메뉴 건너뛰기




Volumn 22, Issue 3, 2008, Pages 155-164

(i) Head size, does it matter?

Author keywords

Bearings; Head size; Hip replacement

Indexed keywords

ALLOY; CHROMIUM; COBALT; METAL; POLYETHYLENE;

EID: 48149098921     PISSN: 02680890     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cuor.2008.05.003     Document Type: Article
Times cited : (10)

References (33)
  • 1
    • 0014848821 scopus 로고
    • Total hip replacement by low-friction arthroplasty
    • Charnley J. Total hip replacement by low-friction arthroplasty. Clin Orthop Relat Res 72 (1970) 7-21
    • (1970) Clin Orthop Relat Res , vol.72 , pp. 7-21
    • Charnley, J.1
  • 2
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J., Ilstrup D., and Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 72 4 (1990) 518-528
    • (1990) J Bone Joint Surg Am , vol.72 , Issue.4 , pp. 518-528
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 3
    • 0034538341 scopus 로고    scopus 로고
    • Internal fixation versus hemiarthroplasty versus total hip arthroplasty for displaced subcapital fractures of femur - 13 year results of a prospective randomised study
    • Ravikumar K.J., and Marsh G. Internal fixation versus hemiarthroplasty versus total hip arthroplasty for displaced subcapital fractures of femur - 13 year results of a prospective randomised study. Injury 31 10 (2000) 793-797
    • (2000) Injury , vol.31 , Issue.10 , pp. 793-797
    • Ravikumar, K.J.1    Marsh, G.2
  • 4
    • 0033972562 scopus 로고    scopus 로고
    • Design issues in clinical studies of the in vivo volumetric wear rate of polyethylene bearing components
    • Lewis G. Design issues in clinical studies of the in vivo volumetric wear rate of polyethylene bearing components. J Bone Joint Surg Am 82 2 (2000) 281-287
    • (2000) J Bone Joint Surg Am , vol.82 , Issue.2 , pp. 281-287
    • Lewis, G.1
  • 5
    • 0030666239 scopus 로고    scopus 로고
    • Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups
    • Yamaguchi M., Bauer T.W., and Hashimoto Y. Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups. J Bone Joint Surg Am 79 10 (1997) 1539-1544
    • (1997) J Bone Joint Surg Am , vol.79 , Issue.10 , pp. 1539-1544
    • Yamaguchi, M.1    Bauer, T.W.2    Hashimoto, Y.3
  • 7
    • 0015429842 scopus 로고
    • Loosening of the cemented acetabular cup in total hip replacement
    • Andersson G.B., Freeman M.A., and Swanson S.A. Loosening of the cemented acetabular cup in total hip replacement. J Bone Joint Surg Br 54 4 (1972) 590-599
    • (1972) J Bone Joint Surg Br , vol.54 , Issue.4 , pp. 590-599
    • Andersson, G.B.1    Freeman, M.A.2    Swanson, S.A.3
  • 8
    • 0024522550 scopus 로고
    • Size of the femoral head and acetabular revision in total hip-replacement arthroplasty
    • Morrey B.F., and Ilstrup D. Size of the femoral head and acetabular revision in total hip-replacement arthroplasty. J Bone Joint Surg Am 71 1 (1989) 50-55
    • (1989) J Bone Joint Surg Am , vol.71 , Issue.1 , pp. 50-55
    • Morrey, B.F.1    Ilstrup, D.2
  • 9
    • 0025679123 scopus 로고
    • Dislocation after total hip arthroplasty. Causes and prevention
    • McCollum D.E., and Gray W.J. Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop Relat Res 261 (1990) 159-170
    • (1990) Clin Orthop Relat Res , vol.261 , pp. 159-170
    • McCollum, D.E.1    Gray, W.J.2
  • 10
    • 0020357069 scopus 로고
    • Recurrent and non-recurrent dislocation following total hip arthroplasty
    • Lindberg H.O., Carlsson A.S., Gentz C.F., and Pettersson H. Recurrent and non-recurrent dislocation following total hip arthroplasty. Acta Orthop Scand 53 6 (1982) 947-952
    • (1982) Acta Orthop Scand , vol.53 , Issue.6 , pp. 947-952
    • Lindberg, H.O.1    Carlsson, A.S.2    Gentz, C.F.3    Pettersson, H.4
  • 11
    • 12344321393 scopus 로고    scopus 로고
    • Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes
    • Burroughs B.R., Hallstrom B., Golladay G.J., Hoeffel D., and Harris W.H. Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes. J Arthroplasty 20 1 (2005) 11-19
    • (2005) J Arthroplasty , vol.20 , Issue.1 , pp. 11-19
    • Burroughs, B.R.1    Hallstrom, B.2    Golladay, G.J.3    Hoeffel, D.4    Harris, W.H.5
  • 12
    • 0033819163 scopus 로고    scopus 로고
    • The effect of femoral component head size on posterior dislocation of the artificial hip joint
    • Bartz R.L., Nobel P.C., Kadakia N.R., and Tullos H.S. The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am 82 9 (2000) 1300-1307
    • (2000) J Bone Joint Surg Am , vol.82 , Issue.9 , pp. 1300-1307
    • Bartz, R.L.1    Nobel, P.C.2    Kadakia, N.R.3    Tullos, H.S.4
  • 13
    • 0016707369 scopus 로고
    • Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus
    • Amstutz H.C., Lodwig R.M., Schurman D.J., and Hodgson A.G. Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus. Clin Orthop Relat Res 111 (1975) 124-130
    • (1975) Clin Orthop Relat Res , vol.111 , pp. 124-130
    • Amstutz, H.C.1    Lodwig, R.M.2    Schurman, D.J.3    Hodgson, A.G.4
  • 14
    • 37349100981 scopus 로고    scopus 로고
    • Effect of femoral head size and abductors on dislocation after revision THA
    • Kung P.L., and Ries M.D. Effect of femoral head size and abductors on dislocation after revision THA. Clin Orthop Relat Res 465 (2007) 170-174
    • (2007) Clin Orthop Relat Res , vol.465 , pp. 170-174
    • Kung, P.L.1    Ries, M.D.2
  • 15
    • 0142209293 scopus 로고    scopus 로고
    • Norwegian Arthroplasty Register. Femoral head size is a risk factor for total hip luxation: a study of 42,987 primary hip arthroplasties from the Norwegian Arthroplasty Register
    • Byström S., Espehaug B., Furnes O., and Havelin L.I. Norwegian Arthroplasty Register. Femoral head size is a risk factor for total hip luxation: a study of 42,987 primary hip arthroplasties from the Norwegian Arthroplasty Register. Acta Orthop Scand 74 5 (2003) 514-524
    • (2003) Acta Orthop Scand , vol.74 , Issue.5 , pp. 514-524
    • Byström, S.1    Espehaug, B.2    Furnes, O.3    Havelin, L.I.4
  • 16
    • 0942263539 scopus 로고    scopus 로고
    • Wear behaviour of ceramic-on-ceramic system: in vitro studies on hip joint simulator
    • Rieker C., Oberholzer S., and Wyss U. (Eds), Hans Huber
    • Affatato S., Bordini B., Sudanese A., et al. Wear behaviour of ceramic-on-ceramic system: in vitro studies on hip joint simulator. In: Rieker C., Oberholzer S., and Wyss U. (Eds). World tribology forum in arthroplasty (2001), Hans Huber 305-307
    • (2001) World tribology forum in arthroplasty , pp. 305-307
    • Affatato, S.1    Bordini, B.2    Sudanese, A.3
  • 18
    • 0024378353 scopus 로고
    • The wear behavior of capsules and heads of CoCrMo casts in long-term implanted all-metal hip prostheses
    • Semlitsch M., Streicher R.M., and Weber H. The wear behavior of capsules and heads of CoCrMo casts in long-term implanted all-metal hip prostheses. Orthopade 18 5 (1989) 377-381
    • (1989) Orthopade , vol.18 , Issue.5 , pp. 377-381
    • Semlitsch, M.1    Streicher, R.M.2    Weber, H.3
  • 19
    • 0034028044 scopus 로고    scopus 로고
    • Direct experimental evidence of lubrication in a metal-on-metal total hip replacement tested in a joint simulator
    • Dowson D., McNie CM., and Goldsmith A.A.J. Direct experimental evidence of lubrication in a metal-on-metal total hip replacement tested in a joint simulator. J Mech Eng Sci 214 (2000) 75-86
    • (2000) J Mech Eng Sci , vol.214 , pp. 75-86
    • Dowson, D.1    McNie, CM.2    Goldsmith, A.A.J.3
  • 20
    • 0038818314 scopus 로고    scopus 로고
    • Does metal-on-metal total hip prosthesis have influence on cancer? A long-term follow-up study
    • Rieker C., Oberholzer S., and Wyss U. (Eds), Hans Huber
    • Visuri T., and Pukkala E. Does metal-on-metal total hip prosthesis have influence on cancer? A long-term follow-up study. In: Rieker C., Oberholzer S., and Wyss U. (Eds). World tribology forum in arthroplasty (2001), Hans Huber 181-187
    • (2001) World tribology forum in arthroplasty , pp. 181-187
    • Visuri, T.1    Pukkala, E.2
  • 21
    • 0028365438 scopus 로고
    • Metal-induced developmental toxicity in mammals: a review
    • Domingo J.L. Metal-induced developmental toxicity in mammals: a review. J Toxicol Environ Health 42 2 (1994) 123-141
    • (1994) J Toxicol Environ Health , vol.42 , Issue.2 , pp. 123-141
    • Domingo, J.L.1
  • 22
    • 0030608421 scopus 로고    scopus 로고
    • Chromium induced teratogenicity in female rat
    • Kanojia R.K., Junaid M., and Murthy R.C. Chromium induced teratogenicity in female rat. Toxicol Lett 89 3 (1996) 207-213
    • (1996) Toxicol Lett , vol.89 , Issue.3 , pp. 207-213
    • Kanojia, R.K.1    Junaid, M.2    Murthy, R.C.3
  • 23
    • 27244459144 scopus 로고    scopus 로고
    • Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty
    • Davies A.P., Sood A., Lewis A.C., Newson R., Learmonth I.D., and Case C.P. Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty. J Bone Joint Surg Br 87 10 (2005) 1439-1444
    • (2005) J Bone Joint Surg Br , vol.87 , Issue.10 , pp. 1439-1444
    • Davies, A.P.1    Sood, A.2    Lewis, A.C.3    Newson, R.4    Learmonth, I.D.5    Case, C.P.6
  • 24
    • 34147191160 scopus 로고    scopus 로고
    • Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty: a controlled study
    • Ziaee H., Daniel J., Datta A.K., Blunt S., and McMinn D.J. Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty: a controlled study. J Bone Joint Surg Br 89 3 (2007) 301-305
    • (2007) J Bone Joint Surg Br , vol.89 , Issue.3 , pp. 301-305
    • Ziaee, H.1    Daniel, J.2    Datta, A.K.3    Blunt, S.4    McMinn, D.J.5
  • 25
    • 0347752406 scopus 로고    scopus 로고
    • A highly crosslinked, melted ulra-high molecular weight polyethylene: expanded potential for total joint arthroplasty
    • Rieker C., Oberholzer S., and Wyss U. (Eds), Hans Huber
    • Muratoglu O.K., Bragdon C.R., O'Connor D., Jasty M., and Harris W.H. A highly crosslinked, melted ulra-high molecular weight polyethylene: expanded potential for total joint arthroplasty. In: Rieker C., Oberholzer S., and Wyss U. (Eds). World tribology forum in arthroplasty (2001), Hans Huber 245-261
    • (2001) World tribology forum in arthroplasty , pp. 245-261
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.3    Jasty, M.4    Harris, W.H.5
  • 26
    • 33747887186 scopus 로고    scopus 로고
    • A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners
    • Engh Jr. C.A., Stepniewski A.S., Ginn S.D., Beykirch S.E., Sychterz-Terefenko C.J., Hopper Jr. R.H., and Engh C.A. A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners. J Arthroplasty 21 6 Suppl. 2 (2006) 17-25
    • (2006) J Arthroplasty , vol.21 , Issue.6 SUPPL. 2 , pp. 17-25
    • Engh Jr., C.A.1    Stepniewski, A.S.2    Ginn, S.D.3    Beykirch, S.E.4    Sychterz-Terefenko, C.J.5    Hopper Jr., R.H.6    Engh, C.A.7
  • 28
    • 2642564678 scopus 로고    scopus 로고
    • Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners
    • Bradford L., Baker D.A., Graham J., Chawan A., Ries M.D., and Pruitt L.A. Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. J Bone Joint Surg Am 86-A 6 (2004) 1271-1282
    • (2004) J Bone Joint Surg Am , vol.86 -A , Issue.6 , pp. 1271-1282
    • Bradford, L.1    Baker, D.A.2    Graham, J.3    Chawan, A.4    Ries, M.D.5    Pruitt, L.A.6
  • 29
  • 32
    • 0036484326 scopus 로고    scopus 로고
    • Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement
    • Beaulé P.A., Schmalzried T.P., Udomkiat P., and Amstutz H.C. Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement. J Bone Joint Surg Am 84-A 2 (2002) 256-263
    • (2002) J Bone Joint Surg Am , vol.84 -A , Issue.2 , pp. 256-263
    • Beaulé, P.A.1    Schmalzried, T.P.2    Udomkiat, P.3    Amstutz, H.C.4
  • 33
    • 0034890636 scopus 로고    scopus 로고
    • A novel low wearing differential hardness, ceramic-on-metal hip joint prosthesis
    • Firkins P.J., Tipper J.L., Ingham E., Stone M.H., Farrar R., and Fisher J. A novel low wearing differential hardness, ceramic-on-metal hip joint prosthesis. J Biomech 34 10 (2001) 1291-1298
    • (2001) J Biomech , vol.34 , Issue.10 , pp. 1291-1298
    • Firkins, P.J.1    Tipper, J.L.2    Ingham, E.3    Stone, M.H.4    Farrar, R.5    Fisher, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.