메뉴 건너뛰기




Volumn 17, Issue 3, 2012, Pages 168-173

Aneurysm sac shrinkage after endovascular treatment of the aorta: Beyond sac pressure and endoleaks

Author keywords

abdominal aortic aneurysm; biomechanics; endoleak; endotension; endovascular aneurysm repair; sac shrinkage

Indexed keywords

FLUORODEOXYGLUCOSE F 18; GELATINASE B; STROMELYSIN;

EID: 84861825819     PISSN: 1358863X     EISSN: 14770377     Source Type: Journal    
DOI: 10.1177/1358863X11431293     Document Type: Review
Times cited : (24)

References (43)
  • 1
    • 19044393090 scopus 로고    scopus 로고
    • Ad Hoc Committee for Standardized Reporting Practices in Vascular Surgery of the Society for Vascular Surgery/American Association for Vascular Surgery. Reporting standards for endovascular aortic aneurysm repair
    • Chaikof EL, Blankensteijn JD, Harris PL, et al. Ad Hoc Committee for Standardized Reporting Practices in Vascular Surgery of The Society for Vascular Surgery/American Association for Vascular Surgery. Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg. 2002 ; 35: 1048-1060
    • (2002) J Vasc Surg , vol.35 , pp. 1048-1060
    • Chaikof, E.L.1    Blankensteijn, J.D.2    Harris, P.L.3
  • 2
    • 69849110798 scopus 로고    scopus 로고
    • Type II endoleaks: When is intervention indicated and what is the index of suspicion for types i or III?
    • Lawrence-Brown MM, Sun Z, Semmens JB, Liffman K, Sutalo ID, Hartley DB. Type II endoleaks: when is intervention indicated and what is the index of suspicion for types I or III?. J Endovasc Ther. 2009 ; 16: I106-118
    • (2009) J Endovasc Ther , vol.16 , pp. 106-118
    • Lawrence-Brown, M.M.1    Sun, Z.2    Semmens, J.B.3    Liffman, K.4    Sutalo, I.D.5    Hartley, D.B.6
  • 3
    • 58249091918 scopus 로고    scopus 로고
    • Endotension following endovascular aneurysm repair
    • Toya N, Fujita T, Kanaoka Y, Ohki T. Endotension following endovascular aneurysm repair. Vasc Med. 2008 ; 13: 305-311
    • (2008) Vasc Med , vol.13 , pp. 305-311
    • Toya, N.1    Fujita, T.2    Kanaoka, Y.3    Ohki, T.4
  • 4
    • 79551698793 scopus 로고    scopus 로고
    • Part Two: Against the motion. measuring intra-sac pressure measurements is of no benefit to the patient
    • De Rango P, Verzini F, Cao P. Part Two: against the motion. measuring intra-sac pressure measurements is of no benefit to the patient. Eur J Vasc Endovasc Surg. 2011 ; 4: 145-148
    • (2011) Eur J Vasc Endovasc Surg , vol.4 , pp. 145-148
    • De Rango, P.1    Verzini, F.2    Cao, P.3
  • 5
    • 79551707881 scopus 로고    scopus 로고
    • Part one: For the motion. Serial sac pressure measurements can determine which type II endoleaks can be treated
    • Milner R. Part one: for the motion. Serial sac pressure measurements can determine which type II endoleaks can be treated. Eur J Vasc Endovasc Surg. 2011 ; 4: 143-145
    • (2011) Eur J Vasc Endovasc Surg , vol.4 , pp. 143-145
    • Milner, R.1
  • 6
    • 49449108619 scopus 로고    scopus 로고
    • A review of the in vivo and in vitro biomechanical behavior and performance of postoperative abdominal aortic aneurysms and implanted stent-grafts
    • Corbett TJ, Callanan A, Morris LG, et al. A review of the in vivo and in vitro biomechanical behavior and performance of postoperative abdominal aortic aneurysms and implanted stent-grafts. J Endovasc Ther. 2008 ; 15: 468-484
    • (2008) J Endovasc Ther , vol.15 , pp. 468-484
    • Corbett, T.J.1    Callanan, A.2    Morris, L.G.3
  • 7
    • 79959532653 scopus 로고    scopus 로고
    • Predictors of abdominal aortic aneurysm sac enlargement after endovascular repair
    • Schanzer A, Greenberg RK, Hevelone N, et al. Predictors of abdominal aortic aneurysm sac enlargement after endovascular repair. Circulation. 2011 ; 123: 2848-2855
    • (2011) Circulation , vol.123 , pp. 2848-2855
    • Schanzer, A.1    Greenberg, R.K.2    Hevelone, N.3
  • 8
    • 4444236192 scopus 로고    scopus 로고
    • Intrasac pressure waveforms after endovascular aneurysm repair (EVAR) are a reliable marker of type I endoleaks, but not type II or combined types: An experimental study
    • DOI 10.1016/j.ejvs.2004.07.006, PII S1078588404003223
    • Chaudhuri A, Ansdell LE, Grass AJ, Adiseshiah M. Intrasac pressure waveforms after endovascular aneurysm repair (EVAR) are a reliable marker of type I endoleaks, but not type II or combined types: an experimental study. Eur J Vasc Endovasc Surg. 2004 ; 28: 373-378 (Pubitemid 39207086)
    • (2004) European Journal of Vascular and Endovascular Surgery , vol.28 , Issue.4 , pp. 373-378
    • Chaudhuri, A.1    Ansdell, L.E.2    Grass, A.J.3    Adiseshiah, M.4
  • 11
    • 79952111355 scopus 로고    scopus 로고
    • Duplex ultrasound factors predicting persistent type II endoleak and increasing AAA sac diameter after EVAR
    • Beeman BR, Murtha K, Doerr K, McAfee-Bennett S, Dougherty MJ, Calligaro KD. Duplex ultrasound factors predicting persistent type II endoleak and increasing AAA sac diameter after EVAR. J Vasc Surg. 2010 ; 52: 1147-1152
    • (2010) J Vasc Surg , vol.52 , pp. 1147-1152
    • Beeman, B.R.1    Murtha, K.2    Doerr, K.3    McAfee-Bennett, S.4    Dougherty, M.J.5    Calligaro, K.D.6
  • 12
    • 77950063631 scopus 로고    scopus 로고
    • Duplex ultrasound and contrast-enhanced ultrasound versus computed tomography for the detection of endoleak after EVAR: Systematic review and bivariate meta-analysis
    • Mirza TA, Karthikesalingam A, Jackson D, et al. Duplex ultrasound and contrast-enhanced ultrasound versus computed tomography for the detection of endoleak after EVAR: systematic review and bivariate meta-analysis. Eur J Vasc Endovasc Surg. 2010 ; 39: 418-428
    • (2010) Eur J Vasc Endovasc Surg , vol.39 , pp. 418-428
    • Mirza, T.A.1    Karthikesalingam, A.2    Jackson, D.3
  • 13
    • 13244258389 scopus 로고    scopus 로고
    • Type II lumbar endoleaks: Hemodynamic differentiation by contrast-enhanced ultrasound scanning and influence on aneurysm enlargement after endovascular aneurysm repair
    • DOI 10.1016/j.jvs.2004.10.037, PII S0741521404013692
    • Bargellini I, Napoli V, Petruzzi P, et al. Type II lumbar endoleaks: hemodynamic differentiation by contrast-enhanced ultrasound scanning and influence on aneurysm enlargement after endovascular aneurysm repair. J Vasc Surg. 2005 ; 41: 10-18 (Pubitemid 40193333)
    • (2005) Journal of Vascular Surgery , vol.41 , Issue.1 , pp. 10-18
    • Bargellini, I.1    Napoli, V.2    Petruzzi, P.3    Cioni, R.4    Vignali, C.5    Sardella, S.G.6    Ferrari, M.7    Bartolozzi, C.8
  • 14
    • 33645749756 scopus 로고    scopus 로고
    • Factors predictive of early or late aneurysm sac size change following endovascular repair
    • Fairman RM, Nolte L, Snyder SA, Chuter TA, Greenberg RK. Factors predictive of early or late aneurysm sac size change following endovascular repair. J Vasc Surg. 2006 ; 43: 649-656
    • (2006) J Vasc Surg , vol.43 , pp. 649-656
    • Fairman, R.M.1    Nolte, L.2    Snyder, S.A.3    Chuter, T.A.4    Greenberg, R.K.5
  • 18
    • 3242716166 scopus 로고    scopus 로고
    • Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: Differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks
    • DOI 10.1016/j.jvs.2004.02.041, PII S0741521404003040
    • Dias NV, Ivancev K, Malina M, Resch T, Lindblad B, Sonesson B. Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks. J Vasc Surg. 2004 ; 39: 1229-1235 (Pubitemid 38952589)
    • (2004) Journal of Vascular Surgery , vol.39 , Issue.6 , pp. 1229-1235
    • Dias, N.V.1    Ivancev, K.2    Malina, M.3    Resch, T.4    Lindblad, B.5    Sonesson, B.6
  • 19
    • 79951733874 scopus 로고    scopus 로고
    • Intrasac pressure changes and vascular remodeling after endovascular repair of abdominal aortic aneurysms: Review and biomechanical model simulation
    • Kwon ST, Rectenwald JE, Baek S. Intrasac pressure changes and vascular remodeling after endovascular repair of abdominal aortic aneurysms: review and biomechanical model simulation. J Biomech Eng. 2011 ; 133: 011011
    • (2011) J Biomech Eng , vol.133 , pp. 011011
    • Kwon, S.T.1    Rectenwald, J.E.2    Baek, S.3
  • 20
    • 74049095217 scopus 로고    scopus 로고
    • Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft
    • Molony DS, Callanan A, Kavanagh EG, Walsh MT, McGloughlin TM. Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft. Biomed Eng Online. 2009 ; 8: 24
    • (2009) Biomed Eng Online , vol.8 , pp. 24
    • Molony, D.S.1    Callanan, A.2    Kavanagh, E.G.3    Walsh, M.T.4    McGloughlin, T.M.5
  • 22
    • 0345599885 scopus 로고    scopus 로고
    • Influence of intraluminal thrombus on structural and cellular composition of abdominal aortic aneurysm wall
    • DOI 10.1016/S0741-5214(03)00791-2
    • Kazi M, Thyberg J, Religa P, et al. Influence of intraluminal thrombus on structural and cellular composition of abdominal aortic aneurysm wall. J Vasc Surg. 2003 ; 38: 1283-1292 (Pubitemid 37517657)
    • (2003) Journal of Vascular Surgery , vol.38 , Issue.6 , pp. 1283-1292
    • Kazi, M.1    Thyberg, J.2    Religa, P.3    Roy, J.4    Eriksson, P.5    Hedin, U.6    Swedenborg, J.7
  • 24
    • 56849132156 scopus 로고    scopus 로고
    • Elastin degradation within the abdominal aortic aneurysm wall-relationship between intramural pH and adjacent thrombus formation
    • Wiernicki I, Cnotliwy M, Baranowska-Bosiacka I, et al. Elastin degradation within the abdominal aortic aneurysm wall-relationship between intramural pH and adjacent thrombus formation. Eur J Clin Invest. 2008 ; 38: 883-887
    • (2008) Eur J Clin Invest , vol.38 , pp. 883-887
    • Wiernicki, I.1    Cnotliwy, M.2    Baranowska-Bosiacka, I.3
  • 29
    • 58149177344 scopus 로고    scopus 로고
    • Compliance of abdominal aortic aneurysms before and after stenting with tissue Doppler imaging: Evolution during follow-up and correlation with aneurysm diameter
    • Long A, Rouet L, Vitry F, Albertini JN, Marcus C, Clement C. Compliance of abdominal aortic aneurysms before and after stenting with tissue Doppler imaging: evolution during follow-up and correlation with aneurysm diameter. Ann Vasc Surg. 2009 ; 23: 49-59
    • (2009) Ann Vasc Surg , vol.23 , pp. 49-59
    • Long, A.1    Rouet, L.2    Vitry, F.3    Albertini, J.N.4    Marcus, C.5    Clement, C.6
  • 30
    • 68549097927 scopus 로고    scopus 로고
    • In-vivo imaging of changes in abdominal aortic aneurysm thrombus volume during the cardiac cycle
    • Truijers M, Fillinger MF, Renema KW, et al. In-vivo imaging of changes in abdominal aortic aneurysm thrombus volume during the cardiac cycle. J Endovasc Ther. 2009 ; 16: 314-319
    • (2009) J Endovasc Ther , vol.16 , pp. 314-319
    • Truijers, M.1    Fillinger, M.F.2    Renema, K.W.3
  • 31
    • 72549118167 scopus 로고    scopus 로고
    • The mechanical role of thrombus on the growth rate of an abdominal aortic aneurysm
    • Speelman L, Schurink GW, Bosboom EM, et al. The mechanical role of thrombus on the growth rate of an abdominal aortic aneurysm. J Vasc Surg. 2010 ; 51: 19-26
    • (2010) J Vasc Surg , vol.51 , pp. 19-26
    • Speelman, L.1    Schurink, G.W.2    Bosboom, E.M.3
  • 35
    • 49449096807 scopus 로고    scopus 로고
    • Reduced strain in abdominal aortic aneurysms after endovascular repair
    • Brekken R, Dahl T, Hernes TA, Myhre HO. Reduced strain in abdominal aortic aneurysms after endovascular repair. J Endovasc Ther. 2008 ; 15: 453-461
    • (2008) J Endovasc Ther , vol.15 , pp. 453-461
    • Brekken, R.1    Dahl, T.2    Hernes, T.A.3    Myhre, H.O.4
  • 36
    • 70350170546 scopus 로고    scopus 로고
    • Potential value of aneurysm sac volume measurements in addition to diameter measurements after endovascular aneurysm repair
    • Van Keulen JW, van Prehn J, Prokop M, Moll FL, van Herwaarden JA. Potential value of aneurysm sac volume measurements in addition to diameter measurements after endovascular aneurysm repair. J Endovasc Ther. 2009 ; 16: 506-513
    • (2009) J Endovasc Ther , vol.16 , pp. 506-513
    • Van Keulen, J.W.1    Van Prehn, J.2    Prokop, M.3    Moll, F.L.4    Van Herwaarden, J.A.5
  • 37
    • 58149265250 scopus 로고    scopus 로고
    • Circulating markers of abdominal aortic aneurysm presence and progression
    • Golledge J, Tsao PS, Dalman RL, Norman PE. Circulating markers of abdominal aortic aneurysm presence and progression. Circulation. 2008 ; 118: 2382-2392
    • (2008) Circulation , vol.118 , pp. 2382-2392
    • Golledge, J.1    Tsao, P.S.2    Dalman, R.L.3    Norman, P.E.4
  • 38
    • 0035908984 scopus 로고    scopus 로고
    • Plasma levels of metalloproteinases-3 and -9 as markers of successful abdominal aortic aneurysm exclusion after endovascular graft treatment
    • Sangiorgi G, D'Averio R, Mauriello A, et al. Plasma levels of metalloproteinases-3 and -9 as markers of successful abdominal aortic aneurysm exclusion after endovascular graft treatment. Circulation. 2001 ; 104: I288-295
    • (2001) Circulation , vol.104 , pp. 288-295
    • Sangiorgi, G.1    D'Averio, R.2    Mauriello, A.3
  • 39
    • 0036580865 scopus 로고    scopus 로고
    • Response of plasma matrix metalloproteinase-9 to conventional abdominal aortic aneurysm repair or endovascular exclusion: Implications for endoleak
    • DOI 10.1067/mva.2002.123676
    • Lorelli DR, Jean-Claude JM, Fox CJ, et al. Response of plasma matrix metalloproteinase-9 to conventional abdominal aortic aneurysm repair or endovascular exclusion: implications for endoleak. J Vasc Surg. 2002 ; 35: 916-922 (Pubitemid 44718559)
    • (2002) Journal of Vascular Surgery , vol.35 , Issue.5 , pp. 916-922
    • Lorelli, D.R.1    Jean-Claude, J.M.2    Fox, C.J.3    Clyne, J.4    Cambria, R.A.5    Seabrook, G.R.6    Towne, J.B.7
  • 40
    • 34548857619 scopus 로고    scopus 로고
    • Response of plasma matrix metalloproteinases and tissue inhibitor of metalloproteinases to stent-graft surgery for descending thoracic aortic aneurysms
    • DOI 10.1016/j.jtcvs.2007.05.044, PII S0022522307009944
    • Monaco M, Stassano P, Di Tommaso L, Iannelli G. Response of plasma matrix metalloproteinases and tissue inhibitor of metalloproteinases to stent-graft surgery for descending thoracic aortic aneurysms. J Thorac Cardiovasc Surg. 2007 ; 134: 925-931 (Pubitemid 47449699)
    • (2007) Journal of Thoracic and Cardiovascular Surgery , vol.134 , Issue.4 , pp. 925-931
    • Monaco, M.1    Stassano, P.2    Di Tommaso, L.3    Iannelli, G.4
  • 41
    • 78650510607 scopus 로고    scopus 로고
    • A randomized placebo controlled trial of the effect of preoperative statin use on matrix metalloproteinases and tissue inhibitors of matrix metalloproteinases in areas of low and peak wall stress in patients undergoing elective open repair of abdominal aortic aneurysm
    • Rahman MN, Khan JA, Mazari FA, Mockford K, McCollum PT, Chetter IC. A randomized placebo controlled trial of the effect of preoperative statin use on matrix metalloproteinases and tissue inhibitors of matrix metalloproteinases in areas of low and peak wall stress in patients undergoing elective open repair of abdominal aortic aneurysm. Ann Vasc Surg. 2011 ; 25: 32-38
    • (2011) Ann Vasc Surg , vol.25 , pp. 32-38
    • Rahman, M.N.1    Khan, J.A.2    Mazari, F.A.3    Mockford, K.4    McCollum, P.T.5    Chetter, I.C.6
  • 42
    • 77649270390 scopus 로고    scopus 로고
    • High levels of 18F-FDG uptake in aortic aneurysm wall are associated with high wall stress
    • Xu XY, Borghi A, Nchimi A, et al. High levels of 18F-FDG uptake in aortic aneurysm wall are associated with high wall stress. Eur J Vasc Endovasc Surg. 2010 ; 39: 295-301
    • (2010) Eur J Vasc Endovasc Surg , vol.39 , pp. 295-301
    • Xu, X.Y.1    Borghi, A.2    Nchimi, A.3
  • 43
    • 78249271393 scopus 로고    scopus 로고
    • Increased fluorodeoxyglucose uptake following endovascular abdominal aortic aneurysm repair: A predictor of endoleak?
    • Paraskevas KI, Tzovaras AA, Stathopoulos V, Gentimi F, Mikhailidis DP. Increased fluorodeoxyglucose uptake following endovascular abdominal aortic aneurysm repair: a predictor of endoleak?. Open Cardiovasc Med J. 2010 ; 4: 117-119
    • (2010) Open Cardiovasc Med J , vol.4 , pp. 117-119
    • Paraskevas, K.I.1    Tzovaras, A.A.2    Stathopoulos, V.3    Gentimi, F.4    Mikhailidis, D.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.