메뉴 건너뛰기




Volumn 57, Issue 2, 2010, Pages 397-403

7T Human Spine Imaging Arrays With Adjustable Inductive Decoupling

Author keywords

Array; decoupling; high field MRI; human spine; microstrip; parallel imaging; RF coil

Indexed keywords

ALGORITHM; ARTICLE; EQUIPMENT DESIGN; HISTOLOGY; HUMAN; IMAGE PROCESSING; INSTRUMENTATION; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; SPINE;

EID: 77950357155     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2009.2030170     Document Type: Article
Times cited : (64)

References (21)
  • 1
    • 0035107966 scopus 로고    scopus 로고
    • Specific coil design for SENSE: A six-element cardiac array
    • Mar.
    • M. Weiger, K. P. Pruessmann, C. Leussler, P. Roschmann, and P. Boesiger, “Specific coil design for SENSE: A six-element cardiac array,” Magn. Reson. Med., vol. 45, no. 3, pp. 495–504, Mar. 2001.
    • (2001) Magn. Reson. Med. , vol.45 , Issue.3 , pp. 495-504
    • Weiger, M.1    Pruessmann, K.P.2    Leussler, C.3    Roschmann, P.4    Boesiger, P.5
  • 2
    • 9944243829 scopus 로고    scopus 로고
    • The bandpass birdcage resonator modified as a coil array for simultaneous MR acquisition
    • C. Leussler, J. Stimma, and P. Roeschmann, “The bandpass birdcage resonator modified as a coil array for simultaneous MR acquisition,” in Proc. 5th Annu. Meeting ISMRM, 1997, p. 196.
    • (1997) Proc. 5th Annu. Meeting ISMRM , pp. 196
    • Leussler, C.1    Stimma, J.2    Roeschmann, P.3
  • 4
    • 0034121826 scopus 로고    scopus 로고
    • A multicoil array designed for cardiac SMASH imaging
    • Jun.
    • M. A. Griswold, P. M. Jakob, R. R. Edelman, and D. K. Sodickson, “A multicoil array designed for cardiac SMASH imaging,” MAGMA, vol. 10, no. 2, pp. 105–113, Jun. 2000.
    • (2000) MAGMA , vol.10 , Issue.2 , pp. 105-113
    • Griswold, M.A.1    Jakob, P.M.2    Edelman, R.R.3    Sodickson, D.K.4
  • 5
    • 0036137464 scopus 로고    scopus 로고
    • Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI
    • Jan.
    • D. K. Sodickson, C. A. McKenzie, M. A. Ohliger, E. N. Yeh, and M. D. Price, “Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI,” MAGMA, vol. 13, no. 3, pp. 158–163, Jan. 2002.
    • (2002) MAGMA , vol.13 , Issue.3 , pp. 158-163
    • Sodickson, D.K.1    McKenzie, C.A.2    Ohliger, M.A.3    Yeh, E.N.4    Price, M.D.5
  • 6
    • 7544231110 scopus 로고    scopus 로고
    • Parallel imaging performance as a function of field strength-an experimental investigation using electrodynamic scaling
    • Nov.
    • F. Wiesinger, P. F. Van de Moortele, G. Adriany, N. De Zanche, K. Ugurbil, and K. P. Pruessmann, “Parallel imaging performance as a function of field strength-an experimental investigation using electrodynamic scaling,” Magn. Reson. Med., vol. 52, no. 5, pp. 953–964, Nov. 2004.
    • (2004) Magn. Reson. Med. , vol.52 , Issue.5 , pp. 953-964
    • Wiesinger, F.1    Van de Moortele, P.F.2    Adriany, G.3    De Zanche, N.4    Ugurbil, K.5    Pruessmann, K.P.6
  • 7
    • 0242304636 scopus 로고    scopus 로고
    • Ultra-high frequency array performance: Predicted effects of dielectric resonance
    • P. J. Ledden and J. H. Duyn, “Ultra-high frequency array performance: Predicted effects of dielectric resonance,” in Proc. 10th Annu. Meeting ISMRM, 2002, p. 324.
    • (2002) Proc. 10th Annu. Meeting ISMRM , pp. 324
    • Ledden, P.J.1    Duyn, J.H.2
  • 9
    • 0034845550 scopus 로고    scopus 로고
    • Microstrip RF surface coil design for extremely high-field MRI and spectroscopy
    • Sep.
    • X. Zhang, K. Ugurbil, and W. Chen, “Microstrip RF surface coil design for extremely high-field MRI and spectroscopy,” Magn. Reson. Med., vol. 46, no. 3, pp. 443–450, Sep. 2001.
    • (2001) Magn. Reson. Med. , vol.46 , Issue.3 , pp. 443-450
    • Zhang, X.1    Ugurbil, K.2    Chen, W.3
  • 10
    • 0038150142 scopus 로고    scopus 로고
    • A microstrip transmission line volume oil for human head MR imaging at 4T
    • Apr.
    • X. Zhang, K. Ugurbil, and W. Chen, “A microstrip transmission line volume oil for human head MR imaging at 4T,” J. Magn. Reson., vol. 161, no. 2, pp. 242–251, Apr. 2003.
    • (2003) J. Magn. Reson. , vol.161 , Issue.2 , pp. 242-251
    • Zhang, X.1    Ugurbil, K.2    Chen, W.3
  • 11
    • 14844304417 scopus 로고    scopus 로고
    • An inverted-microstrip resonator for human head proton MR imaging at 7 tesla
    • Mar.
    • X. Zhang, K. Ugurbil, R. Sainati, and W. Chen, “An inverted-microstrip resonator for human head proton MR imaging at 7 tesla,” IEEE Trans. Biomed. Eng., vol. 52, no. 3, pp. 495–504, Mar. 2005.
    • (2005) IEEE Trans. Biomed. Eng. , vol.52 , Issue.3 , pp. 495-504
    • Zhang, X.1    Ugurbil, K.2    Sainati, R.3    Chen, W.4
  • 12
    • 18244397214 scopus 로고    scopus 로고
    • Higher-order harmonic transmission-line RF coil design for MR applications
    • May
    • X. Zhang, X. H. Zhu, and W. Chen, “Higher-order harmonic transmission-line RF coil design for MR applications,” Magn. Reson. Med., vol. 53, no. 5, pp. 1234–1239, May 2005.
    • (2005) Magn. Reson. Med. , vol.53 , Issue.5 , pp. 1234-1239
    • Zhang, X.1    Zhu, X.H.2    Chen, W.3
  • 13
    • 34248393114 scopus 로고    scopus 로고
    • Interconnecting L/C components for decoupling and its application to the low-field open MRI array
    • B. Wu, P. Qu, C. Wang, J. Yuan, and G. X. Shen, “Interconnecting L/C components for decoupling and its application to the low-field open MRI array,” Magn. Reson. Eng., vol. 31B, pp. 116–126, 2007.
    • (2007) Magn. Reson. Eng. , vol.31 B , pp. 116-126
    • Wu, B.1    Qu, P.2    Wang, C.3    Yuan, J.4    Shen, G.X.5
  • 14
    • 33947177194 scopus 로고    scopus 로고
    • Tunable loop microstrip (TLM) coil array with decoupling capacitors
    • B. Wu, P. Qu, J. Yuan, and G. X. Shen, “Tunable loop microstrip (TLM) coil array with decoupling capacitors,” in Proc. 13th Annu. Meeting ISMRM, 2005, p. 949.
    • (2005) Proc. 13th Annu. Meeting ISMRM , pp. 949
    • Wu, B.1    Qu, P.2    Yuan, J.3    Shen, G.X.4
  • 15
    • 33747885067 scopus 로고    scopus 로고
    • Design of an inductively decoupled microstrip array at 9.4 T
    • Sep.
    • B. Wu, X. Zhang, P. Qu, and G. X. Shen, “Design of an inductively decoupled microstrip array at 9.4 T,” J. Magn. Reson., vol. 182, no. 1, pp. 126–132, Sep. 2006.
    • (2006) J. Magn. Reson. , vol.182 , Issue.1 , pp. 126-132
    • Wu, B.1    Zhang, X.2    Qu, P.3    Shen, G.X.4
  • 16
    • 33947101479 scopus 로고    scopus 로고
    • Capacitively decoupled tunable loop microstrip (TLM) array at 7 T
    • Apr.
    • B. Wu, X. Zhang, P. Qu, and G. X. Shen, “Capacitively decoupled tunable loop microstrip (TLM) array at 7 T,” Magn. Reson. Imag., vol. 25, no. 3, pp. 418–424, Apr. 2007.
    • (2007) Magn. Reson. Imag. , vol.25 , Issue.3 , pp. 418-424
    • Wu, B.1    Zhang, X.2    Qu, P.3    Shen, G.X.4
  • 17
    • 0026340831 scopus 로고
    • Electromagnetic fields of surface coil in vivo NMR at high frequencies
    • Dec.
    • J. R. Keltner, J. W. Carlson, M. S. Roos, S. T. Wong, T. L. Wong, and T. F. Budinger, “Electromagnetic fields of surface coil in vivo NMR at high frequencies,” Magn. Reson. Med., vol. 22, no. 2, pp. 467–480, Dec. 1991.
    • (1991) Magn. Reson. Med. , vol.22 , Issue.2 , pp. 467-480
    • Keltner, J.R.1    Carlson, J.W.2    Roos, M.S.3    Wong, S.T.4    Wong, T.L.5    Budinger, T.F.6
  • 18
    • 0000714697 scopus 로고    scopus 로고
    • A novel method to reduce the signal coupling of surface coils for MRI
    • J. Wang, “A novel method to reduce the signal coupling of surface coils for MRI,” in Proc. 4th Annu. Meeting ISMRM, 1996, p. 1434.
    • (1996) Proc. 4th Annu. Meeting ISMRM , pp. 1434
    • Wang, J.1
  • 21
    • 15844396465 scopus 로고    scopus 로고
    • Tailored utilization of acquired k-space points for GRAPPA reconstruction
    • May
    • P. Qu, G. X. Shen, C. Wang, B. Wu, and J. Yuan, “Tailored utilization of acquired k-space points for GRAPPA reconstruction,” J. Magn. Reson., vol. 174, no. 1, pp. 60–67, May 2005.
    • (2005) J. Magn. Reson. , vol.174 , Issue.1 , pp. 60-67
    • Qu, P.1    Shen, G.X.2    Wang, C.3    Wu, B.4    Yuan, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.