메뉴 건너뛰기




Volumn 30, Issue 4, 2012, Pages 562-571

Multichannel transceiver dual-tuned RF coil for proton/sodium MR imaging of knee cartilage at 3 T

Author keywords

Dual tuned coil; Multitransceiver coil; Sodium MR imaging

Indexed keywords

SODIUM;

EID: 84862802779     PISSN: 0730725X     EISSN: 18735894     Source Type: Journal    
DOI: 10.1016/j.mri.2011.12.011     Document Type: Article
Times cited : (23)

References (42)
  • 1
    • 1442312192 scopus 로고    scopus 로고
    • An update on the pathogenesis and epidemiology of osteoarthritis
    • Felson D.T. An update on the pathogenesis and epidemiology of osteoarthritis. Radiol Clin North Am 2004, 42(1):1-9.
    • (2004) Radiol Clin North Am , vol.42 , Issue.1 , pp. 1-9
    • Felson, D.T.1
  • 3
    • 33748352137 scopus 로고    scopus 로고
    • Rapid 3D-T1rho mapping of the knee joint at 3.0T with parallel imaging
    • Pakin S.K., Xu J., Schweitzer M.E., Regatte R.R. Rapid 3D-T1rho mapping of the knee joint at 3.0T with parallel imaging. Magn Reson Med 2006, 56(3):563-571.
    • (2006) Magn Reson Med , vol.56 , Issue.3 , pp. 563-571
    • Pakin, S.K.1    Xu, J.2    Schweitzer, M.E.3    Regatte, R.R.4
  • 5
    • 0033810343 scopus 로고    scopus 로고
    • MRI techniques in early stages of cartilage disease
    • Burstein D., Bashir A., Gray M.L. MRI techniques in early stages of cartilage disease. Invest Radiol 2000, 35(10):622-638.
    • (2000) Invest Radiol , vol.35 , Issue.10 , pp. 622-638
    • Burstein, D.1    Bashir, A.2    Gray, M.L.3
  • 6
    • 0033820015 scopus 로고    scopus 로고
    • Anatomy, biochemistry, and physiology of articular cartilage
    • Huber M.M., Trattnig S.M., Lintner F.M. Anatomy, biochemistry, and physiology of articular cartilage. Invest Radiol 2000, 35(10):573-580.
    • (2000) Invest Radiol , vol.35 , Issue.10 , pp. 573-580
    • Huber, M.M.1    Trattnig, S.M.2    Lintner, F.M.3
  • 8
    • 0029657894 scopus 로고    scopus 로고
    • Gd-DTPA2 - as a measure of cartilage degradation
    • Bashir A., Gray M.L., Burstein D. Gd-DTPA2 - as a measure of cartilage degradation. Magn Reson Med 1996, 36(5):665-673.
    • (1996) Magn Reson Med , vol.36 , Issue.5 , pp. 665-673
    • Bashir, A.1    Gray, M.L.2    Burstein, D.3
  • 9
    • 37849006412 scopus 로고    scopus 로고
    • Rapid 3D-T(1) mapping of cartilage with variable flip angle and parallel imaging at 3.0T
    • Wang L., Schweitzer M.E., Padua A., Regatte R.R. Rapid 3D-T(1) mapping of cartilage with variable flip angle and parallel imaging at 3.0T. J Magn Reson Imaging 2008, 27(1):154-161.
    • (2008) J Magn Reson Imaging , vol.27 , Issue.1 , pp. 154-161
    • Wang, L.1    Schweitzer, M.E.2    Padua, A.3    Regatte, R.R.4
  • 10
    • 33751353597 scopus 로고    scopus 로고
    • Sodium and T1rho MRI for molecular and diagnostic imaging of articular cartilage
    • Borthakur A., Mellon E., Niyogi S., Witschey W., Kneeland J.B., Reddy R. Sodium and T1rho MRI for molecular and diagnostic imaging of articular cartilage. NMR Biomed 2006, 19(7):781-821.
    • (2006) NMR Biomed , vol.19 , Issue.7 , pp. 781-821
    • Borthakur, A.1    Mellon, E.2    Niyogi, S.3    Witschey, W.4    Kneeland, J.B.5    Reddy, R.6
  • 11
    • 3442883625 scopus 로고    scopus 로고
    • ECG-gated 23Na-MRI of the human heart using a 3D-radial projection technique with ultra-short echo times
    • Jerecic R., Bock M., Nielles-Vallespin S., Wacker C., Bauer W., Schad L.R. ECG-gated 23Na-MRI of the human heart using a 3D-radial projection technique with ultra-short echo times. MAGMA 2004, 16(6):297-302.
    • (2004) MAGMA , vol.16 , Issue.6 , pp. 297-302
    • Jerecic, R.1    Bock, M.2    Nielles-Vallespin, S.3    Wacker, C.4    Bauer, W.5    Schad, L.R.6
  • 12
    • 33846056503 scopus 로고    scopus 로고
    • 3D radial projection technique with ultrashort echo times for sodium MRI: clinical applications in human brain and skeletal muscle
    • Nielles-Vallespin S., Weber M.A., Bock M., Bongers A., Speier P., Combs S.E., et al. 3D radial projection technique with ultrashort echo times for sodium MRI: clinical applications in human brain and skeletal muscle. Magn Reson Med 2007, 57(1):74-81.
    • (2007) Magn Reson Med , vol.57 , Issue.1 , pp. 74-81
    • Nielles-Vallespin, S.1    Weber, M.A.2    Bock, M.3    Bongers, A.4    Speier, P.5    Combs, S.E.6
  • 14
    • 33646447508 scopus 로고    scopus 로고
    • Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling
    • Rahmer J., Bornert P., Groen J., Bos C. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn Reson Med 2006, 55(5):1075-1082.
    • (2006) Magn Reson Med , vol.55 , Issue.5 , pp. 1075-1082
    • Rahmer, J.1    Bornert, P.2    Groen, J.3    Bos, C.4
  • 15
    • 33749351574 scopus 로고    scopus 로고
    • MRI for development of disease-modifying osteoarthritis drugs
    • Burstein D. MRI for development of disease-modifying osteoarthritis drugs. NMR Biomed 2006, 19(6):669-680.
    • (2006) NMR Biomed , vol.19 , Issue.6 , pp. 669-680
    • Burstein, D.1
  • 16
    • 0032966322 scopus 로고    scopus 로고
    • Experimentally verified, theoretical design of dual-tuned, low-pass birdcage radiofrequency resonators for magnetic resonance imaging and magnetic resonance spectroscopy of human brain at 3.0 tesla
    • Shen G.X., Wu J.F., Boada F.E., Thulborn K.R. Experimentally verified, theoretical design of dual-tuned, low-pass birdcage radiofrequency resonators for magnetic resonance imaging and magnetic resonance spectroscopy of human brain at 3.0 tesla. Magn Reson Med 1999, 41(2):268-275.
    • (1999) Magn Reson Med , vol.41 , Issue.2 , pp. 268-275
    • Shen, G.X.1    Wu, J.F.2    Boada, F.E.3    Thulborn, K.R.4
  • 17
    • 33746280566 scopus 로고    scopus 로고
    • Practical design of a 4 Tesla double-tuned RF surface coil for interleaved 1H and 23Na MRI of rat brain
    • Alecci M., Romanzetti S., Kaffanke J., Celik A., Wegener H.P., Shah N.J. Practical design of a 4 Tesla double-tuned RF surface coil for interleaved 1H and 23Na MRI of rat brain. J Magn Reson 2006, 181(2):203-211.
    • (2006) J Magn Reson , vol.181 , Issue.2 , pp. 203-211
    • Alecci, M.1    Romanzetti, S.2    Kaffanke, J.3    Celik, A.4    Wegener, H.P.5    Shah, N.J.6
  • 20
    • 21244493990 scopus 로고    scopus 로고
    • Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging
    • Wiggins G.C., Potthast A., Triantafyllou C., Wiggins C.J., Wald L.L. Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging. Magn Reson Med 2005, 54(1):235-240.
    • (2005) Magn Reson Med , vol.54 , Issue.1 , pp. 235-240
    • Wiggins, G.C.1    Potthast, A.2    Triantafyllou, C.3    Wiggins, C.J.4    Wald, L.L.5
  • 21
    • 33746319143 scopus 로고    scopus 로고
    • A double resonant surface coil for 4.1T whole body NMR. ISMRM Proceedings
    • Vaughan J.T. A double resonant surface coil for 4.1T whole body NMR. ISMRM Proceedings. Proc Int Soc Magn Reson Med 1998, 6:722.
    • (1998) Proc Int Soc Magn Reson Med , vol.6 , pp. 722
    • Vaughan, J.T.1
  • 22
    • 84862813747 scopus 로고    scopus 로고
    • Performance comparison of a hybrid dual-tuned 23Na/1H birdcage to a single-tuned 23Na birdcage with identical geometry. ISMRM Proceedings
    • Peterson B., Watkins R., Morrell G., Allen S., Park D., Kaggie J., et al. Performance comparison of a hybrid dual-tuned 23Na/1H birdcage to a single-tuned 23Na birdcage with identical geometry. ISMRM Proceedings. Proc Int Soc Magn Reson Med 2010, 18:2134.
    • (2010) Proc Int Soc Magn Reson Med , vol.18 , pp. 2134
    • Peterson, B.1    Watkins, R.2    Morrell, G.3    Allen, S.4    Park, D.5    Kaggie, J.6
  • 24
    • 84919849153 scopus 로고    scopus 로고
    • A nested dual frequency birdcage/stripline coil for sodium/proton brain imaging at 7T. ISMRM Proceedings
    • Wiggins G.C., Brown R., Fleysher L., Zhang B., Stoeckel B., Inglese M., et al. A nested dual frequency birdcage/stripline coil for sodium/proton brain imaging at 7T. ISMRM Proceedings. Proc Int Soc Magn Reson Med 2010, 18:2159.
    • (2010) Proc Int Soc Magn Reson Med , vol.18 , pp. 2159
    • Wiggins, G.C.1    Brown, R.2    Fleysher, L.3    Zhang, B.4    Stoeckel, B.5    Inglese, M.6
  • 27
    • 33747885067 scopus 로고    scopus 로고
    • Design of an inductively decoupled microstrip array at 9.4 T
    • Wu B., Zhang X., Qu P., Shen G.X. Design of an inductively decoupled microstrip array at 9.4 T. J Magn Reson 2006, 182(1):126.
    • (2006) J Magn Reson , vol.182 , Issue.1 , pp. 126
    • Wu, B.1    Zhang, X.2    Qu, P.3    Shen, G.X.4
  • 29
    • 80051589403 scopus 로고    scopus 로고
    • Implementation of a 3D isotropic ultra-short TE (UTE) sequence. ISMRM Proceedings
    • Zhao T., Qian Y., Hue Y., Ibrahim T., Boad F. Implementation of a 3D isotropic ultra-short TE (UTE) sequence. ISMRM Proceedings. Proc Int Soc Magn Reson Med 2009, 17:2662.
    • (2009) Proc Int Soc Magn Reson Med , vol.17 , pp. 2662
    • Zhao, T.1    Qian, Y.2    Hue, Y.3    Ibrahim, T.4    Boad, F.5
  • 30
    • 0030697530 scopus 로고    scopus 로고
    • Spectrally weighted twisted projection imaging: reducing T2 signal attenuation effects in fast three-dimensional sodium imaging
    • Boada F.E., Shen G.X., Chang S.Y., Thulborn K.R. Spectrally weighted twisted projection imaging: reducing T2 signal attenuation effects in fast three-dimensional sodium imaging. Magn Reson Med 1997, 38(6):1022-1028.
    • (1997) Magn Reson Med , vol.38 , Issue.6 , pp. 1022-1028
    • Boada, F.E.1    Shen, G.X.2    Chang, S.Y.3    Thulborn, K.R.4
  • 31
    • 77957969466 scopus 로고    scopus 로고
    • Sodium inversion recovery MRI of the knee joint in-vivo at 7T
    • Madelin G., Lee J.S., Inati S., Jerschow A., Regatte R.R. Sodium inversion recovery MRI of the knee joint in-vivo at 7T. J Magn Reson 2010, 207(1):42-52.
    • (2010) J Magn Reson , vol.207 , Issue.1 , pp. 42-52
    • Madelin, G.1    Lee, J.S.2    Inati, S.3    Jerschow, A.4    Regatte, R.R.5
  • 32
    • 47549102408 scopus 로고    scopus 로고
    • Clean demarcation of cartilage tissue 23Na by inversion recovery
    • Rong P., Regatte R.R., Jerschow A. Clean demarcation of cartilage tissue 23Na by inversion recovery. J Magn Reson 2008, 193(2):207-209.
    • (2008) J Magn Reson , vol.193 , Issue.2 , pp. 207-209
    • Rong, P.1    Regatte, R.R.2    Jerschow, A.3
  • 33
    • 0032129166 scopus 로고    scopus 로고
    • Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI
    • Sled J.G., Pike G.B. Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI. IEEE Trans Med Imaging 1998, 17(4):653-662.
    • (1998) IEEE Trans Med Imaging , vol.17 , Issue.4 , pp. 653-662
    • Sled, J.G.1    Pike, G.B.2
  • 34
    • 0036238849 scopus 로고    scopus 로고
    • Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz
    • Collins C.M., Yang Q.X., Wang J.H., Zhang X., Liu H., Michaeli S., et al. Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz. Magn Reson Med 2002, 47(5):1026-1028.
    • (2002) Magn Reson Med , vol.47 , Issue.5 , pp. 1026-1028
    • Collins, C.M.1    Yang, Q.X.2    Wang, J.H.3    Zhang, X.4    Liu, H.5    Michaeli, S.6
  • 35
    • 0034900050 scopus 로고    scopus 로고
    • Radio frequency magnetic field mapping of a 3 tesla birdcage coil: experimental and theoretical dependence on sample properties
    • Marcello A., Christopher M.C., Michael B.S., Peter J. Radio frequency magnetic field mapping of a 3 tesla birdcage coil: experimental and theoretical dependence on sample properties. Magn Reson Med 2001, 46(2):379-385.
    • (2001) Magn Reson Med , vol.46 , Issue.2 , pp. 379-385
    • Marcello, A.1    Christopher, M.C.2    Michael, B.S.3    Peter, J.4
  • 36
    • 0036298536 scopus 로고    scopus 로고
    • Coupling and decoupling theory and its application to the MRI phased array
    • Lee R.F., Giaquinto R.O., Hardy C.J. Coupling and decoupling theory and its application to the MRI phased array. Magn Reson Med 2002, 48(1):203.
    • (2002) Magn Reson Med , vol.48 , Issue.1 , pp. 203
    • Lee, R.F.1    Giaquinto, R.O.2    Hardy, C.J.3
  • 38
    • 4243172418 scopus 로고    scopus 로고
    • Design of a capacitively decoupled transmit/receive NMR phased array for high field microscopy at 14.1 T
    • Zhang X., Webb A. Design of a capacitively decoupled transmit/receive NMR phased array for high field microscopy at 14.1 T. J Magn Reson 2004, 170(1):149.
    • (2004) J Magn Reson , vol.170 , Issue.1 , pp. 149
    • Zhang, X.1    Webb, A.2
  • 39
    • 28444473098 scopus 로고    scopus 로고
    • B1destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
    • Pierre-François Van de M., Can A., Gregor A., Steen M., Johannes R., Christopher M.C., et al. B1destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil. Magn Reson Med 2005, 54(6):1503-1518.
    • (2005) Magn Reson Med , vol.54 , Issue.6 , pp. 1503-1518
    • Pierre-François Van de, M.1    Can, A.2    Gregor, A.3    Steen, M.4    Johannes, R.5    Christopher, M.C.6
  • 40
    • 33749169500 scopus 로고    scopus 로고
    • Exploring the limits of RF shimming for high-field MRI of the human head
    • Mao W., Smith M.B., Collins C.M. Exploring the limits of RF shimming for high-field MRI of the human head. Magn Reson Med 2006, 56(4):918-922.
    • (2006) Magn Reson Med , vol.56 , Issue.4 , pp. 918-922
    • Mao, W.1    Smith, M.B.2    Collins, C.M.3
  • 42
    • 2442645287 scopus 로고    scopus 로고
    • Proteoglycan loss in human knee cartilage: quantitation with sodium MR imaging - feasibility study 1
    • Wheaton A.J., Borthakur A., Shapiro E.M., Regatte R.R., Akella S.V.S., Kneeland J.B., et al. Proteoglycan loss in human knee cartilage: quantitation with sodium MR imaging - feasibility study 1. Radiology 2004, 231(3):900-905.
    • (2004) Radiology , vol.231 , Issue.3 , pp. 900-905
    • Wheaton, A.J.1    Borthakur, A.2    Shapiro, E.M.3    Regatte, R.R.4    Akella, S.V.S.5    Kneeland, J.B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.