메뉴 건너뛰기




Volumn 5, Issue , 2012, Pages 487-504

Distance-of-flight mass spectrometry: A new paradigm for mass separation and detection

Author keywords

array detection; dynamic range; ion focusing; mass analysis; simultaneous analysis

Indexed keywords

ARRAY DETECTION; DYNAMIC RANGE; ION FOCUSING; MASS ANALYSIS; SIMULTANEOUS ANALYSIS;

EID: 84863329650     PISSN: 19361327     EISSN: 19361335     Source Type: Book Series    
DOI: 10.1146/annurev-anchem-091411-121050     Document Type: Review
Times cited : (17)

References (39)
  • 1
    • 84863336670 scopus 로고    scopus 로고
    • Distance of flight: A new paradigm for MS
    • Cassiday L. 2007. Distance of flight: a new paradigm for MS. Anal. Chem. 79:8830
    • (2007) Anal. Chem. , vol.79 , pp. 8830
    • Cassiday, L.1
  • 2
    • 81255150033 scopus 로고    scopus 로고
    • Resolution and mass range performance in distance-of-Flight mass spectrometry with a multichannel focal-Plane camera detector
    • Graham AW, Ray SJ, Enke CG, Felton JA, Barinaga CJ, et al. 2011. Resolution and mass range performance in distance-of-flight mass spectrometry with a multichannel focal-plane camera detector. Anal. Chem. 83:8552-59
    • (2011) Anal. Chem. , vol.83 , pp. 8552-8559
    • Graham, A.W.1    Ray, S.J.2    Enke, C.G.3    Felton, J.A.4    Barinaga, C.J.5
  • 3
    • 84863322618 scopus 로고    scopus 로고
    • Distance of flight spectrometer for MS and simultaneous scanless MS/MS
    • Enke CG. 2006. Distance of flight spectrometer for MS and simultaneous scanless MS/MS. US Patent 7,041,968
    • (2006) US Patent 7, 041, 968
    • Enke, C.G.1
  • 4
    • 0001635123 scopus 로고
    • Models for mass-Independent space and energy focusing in time-of-flight mass spectrometry
    • Yefchak GE, Enke CG, Holland JF. 1989. Models for mass-independent space and energy focusing in time-of-flight mass spectrometry. Int. J. Mass Spectrom. Ion Process. 87:313-30
    • (1989) Int. J. Mass Spectrom. Ion Process. , vol.87 , pp. 313-330
    • Yefchak, G.E.1    Enke, C.G.2    Holland, J.F.3
  • 5
    • 84990719386 scopus 로고
    • Orthogonal-Acceleration time-Of-Flight mass spectrometer
    • Dawson JHJ, Guilhaus M. 1989. Orthogonal-acceleration time-of-flight mass spectrometer. Rapid Commun. Mass Spectrom. 3:155-59
    • (1989) Rapid Commun. Mass Spectrom. , vol.3 , pp. 155-159
    • Dawson, J.H.J.1    Guilhaus, M.2
  • 7
    • 36448987578 scopus 로고    scopus 로고
    • Achievement of energy focus for distance-of-flight mass spectrometry with constant momentum acceleration and an ion mirror
    • DOI 10.1021/ac070638u
    • Enke CG, Dobson GS. 2007. Achievement of energy focus for distance-of-flight mass spectrometry with constant momentum acceleration and an ion mirror. Anal. Chem. 79:8650-61 (Pubitemid 350171376)
    • (2007) Analytical Chemistry , vol.79 , Issue.22 , pp. 8650-8661
    • Enke, C.G.1    Dobson, G.S.2
  • 8
    • 0042720267 scopus 로고
    • Pulsed mass spectrometer with time dispersion
    • Wolff MM, Stephens WE. 1953. Pulsed mass spectrometer with time dispersion. Rev. Sci. Instrum. 24:616-17
    • (1953) Rev. Sci. Instrum. , vol.24 , pp. 616-617
    • Wolff, M.M.1    Stephens, W.E.2
  • 9
    • 0012867739 scopus 로고
    • Multiple-focusing time of flight mass spectrometers Part I TOFMS with equal momentum acceleration
    • Poschenrieder WP. 1971. Multiple-focusing time of flight mass spectrometers. Part I.TOFMS with equal momentum acceleration. Int. J. Mass Spectrom. Ion Phys. 6:413-26
    • (1971) Int. J. Mass Spectrom. Ion Phys. , vol.6 , pp. 413-426
    • Poschenrieder, W.P.1
  • 10
    • 0031766541 scopus 로고    scopus 로고
    • Perfect velocity focusing in hyperbolic electrode source-drift space time-of-flight mass analysers
    • DOI 10.1002/(SICI)1097-0231(19981215) 12:23<1925::AID-RCM403>3.0. CO;2-A
    • Ioanoviciu D. 1998. Perfect velocity focusing in hyperbolic electrode source-drift space time-of-flight mass analyzers. Rapid Commun. Mass Spectrom. 12:1925-27 (Pubitemid 28548086)
    • (1998) Rapid Communications in Mass Spectrometry , vol.12 , Issue.23 , pp. 1925-1927
    • Ioanoviciu, D.1
  • 11
    • 0344240229 scopus 로고    scopus 로고
    • Delayed extraction-Constant momentum time-Of-Flight mass spectrometry
    • Ioanoviciu D. 1999. Delayed extraction-constant momentum time-of-flight mass spectrometry. Nucl. Instrum. Methods A 427:157-60
    • (1999) Nucl. Instrum. Methods A , vol.427 , pp. 157-160
    • Ioanoviciu, D.1
  • 15
    • 0030798882 scopus 로고    scopus 로고
    • Fundamentals of focal plane detectors
    • Birkenshaw K. 1997. Fundamentals of focal plane detectors. J. Mass Spectrom. 32:795-806
    • (1997) J. Mass Spectrom. , vol.32 , pp. 795-806
    • Birkenshaw, K.1
  • 17
    • 0037108802 scopus 로고    scopus 로고
    • Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 1. Use with a glow-discharge source
    • DOI 10.1021/ac020304z
    • Barnes JHIV, Sperline R, DentonMB, Barinaga CJ, Koppenaal D, et al. 2002. Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 1. Use with a glow-discharge source. Anal. Chem. 74:5327-32 (Pubitemid 35215363)
    • (2002) Analytical Chemistry , vol.74 , Issue.20 , pp. 5327-5332
    • Barnes IV, J.H.1    Sperline, R.2    Denton, M.B.3    Barinaga, C.J.4    Koppenaal, D.5    Young, E.T.6    Hieftje, G.M.7
  • 19
    • 33745700680 scopus 로고    scopus 로고
    • Characterization of a secondgeneration focal-plane camera coupled to an inductively coupled plasma Mattauch-Herzog geometry mass spectrograph
    • Schilling GD, Andrade FJ, Barnes JH, Sperline RP, Denton MB, et al. 2006. Characterization of a secondgeneration focal-plane camera coupled to an inductively coupled plasma Mattauch-Herzog geometry mass spectrograph. Anal. Chem. 78:4319-25
    • (2006) Anal. Chem. , vol.78 , pp. 4319-4325
    • Schilling, G.D.1    Andrade, F.J.2    Barnes, J.H.3    Sperline, R.P.4    Denton, M.B.5
  • 20
    • 67649966603 scopus 로고    scopus 로고
    • Evaluation of a 512-channel Faraday-strip array detector coupled to an inductively coupled plasma Mattauch-Herzog mass spectrograph
    • Schilling GD, Ray SJ, Rubinshtein AA, Felton JA, Sperline RP, et al. 2009. Evaluation of a 512-channel Faraday-strip array detector coupled to an inductively coupled plasma Mattauch-Herzog mass spectrograph. Anal. Chem. 81:5467-73
    • (2009) Anal. Chem. , vol.81 , pp. 5467-5473
    • Schilling, G.D.1    Ray, S.J.2    Rubinshtein, A.A.3    Felton, J.A.4    Sperline, R.P.5
  • 21
    • 79251569927 scopus 로고    scopus 로고
    • Evaluation of a fourth-Generation focal plane camera for use in plasma-Source mass spectrometry
    • Felton JA, Schilling GD, Ray SJ, Sperline RP, Denton MB, et al. 2011. Evaluation of a fourth-generation focal plane camera for use in plasma-source mass spectrometry. J. Anal. At. Spectrom. 26:300-4
    • (2011) J. Anal. At. Spectrom. , vol.26 , pp. 300-304
    • Felton, J.A.1    Schilling, G.D.2    Ray, S.J.3    Sperline, R.P.4    Denton, M.B.5
  • 22
    • 79953286679 scopus 로고    scopus 로고
    • Undetected components in natural mixtures: How many what concentrations do they account for chemical noise what is needed to detect them
    • Enke CG, Nagels LJ. 2011. Undetected components in natural mixtures: how many? What concentrations? Do they account for chemical noise? What is needed to detect them? Anal. Chem. 83:2539-46
    • (2011) Anal. Chem. , vol.83 , pp. 2539-2546
    • Enke, C.G.1    Nagels, L.J.2
  • 24
    • 0035418896 scopus 로고    scopus 로고
    • Collisions of ions with surfaces at chemically relevant energies: Instrumentation and phenomena
    • DOI 10.1063/1.1382641
    • Grill V, Shen J, Evans C, Cooks RG. 2001. Collisions of ions with surfaces at chemically relevant energies: instrumentation and phenomena. Rev. Sci. Instrum. 72:3149-79 (Pubitemid 33606943)
    • (2001) Review of Scientific Instruments , vol.72 , Issue.8 , pp. 3149-3179
    • Grill, V.1    Shen, J.2    Evans, C.3    Cooks, R.G.4
  • 26
    • 0031039897 scopus 로고    scopus 로고
    • Soft-landing of polyatomic ions at fluorinated self-assembled monolayer surfaces
    • DOI 10.1126/science.275.5305.1447
    • Miller SA, Luo H, Pachuta SJ, Cooks RG. 1997. Soft-landing of polyatomic ions at fluorinated selfassembled monolayer surfaces. Science 275:1447-50 (Pubitemid 27111285)
    • (1997) Science , vol.275 , Issue.5305 , pp. 1447-1450
    • Miller, S.A.1    Luo, H.2    Pachuta, S.J.3    Cooks, R.G.4
  • 28
    • 70349764781 scopus 로고    scopus 로고
    • Ultrahigh-Mass mass spectrometry of single biomolecules and bioparticles
    • Chang H-C. 2009. Ultrahigh-mass mass spectrometry of single biomolecules and bioparticles. Annu. Rev. Anal. Chem. 2:169-85
    • (2009) Annu. Rev. Anal. Chem. , vol.2 , pp. 169-185
    • Chang, H.-C.1
  • 29
    • 0034676012 scopus 로고    scopus 로고
    • Ion detection efficiency in SIMS: Dependencies on energy, mass and composition for microchannel plates used in mass spectrometry
    • Gilmore IS, Seah MP. 2000. Ion detection efficiency in SIMS: dependencies on energy, mass and composition for microchannel plates used in mass spectrometry. Int. J. Mass Spectrom. 202:217-29
    • (2000) Int. J. Mass Spectrom. , vol.202 , pp. 217-229
    • Gilmore, I.S.1    Seah, M.P.2
  • 30
    • 84863331488 scopus 로고    scopus 로고
    • HM2 HM2 TUVO next generation of high-Mass MALDI retrofit systems
    • Coval X. HM2 and HM2 TUVO: next generation of high-mass MALDI retrofit systems. Zürich: CovalX. http://www.covalx.com/files/HM2High-Mass-Systems. pdf
    • Zürich: CovalX.
    • Coval, X.1
  • 31
    • 27544477378 scopus 로고    scopus 로고
    • Analysis of megadalton ions using cryodetection MALDI time-of-flight mass spectrometry
    • DOI 10.1021/ac0482054
    • Wenzel RJ, Matter U, Schultheis L, Zenobi R. 2005. Analysis of megadalton ions using cryodetection MALDI time-of-flight mass spectrometry. Anal. Chem. 77:4329-37 (Pubitemid 41542250)
    • (2005) Analytical Chemistry , vol.77 , Issue.14 , pp. 4329-4337
    • Wenzel, R.J.1    Matter, U.2    Schultheis, L.3    Zenobi, R.4
  • 37
    • 0035860195 scopus 로고    scopus 로고
    • Noise analysis for 2D tandem Fourier transform ion cyclotron resonance mass spectrometry
    • DOI 10.1016/S1387-3806(01)00396-7, PII S1387380601003967
    • van der Rest G, Marshall AG. 2001. Noise analysis for two-dimensional tandem FT-ICR mass spectrometry. Int. J. Mass Spectrom. 208:101-11 (Pubitemid 32947090)
    • (2001) International Journal of Mass Spectrometry , vol.210-211 , pp. 101-111
    • Van Der Rest, G.1    Marshall, A.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.