메뉴 건너뛰기




Volumn 56, Issue 3, 2006, Pages 563-571

Rapid 3D-T1p mapping of the knee joint at 3.0T with parallel imaging

Author keywords

3.0T; GRAPPA; Knee joint; Parallel imaging; Spin lattice relaxation time in the rotating frame (T1p)

Indexed keywords

MUSCLE; PHANTOMS; RELAXATION TIME; SPIN-LATTICE RELAXATION;

EID: 33748352137     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.20982     Document Type: Article
Times cited : (57)

References (26)
  • 1
    • 0033819767 scopus 로고    scopus 로고
    • Magnetic resonance imaging of articular cartilage and evaluation of cartilage disease
    • Trattnig S, Mlynarik V, Huber M, Ba-Ssalamah A, Puig S, Imhof H. Magnetic resonance imaging of articular cartilage and evaluation of cartilage disease. Invest Radiol 2000;35:595-601.
    • (2000) Invest Radiol , vol.35 , pp. 595-601
    • Trattnig, S.1    Mlynarik, V.2    Huber, M.3    Ba-Ssalamah, A.4    Puig, S.5    Imhof, H.6
  • 2
    • 0033810343 scopus 로고    scopus 로고
    • MRI techniques in early stages of cartilage disease
    • Burstein D, Bashir A, Gray ML. MRI techniques in early stages of cartilage disease. Invest Radiol 2000;35:622-638.
    • (2000) Invest Radiol , vol.35 , pp. 622-638
    • Burstein, D.1    Bashir, A.2    Gray, M.L.3
  • 3
    • 0033820015 scopus 로고    scopus 로고
    • Anatomy, biochemistry, and physiology of articular cartilage
    • Huber M, Trattnig S, Lintner F. Anatomy, biochemistry, and physiology of articular cartilage. Invest Radiol 2000;35:573-580.
    • (2000) Invest Radiol , vol.35 , pp. 573-580
    • Huber, M.1    Trattnig, S.2    Lintner, F.3
  • 5
    • 0036007480 scopus 로고    scopus 로고
    • 23Na MRI accurately measures fixed charge density in articular cartilage
    • Shapiro EM, Borthakur A, Gougoutas AJ, Reddy R. 23Na MRI accurately measures fixed charge density in articular cartilage. Magn Reson Med 2002;47:284-291.
    • (2002) Magn Reson Med , vol.47 , pp. 284-291
    • Shapiro, E.M.1    Borthakur, A.2    Gougoutas, A.J.3    Reddy, R.4
  • 12
    • 0002403563 scopus 로고    scopus 로고
    • Spatial encoding using multiple RF coils: SMASH imaging and parallel MRI
    • New York: John Wiley & Sons Ltd
    • Sodickson DK. Spatial encoding using multiple RF coils: SMASH imaging and parallel MRI. Methods in biomedical magnetic resonance imaging and spectroscopy. New York: John Wiley & Sons Ltd; 2000. p 239-250.
    • (2000) Methods in Biomedical Magnetic Resonance Imaging and Spectroscopy , pp. 239-250
    • Sodickson, D.K.1
  • 14
    • 24144462588 scopus 로고    scopus 로고
    • Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T
    • Wang Z, Wang J, Connick TJ, Wetmore GS, Detre JA. Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T. Magn Reson Med 2005;54:732-737.
    • (2005) Magn Reson Med , vol.54 , pp. 732-737
    • Wang, Z.1    Wang, J.2    Connick, T.J.3    Wetmore, G.S.4    Detre, J.A.5
  • 15
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 20
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Henkelman RM. Measurement of signal intensities in the presence of noise in MR images. Med Phys 1985;12:232-233.
    • (1985) Med Phys , vol.12 , pp. 232-233
    • Henkelman, R.M.1
  • 21
    • 24144470505 scopus 로고    scopus 로고
    • Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: Application with cardiac imaging and a 32-channel cardiac coil
    • Reeder SB, Wintersperger BJ, Dietrich O, Lanz T, Greiser A, Reiser MF, Glazer GM, Schoenberg SO. Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: application with cardiac imaging and a 32-channel cardiac coil. Magn Reson Med 2005;54:748-754.
    • (2005) Magn Reson Med , vol.54 , pp. 748-754
    • Reeder, S.B.1    Wintersperger, B.J.2    Dietrich, O.3    Lanz, T.4    Greiser, A.5    Reiser, M.F.6    Glazer, G.M.7    Schoenberg, S.O.8
  • 23
    • 0032252606 scopus 로고    scopus 로고
    • 1 field distributions in a heterogenous human head model within a birdcage coil
    • 1 field distributions in a heterogenous human head model within a birdcage coil. Magn Reson Med 1998;40:847-856.
    • (1998) Magn Reson Med , vol.40 , pp. 847-856
    • Collins, M.C.1    Li, S.2    Smith, M.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.