Volumn 32, Issue 10, 1999, Pages 1113-1117

Hip endoprosthesis for in vivo measurement of joint force and temperature

Author keywords

Biomechanics; Hip joint force; Hip joint temperature; In vivo measurement; Instrumented hip prosthesis; Telemetry

Indexed keywords

BIOMECHANICS; BIOSENSORS; IMPLANTS (SURGICAL); JOINTS (ANATOMY); REAL TIME SYSTEMS; TELEMETERING; TEMPERATURE DISTRIBUTION; TEMPERATURE MEASUREMENT; TITANIUM;

EID: 0033213747     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0021-9290(99)00110-4     Document Type: Article
Times cited : (90)

References (11)
  • 2
    • 0002348321 scopus 로고
    • Instrumentation of a hip joint prosthesis
    • In: Bergmann, G., Graichen, F., Rohlmann, A. (Eds.) Forschungsvermittlung der Freien Universität, Berlin
    • Bergmann, G., Graichen, F., Rohlmann, A., 1990. Instrumentation of a hip joint prosthesis. In: Bergmann, G., Graichen, F., Rohlmann, A. (Eds.), Implantable Telemetry in Orthopaedics. Forschungsvermittlung der Freien Universität, Berlin, pp. 35-63.
    • (1990) Implantable Telemetry in Orthopaedics , pp. 35-63
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 3
    • 0009608909 scopus 로고
    • In vivo measurement of temperature rise in a hip implant
    • Orthopaedic Research Society.
    • Bergmann, G., Graichen, F., Rohlmann, A., 1991. In vivo measurement of temperature rise in a hip implant. Thirty seventh Annual Meeting, Orthopaedic Research Society.
    • (1991) Thirty seventh Annual Meeting
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 4
    • 0027641060 scopus 로고
    • Hip joint forces during walking and running, measured in two patients
    • Bergmann G., Graichen F., Rohlmann A. Hip joint forces during walking and running, measured in two patients. Journal of Biomechanics. 26:1993;969-990.
    • (1993) Journal of Biomechanics , vol.26 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 5
    • 0029294152 scopus 로고
    • Is staircase walking a risk for the fixation of hip implants?
    • Bergmann, G., Graichen, F., Rohlmann, A., 1995a. Is staircase walking a risk for the fixation of hip implants? Journal of Biomechanics, 28, 535-553.
    • (1995) Journal of Biomechanics , vol.28 , pp. 535-553
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 9
    • 0026221442 scopus 로고
    • Four-channel telemetry system for in vivo measurement of hip joint forces
    • Graichen F., Bergmann G. Four-channel telemetry system for in vivo measurement of hip joint forces. Journal of Biomedical Engineering. 13:1991;370-374.
    • (1991) Journal of Biomedical Engineering , vol.13 , pp. 370-374
    • Graichen, F.1    Bergmann, G.2
  • 10
    • 0009643978 scopus 로고
    • Inductively powered telemetry system for in vivo measurement with orthopaedic implants
    • In: Cristalli, Amlaner, Neuman (Eds.) Williamsburg, VA, USA. Biotelemetry
    • Graichen, F., Bergmann, G., Rohlmann, A., 1995. Inductively powered telemetry system for in vivo measurement with orthopaedic implants. In: Cristalli, Amlaner, Neuman (Eds.), Thirteenth International symposium on Biotelemetry, Williamsburg, VA, USA Vol. XIII. pp. 75-80. Biotelemetry
    • (1995) Thirteenth International symposium on Biotelemetry , vol.13 , pp. 75-80
    • Graichen, F.1    Bergmann, G.2    Rohlmann, A.3
  • 11
    • 0030043486 scopus 로고    scopus 로고
    • Patient monitoring system for load measurement with spinal fixation devices
    • Graichen F., Bergmann G., Rohlmann A. Patient monitoring system for load measurement with spinal fixation devices. Medicine Engineering and Physics. 18:1996;167-174.
    • (1996) Medicine Engineering and Physics , vol.18 , pp. 167-174
    • Graichen, F.1    Bergmann, G.2    Rohlmann, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.