메뉴 건너뛰기




Volumn 23, Issue 2, 2008, Pages 147-158

Loads on a telemeterized vertebral body replacement measured in three patients within the first postoperative month

Author keywords

Biomechanics; Load measurement; Spine; Telemetry; Vertebral body replacement

Indexed keywords

BENDING MOMENTS; BIOMECHANICS; FRACTURE FIXATION; PATIENT REHABILITATION; TELEMETERING;

EID: 38649133200     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2007.09.011     Document Type: Article
Times cited : (67)

References (19)
  • 1
    • 0026729555 scopus 로고
    • An improved method of stature measurement for quantitative determination of spinal loading. Application to sitting postures and whole body vibration
    • Althoff I., Brinckmann P., Frobin W., Sandover J., and Burton K. An improved method of stature measurement for quantitative determination of spinal loading. Application to sitting postures and whole body vibration. Spine 17 (1992) 682-693
    • (1992) Spine , vol.17 , pp. 682-693
    • Althoff, I.1    Brinckmann, P.2    Frobin, W.3    Sandover, J.4    Burton, K.5
  • 2
    • 38649115621 scopus 로고    scopus 로고
    • Bergmann, G., Graichen, F., Rohlmann, A., Bender, A., Ehrig, R., Westerhoff, P., Heinlein, B., in press. Design and calibration of load sensing orthopaedic implants. J. Biomech. Eng.
  • 3
    • 0020858440 scopus 로고
    • A method for measuring the load imposed on the back of a sitting person
    • Eklund J.A., Corlett E.N., and Johnson F. A method for measuring the load imposed on the back of a sitting person. Ergonomics 26 (1983) 1063-1076
    • (1983) Ergonomics , vol.26 , pp. 1063-1076
    • Eklund, J.A.1    Corlett, E.N.2    Johnson, F.3
  • 4
    • 33846669123 scopus 로고    scopus 로고
    • Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants
    • Graichen F., Arnold R., Rohlmann A., and Bergmann G. Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants. IEEE Trans. Biomed. Eng. 54 (2007) 253-261
    • (2007) IEEE Trans. Biomed. Eng. , vol.54 , pp. 253-261
    • Graichen, F.1    Arnold, R.2    Rohlmann, A.3    Bergmann, G.4
  • 5
    • 0013888190 scopus 로고
    • The load on lumbar disks in different positions of the body
    • Nachemson A. The load on lumbar disks in different positions of the body. Clin. Orthop. 45 (1966) 107-122
    • (1966) Clin. Orthop. , vol.45 , pp. 107-122
    • Nachemson, A.1
  • 6
    • 0019378565 scopus 로고
    • Disc pressure measurements
    • Nachemson A.L. Disc pressure measurements. Spine 6 (1981) 93-97
    • (1981) Spine , vol.6 , pp. 93-97
    • Nachemson, A.L.1
  • 7
    • 0029598737 scopus 로고
    • Telemeterized load measurement using instrumented spinal internal fixators in a patient with degenerative instability
    • Rohlmann A., Bergmann G., Graichen F., and Mayer H.M. Telemeterized load measurement using instrumented spinal internal fixators in a patient with degenerative instability. Spine 20 (1995) 2683-2689
    • (1995) Spine , vol.20 , pp. 2683-2689
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3    Mayer, H.M.4
  • 8
    • 0028892528 scopus 로고
    • In vivo measurement of implant loads in a patient with a fractured vertebral body
    • Rohlmann A., Bergmann G., Graichen F., and Weber U. In vivo measurement of implant loads in a patient with a fractured vertebral body. Eur. Spine J. 4 (1995) 347-353
    • (1995) Eur. Spine J. , vol.4 , pp. 347-353
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3    Weber, U.4
  • 9
    • 0032721072 scopus 로고    scopus 로고
    • Loads on internal spinal fixators measured in different body positions
    • Rohlmann A., Bergmann G., and Graichen F. Loads on internal spinal fixators measured in different body positions. Eur. Spine J. 8 (1999) 354-359
    • (1999) Eur. Spine J. , vol.8 , pp. 354-359
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3
  • 10
    • 0035918853 scopus 로고    scopus 로고
    • Comparison of intradiscal pressures and spinal fixator loads for different body positions and exercises
    • Rohlmann A., Claes L., Bergmann G., Graichen F., Neef P., and Wilke H.-J. Comparison of intradiscal pressures and spinal fixator loads for different body positions and exercises. Ergonomics 44 (2001) 781-794
    • (2001) Ergonomics , vol.44 , pp. 781-794
    • Rohlmann, A.1    Claes, L.2    Bergmann, G.3    Graichen, F.4    Neef, P.5    Wilke, H.-J.6
  • 11
    • 0036142681 scopus 로고    scopus 로고
    • Loads on an internal spinal fixation device during physical therapy
    • Rohlmann A., Graichen F., and Bergmann G. Loads on an internal spinal fixation device during physical therapy. Phys. Ther. 82 (2002) 44-52
    • (2002) Phys. Ther. , vol.82 , pp. 44-52
    • Rohlmann, A.1    Graichen, F.2    Bergmann, G.3
  • 12
    • 38649094831 scopus 로고    scopus 로고
    • Loads on an internal spinal fixation device measured in vivo
    • Lewandrowski K.U., et al. (Ed), Marcel Dekker Inc., New York
    • Rohlmann A., Graichen F., and Bergmann G. Loads on an internal spinal fixation device measured in vivo. In: Lewandrowski K.U., et al. (Ed). Advances in Spinal Fusion (2003), Marcel Dekker Inc., New York 699-710
    • (2003) Advances in Spinal Fusion , pp. 699-710
    • Rohlmann, A.1    Graichen, F.2    Bergmann, G.3
  • 13
    • 33847316886 scopus 로고    scopus 로고
    • An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column
    • Rohlmann A., Gabel U., Graichen F., Bender A., and Bergmann G. An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column. Med. Eng. Phys. 29 (2007) 580-585
    • (2007) Med. Eng. Phys. , vol.29 , pp. 580-585
    • Rohlmann, A.1    Gabel, U.2    Graichen, F.3    Bender, A.4    Bergmann, G.5
  • 14
    • 0002687308 scopus 로고
    • In vivo measurements of loads on an external fixation device for human lumbar spine fractures
    • Schläpfer F., Magerl F., Jacobs R., Perren S.M., and Weber B.G. In vivo measurements of loads on an external fixation device for human lumbar spine fractures. The Inst. Mech. Eng. C131/80 (1980) 59-64
    • (1980) The Inst. Mech. Eng. , Issue.C131-80 , pp. 59-64
    • Schläpfer, F.1    Magerl, F.2    Jacobs, R.3    Perren, S.M.4    Weber, B.G.5
  • 17
    • 0033560829 scopus 로고    scopus 로고
    • New in vivo measurements of pressures in the intervertebral disc in daily life
    • Wilke H.-J., Neef P., Caimi M., Hoogland T., and Claes L.E. New in vivo measurements of pressures in the intervertebral disc in daily life. Spine 24 (1999) 755-762
    • (1999) Spine , vol.24 , pp. 755-762
    • Wilke, H.-J.1    Neef, P.2    Caimi, M.3    Hoogland, T.4    Claes, L.E.5
  • 18
    • 0001290003 scopus 로고    scopus 로고
    • Intradiscal pressure together with anthropometric data - a data set for the validation of models
    • Wilke H.-J., Neef P., Hinz B., Seidel H., and Claes L. Intradiscal pressure together with anthropometric data - a data set for the validation of models. Clin. Biomech. 16 (2001) S111-S126
    • (2001) Clin. Biomech. , vol.16
    • Wilke, H.-J.1    Neef, P.2    Hinz, B.3    Seidel, H.4    Claes, L.5
  • 19
    • 38649128739 scopus 로고    scopus 로고
    • Wörsdörfer, O., 1981. Operative Stabilisierung der thorakolumbalen und lumbalen Wirbelsäule: Vergleichende biomechanische Untersuchungen zur Stabilität und Steifigkeit verschiedener dorsaler Fixationssysteme. Thesis, University of Ulm, Ulm, Germany.