메뉴 건너뛰기




Volumn 7, Issue 1, 2012, Pages

Accuracy and inter-observer variability of 3D versus 4D cone-beam CT based image-guidance in SBRT for lung tumors

Author keywords

Cone beam CT; Image guidance; Inter observer variability; Lung cancer; Respiration correlated imaging

Indexed keywords

ACCURACY; CANCER LOCALIZATION; CLINICAL ARTICLE; CONE BEAM COMPUTED TOMOGRAPHY; CONTROLLED STUDY; FOUR DIMENSIONAL COMPUTED TOMOGRAPHY; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; INTERMETHOD COMPARISON; LUNG CANCER; RETROSPECTIVE STUDY; REVIEW; STEREOTACTIC BODY RADIATION THERAPY; THREE DIMENSIONAL IMAGING;

EID: 84861935775     PISSN: None     EISSN: 1748717X     Source Type: Journal    
DOI: 10.1186/1748-717X-7-81     Document Type: Review
Times cited : (90)

References (23)
  • 1
    • 0037100122 scopus 로고    scopus 로고
    • Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy
    • 10.1016/S0360-3016(02)02803-1, 12095547
    • Seppenwoolde Y, Shirato H, Kitamura K, Shimizu S, van Herk M, Lebesque JV, Miyasaka K. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys 2002, 53(4):822-834. 10.1016/S0360-3016(02)02803-1, 12095547.
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , Issue.4 , pp. 822-834
    • Seppenwoolde, Y.1    Shirato, H.2    Kitamura, K.3    Shimizu, S.4    van Herk, M.5    Lebesque, J.V.6    Miyasaka, K.7
  • 2
    • 79957550479 scopus 로고    scopus 로고
    • Quality Assurance of 4D-CT Scan Techniques in Multicenter Phase III Trial of Surgery Versus Stereotactic Radiotherapy (Radiosurgery Or Surgery for operable Early stage (Stage 1A) non-small-cell Lung cancer [ROSEL] Study)
    • Hurkmans CW, van Lieshout M, Schuring D, van Heumen MJ, Cuijpers JP, Lagerwaard FJ, Widder J, van der Heide UA, Senan S. Quality Assurance of 4D-CT Scan Techniques in Multicenter Phase III Trial of Surgery Versus Stereotactic Radiotherapy (Radiosurgery Or Surgery for operable Early stage (Stage 1A) non-small-cell Lung cancer [ROSEL] Study). Int J Radiat Oncol Biol Phys 2010, 80(3):918-927.
    • (2010) Int J Radiat Oncol Biol Phys , vol.80 , Issue.3 , pp. 918-927
    • Hurkmans, C.W.1    van Lieshout, M.2    Schuring, D.3    van Heumen, M.J.4    Cuijpers, J.P.5    Lagerwaard, F.J.6    Widder, J.7    van der Heide, U.A.8    Senan, S.9
  • 3
    • 78650922691 scopus 로고    scopus 로고
    • Feasibility study for markerless tracking of lung tumors in stereotactic body radiotherapy
    • 10.1016/j.ijrobp.2009.11.028, 20452143
    • Richter A, Wilbert J, Baier K, Flentje M, Guckenberger M. Feasibility study for markerless tracking of lung tumors in stereotactic body radiotherapy. Int J Radiat Oncol Biol Phys 2010, 78(2):618-627. 10.1016/j.ijrobp.2009.11.028, 20452143.
    • (2010) Int J Radiat Oncol Biol Phys , vol.78 , Issue.2 , pp. 618-627
    • Richter, A.1    Wilbert, J.2    Baier, K.3    Flentje, M.4    Guckenberger, M.5
  • 4
    • 65749109343 scopus 로고    scopus 로고
    • Potential of image-guidance, gating and real-time tracking to improve accuracy in pulmonary stereotactic body radiotherapy
    • 10.1016/j.radonc.2008.08.010, 18835650
    • Guckenberger M, Krieger T, Richter A, Baier K, Wilbert J, Sweeney RA, Flentje M. Potential of image-guidance, gating and real-time tracking to improve accuracy in pulmonary stereotactic body radiotherapy. Radiother Oncol 2009, 91(3):288-295. 10.1016/j.radonc.2008.08.010, 18835650.
    • (2009) Radiother Oncol , vol.91 , Issue.3 , pp. 288-295
    • Guckenberger, M.1    Krieger, T.2    Richter, A.3    Baier, K.4    Wilbert, J.5    Sweeney, R.A.6    Flentje, M.7
  • 5
    • 84862662151 scopus 로고    scopus 로고
    • Respiration-correlated image guidance is the most important radiotherapy motion management strategy for most lung cancer patients
    • EPUB ahead of print
    • Korreman S, Persson G, Nygaard D, Brink C, Juhler-Nottrup T. Respiration-correlated image guidance is the most important radiotherapy motion management strategy for most lung cancer patients. Int J Radiat Oncol Biol Phys 2012, EPUB ahead of print.
    • (2012) Int J Radiat Oncol Biol Phys
    • Korreman, S.1    Persson, G.2    Nygaard, D.3    Brink, C.4    Juhler-Nottrup, T.5
  • 6
    • 17844379967 scopus 로고    scopus 로고
    • Respiratory correlated cone beam CT
    • 10.1118/1.1869074, 15895601
    • Sonke JJ, Zijp L, Remeijer P, van Herk M. Respiratory correlated cone beam CT. Med Phys 2005, 32(4):1176-1186. 10.1118/1.1869074, 15895601.
    • (2005) Med Phys , vol.32 , Issue.4 , pp. 1176-1186
    • Sonke, J.J.1    Zijp, L.2    Remeijer, P.3    van Herk, M.4
  • 7
    • 36148932560 scopus 로고    scopus 로고
    • On-line target position localization in the presence of respiration: a comparison of two methods
    • 10.1016/j.ijrobp.2007.08.023, 2170894, 18029112
    • Hugo GD, Liang J, Campbell J, Yan D. On-line target position localization in the presence of respiration: a comparison of two methods. Int J Radiat Oncol Biol Phys 2007, 69(5):1634-1641. 10.1016/j.ijrobp.2007.08.023, 2170894, 18029112.
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , Issue.5 , pp. 1634-1641
    • Hugo, G.D.1    Liang, J.2    Campbell, J.3    Yan, D.4
  • 8
    • 33748875872 scopus 로고    scopus 로고
    • Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors
    • 10.1080/02841860600904839, 16982556
    • Guckenberger M, Meyer J, Wilbert J, Baier K, Mueller G, Wulf J, Flentje M. Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors. Acta Oncol 2006, 45(7):897-906. 10.1080/02841860600904839, 16982556.
    • (2006) Acta Oncol , vol.45 , Issue.7 , pp. 897-906
    • Guckenberger, M.1    Meyer, J.2    Wilbert, J.3    Baier, K.4    Mueller, G.5    Wulf, J.6    Flentje, M.7
  • 9
    • 34247117297 scopus 로고    scopus 로고
    • Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position
    • 10.1016/j.ijrobp.2006.12.022, 17331671
    • Purdie TG, Bissonnette JP, Franks K, Bezjak A, Payne D, Sie F, Sharpe MB, Jaffray DA. Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position. Int J Radiat Oncol Biol Phys 2007, 68(1):243-252. 10.1016/j.ijrobp.2006.12.022, 17331671.
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , Issue.1 , pp. 243-252
    • Purdie, T.G.1    Bissonnette, J.P.2    Franks, K.3    Bezjak, A.4    Payne, D.5    Sie, F.6    Sharpe, M.B.7    Jaffray, D.A.8
  • 10
    • 51049114274 scopus 로고    scopus 로고
    • On-line image guidance for frameless stereotactic radiotherapy of lung malignancies by cone beam CT: comparison between target localization and alignment on bony anatomy
    • 10.1080/02841860802251534, 18654905
    • Masi L, Casamassima F, Menichelli C, Pasciuti K, Doro R, Polli C, D'Imporzano E, Bonucci I. On-line image guidance for frameless stereotactic radiotherapy of lung malignancies by cone beam CT: comparison between target localization and alignment on bony anatomy. Acta Oncol 2008, 47(7):1422-1431. 10.1080/02841860802251534, 18654905.
    • (2008) Acta Oncol , vol.47 , Issue.7 , pp. 1422-1431
    • Masi, L.1    Casamassima, F.2    Menichelli, C.3    Pasciuti, K.4    Doro, R.5    Polli, C.6    D'Imporzano, E.7    Bonucci, I.8
  • 11
    • 36148946374 scopus 로고    scopus 로고
    • Cone-beam CT localization of internal target volumes for stereotactic body radiotherapy of lung lesions
    • 10.1016/j.ijrobp.2007.08.030, 18035215
    • Wang Z, Wu QJ, Marks LB, Larrier N, Yin FF. Cone-beam CT localization of internal target volumes for stereotactic body radiotherapy of lung lesions. Int J Radiat Oncol Biol Phys 2007, 69(5):1618-1624. 10.1016/j.ijrobp.2007.08.030, 18035215.
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , Issue.5 , pp. 1618-1624
    • Wang, Z.1    Wu, Q.J.2    Marks, L.B.3    Larrier, N.4    Yin, F.F.5
  • 12
    • 70349554149 scopus 로고    scopus 로고
    • Quantifying interfraction and intrafraction tumor motion in lung stereotactic body radiotherapy using respiration-correlated cone beam computed tomography
    • 10.1016/j.ijrobp.2008.11.066, 19395200
    • Bissonnette JP, Franks KN, Purdie TG, Moseley DJ, Sonke JJ, Jaffray DA, Dawson LA, Bezjak A. Quantifying interfraction and intrafraction tumor motion in lung stereotactic body radiotherapy using respiration-correlated cone beam computed tomography. Int J Radiat Oncol Biol Phys 2009, 75(3):688-695. 10.1016/j.ijrobp.2008.11.066, 19395200.
    • (2009) Int J Radiat Oncol Biol Phys , vol.75 , Issue.3 , pp. 688-695
    • Bissonnette, J.P.1    Franks, K.N.2    Purdie, T.G.3    Moseley, D.J.4    Sonke, J.J.5    Jaffray, D.A.6    Dawson, L.A.7    Bezjak, A.8
  • 13
    • 67349247094 scopus 로고    scopus 로고
    • Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance
    • 10.1016/j.ijrobp.2008.08.004, 19046825
    • Sonke JJ, Rossi M, Wolthaus J, van Herk M, Damen E, Belderbos J. Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance. Int J Radiat Oncol Biol Phys 2009, 74(2):567-574. 10.1016/j.ijrobp.2008.08.004, 19046825.
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , Issue.2 , pp. 567-574
    • Sonke, J.J.1    Rossi, M.2    Wolthaus, J.3    van Herk, M.4    Damen, E.5    Belderbos, J.6
  • 14
    • 39749185557 scopus 로고    scopus 로고
    • Image-Guided Radiotherapy via Daily Online Cone-Beam CT Substantially Reduces Margin Requirements for Stereotactic Lung Radiotherapy
    • 10.1016/j.ijrobp.2007.07.2352, 18029110
    • Grills IS, Hugo G, Kestin LL, Galerani AP, Chao KK, Wloch J, Yan D. Image-Guided Radiotherapy via Daily Online Cone-Beam CT Substantially Reduces Margin Requirements for Stereotactic Lung Radiotherapy. Int J Radiat Oncol Biol Phys 2008, 70(4):1045-1056. 10.1016/j.ijrobp.2007.07.2352, 18029110.
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , Issue.4 , pp. 1045-1056
    • Grills, I.S.1    Hugo, G.2    Kestin, L.L.3    Galerani, A.P.4    Chao, K.K.5    Wloch, J.6    Yan, D.7
  • 15
    • 77956574316 scopus 로고    scopus 로고
    • Inter- and intrafractional localisation errors in cone-beam CT guided stereotactic radiation therapy of tumours in the liver and lung
    • 10.3109/0284186X.2010.498435, 20590367
    • Worm ES, Hansen AT, Petersen JB, Muren LP, Praestegaard LH, Hoyer M. Inter- and intrafractional localisation errors in cone-beam CT guided stereotactic radiation therapy of tumours in the liver and lung. Acta Oncol 2010, 49(7):1177-1183. 10.3109/0284186X.2010.498435, 20590367.
    • (2010) Acta Oncol , vol.49 , Issue.7 , pp. 1177-1183
    • Worm, E.S.1    Hansen, A.T.2    Petersen, J.B.3    Muren, L.P.4    Praestegaard, L.H.5    Hoyer, M.6
  • 16
    • 34047145827 scopus 로고    scopus 로고
    • Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors
    • 10.1016/j.radonc.2007.01.012, 17306394
    • Guckenberger M, Meyer J, Wilbert J, Richter A, Baier K, Mueller G, Flentje M. Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors. Radiother Oncol 2007, 83(1):57-64. 10.1016/j.radonc.2007.01.012, 17306394.
    • (2007) Radiother Oncol , vol.83 , Issue.1 , pp. 57-64
    • Guckenberger, M.1    Meyer, J.2    Wilbert, J.3    Richter, A.4    Baier, K.5    Mueller, G.6    Flentje, M.7
  • 17
    • 73649140602 scopus 로고    scopus 로고
    • American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) practice guideline for the performance of stereotactic body radiation therapy
    • 10.1016/j.ijrobp.2009.09.042, 20117285
    • Potters L, Kavanagh B, Galvin JM, Hevezi JM, Janjan NA, Larson DA, Mehta MP, Ryu S, Steinberg M, Timmerman R, et al. American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) practice guideline for the performance of stereotactic body radiation therapy. Int J Radiat Oncol Biol Phys 2010, 76(2):326-332. 10.1016/j.ijrobp.2009.09.042, 20117285.
    • (2010) Int J Radiat Oncol Biol Phys , vol.76 , Issue.2 , pp. 326-332
    • Potters, L.1    Kavanagh, B.2    Galvin, J.M.3    Hevezi, J.M.4    Janjan, N.A.5    Larson, D.A.6    Mehta, M.P.7    Ryu, S.8    Steinberg, M.9    Timmerman, R.10
  • 19
    • 41749104005 scopus 로고    scopus 로고
    • Image-guided radiotherapy for liver cancer using respiratory-correlated computed tomography and cone-beam computed tomography
    • 10.1016/j.ijrobp.2008.01.005, 18406894
    • Guckenberger M, Sweeney RA, Wilbert J, Krieger T, Richter A, Baier K, Mueller G, Sauer O, Flentje M. Image-guided radiotherapy for liver cancer using respiratory-correlated computed tomography and cone-beam computed tomography. Int J Radiat Oncol Biol Phys 2008, 71(1):297-304. 10.1016/j.ijrobp.2008.01.005, 18406894.
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , Issue.1 , pp. 297-304
    • Guckenberger, M.1    Sweeney, R.A.2    Wilbert, J.3    Krieger, T.4    Richter, A.5    Baier, K.6    Mueller, G.7    Sauer, O.8    Flentje, M.9
  • 20
    • 33644550948 scopus 로고    scopus 로고
    • Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy
    • 10.1016/j.ijrobp.2005.11.016, 16504762
    • Shirato H, Suzuki K, Sharp GC, Fujita K, Onimaru R, Fujino M, Kato N, Osaka Y, Kinoshita R, Taguchi H, et al. Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy. Int J Radiat Oncol Biol Phys 2006, 64(4):1229-1236. 10.1016/j.ijrobp.2005.11.016, 16504762.
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , Issue.4 , pp. 1229-1236
    • Shirato, H.1    Suzuki, K.2    Sharp, G.C.3    Fujita, K.4    Onimaru, R.5    Fujino, M.6    Kato, N.7    Osaka, Y.8    Kinoshita, R.9    Taguchi, H.10
  • 21
    • 77249134524 scopus 로고    scopus 로고
    • The European Society of Therapeutic Radiology and Oncology-European Institute of Radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide
    • 10.1016/j.radonc.2010.01.004, 20153908
    • Korreman S, Rasch C, McNair H, Verellen D, Oelfke U, Maingon P, Mijnheer B, Khoo V. The European Society of Therapeutic Radiology and Oncology-European Institute of Radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide. Radiother Oncol 2010, 94(2):129-144. 10.1016/j.radonc.2010.01.004, 20153908.
    • (2010) Radiother Oncol , vol.94 , Issue.2 , pp. 129-144
    • Korreman, S.1    Rasch, C.2    McNair, H.3    Verellen, D.4    Oelfke, U.5    Maingon, P.6    Mijnheer, B.7    Khoo, V.8
  • 22
    • 73649088616 scopus 로고    scopus 로고
    • American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) practice guidelines for image-guided radiation therapy (IGRT)
    • 10.1016/j.ijrobp.2009.09.041, 20117284
    • Potters L, Gaspar LE, Kavanagh B, Galvin JM, Hartford AC, Hevezi JM, Kupelian PA, Mohiden N, Samuels MA, Timmerman R, et al. American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) practice guidelines for image-guided radiation therapy (IGRT). Int J Radiat Oncol Biol Phys 2010, 76(2):319-325. 10.1016/j.ijrobp.2009.09.041, 20117284.
    • (2010) Int J Radiat Oncol Biol Phys , vol.76 , Issue.2 , pp. 319-325
    • Potters, L.1    Gaspar, L.E.2    Kavanagh, B.3    Galvin, J.M.4    Hartford, A.C.5    Hevezi, J.M.6    Kupelian, P.A.7    Mohiden, N.8    Samuels, M.A.9    Timmerman, R.10
  • 23
    • 78549281030 scopus 로고    scopus 로고
    • Dosimetric impact of online correction via cone-beam CT-based image guidance for stereotactic lung radiotherapy
    • 10.1016/j.ijrobp.2010.02.012, 20646857
    • Galerani AP, Grills I, Hugo G, Kestin L, Mohammed N, Chao KK, Suen A, Martinez A, Yan D. Dosimetric impact of online correction via cone-beam CT-based image guidance for stereotactic lung radiotherapy. Int J Radiat Oncol Biol Phys 2010, 78(5):1571-1578. 10.1016/j.ijrobp.2010.02.012, 20646857.
    • (2010) Int J Radiat Oncol Biol Phys , vol.78 , Issue.5 , pp. 1571-1578
    • Galerani, A.P.1    Grills, I.2    Hugo, G.3    Kestin, L.4    Mohammed, N.5    Chao, K.K.6    Suen, A.7    Martinez, A.8    Yan, D.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.