메뉴 건너뛰기




Volumn , Issue , 2012, Pages 71-81

Multi-source energy harvesting power generators for instrumented implants: Towards the development of a smart hip prosthesis

Author keywords

Biomedical implants; Electric bio generator; Energy harvesting; Self powered systems; Smart hip prosthesis

Indexed keywords

ANGULAR MOVEMENTS; BIOMEDICAL IMPLANTS; ELECTRIC BIO-GENERATOR; ELECTRIC POWER SUPPLY; ENERGY SOURCE; FEMORAL COMPONENT; FLEXION-EXTENSION; HIP IMPLANTS; IMPLANT LOOSENING; INSTRUMENTED IMPLANT; MOVEMENT-BASED; MULTISOURCES; PIEZOELECTRIC ENERGY; ROTATION AXES; SELF-POWERED SYSTEMS; SINUSOIDAL FUNCTIONS;

EID: 84861981186     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (5)

References (36)
  • 2
    • 33846077160 scopus 로고    scopus 로고
    • Energy harvesting vibration sources for microsystems applications
    • Beeby, S., Tudor, M., and White, N. (2006). Energy harvesting vibration sources for microsystems applications. Measurement Science and Technology, 17:R175-R195.
    • (2006) Measurement Science and Technology , vol.17
    • Beeby, S.1    Tudor, M.2    White, N.3
  • 5
    • 56449115420 scopus 로고    scopus 로고
    • Powering mems portable devices a review of non-regenerative and regenerative power supply systems with special emphasis on piezoelectric energy harvesting systems
    • Cook-Chennault, K., Thambi, N., and Sastry, A. (2008). Powering mems portable devices a review of non-regenerative and regenerative power supply systems with special emphasis on piezoelectric energy harvesting systems. Smart Materials and Structures, 17:1-33.
    • (2008) Smart Materials and Structures , vol.17 , pp. 1-33
    • Cook-Chennault, K.1    Thambi, N.2    Sastry, A.3
  • 7
    • 33644749219 scopus 로고    scopus 로고
    • Design considerations for mems-scale piezoelectric mechanical vibration energy harvesters
    • duToit, N., Wardle, B., and Kim, S. (2005). Design considerations for mems-scale piezoelectric mechanical vibration energy harvesters. Integrated Ferroelectrics, 71:121-160.
    • (2005) Integrated Ferroelectrics , vol.71 , pp. 121-160
    • DuToit, N.1    Wardle, B.2    Kim, S.3
  • 8
    • 77950692226 scopus 로고    scopus 로고
    • Polymeric piezoelectric actuator substrate for osteoblast mechanical stimulation
    • Frias, C., Reis, J., e Silva, F. C., Potes, J., Simões, J., and Marques, A. (2010). Polymeric piezoelectric actuator substrate for osteoblast mechanical stimulation. Journal of Biomechanics, 43:1061-1066.
    • (2010) Journal of Biomechanics , vol.43 , pp. 1061-1066
    • Frias, C.1    Reis, J.2    Silva, F.C.3    Potes, J.4    Simões, J.5    Marques, A.6
  • 9
    • 54249139101 scopus 로고    scopus 로고
    • Comparison of energy harvesting systems for wireless sensor networks
    • Gilbert, J. and Balouchi, F. (2008). Comparison of energy harvesting systems for wireless sensor networks. International Journal of Automation and Computing, 5(4):334-347.
    • (2008) International Journal of Automation and Computing , vol.5 , Issue.4 , pp. 334-347
    • Gilbert, J.1    Balouchi, F.2
  • 10
    • 0033213747 scopus 로고    scopus 로고
    • Hip endoprosthesis for in vivo measurement of joint force and temperature
    • Graichen, F., Bergmann, G., and Rohlmann, A. (1999). Hip endoprosthesis for in vivo measurement of joint force and temperature. Journal of Biomechanics, 32:1113-1117.
    • (1999) Journal of Biomechanics , vol.32 , pp. 1113-1117
    • Graichen, F.1    Bergmann, G.2    Rohlmann, A.3
  • 12
    • 62949229183 scopus 로고    scopus 로고
    • ESB clinical biomechanics award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 610 months
    • Heinlein, B., Kutzner, I., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., and Bergmann, G. (2009). ESB clinical biomechanics award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 610 months. Clinical Biomechanics, 24:315-326.
    • (2009) Clinical Biomechanics , vol.24 , pp. 315-326
    • Heinlein, B.1    Kutzner, I.2    Graichen, F.3    Bender, A.4    Rohlmann, A.5    Halder, A.6    Beier, A.7    Bergmann, G.8
  • 14
    • 0033686465 scopus 로고    scopus 로고
    • Applications of artificial neural-networks for energy systems
    • Kalogirou, S. (2000). Applications of artificial neural-networks for energy systems. Applied Energy, 67:17-35.
    • (2000) Applied Energy , vol.67 , pp. 17-35
    • Kalogirou, S.1
  • 17
    • 34147150632 scopus 로고    scopus 로고
    • Projections of primary and revision hip and knee arthroplasty in the united states from 2005 to 2030
    • Kurtz, S., Ong, K., Lau, E., Mowat, F., and Halpern, M. (2007). Projections of primary and revision hip and knee arthroplasty in the united states from 2005 to 2030. The Journal of Bone and Joint Surgery (American), 89(4):780-785.
    • (2007) The Journal of Bone and Joint Surgery (American) , vol.89 , Issue.4 , pp. 780-785
    • Kurtz, S.1    Ong, K.2    Lau, E.3    Mowat, F.4    Halpern, M.5
  • 19
    • 33750471202 scopus 로고    scopus 로고
    • A new hermetic antenna for wireless transmission systems of implantable medical devices
    • Marcelli, E., Scalambraa, F., Cercenelli, L., and Plicchi, G. (2007). A new hermetic antenna for wireless transmission systems of implantable medical devices. Medical Engineering & Physics, 29:140-147.
    • (2007) Medical Engineering & Physics , vol.29 , pp. 140-147
    • Marcelli, E.1    Scalambraa, F.2    Cercenelli, L.3    Plicchi, G.4
  • 27
    • 57349160304 scopus 로고    scopus 로고
    • On the optimal energy harvesting from a vibration source
    • Renno, J., Daqaq, M., and Inman, D. (2009). On the optimal energy harvesting from a vibration source. Journal of Sound and Vibration, 320:386-405.
    • (2009) Journal of Sound and Vibration , vol.320 , pp. 386-405
    • Renno, J.1    Daqaq, M.2    Inman, D.3
  • 28
    • 38649133200 scopus 로고    scopus 로고
    • Loads on a telemeterized vertebral body replacement measured in three patients within the first postoperative month
    • Rohlmann, A., Graichen, F., Bender, A., Kayser, R., and Bergmann, G. (2008). Loads on a telemeterized vertebral body replacement measured in three patients within the first postoperative month. Clinical Biomechanics, 23:147-158.
    • (2008) Clinical Biomechanics , vol.23 , pp. 147-158
    • Rohlmann, A.1    Graichen, F.2    Bender, A.3    Kayser, R.4    Bergmann, G.5
  • 29
    • 39849097996 scopus 로고    scopus 로고
    • Bone vibration measurement using ultrasound: Application to detection of hip prosthesis loosening
    • Rowlands, A., Duck, F., and Cunningham, J. (2008). Bone vibration measurement using ultrasound: Application to detection of hip prosthesis loosening. Medical Engineering & Physics, 30:278-284.
    • (2008) Medical Engineering & Physics , vol.30 , pp. 278-284
    • Rowlands, A.1    Duck, F.2    Cunningham, J.3
  • 32
    • 43249130718 scopus 로고    scopus 로고
    • Power sources and electrical recharging strategies for implantable medical devices
    • Wei, X. and Liu, J. (2008). Power sources and electrical recharging strategies for implantable medical devices. Frontiers of Energy and Power Engineering in China, 2(1):1-13.
    • (2008) Frontiers of Energy and Power Engineering in China , vol.2 , Issue.1 , pp. 1-13
    • Wei, X.1    Liu, J.2
  • 33
    • 59049084708 scopus 로고    scopus 로고
    • An instrumented implant for in vivo measurement of contact forces and contact moments in the shoulder joint
    • Westerhoff, P., Graichen, F., Bender, A., Rohlmann, A., and Bergmann, G. (2009). An instrumented implant for in vivo measurement of contact forces and contact moments in the shoulder joint. Medical Engineering & Physics, 31:207-213.
    • (2009) Medical Engineering & Physics , vol.31 , pp. 207-213
    • Westerhoff, P.1    Graichen, F.2    Bender, A.3    Rohlmann, A.4    Bergmann, G.5
  • 36
    • 75649083069 scopus 로고    scopus 로고
    • Strategies for increasing the operating frequency range of vibration energy harvesters: A review
    • Zhu, D., Tudor, M., and Beeby, S. (2010). Strategies for increasing the operating frequency range of vibration energy harvesters: a review. Measurement Science and Technology, 21:1-29.
    • (2010) Measurement Science and Technology , vol.21 , pp. 1-29
    • Zhu, D.1    Tudor, M.2    Beeby, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.