메뉴 건너뛰기




Volumn 23, Issue 6, 2012, Pages 1533-1542

Biotribological study of large diameter ceramic-on-CFR-PEEK hip joint including fluid uptake, wear and frictional heating

Author keywords

[No Author keywords available]

Indexed keywords

ACETABULAR CUP; FEMORAL HEADS; FIBRE REINFORCED; FLUID UPTAKE; FRICTION FACTORS; FRICTIONAL HEAT; FRICTIONAL HEATING; HIP JOINTS; HIP SIMULATORS; IN-SITU; INCLINATION ANGLES; LARGE DIAMETER; NOVEL MATERIALS; ROOM TEMPERATURE; SOAK CONTROL; TEMPERATURE CHANGES; WEAR RATES;

EID: 84863334071     PISSN: 09574530     EISSN: 15734838     Source Type: Journal    
DOI: 10.1007/s10856-012-4617-3     Document Type: Article
Times cited : (42)

References (24)
  • 1
    • 0041527157 scopus 로고    scopus 로고
    • Levels of metal ions after small- and large- diameter metal-on-metal hip arthroplasty
    • Clarke MT, Lee PTH, Arora A, Villar RN. Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty. J Bone Joint Surg British Vol. 2003;85B(6):913-7. doi:10.1302/0301-620x.85b6.14166. (Pubitemid 36986860)
    • (2003) Journal of Bone and Joint Surgery - Series B , vol.85 , Issue.6 , pp. 913-917
    • Clarke, M.T.1    Lee, P.T.H.2    Arora, A.3    Villar, R.N.4
  • 2
    • 9644270292 scopus 로고    scopus 로고
    • A consensus paper on metal ions in metal-on-metal hip arthroplasties
    • DOI 10.1016/j.arth.2004.09.009, PII S088354030400508X
    • MacDonald SJ, Brodner W, Jacobs JJ. A consensus paper on metal ions in metal-on-metal hip arthroplasties. J Arthroplasty. 2004;19(8):12-6. doi:10.1016/j.arth.2004.09.009. (Pubitemid 39575821)
    • (2004) Journal of Arthroplasty , vol.19 , Issue.SUPPL. , pp. 12-16
    • MacDonald, S.J.1    Brodner, W.2    Jacobs, J.J.3
  • 3
    • 53849111555 scopus 로고    scopus 로고
    • Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement
    • De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg British Vol. 2008;90B(10): 1291-7.
    • (2008) J Bone Joint Surg British , vol.90 B , Issue.10 , pp. 1291-1297
    • De Haan, R.1    Pattyn, C.2    Gill, H.S.3    Murray, D.W.4    Campbell, P.A.5    De Smet, K.6
  • 4
    • 48149098921 scopus 로고    scopus 로고
    • Head size, does it matter?
    • doi:10.1016/j.cuor.2008.05.003
    • Grover M, Gandhe A. Head size, does it matter? Curr Orthop. 2008;22(3):155-64. doi:10.1016/j.cuor.2008.05.003.
    • (2008) Curr Orthop , vol.22 , Issue.3 , pp. 155-164
    • Grover, M.1    Gandhe, A.2
  • 5
    • 34548021405 scopus 로고    scopus 로고
    • PEEK biomaterials in trauma, orthopedic, and spinal implants
    • DOI 10.1016/j.biomaterials.2007.07.013, PII S0142961207005467
    • Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials. 2007;28(32):4845-69. doi: 10.1016/j.biomaterials.2007. 07.013. (Pubitemid 47285335)
    • (2007) Biomaterials , vol.28 , Issue.32 , pp. 4845-4869
    • Kurtz, S.M.1    Devine, J.N.2
  • 6
    • 0032201988 scopus 로고    scopus 로고
    • Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement
    • Wang A, Lin R, Polineni VK, Essner A, Stark C, Dumbleton JH. Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement. Tribol Int. 1998;31(11): 661-7.
    • (1998) Tribol Int , vol.31 , Issue.11 , pp. 661-667
    • Wang, A.1    Lin, R.2    Polineni, V.K.3    Essner, A.4    Stark, C.5    Dumbleton, J.H.6
  • 8
    • 47649088851 scopus 로고    scopus 로고
    • Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-etherketone) acetabular cup articulating against an alumina femoral head
    • Scholes SC, Inman IA, Unsworth A, Jones E. Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-etherketone) acetabular cup articulating against an alumina femoral head. Proc Inst Mech Eng H. 2008;222(3):273-83.
    • (2008) Proc Inst Mech Eng H , vol.222 , Issue.3 , pp. 273-283
    • Scholes, S.C.1    Inman, I.A.2    Unsworth, A.3    Jones, E.4
  • 9
    • 0036132150 scopus 로고    scopus 로고
    • Crack growth resistance of alumina, zirconia and zirconia toughened alumina ceramics for joint prostheses
    • DOI 10.1016/S0142-9612(01)00206-X, PII S014296120100206X
    • Chevalier J, De Aza AH, Fantozzi G, Schehl M, Torrecillas R. Crack growth resistance of alumina, zirconia and zirconia toughened alumina ceramics for joint prostheses. Biomaterials. 2002;23(3):937-45. (Pubitemid 33108971)
    • (2002) Biomaterials , vol.23 , Issue.3 , pp. 937-945
    • De Aza, A.H.1    Chevalier, J.2    Fantozzi, G.3    Schehl, M.4    Torrecillas, R.5
  • 10
    • 61649127532 scopus 로고    scopus 로고
    • Ceramics for medical applications: A picture for the next 20 years
    • doi:10.1016/j.jeurceramsoc.2008.08.025
    • Chevalier J, Gremillard L. Ceramics for medical applications: a picture for the next 20 years. J Eur Ceram Soc. 2009;29(7): 1245-55. doi:10.1016/j.jeurceramsoc.2008.08.025.
    • (2009) J Eur Ceram Soc , vol.29 , Issue.7 , pp. 1245-1255
    • Chevalier, J.1    Gremillard, L.2
  • 11
    • 36649012356 scopus 로고    scopus 로고
    • Evolution and new application of the alumina ceramics in joint replacement
    • DOI 10.1007/s00590-006-0181-1
    • Pria PD. Evolution and new application of the alumina ceramics in joint replacement. Eur J Orthop Surg Traumatol. 2007;17(3): 253-6. doi:10.1007/s00590-006-0181-1. (Pubitemid 350194100)
    • (2007) European Journal of Orthopaedic Surgery and Traumatology , vol.17 , Issue.3 , pp. 253-256
    • Dalla Pria, P.1
  • 12
    • 78649658341 scopus 로고    scopus 로고
    • Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX (R) delta ceramic-on-ceramic total hip replacement
    • doi:10.1002/Jbm.B.31708
    • Al-Hajjar M, Leslie IJ, Tipper J, Williams S, Fisher J, Jennings LM. Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX (R) delta ceramic-on-ceramic total hip replacement. J Biomed Mater Res Part B Appl Biomater. 2010;95B(2):263-8. doi:10.1002/Jbm.B.31708.
    • (2010) J Biomed Mater Res Part B Appl Biomater , vol.95 B , Issue.2 , pp. 263-268
    • Al-Hajjar, M.1    Leslie, I.J.2    Tipper, J.3    Williams, S.4    Fisher, J.5    Jennings, L.M.6
  • 13
    • 0033720349 scopus 로고    scopus 로고
    • Simplified motion and loading compared to physiological motion and loading in a hip joint simulator
    • Smith SL, Unsworth A. Simplified motion and loading compared to physiological motion and loading in a hip joint simulator. Proc Inst Mech Eng Part H J Eng Med. 2000;214(H3):233-8.
    • (2000) Proc Inst Mech Eng Part H J Eng Med , vol.214 , Issue.H3 , pp. 233-238
    • Smith, S.L.1    Unsworth, A.2
  • 17
    • 57349108642 scopus 로고    scopus 로고
    • Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-onmetal hip resurfacing
    • Hart AJ, Buddhdev P, Winship P, Faria N, Powell JJ, Skinner JA. Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-onmetal hip resurfacing. Hip Int. 2008;18(3):212-9.
    • (2008) Hip Int , vol.18 , Issue.3 , pp. 212-219
    • Hart, A.J.1    Buddhdev, P.2    Winship, P.3    Faria, N.4    Powell, J.J.5    Skinner, J.A.6
  • 18
    • 0035114433 scopus 로고    scopus 로고
    • The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator
    • DOI 10.1023/A:1008970027306
    • Nevelos JE, Ingham E, Doyle C, Nevelos AB, Fisher J. The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator. J Mater Sci Mater Med. 2001;12(2):141-4. (Pubitemid 32178864)
    • (2001) Journal of Materials Science: Materials in Medicine , vol.12 , Issue.2 , pp. 141-144
    • Nevelos, J.E.1    Ingham, E.2    Doyle, C.3    Nevelos, A.B.4    Fisher, J.5
  • 19
    • 0033252313 scopus 로고    scopus 로고
    • A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium- molybdenum femoral heads in a hip simulator
    • Smith SL, Unsworth A. A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator. Proc Inst Mech Eng Part H J Eng Med. 1999;213(6):475-83.
    • (1999) Proc Inst Mech Eng Part H J Eng Med , vol.213 , Issue.6 , pp. 475-483
    • Smith, S.L.1    Unsworth, A.2
  • 20
    • 0033252596 scopus 로고    scopus 로고
    • A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates
    • Barbour PSM, Stone MH, Fisher J. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates. Proc Inst Mech Eng Part H J Eng Med. 1999;213(H6):455-67.
    • (1999) Proc Inst Mech Eng Part H J Eng Med , vol.213 , Issue.H6 , pp. 455-467
    • Barbour, P.S.M.1    Stone, M.H.2    Fisher, J.3
  • 21
    • 70450200165 scopus 로고    scopus 로고
    • Tribological and surface analysis of 38 mm alumina-as-cast Co-Cr-Mo total hip arthroplasties
    • doi:10.1243/09544119jeim590
    • Williams SR, Wu JJ, Unsworth A, Khan I. Tribological and surface analysis of 38 mm alumina-as-cast Co-Cr-Mo total hip arthroplasties. Proc Inst Mech Eng Part H J Eng Med. 2009;223(H8):941-54. doi:10.1243/09544119jeim590.
    • (2009) Proc Inst Mech Eng Part H J Eng Med , vol.223 , Issue.H8 , pp. 941-954
    • Williams, S.R.1    Wu, J.J.2    Unsworth, A.3    Khan, I.4
  • 22
    • 80051903885 scopus 로고    scopus 로고
    • Wear and surface analysis of 38 mm ceramic-on-metal total hip replacements under standard and severe wear testing conditions
    • doi:10.1177/0954411911404773
    • Williams SR, Wu JJ, Unsworth A, Khan I. Wear and surface analysis of 38 mm ceramic-on-metal total hip replacements under standard and severe wear testing conditions. Proc Inst Mech Eng Part H J Eng Med. 2011;225(H8):783-96. doi:10.1177/09544119 11404773.
    • (2011) Proc Inst Mech Eng Part H J Eng Med , vol.225 , Issue.H8 , pp. 783-796
    • Williams, S.R.1    Wu, J.J.2    Unsworth, A.3    Khan, I.4
  • 23
    • 79960034079 scopus 로고    scopus 로고
    • Heat generated by hip resurfacing prostheses: An in vivo pilot study
    • Pritchett JW. Heat generated by hip resurfacing prostheses: an in vivo pilot study. J Long Term Effects of Med Implants. 2011; 21(1):55-62.
    • (2011) J Long Term Effects of Med Implants , vol.21 , Issue.1 , pp. 55-62
    • Pritchett, J.W.1
  • 24
    • 0035099422 scopus 로고    scopus 로고
    • Frictional heating of total hip implants, Part 1: Measurements in patients
    • DOI 10.1016/S0021-9290(00)00188-3, PII S0021929000001883
    • Bergmann G, Graichen F, Rohlmann A, Verdonschot N, van Lenthe GH. Frictional heating of total hip implants. Part 1: measurements in patients. J Biomech. 2001;34(4):421-8. (Pubitemid 32215466)
    • (2001) Journal of Biomechanics , vol.34 , Issue.4 , pp. 421-428
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3    Verdonschot, N.4    Van Lenthe, G.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.