메뉴 건너뛰기




Volumn 31, Issue 2, 2012, Pages 131-140

Advances in patch clamp technique: Towards higher quality and quantity

Author keywords

Action potential clamp; Automated patch clamp; Cell type transforming clamp; Dynamic clamp; Highresolution scanning patch clamp

Indexed keywords

CALCIUM CHANNEL L TYPE; SODIUM CHANNEL;

EID: 84862547610     PISSN: 02315882     EISSN: 13384325     Source Type: Journal    
DOI: 10.4149/gpb_2012_016     Document Type: Review
Times cited : (55)

References (38)
  • 1
    • 72149100513 scopus 로고    scopus 로고
    • Anthropomorphizing the mouse cardiac action potential via a novel dynamic clamp method
    • Ahrens-Nicklas R. C., Christini D. J. (2009): Anthropomorphizing the mouse cardiac action potential via a novel dynamic clamp method. Biophys. J. 97, 2684-2692 http://dx.doi.org/10.1016/j.bpj.2009.09.002
    • (2009) Biophys. J. , vol.97 , pp. 2684-2692
    • Ahrens-Nicklas, R.C.1    Christini, D.J.2
  • 2
    • 79551587546 scopus 로고    scopus 로고
    • Sequential dissection of multiple ionic currents in single cardiac myocytes under action potential-clamp
    • Banyasz T., Horvath B., Jian Z., Izu L. T., Chen-Izu Y. (2011): Sequential dissection of multiple ionic currents in single cardiac myocytes under action potential-clamp. J. Mol. Cell. Cardiol. 50, 578-581 http://dx.doi.org/10.1016/j.yjmcc.2010.12.020
    • (2011) J. Mol. Cell. Cardiol. , vol.50 , pp. 578-581
    • Banyasz, T.1    Horvath, B.2    Jian, Z.3    Izu, L.T.4    Chen-Izu, Y.5
  • 4
    • 33644872207 scopus 로고    scopus 로고
    • Long-QT syndrome-related sodium channel mutations probed by the dynamic action potential clamp technique
    • Berecki G., Zegers J. G., Bhuiyan Z. A., Verkerk A. O., Wilders R., van Ginneken A. C. (2006): Long-QT syndrome-related sodium channel mutations probed by the dynamic action potential clamp technique. J. Physiol. 570, 237-250
    • (2006) J. Physiol. , vol.570 , pp. 237-250
    • Berecki, G.1    Zegers, J.G.2    Bhuiyan, Z.A.3    Verkerk, A.O.4    Wilders, R.5    Van Ginneken, A.C.6
  • 5
    • 58149252470 scopus 로고    scopus 로고
    • Cardiac channelopathies studied with the dynamic action potential-clamp technique
    • Berecki G., Zegers J. G., Wilders R., Van Ginneken A. C. (2007): Cardiac channelopathies studied with the dynamic action potential-clamp technique. Methods. Mol. Biol. 403, 233-250 http://dx.doi.org/10.1007/978-1-59745-529-9-16
    • (2007) Methods. Mol. Biol. , vol.403 , pp. 233-250
    • Berecki, G.1    Zegers, J.G.2    Wilders, R.3    Van Ginneken, A.C.4
  • 6
    • 79953716794 scopus 로고    scopus 로고
    • Pharmacological studies of Cav3.1 T-type calcium channels using automated patch-clamp techniques
    • Choi K. H., Song C., Cheong C. S., Rhim H. (2011): Pharmacological studies of Cav3.1 T-type calcium channels using automated patch-clamp techniques. Gen. Physiol. Biophys. 30, 100-105 http://dx.doi.org/10.4149/gpb- 2011-01-100
    • (2011) Gen. Physiol. Biophys. , vol.30 , pp. 100-105
    • Choi, K.H.1    Song, C.2    Cheong, C.S.3    Rhim, H.4
  • 7
    • 77953697090 scopus 로고    scopus 로고
    • Targeting ion channels for drug discovery
    • Clare J. J. (2010): Targeting ion channels for drug discovery. Discov. Med. 9, 253-260
    • (2010) Discov. Med. , vol.9 , pp. 253-260
    • Clare, J.J.1
  • 8
    • 78149409405 scopus 로고    scopus 로고
    • Excitation-contraction coupling in human heart failure examined by action potential clamp in rat cardiac myocytes
    • Cooper P. J., Soeller C., Cannell M. B. (2010): Excitation-contraction coupling in human heart failure examined by action potential clamp in rat cardiac myocytes. J. Mol. Cell. Cardiol. 49, 911-917 http://dx.doi.org/10.1016/ j.yjmcc.2010.04.012
    • (2010) J. Mol. Cell. Cardiol. , vol.49 , pp. 911-917
    • Cooper, P.J.1    Soeller, C.2    Cannell, M.B.3
  • 9
    • 34548856200 scopus 로고    scopus 로고
    • Population patch clamp electrophysiology: A breakthrough technology for ion channel screening
    • Dale T. J., Townsend C., Hollands E. C., Trezise D. J. (2007): Population patch clamp electrophysiology: a breakthrough technology for ion channel screening. Mol. Biosyst. 3, 714-722 http://dx.doi.org/10.1039/b706152h
    • (2007) Mol. Biosyst. , vol.3 , pp. 714-722
    • Dale, T.J.1    Townsend, C.2    Hollands, E.C.3    Trezise, D.J.4
  • 10
    • 0000954302 scopus 로고
    • A contribution to the theory of permeability of thin films
    • Danielli J. F., Davson H. (1935): A contribution to the theory of permeability of thin films. J. Cell. Comp. Physiol. 5, 495-508 http://dx.doi.org/10.1002/jcp. 1030050409
    • (1935) J. Cell. Comp. Physiol. , vol.5 , pp. 495-508
    • Danielli, J.F.1    Davson, H.2
  • 11
    • 0025364711 scopus 로고
    • Ionic currents contributing to the action potential in single ventricular myocytes of the guinea pig studied with action potential clamp
    • Doerr T., Denger R., Doerr A., Trautwein W. (1990): Ionic currents contributing to the action potential in single ventricular myocytes of the guinea pig studied with action potential clamp. Pflügers. Arch. 416, 230-237 http://dx.doi.org/10.1007/BF00392058
    • (1990) Pflügers. Arch. , vol.416 , pp. 230-237
    • Doerr, T.1    Denger, R.2    Doerr, A.3    Trautwein, W.4
  • 12
    • 0024601835 scopus 로고
    • Calcium currents in single SA nodal cells of the rabbit heart studied with action potential clamp
    • Doerr T., Denger R., Trautwein W. (1989): Calcium currents in single SA nodal cells of the rabbit heart studied with action potential clamp. Pflügers. Arch. 413, 599-603 http://dx.doi.org/10.1007/BF00581808
    • (1989) Pflügers. Arch. , vol.413 , pp. 599-603
    • Doerr, T.1    Denger, R.2    Trautwein, W.3
  • 13
    • 33746835692 scopus 로고    scopus 로고
    • Effectofsimulated I (to) on guinea pig and canine ventricular action potential morphology
    • Dong M., Sun X., Prinz A. A., Wang H. S. (2006): Effectofsimulated I (to) on guinea pig and canine ventricular action potential morphology. Am. J. Physiol. Heart. Circ. Physiol. 291, H631-637 http://dx.doi.org/10.1152/ajpheart. 00084.2006
    • (2006) Am. J. Physiol. Heart. Circ. Physiol. , vol.291
    • Dong, M.1    Sun, X.2    Prinz, A.A.3    Wang, H.S.4
  • 14
    • 77249162193 scopus 로고    scopus 로고
    • Dynamic clamp: Alteration of response properties and creation of virtual realities in neurophysiology
    • Economo M. N., Fernandez F. R., White J. A. (2010): Dynamic clamp: alteration of response properties and creation of virtual realities in neurophysiology. J. Neurosci. 30, 2407-2413 http://dx.doi.org/10.1523/JNEUROSCI. 5954-09.2010
    • (2010) J. Neurosci. , vol.30 , pp. 2407-2413
    • Economo, M.N.1    Fernandez, F.R.2    White, J.A.3
  • 17
    • 0024604960 scopus 로고
    • The scanning ion-conductance microscope
    • Hansma P. K., Drake B., Marti O., Gould S. A., Prater C. B. (1989): The scanning ion-conductance microscope. Science 243, 641-643 http://dx.doi.org/10. 1126/science.2464851
    • (1989) Science , vol.243 , pp. 641-643
    • Hansma, P.K.1    Drake, B.2    Marti, O.3    Gould, S.A.4    Prater, C.B.5
  • 18
    • 33750854829 scopus 로고    scopus 로고
    • Conduction between isolated rabbit Purkinje and ventricular myocytes coupled by a variable resistence
    • Huelsing D. J., Spitzer K. W., Cordeiro J. M., Pollard A. E. (1998): Conduction between isolated rabbit Purkinje and ventricular myocytes coupled by a variable resistence. Am. J. Physiol. 274, H1163-1173
    • (1998) Am. J. Physiol. , vol.274
    • Huelsing, D.J.1    Spitzer, K.W.2    Cordeiro, J.M.3    Pollard, A.E.4
  • 19
    • 35649001607 scopus 로고
    • A Quantitative Description of Membrane Currentand Its Application to Conduction and Excitiation in Nerve
    • Huxley A. F., Hodgkin A. L. (1952): A Quantitative Description of Membrane Currentand Its Application to Conduction and Excitiation in Nerve. J. Physiol. 1, 500-544
    • (1952) J. Physiol. , vol.1 , pp. 500-544
    • Huxley, A.F.1    Hodgkin, A.L.2
  • 20
    • 77956636381 scopus 로고    scopus 로고
    • Measurement of cellular excitability by whole cell patch clamp technique
    • Karmažínová M., Lacinová L. (2010): Measurement of cellular excitability by whole cell patch clamp technique. Physiol. Res. 59, S1-7
    • (2010) Physiol. Res. , vol.59
    • Karmažínová, M.1    Lacinová, L.2
  • 21
    • 0037178198 scopus 로고    scopus 로고
    • Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells
    • Klemic K. G., Klemic J. F., Reed M. A., Sigworth F. J. (2002): Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells. Biosens. Bioelectron. 17, 597-604 http://dx.doi.org/10.1016/S0956-5663 (02) 00015-5
    • (2002) Biosens. Bioelectron. , vol.17 , pp. 597-604
    • Klemic, K.G.1    Klemic, J.F.2    Reed, M.A.3    Sigworth, F.J.4
  • 22
    • 0016818038 scopus 로고
    • Effect of internal fluoride and phosphate on membrane currents during intracellular dialysis of nerve cells
    • Kostyuk P. G., Krishtal O. A., Pidoplichko V. I. (1975): Effect of internal fluoride and phosphate on membrane currents during intracellular dialysis of nerve cells. Nature. 257, 691-693 http://dx.doi.org/10.1038/257691a0
    • (1975) Nature. , vol.257 , pp. 691-693
    • Kostyuk, P.G.1    Krishtal, O.A.2    Pidoplichko, V.I.3
  • 23
    • 84892794173 scopus 로고
    • The normal membrane potential of frog sartorius fibers
    • Ling G., Gerard R. W. (1949): The normal membrane potential of frog sartorius fibers. J. Cell. Physiol. 34, 383-396 http://dx.doi.org/10.1002/jcp. 1030340304
    • (1949) J. Cell. Physiol. , vol.34 , pp. 383-396
    • Ling, G.1    Gerard, R.W.2
  • 25
    • 33645780149 scopus 로고    scopus 로고
    • QPatch: The past, present and future of automated patch clamp
    • Mathes C. (2006): QPatch: the past, present and future of automated patch clamp. Expert. Opin. Ther. Targets. 10, 319-327 http://dx.doi.org/10.1517/ 14728222.10.2.319
    • (2006) Expert. Opin. Ther. Targets. , vol.10 , pp. 319-327
    • Mathes, C.1
  • 26
    • 0017258698 scopus 로고
    • Single channel currents recorded from membrane of denervated frog muscle fibers
    • Neher E., Sakmann B. (1976): Single channel currents recorded from membrane of denervated frog muscle fibers. Nature. (Lond.) 260, 799-802 http://dx.doi.org/10.1038/260799a0
    • (1976) Nature. (Lond.) , vol.260 , pp. 799-802
    • Neher, E.1    Sakmann, B.2
  • 27
    • 0004516579 scopus 로고
    • Patch clamp techniques for single channel and whole-cell recording
    • 2nd edition. The Company of Biologists Ltd., Cambridge
    • Ogden D., Stanfield P. (1994): Patch clamp techniques for single channel and whole-cell recording. In: Microelectrode Techniques (2nd edition). The Company of Biologists Ltd., Cambridge
    • (1994) Microelectrode Techniques
    • Ogden, D.1    Stanfield, P.2
  • 28
    • 0032527229 scopus 로고    scopus 로고
    • Animal electricity and the birth of electrophysiology: The legacy of Luigi Galvani
    • Piccolino M. (1998): Animal electricity and the birth of electrophysiology: the legacy of Luigi Galvani. Brain. Res. Bull. 46, 381-407 http://dx.doi.org/10.1016/S0361-9230 (98) 00026-4
    • (1998) Brain. Res. Bull. , vol.46 , pp. 381-407
    • Piccolino, M.1
  • 29
    • 80555130144 scopus 로고    scopus 로고
    • Introduction of a Modular Automated Voltage-Clamp Platform and Its Correlation with Manual Human Ether-à-go-go Related Gene Voltage-Clamp Data
    • Scheel O., Himmel H., Rascher-Eggstein G., Knott T. (2011): Introduction of a Modular Automated Voltage-Clamp Platform and Its Correlation with Manual Human Ether-à-go-go Related Gene Voltage-Clamp Data. Assay. Drug. Dev. Technol. 9, 600-607 http://dx.doi.org/10.1089/adt.2010.0352
    • (2011) Assay. Drug. Dev. Technol. , vol.9 , pp. 600-607
    • Scheel, O.1    Himmel, H.2    Rascher-Eggstein, G.3    Knott, T.4
  • 30
    • 1542283861 scopus 로고
    • Stimulation simulations of young yet cultured beating hearts (PhD thesis)
    • Scott S. (1979): Stimulation simulations of young yet cultured beating hearts (PhD thesis). State University of New York at Buffalo
    • (1979) State University of New York at Buffalo
    • Scott, S.1
  • 33
    • 0034084758 scopus 로고    scopus 로고
    • Injury current modulates aferdepolarizations in single human ventricular cells
    • Verkerk A. O., Veldkamp M. W., de Jonge N., Wilders R., van Ginneken A. C. (2000): Injury current modulates aferdepolarizations in single human ventricular cells. Cardiovasc. Res. 47, 124-132 http://dx.doi.org/10.1016/S0008- 6363 (00) 00064-X
    • (2000) Cardiovasc. Res. , vol.47 , pp. 124-132
    • Verkerk, A.O.1    Veldkamp, M.W.2    De Jonge, N.3    Wilders, R.4    Van Ginneken, A.C.5
  • 34
    • 84555186707 scopus 로고    scopus 로고
    • Understanding of molecular substructures that contribute to hERG K (+) channel blockade: Synthesis and biological evaluation of E-4031 analogues
    • Vilums M., Overman J., Klaasse E., Scheel O., Brussee J., Ijzerman A. P. (2012): Understanding of molecular substructures that contribute to hERG K (+) channel blockade: synthesis and biological evaluation of E-4031 analogues. ChemMedChem. 7, 107-113 http://dx.doi.org/10.1002/cmdc.201100366
    • (2012) ChemMedChem. , vol.7 , pp. 107-113
    • Vilums, M.1    Overman, J.2    Klaasse, E.3    Scheel, O.4    Brussee, J.5    Ijzerman, A.P.6
  • 36
    • 0028807627 scopus 로고
    • Modulation of pacemaker activity of sinoatrial node cells by electrical load imposed by an atrial cell model
    • Watanabe E. I., Honjo H., Anno T., Boyett M. R., Kodama I., Toyama J. (1995): Modulation of pacemaker activity of sinoatrial node cells by electrical load imposed by an atrial cell model. Am. J. Physiol. 269, H1735-1742
    • (1995) Am. J. Physiol. , vol.269
    • Watanabe, E.I.1    Honjo, H.2    Anno, T.3    Boyett, M.R.4    Kodama, I.5    Toyama, J.6
  • 37
    • 33749406125 scopus 로고    scopus 로고
    • Dynamic clamp: A powerful tool in cardiac electrophysiology
    • Wilders R. (2006): Dynamic clamp: a powerful tool in cardiac electrophysiology. J. Physiol. 576, 349-359 http://dx.doi.org/10.1113/jphysiol. 2006.115840
    • (2006) J. Physiol. , vol.576 , pp. 349-359
    • Wilders, R.1
  • 38
    • 84862521849 scopus 로고    scopus 로고
    • Highresolution patch-clamp technique based on feedback control of scanning ion conductance microscopy
    • Chinese
    • Yang X., Liu X., Zhang X. F., Lu H. J., Zhang Y. J. (2010): Highresolution patch-clamp technique based on feedback control of scanning ion conductance microscopy. Sheng. Li. Xue. Bao. 62, 275-283 (in Chinese)
    • (2010) Sheng. Li. Xue. Bao. , vol.62 , pp. 275-283
    • Yang, X.1    Liu, X.2    Zhang, X.F.3    Lu, H.J.4    Zhang, Y.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.