메뉴 건너뛰기




Volumn 52, Issue 5, 2010, Pages 1147-1152

Duplex ultrasound factors predicting persistent type II endoleak and increasing AAA sac diameter after EVAR

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ANEURYSM RUPTURE; ARTERY DIAMETER; ARTICLE; B SCAN; BLOOD FLOW VELOCITY; CLINICAL ARTICLE; DOPPLER ECHOGRAPHY; ECHOGRAPHY; ENDOLEAK; ENDOVASCULAR ANEURYSM REPAIR; FOLLOW UP; HUMAN; IMAGE ANALYSIS; PREDICTIVE VALUE; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SURGICAL PATIENT; BLOOD VESSEL PROSTHESIS; BLOOD VESSEL TRANSPLANTATION; COLOR ULTRASOUND FLOWMETRY; ENDOVASCULAR SURGERY; HEMODYNAMICS; INSTRUMENTATION; PATHOPHYSIOLOGY; PROSTHESIS; PROSTHESIS FAILURE; REGISTER; REOPERATION; RISK ASSESSMENT; RISK FACTOR; TIME; TREATMENT OUTCOME; UNITED STATES;

EID: 79952111355     PISSN: 07415214     EISSN: 10976809     Source Type: Journal    
DOI: 10.1016/j.jvs.2010.06.099     Document Type: Article
Times cited : (34)

References (21)
  • 1
    • 0026321992 scopus 로고
    • Transfemoral intraluminal graft implantation for abdominal aortic aneurysms
    • Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991;5: 491-9.
    • (1991) Ann Vasc Surg , vol.5 , pp. 491-499
    • Parodi, J.C.1    Palmaz, J.C.2    Barone, H.D.3
  • 2
    • 4544312566 scopus 로고    scopus 로고
    • What is the significance of endoleaks and endotension?
    • Heikkinen MA, Arko FR, Zarins CK. What is the significance of endoleaks and endotension? Surg Clin N Am 2004;84:1337-52.
    • (2004) Surg Clin N Am , vol.84 , pp. 1337-1352
    • Heikkinen, M.A.1    Arko, F.R.2    Zarins, C.K.3
  • 3
    • 34250803155 scopus 로고    scopus 로고
    • Persistent type 2 endoleak after endovascular repair of abdominal aoric aneurysm is associated with adverse late outcomes
    • Jones JE, Atkins MD, Brewster DC, Chung TK, Kwolek CJ, LaMuraglia GM, et al. Persistent type 2 endoleak after endovascular repair of abdominal aoric aneurysm is associated with adverse late outcomes. J Vasc Surg 2007;46:1-8.
    • (2007) J Vasc Surg , vol.46 , pp. 1-8
    • Jones, J.E.1    Atkins, M.D.2    Brewster, D.C.3    Chung, T.K.4    Kwolek, C.J.5    Lamuraglia, G.M.6
  • 4
    • 0036358205 scopus 로고    scopus 로고
    • Treatment of type 2 endoleaks after endovas-cular repair of abdominal aortic aneurysms: Comparison of transarterial and translumbar techniques
    • Baum RA, Carpenter JP, Golden MA, Velazquez OC, Clark TWI, Stavropoulous W, et al. Treatment of type 2 endoleaks after endovas-cular repair of abdominal aortic aneurysms: comparison of transarterial and translumbar techniques. J Vasc Surg 2002;35:23-9.
    • (2002) J Vasc Surg , vol.35 , pp. 23-29
    • Baum, R.A.1    Carpenter, J.P.2    Golden, M.A.3    Velazquez, O.C.4    Clark, T.W.I.5    Stavropoulous, W.6
  • 5
    • 0034235048 scopus 로고    scopus 로고
    • En-doleak as a predictor of outcomes after endovascular aneurysm repair: AneuRx multicenter clinical trial
    • Zarins CK, White RA, Hodgson KJ, Schwarten D, Fogarty TJ. En-doleak as a predictor of outcomes after endovascular aneurysm repair: AneuRx multicenter clinical trial. J Vasc Surg 2000;32:90-107.
    • (2000) J Vasc Surg , vol.32 , pp. 90-107
    • Zarins, C.K.1    White, R.A.2    Hodgson, K.J.3    Schwarten, D.4    Fogarty, T.J.5
  • 6
    • 0036595201 scopus 로고    scopus 로고
    • Clinical failures of endovascular abdominal aortic aneurysm repair: Incidence, causes, and management
    • Dattilo JB, Brewster DC, Fan CM, Geller SC, Cambria RP, LaMuraglia GM, et al. Clinical failures of endovascular abdominal aortic aneurysm repair: incidence, causes, and management. J Vasc Surg 2002;35:1137-44.
    • (2002) J Vasc Surg , vol.35 , pp. 1137-1144
    • Dattilo, J.B.1    Brewster, D.C.2    Fan, C.M.3    Geller, S.C.4    Cambria, R.P.5    Lamuraglia, G.M.6
  • 8
    • 0038071755 scopus 로고    scopus 로고
    • Management of endoleak after endovascular aneurysm repair: Cuffs, coils, and conversion
    • Faries PL, Cadot H, Agarwal G, Kent CK, Hollier LH, Marin ML. Management of endoleak after endovascular aneurysm repair: cuffs, coils, and conversion. J Vasc Surg 2003;37:1155-61.
    • (2003) J Vasc Surg , vol.37 , pp. 1155-1161
    • Faries, P.L.1    Cadot, H.2    Agarwal, G.3    Kent, C.K.4    Hollier, L.H.5    Marin, M.L.6
  • 9
    • 0031896189 scopus 로고    scopus 로고
    • Clinical consequences of periprosthetic leak after endovascular repair of abdominal aortic aneurysm
    • Matsumura JS, Moore WS. Clinical consequences of periprosthetic leak after endovascular repair of abdominal aortic aneurysm. J Vasc Surg 1998;27:606-13.
    • (1998) J Vasc Surg , vol.27 , pp. 606-613
    • Matsumura, J.S.1    Moore, W.S.2
  • 10
    • 0037268753 scopus 로고    scopus 로고
    • Controversies in the management of type ii "branch" endoleaks following endovascular abdominal aortic aneurysm repair
    • Maldonado T, Gagne P. Controversies in the Management of type II "branch" endoleaks following endovascular abdominal aortic aneurysm repair. Vasc Endovascular Surg 2003;37:1-12.
    • (2003) Vasc Endovascular Surg , vol.37 , pp. 1-12
    • Maldonado, T.1    Gagne, P.2
  • 13
    • 0346356516 scopus 로고    scopus 로고
    • Doppler waveform assessment of endoleak following endovas-cular repair of abdominal aortic aneursym: Predictors of endoleak thrombosis
    • Carter KA, Nelms CR, Bloch PHS, Gregory RT, Parent NE, DeMasi RJ, et al. Doppler waveform assessment of endoleak following endovas-cular repair of abdominal aortic aneursym: predictors of endoleak thrombosis. J Vasc Technology 2000;24:119-22.
    • (2000) J Vasc Technology , vol.24 , pp. 119-122
    • Carter, K.A.1    Nelms, C.R.2    Bloch, P.H.S.3    Gregory, R.T.4    Parent, N.E.5    Demasi, R.J.6
  • 14
    • 19044370276 scopus 로고    scopus 로고
    • The incidence and natural history of type i and II endoleak: A 5 year follow-up assessment with color duplex ultrasound scan
    • Parent NF, Meier GH, Godxiachvili V, LeSar CL, Parker FM, Carter KA, et al. The incidence and natural history of type I and II endoleak: a 5 year follow-up assessment with color duplex ultrasound scan. J Vasc Surg 2002;35:474-81.
    • (2002) J Vasc Surg , vol.35 , pp. 474-481
    • Parent, N.F.1    Meier, G.H.2    Godxiachvili, V.3    Lesar, C.L.4    Parker, F.M.5    Carter, K.A.6
  • 16
    • 0037285780 scopus 로고    scopus 로고
    • Intrasac flow velocities predict sealing of type II endoleaks after endovascular abdominal aortic aneurysm repair
    • Arko FR, Konstantinos FA, Siedel SA, Johnson BL, Drake AR, Fogarty TJ, et al. Intrasac flow velocities predict sealing of type II endoleaks after endovascular abdominal aortic aneurysm repair. J Vasc Surg 2003;37: 8-15.
    • (2003) J Vasc Surg , vol.37 , pp. 8-15
    • Arko, F.R.1    Konstantinos, F.A.2    Siedel, S.A.3    Johnson, B.L.4    Drake, A.R.5    Fogarty, T.J.6
  • 17
    • 70350475525 scopus 로고    scopus 로고
    • Endoleak after endovascular aneurysm repair: Duplex ultrasound imaging is better than computed tomography at determining the need for interventon
    • Schmieder GC, Stout CL, Stokes GK, Parent FN, Panneton JM. Endoleak after endovascular aneurysm repair: duplex ultrasound imaging is better than computed tomography at determining the need for interventon. J Vasc Surg 2009;50:1012-8.
    • (2009) J Vasc Surg , vol.50 , pp. 1012-1018
    • Schmieder, G.C.1    Stout, C.L.2    Stokes, G.K.3    Parent, F.N.4    Panneton, J.M.5
  • 18
    • 70350573366 scopus 로고    scopus 로고
    • Duplex ultrasound imaging alone is sufficient for mid-term endovascular aneurysm repair surveillance: A cost analysis study and prospective comparison with computed tomography scan
    • Beeman BR, Doctor LM, Doerr K, McAfee-Bennett S, Dougherty MJ, Calligaro KD. Duplex ultrasound imaging alone is sufficient for mid-term endovascular aneurysm repair surveillance: a cost analysis study and prospective comparison with computed tomography scan. J Vasc Surg 2009;50:1019-24.
    • (2009) J Vasc Surg , vol.50 , pp. 1019-1024
    • Beeman, B.R.1    Doctor, L.M.2    Doerr, K.3    McAfee-Bennett, S.4    Dougherty, M.J.5    Calligaro, K.D.6
  • 19
    • 33846538061 scopus 로고    scopus 로고
    • Initial results of wireless pressure sensing for endovascular aneursym repair: The APEX Trial-Acute Pressure Measurement to Confirm Aneursym Sac Exclusion
    • Ohki T, Ouriel K, Silveira PG, Katzen B, White R, Criado F, et al. Initial results of wireless pressure sensing for endovascular aneursym repair: the APEX Trial-Acute Pressure Measurement to Confirm Aneursym Sac Exclusion. J Vasc Surg 2007;45:236-42.
    • (2007) J Vasc Surg , vol.45 , pp. 236-242
    • Ohki, T.1    Ouriel, K.2    Silveira, P.G.3    Katzen, B.4    White, R.5    Criado, F.6
  • 20
    • 10744231928 scopus 로고    scopus 로고
    • Type II endoleak after endovascular abdominal aortic aneurysm repair: A conservative approach with selective intervention is safe and cost-effective
    • Steinmetz E, Rubin BG, Sanchez LA, Choi ET, Geraghty PJ, Baty J, et al. Type II endoleak after endovascular abdominal aortic aneurysm repair: a conservative approach with selective intervention is safe and cost-effective. J Vasc Surg 2004;39:306-13.
    • (2004) J Vasc Surg , vol.39 , pp. 306-313
    • Steinmetz, E.1    Rubin, B.G.2    Sanchez, L.A.3    Choi, E.T.4    Geraghty, P.J.5    Baty, J.6
  • 21
    • 33747883395 scopus 로고    scopus 로고
    • An 8-year experience with type II endoleaks: Natural history suggests selective intervention is a safe approach
    • Silverberg D, Baril DT, Ellozy SH, Carroccio A, Greyrose SE, Lookstein RA, et al. An 8-year experience with type II endoleaks: natural history suggests selective intervention is a safe approach. J Vasc Surg 2006;44:453-9.
    • (2006) J Vasc Surg , vol.44 , pp. 453-459
    • Silverberg, D.1    Baril, D.T.2    Ellozy, S.H.3    Carroccio, A.4    Greyrose, S.E.5    Lookstein, R.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.