메뉴 건너뛰기




Volumn 36, Issue 2, 2012, Pages 411-421

Correction of arterial input function in dynamic contrast-enhanced MRI of the liver

Author keywords

AIF saturation; correction; DCE MRI; dual input single compartment model; liver

Indexed keywords

ARTERIAL INPUT FUNCTION; ARTERIAL OXYGEN SATURATION; ARTERY PERFUSION; ARTICLE; BLOOD VESSEL PARAMETERS; CLINICAL ARTICLE; CONTRAST TO NOISE RATIO; DYNAMIC CONTRAST ENHACED MAGNETIC RESONANCE IMAGING; HUMAN; LIVER CANCER; LIVER FUNCTION TEST; LIVER PERFUSION; NUCLEAR MAGNETIC RESONANCE IMAGING; ORGAN PERFUSION; PARAMETERS; PORTAL VENOUS PERFUSION; PRIORITY JOURNAL; SENSITIVITY ANALYSIS;

EID: 84864256843     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.23636     Document Type: Article
Times cited : (30)

References (38)
  • 2
    • 0035115565 scopus 로고    scopus 로고
    • Hepatic perfusion parameters in chronic liver disease: Dynamic CT measurements correlated with disease severity
    • Van Beers BE, Leconte I, Materne R, Smith AM, Jamart J, Horsmans Y,. Hepatic perfusion parameters in chronic liver disease: dynamic CT measurements correlated with disease severity. AJR Am J Roentgenol 2001; 176: 667-673. (Pubitemid 32181963)
    • (2001) American Journal of Roentgenology , vol.176 , Issue.3 , pp. 667-673
    • Van Beers, B.E.1    Leconte, I.2    Materne, R.3    Smith, A.M.4    Jamart, J.5    Horsmans, Y.6
  • 3
    • 53749098967 scopus 로고    scopus 로고
    • A quantitative method for estimating hepatic blood flow using a dual-input single-compartment model
    • Miyazaki S, Murase K, Yoshikawa T, Morimoto S, Ohno Y, Sugimura K,. A quantitative method for estimating hepatic blood flow using a dual-input single-compartment model. Br J Radiol 2008; 81: 790-800.
    • (2008) Br J Radiol , vol.81 , pp. 790-800
    • Miyazaki, S.1    Murase, K.2    Yoshikawa, T.3    Morimoto, S.4    Ohno, Y.5    Sugimura, K.6
  • 5
    • 0033782203 scopus 로고    scopus 로고
    • Determination of the MRI contrast agent concentration time course in vivo following bolus injection: Effect of equilibrium transcytolemmal water exchange
    • Landis CS, Li X, Telang FW, et al. Determination of the MRI contrast agent concentration time course in vivo following bolus injection: effect of equilibrium transcytolemmal water exchange. Magn Reson Med 2000; 44: 563-574.
    • (2000) Magn Reson Med , vol.44 , pp. 563-574
    • Landis, C.S.1    Li, X.2    Telang, F.W.3
  • 7
    • 0033766487 scopus 로고    scopus 로고
    • Gd-DTPA relaxivity depends on macromolecular content
    • Stanisz GJ, Henkelman RM,. Gd-DTPA relaxivity depends on macromolecular content. Magn Reson Med 2000; 44: 665-667.
    • (2000) Magn Reson Med , vol.44 , pp. 665-667
    • Stanisz, G.J.1    Henkelman, R.M.2
  • 9
    • 33746911116 scopus 로고    scopus 로고
    • Combined T2*and T1 measurements for improved perfusion and permeability studies in high field using dynamic contrast enhancement
    • DOI 10.1007/s00330-006-0198-1
    • de Bazelaire C, Rofsky NM, Duhamel G, et al. Combined T2* and T1 measurements for improved perfusion and permeability studies in high field using dynamic contrast enhancement. Eur Radiol 2006; 16: 2083-2091. (Pubitemid 44193193)
    • (2006) European Radiology , vol.16 , Issue.9 , pp. 2083-2091
    • De Bazelaire, C.1    Rofsky, N.M.2    Duhamel, G.3    Zhang, J.4    Michaelson, M.D.5    George, D.6    Alsop, D.C.7
  • 10
    • 12844284000 scopus 로고    scopus 로고
    • Effect of intravascular-to-extravascular water exchange on the determination of blood-to-tissue transfer constant by magnetic resonance imaging
    • DOI 10.1002/mrm.20340
    • Cao Y, Brown SL, Knight RA, Fenstermacher JD, Ewing JR,. Effect of intravascular-to-extravascular water exchange on the determination of blood-to-tissue transfer constant by magnetic resonance imaging. Magn Reson Med 2005; 53: 282-293. (Pubitemid 40171042)
    • (2005) Magnetic Resonance in Medicine , vol.53 , Issue.2 , pp. 282-293
    • Cao, Y.1    Brown, S.L.2    Knight, R.A.3    Fenstermacher, J.D.4    Ewing, J.R.5
  • 12
    • 0032587759 scopus 로고    scopus 로고
    • 2*shortening in contrast-enhanced MRI of the breast
    • DOI 10.1002/(SICI)1522-2586(199902)9:2<172::AID-JMRI4>3.0.CO;2-G
    • Kuperman VY, Alley MT,. Differentiation between the effects of T1 and T2* shortening in contrast-enhanced MRI of the breast. J Magn Reson Imaging 1999; 9: 172-176. (Pubitemid 29115338)
    • (1999) Journal of Magnetic Resonance Imaging , vol.9 , Issue.2 , pp. 172-176
    • Kuperman, V.Y.1    Alley, M.T.2
  • 13
    • 51449099619 scopus 로고    scopus 로고
    • Investigation and optimization of parameter accuracy in dynamic contrast-enhanced MRI
    • Cheng HL,. Investigation and optimization of parameter accuracy in dynamic contrast-enhanced MRI. J Magn Reson Imaging 2008; 28: 736-743.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 736-743
    • Cheng, H.L.1
  • 15
    • 35448956182 scopus 로고    scopus 로고
    • Correcting saturation effects of the arterial input function in dynamic susceptibility contrast-enhanced MRI - a Monte Carlo simulation
    • DOI 10.1016/j.mri.2007.03.011, PII S0730725X07002081
    • Brunecker P, Villringer A, Schultze J, et al. Correcting saturation effects of the arterial input function in dynamic susceptibility contrast-enhanced MRI: a Monte Carlo simulation. Magn Reson Imaging 2007; 25: 1300-1311. (Pubitemid 47625920)
    • (2007) Magnetic Resonance Imaging , vol.25 , Issue.9 , pp. 1300-1311
    • Brunecker, P.1    Villringer, A.2    Schultze, J.3    Nolte, C.H.4    Jungehulsing, G.J.5    Endres, M.6    Steinbrink, J.7
  • 17
    • 33746586521 scopus 로고    scopus 로고
    • A practical approach for quantitative estimates of voxel-by-voxel liver perfusion using DCE imaging and a compartmental model
    • DOI 10.1118/1.2219773
    • Cao Y, Alspaugh J, Shen Z, Balter JM, Lawrence TS, Ten Haken RK,. A practical approach for quantitative estimates of voxel-by-voxel liver perfusion using DCE imaging and a compartmental model. Med Phys 2006; 33: 3057-3062. (Pubitemid 44154577)
    • (2006) Medical Physics , vol.33 , Issue.8 , pp. 3057-3062
    • Cao, Y.1    Alspaugh, J.2    Shen, Z.3    Balter, J.M.4    Lawrence, T.S.5    Ten Haken, R.K.6
  • 19
    • 0027264993 scopus 로고
    • Probability of radiation-induced complications in normal tissues with parallel architecture under conditions of uniform whole or partial organ irradiation
    • Yorke ED, Kutcher GJ, Jackson A, Ling CC,. Probability of radiation-induced complications in normal tissues with parallel architecture under conditions of uniform whole or partial organ irradiation. Radiother Oncol 1993; 26: 226-237. (Pubitemid 23132291)
    • (1993) Radiotherapy and Oncology , vol.26 , Issue.3 , pp. 226-237
    • Yorke, E.D.1    Kutcher, G.J.2    Jackson, A.3    Ling, C.C.4
  • 22
    • 0027222535 scopus 로고
    • Probability of radiation-induced complications for normal tissues with parallel architecture subject to non-uniform irradiation
    • DOI 10.1118/1.597056
    • Jackson A, Kutcher GJ, Yorke ED,. Probability of radiation-induced complications for normal tissues with parallel architecture subject to non-uniform irradiation. Med Phys 1993; 20: 613-625. (Pubitemid 23195700)
    • (1993) Medical Physics , vol.20 , Issue.3 , pp. 613-625
    • Jackson, A.1    Kutcher, G.J.2    Yorke, E.D.3
  • 23
    • 65949095212 scopus 로고    scopus 로고
    • Average arterial input function for quantitative dynamic contrast enhanced magnetic resonance imaging of neck nodal metastases
    • Shukla-Dave A, Lee N, Stambuk H, et al. Average arterial input function for quantitative dynamic contrast enhanced magnetic resonance imaging of neck nodal metastases. BMC Med Phys 2009; 9: 4.
    • (2009) BMC Med Phys , vol.9 , pp. 4
    • Shukla-Dave, A.1    Lee, N.2    Stambuk, H.3
  • 24
    • 2942572936 scopus 로고    scopus 로고
    • The effects of renal variation upon measurements of perfusion and leakage volume in breast tumours
    • DOI 10.1088/0031-9155/49/10/014, PII S0031915504699222
    • Ahearn TS, Staff RT, Redpath TW, Semple SI,. The effects of renal variation upon measurements of perfusion and leakage volume in breast tumours. Phys Med Biol 2004; 49: 2041-2051. (Pubitemid 38735490)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.10 , pp. 2041-2051
    • Ahearn, T.S.1    Staff, R.T.2    Redpath, T.W.3    Semple, S.I.K.4
  • 25
    • 77649180156 scopus 로고    scopus 로고
    • Comparison between population average and experimentally measured arterial input function in predicting biopsy results in prostate cancer
    • Meng R, Chang SD, Jones EC, Goldenberg SL, Kozlowski P,. Comparison between population average and experimentally measured arterial input function in predicting biopsy results in prostate cancer. Acad Radiol 2010; 17: 520-525.
    • (2010) Acad Radiol , vol.17 , pp. 520-525
    • Meng, R.1    Chang, S.D.2    Jones, E.C.3    Goldenberg, S.L.4    Kozlowski, P.5
  • 26
    • 0031758817 scopus 로고    scopus 로고
    • A new method for imaging perfusion and contrast extraction fraction: Input functions derived from reference tissues
    • DOI 10.1002/jmri.1880080519
    • Kovar DF, Lewis M, Karczmar GS,. A new method for imaging perfusion and contrast extraction fraction: input functions derived from reference tissues. J Magn Reson Imaging 1998; 8: 1126-1134. (Pubitemid 28481800)
    • (1998) Journal of Magnetic Resonance Imaging , vol.8 , Issue.5 , pp. 1126-1134
    • Kovar, D.A.1    Lewis, M.2    Karczmar, G.S.3
  • 27
    • 36849089536 scopus 로고    scopus 로고
    • Multiple reference tissue method for contrast agent arterial input function estimation
    • DOI 10.1002/mrm.21311
    • Yang C, Karczmar GS, Medved M, Stadler WM,. Multiple reference tissue method for contrast agent arterial input function estimation. Magn Reson Med 2007; 58: 1266-1275. (Pubitemid 350234214)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.6 , pp. 1266-1275
    • Yang, C.1    Karczmar, G.S.2    Medved, M.3    Stadler, W.M.4
  • 28
    • 78149289435 scopus 로고    scopus 로고
    • Use of a reference tissue and blood vessel to measure the arterial input function in DCEMRI
    • Fan X, Haney CR, Mustafi D, et al. Use of a reference tissue and blood vessel to measure the arterial input function in DCEMRI. Magn Reson Med 2010; 64: 1821-1826.
    • (2010) Magn Reson Med , vol.64 , pp. 1821-1826
    • Fan, X.1    Haney, C.R.2    Mustafi, D.3
  • 30
    • 0030226098 scopus 로고    scopus 로고
    • Differentiating between T1 and T2*changes caused by gadopentetate dimeglumine in the kidney by using a double-echo dynamic MR imaging sequence
    • Kuperman VY, Karczmar GS, Blomley MJ, Lewis MZ, Lubich LM, Lipton MJ,. Differentiating between T1 and T2* changes caused by gadopentetate dimeglumine in the kidney by using a double-echo dynamic MR imaging sequence. J Magn Reson Imaging 1996; 6: 764-768. (Pubitemid 126702021)
    • (1996) Journal of Magnetic Resonance Imaging , vol.6 , Issue.5 , pp. 764-768
    • Kuperman, V.Yu.1    Karczmar, G.S.2    Blomley, M.J.K.3    Lewis, M.Z.4    Lubich, L.M.5    Lipton, M.J.6
  • 31
    • 30844467977 scopus 로고    scopus 로고
    • Double-echo perfusion-weighted MR imaging: Basic concepts and application in brain tumors for the assessment of tumor blood volume and vascular permeability
    • DOI 10.1007/s00330-005-2807-9
    • Uematsu H, Maeda M,. Double-echo perfusion-weighted MR imaging: basic concepts and application in brain tumors for the assessment of tumor blood volume and vascular permeability. Eur Radiol 2006; 16: 180-186. (Pubitemid 43103583)
    • (2006) European Radiology , vol.16 , Issue.1 , pp. 180-186
    • Uematsu, H.1    Maeda, M.2
  • 32
    • 77955098291 scopus 로고    scopus 로고
    • Phase-based arterial input function measurements for dynamic susceptibility contrast MRI
    • Bleeker EJ, van Buchem MA, Webb AG, van Osch MJ,. Phase-based arterial input function measurements for dynamic susceptibility contrast MRI. Magn Reson Med 2010; 64: 358-368.
    • (2010) Magn Reson Med , vol.64 , pp. 358-368
    • Bleeker, E.J.1    Van Buchem, M.A.2    Webb, A.G.3    Van Osch, M.J.4
  • 33
    • 79960601892 scopus 로고    scopus 로고
    • Arterial input functions determined from MR signal magnitude and phase for quantitative dynamic contrast-enhanced MRI in the human pelvis
    • Cron GO, Foottit C, Yankeelov TE, Avruch LI, Schweitzer ME, Cameron I,. Arterial input functions determined from MR signal magnitude and phase for quantitative dynamic contrast-enhanced MRI in the human pelvis. Magn Reson Med 2011; 66: 498-504.
    • (2011) Magn Reson Med , vol.66 , pp. 498-504
    • Cron, G.O.1    Foottit, C.2    Yankeelov, T.E.3    Avruch, L.I.4    Schweitzer, M.E.5    Cameron, I.6
  • 34
    • 80054803021 scopus 로고    scopus 로고
    • Phase-based arterial input function measurements in the femoral arteries for quantification of dynamic contrast-enhanced (DCE) MRI and comparison with DCE-CT
    • Korporaal JG, van den Berg CA, van Osch MJ, Groenendaal G, van Vulpen M, van der Heide UA,. Phase-based arterial input function measurements in the femoral arteries for quantification of dynamic contrast-enhanced (DCE) MRI and comparison with DCE-CT. Magn Reson Med 2011; 66: 1267-1274.
    • (2011) Magn Reson Med , vol.66 , pp. 1267-1274
    • Korporaal, J.G.1    Van Den Berg, C.A.2    Van Osch, M.J.3    Groenendaal, G.4    Van Vulpen, M.5    Van Der Heide, U.A.6
  • 36
    • 78149334316 scopus 로고    scopus 로고
    • A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: II. in vivo results
    • Schabel MC, DiBella EV, Jensen RL, Salzman KL,. A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: II. In vivo results. Phys Med Biol 2010; 55: 4807-4823.
    • (2010) Phys Med Biol , vol.55 , pp. 4807-4823
    • Schabel, M.C.1    Dibella, E.V.2    Jensen, R.L.3    Salzman, K.L.4
  • 37
    • 78149354861 scopus 로고    scopus 로고
    • A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations
    • Schabel MC, Fluckiger JU, DiBella EV,. A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations. Phys Med Biol 2010; 55: 4783-4806.
    • (2010) Phys Med Biol , vol.55 , pp. 4783-4806
    • Schabel, M.C.1    Fluckiger, J.U.2    Dibella, E.V.3
  • 38
    • 0035739233 scopus 로고    scopus 로고
    • Accuracy of deconvolution analysis based on singular value decomposition for quantification of cerebral blood flow using dynamic susceptibility contrast-enhanced magnetic resonance imaging
    • DOI 10.1088/0031-9155/46/12/306, PII S0031915501273011
    • Murase K, Shinohara M, Yamazaki Y,. Accuracy of deconvolution analysis based on singular value decomposition for quantification of cerebral blood flow using dynamic susceptibility contrast-enhanced magnetic resonance imaging. Phys Med Biol 2001; 46: 3147-3159. (Pubitemid 34568064)
    • (2001) Physics in Medicine and Biology , vol.46 , Issue.12 , pp. 3147-3159
    • Murase, K.1    Shinohara, M.2    Yamazaki, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.