; DEVICES; ELECTRIC FIELD; ELECTROCARDIOGRAM; ELECTROCARDIOGRAPHY MONITORING; ENDOSCOPE; FEMALE; HEART RHYTHM; HUMAN; HUMAN BODY COMMUNICATION; IMPLANT; MALE; PATIENT SAFETY; PRIORITY JOURNAL; TELEMETRY;

EID: 84864278677     PISSN: 01632116     EISSN: 15732568     Source Type: Journal    
DOI: 10.1007/s10620-012-2067-x     Document Type: Article
Times cited : (17)

References (24)
  • 1
    • 36849022671 scopus 로고    scopus 로고
    • Capsule endoscopy
    • DOI 10.1055/s-2007-966925
    • Saurin JC. Capsule endoscopy. Endoscopy. 2007;39:986-991. doi:10.1055/s-2007-966925. (Pubitemid 350226945)
    • (2007) Endoscopy , vol.39 , Issue.11 , pp. 986-991
    • Saurin, J.-C.1
  • 2
    • 37249069496 scopus 로고    scopus 로고
    • Risks of capsule endoscopy
    • DOI 10.1016/j.tgie.2007.08.017, PII S1096288307000514, Volume 2. Risks of Endoscopy and the Endoscopist, the Endoscopy Staff, and the Patient
    • Schnoll-Sussman F, Kulkarni K. Risks of capsule endoscopy. Tech Gastrointest Endosc. 2008;10:25-30. (Pubitemid 350263709)
    • (2008) Techniques in Gastrointestinal Endoscopy , vol.10 , Issue.1 , pp. 25-30
    • Schnoll-Sussman, F.1    Kulkarni, K.2
  • 3
    • 33646085506 scopus 로고    scopus 로고
    • Contraindications to capsule endoscopy: Do any still exist?
    • doi:10.1016/j.giec.2006.01.017
    • Storch I, Barkin JS. Contraindications to capsule endoscopy: do any still exist? Gastrointest Endosc Clin N Am. 2006;16:329-336. doi:10.1016/j.giec.2006. 01.017.
    • (2006) Gastrointest Endosc Clin N Am. , vol.16 , pp. 329-336
    • Storch, I.1    Barkin, J.S.2
  • 4
    • 37348999169 scopus 로고    scopus 로고
    • Effects of electromagnetic interference on implanted cardiac devices and their management
    • DOI 10.1097/CRD.0b013e31813e0ba9, PII 0004541520071100000007
    • Yerra L, Reddy PC. Effects of electromagnetic interference on implanted cardiac devices and their management. Cardiol Rev. 2007;15:304-309. doi:10.1097/CRD.0b013e31813e0ba9. (Pubitemid 350307639)
    • (2007) Cardiology in Review , vol.15 , Issue.6 , pp. 304-309
    • Yerra, L.1    Reddy, P.C.2
  • 5
    • 7444248559 scopus 로고    scopus 로고
    • Electromagnetic interference in cardiac rhythm management devices
    • Sweesy MW, Holland JL, Smith KW. Electromagnetic interference in cardiac rhythm management devices. AACN Clin Issues. 2004;15:391-403.
    • (2004) AACN Clin Issues , vol.15 , pp. 391-403
    • Sweesy, M.W.1    Holland, J.L.2    Smith, K.W.3
  • 6
    • 0032487943 scopus 로고    scopus 로고
    • Interference with an implantable defibrillator by an electronic antitheft-surveillance device
    • DOI 10.1056/NEJM199811053391905
    • Santucci PA, Haw J, Trohman RG, et al. Interference with an implantable defibrillator by an electronic antitheft-surveillance device. N Engl J Med. 1998;339:1371-1374. doi:10.1056/NEJM 199811053391905. (Pubitemid 28509347)
    • (1998) New England Journal of Medicine , vol.339 , Issue.19 , pp. 1371-1374
    • Santucci, P.A.1    Haw, J.2    Trohman, R.G.3    Pinski, S.L.4
  • 10
    • 40849146977 scopus 로고    scopus 로고
    • Electromagnetic interference with pacemakers caused by portable media players
    • doi:10.1016/j.hrthm.2008.01.028
    • Thaker JP, Patel MB, Jongnarangsin K, et al. Electromagnetic interference with pacemakers caused by portable media players. Heart Rhythm. 2008;5:538-544. doi:10.1016/j.hrthm.2008.01.028.
    • (2008) Heart Rhythm. , vol.5 , pp. 538-544
    • Thaker, J.P.1    Patel, M.B.2    Jongnarangsin, K.3    Et Al.4
  • 14
    • 24144447825 scopus 로고    scopus 로고
    • Kapselendoskopie bei herzschrittmacher-patienten: Aktueller stand in Deutschland
    • DOI 10.1055/s-2005-858469
    • Bandorski D, Diehl KL, Jaspersen D. Capsule endoscopy in patients with cardiac pacemakers: current situation in Germany. Z Gastroenterol. 2005;43:715-718. doi:10.1055/s-2005-858469. (Pubitemid 41233458)
    • (2005) Zeitschrift fur Gastroenterologie , vol.43 , Issue.8 , pp. 715-718
    • Bandorski, D.1    Diehl, K.-L.2    Jaspersen, D.3
  • 15
    • 79953650543 scopus 로고    scopus 로고
    • Capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter-defibrillators - A retrospective multicenter investigation
    • Bandorski D, Lotterer E, Hartmann D, et al. Capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter-defibrillators - a retrospective multicenter investigation. J Gastrointest Liver Dis. 2011;20:33-37.
    • (2011) J Gastrointest Liver Dis. , vol.20 , pp. 33-37
    • Bandorski, D.1    Lotterer, E.2    Hartmann, D.3    Et Al.4
  • 17
    • 34247100691 scopus 로고    scopus 로고
    • Electromagnetic interference from wireless video-capsule endoscopy on implantable cardioverter-defibrillators
    • DOI 10.1111/j.1540-8159.2007.00695.x
    • Dubner S, Dubner Y, Rubio H, et al. Electromagnetic interference from wireless video-capsule endoscopy on implantable cardioverter-defibrillators. Pacing Clin Electrophysiol. 2007;30:472-475. doi:10.1111/j.1540-8159.2007.00695. x. (Pubitemid 46596122)
    • (2007) PACE - Pacing and Clinical Electrophysiology , vol.30 , Issue.4 , pp. 472-475
    • Dubner, S.1    Dubner, Y.2    Rubio, H.3    Goldin, E.4
  • 18
    • 38849109342 scopus 로고    scopus 로고
    • Capsule endoscopy and pacemakers: Investigation for possible interference
    • DOI 10.1055/s-2007-995353
    • Bandorski D, Irnich W, Bruck M, et al. Capsule endoscopy and cardiac pacemakers: investigation for possible interference. Endoscopy. 2008;40:36-39. doi:10.1055/s-2007-995353. (Pubitemid 351201541)
    • (2008) Endoscopy , vol.40 , Issue.1 , pp. 36-39
    • Bandorski, D.1    Irnich, W.2    Bruck, M.3    Beyer, N.4    Kramer, W.5    Jakobs, R.6
  • 19
    • 67849114553 scopus 로고    scopus 로고
    • Do endoscopy capsules interfere with implantable cardioverter- defibrillators?
    • doi:10.1055/s-0029-1214610
    • Bandorski D, Irnich W, Bruck M, et al. Do endoscopy capsules interfere with implantable cardioverter-defibrillators? Endoscopy. 2009;41:457-461. doi:10.1055/s-0029-1214610.
    • (2009) Endoscopy , vol.41 , pp. 457-461
    • Bandorski, D.1    Irnich, W.2    Bruck, M.3    Et Al.4
  • 20
    • 58649097129 scopus 로고    scopus 로고
    • First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: Electric-field propagation
    • doi:10.1016/j.gie.2008.04.033
    • Bang S, Park JY, Jeong S, et al. First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: electric-field propagation. Gastrointest Endosc. 2009;69:253-259. doi:10.1016/j.gie.2008.04.033.
    • (2009) Gastrointest Endosc. , vol.69 , pp. 253-259
    • Bang, S.1    Park, J.Y.2    Jeong, S.3    Et Al.4
  • 22
    • 38849173041 scopus 로고    scopus 로고
    • Successful videocapsule endoscopy in patients with an abdominal cardiac pacemaker
    • DOI 10.1055/s-2007-966785
    • Dirks MH, Costea F, Seidman EG. Successful videocapsule endoscopy in patients with an abdominal cardiac pacemaker. Endoscopy. 2008;40:73-75. doi:10.1055/s-2007-966785. (Pubitemid 351201549)
    • (2008) Endoscopy , vol.40 , Issue.1 , pp. 73-75
    • Dirks, M.H.1    Costea, F.2    Seidman, E.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.