메뉴 건너뛰기




Volumn 67, Issue 6, 2012, Pages 1644-1655

Motion correction for myocardial T1 mapping using image registration with synthetic image estimation

Author keywords

cardiac MRI; image registration; MOLLI; motion correction; T1 mapping

Indexed keywords

HOSPITAL DATA PROCESSING; IMAGE REGISTRATION; MAGNETIC RESONANCE IMAGING; MAPPING; PATIENT REHABILITATION; RECOVERY;

EID: 84861231992     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.23153     Document Type: Article
Times cited : (193)

References (33)
  • 1
    • 0033911228 scopus 로고    scopus 로고
    • Magnetic resonance imaging in patients with cardiomyopathies: When and why
    • Schulz-Menger J, Friedrich MG,. Magnetic resonance imaging in patients with cardiomyopathies: when and why. Herz 2000; 25: 384-391.
    • (2000) Herz , vol.25 , pp. 384-391
    • Schulz-Menger, J.1    Friedrich, M.G.2
  • 3
    • 77954762396 scopus 로고    scopus 로고
    • Equilibrium contrast cardiovascular magnetic resonance for the measurement of diffuse myocardial fibrosis: Preliminary validation in humans
    • Flett AS, Hayward MP, Ashworth MT, Hansen MS, Taylor AM, Elliott PM, McGregor C, Moon JC,. Equilibrium contrast cardiovascular magnetic resonance for the measurement of diffuse myocardial fibrosis: preliminary validation in humans. Circulation 2010; 122: 138-144.
    • (2010) Circulation , vol.122 , pp. 138-144
    • Flett, A.S.1    Hayward, M.P.2    Ashworth, M.T.3    Hansen, M.S.4    Taylor, A.M.5    Elliott, P.M.6    McGregor, C.7    Moon, J.C.8
  • 6
    • 84880107225 scopus 로고    scopus 로고
    • A comparison of methods for determining the partition coefficient of gadolinium in the myocardium using T1 mapping
    • Janardhanan R, Jiji RS, Brooks J, Epstein FH, Kramer CM, Salerno M,. A comparison of methods for determining the partition coefficient of gadolinium in the myocardium using T1 mapping. J Cardiovasc Magn Reson 2011; 13 (Suppl 1): 77.
    • (2011) J Cardiovasc Magn Reson , vol.13 , Issue.SUPPL. 1 , pp. 77
    • Janardhanan, R.1    Jiji, R.S.2    Brooks, J.3    Epstein, F.H.4    Kramer, C.M.5    Salerno, M.6
  • 7
    • 84860919389 scopus 로고    scopus 로고
    • Quantification of acute myocardial injury by ShMOLLI T1-Mapping, T2-weighted and late gadolinium imaging in patients presenting with chest pain, positive troponins and non-obstructive coronary arteries
    • Ferreira VM, Piechnik SK, Dall'Armellina E, Karamitsos TD, Francis JM, Friedrich MG, Robson MD, Neubauer S,. Quantification of acute myocardial injury by ShMOLLI T1-Mapping, T2-weighted and late gadolinium imaging in patients presenting with chest pain, positive troponins and non-obstructive coronary arteries. J Cardiovasc Magn Reson 2011; 13 (Suppl 1): 114.
    • (2011) J Cardiovasc Magn Reson , vol.13 , Issue.SUPPL. 1 , pp. 114
    • Ferreira, V.M.1    Piechnik, S.K.2    Dall'Armellina, E.3    Karamitsos, T.D.4    Francis, J.M.5    Friedrich, M.G.6    Robson, M.D.7    Neubauer, S.8
  • 9
    • 70449411160 scopus 로고    scopus 로고
    • Improved signal spoiling in fast radial gradient-echo imaging: Applied to accurate T1 mapping and flip angle correction
    • Lin W, Song HK,. Improved signal spoiling in fast radial gradient-echo imaging: applied to accurate T1 mapping and flip angle correction. Magn Reson Med 2009; 62: 1185-1194.
    • (2009) Magn Reson Med , vol.62 , pp. 1185-1194
    • Lin, W.1    Song, H.K.2
  • 11
    • 0035119404 scopus 로고    scopus 로고
    • Measurement of the gadopentetate dimeglumine partition coefficient in human myocardium in vivo: Normal distribution and elevation in acute and chronic infarction
    • Flacke SJ, Fischer SE, Lorenz CH,. Measurement of the gadopentetate dimeglumine partition coefficient in human myocardium in vivo: normal distribution and elevation in acute and chronic infarction. Radiology 2001; 218: 703-710.
    • (2001) Radiology , vol.218 , pp. 703-710
    • Flacke, S.J.1    Fischer, S.E.2    Lorenz, C.H.3
  • 12
    • 79952777530 scopus 로고    scopus 로고
    • Shortened modified Look-Locker inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold
    • Piechnik S, Ferreira V, Dall'Armellina E, Cochlin L, Greiser A, Neubauer S, Robson M,. Shortened modified Look-Locker inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold. J Cardiovasc Magn Reson 2010; 12 (Suppl 1): 69.
    • (2010) J Cardiovasc Magn Reson , vol.12 , Issue.SUPPL. 1 , pp. 69
    • Piechnik, S.1    Ferreira, V.2    Dall'Armellina, E.3    Cochlin, L.4    Greiser, A.5    Neubauer, S.6    Robson, M.7
  • 16
    • 73149123166 scopus 로고    scopus 로고
    • High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting
    • Kellman P, Chefd'hotel C, Lorenz CH, Mancini C, Arai AE, McVeigh ER,. High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting. Magn Reson Med 2009; 62: 1557-1564.
    • (2009) Magn Reson Med , vol.62 , pp. 1557-1564
    • Kellman, P.1    Chefd'Hotel, C.2    Lorenz, C.H.3    Mancini, C.4    Arai, A.E.5    McVeigh, E.R.6
  • 19
    • 34547811361 scopus 로고    scopus 로고
    • Motion corrected free-breathing delayed-enhancement imaging of myocardial infarction using nonrigid registration
    • Ledesma-Carbayo MJ, Kellman P, Arai AE, McVeigh ER,. Motion corrected free-breathing delayed-enhancement imaging of myocardial infarction using nonrigid registration. J Magn Reson Imaging 2007; 26: 184-190.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 184-190
    • Ledesma-Carbayo, M.J.1    Kellman, P.2    Arai, A.E.3    McVeigh, E.R.4
  • 20
    • 0006973164 scopus 로고
    • Error analysis for optimized inversion recovery spin-lattice relaxation measurements
    • Sass M, Ziessow D,. Error analysis for optimized inversion recovery spin-lattice relaxation measurements. J Magn Reson 1977; 25: 263-276.
    • (1977) J Magn Reson , vol.25 , pp. 263-276
    • Sass, M.1    Ziessow, D.2
  • 24
    • 0032209062 scopus 로고    scopus 로고
    • Feature detection with automatic scale selection
    • Lindeberg T,. Feature detection with automatic scale selection. Int J Comput Vision 1998; 30: 79-116.
    • (1998) Int J Comput Vision , vol.30 , pp. 79-116
    • Lindeberg, T.1
  • 26
    • 0000238336 scopus 로고
    • A simplex method for function minimization
    • Nelder JA, Mead R,. A simplex method for function minimization. Comput J 1965; 7: 308-313.
    • (1965) Comput J , vol.7 , pp. 308-313
    • Nelder, J.A.1    Mead, R.2
  • 27
    • 0000169232 scopus 로고
    • An algorithm for least-squares estimation of nonlinear parameters
    • Marquardt DW,. An algorithm for least-squares estimation of nonlinear parameters. J Soc Ind Appl Math 1963; 11: 431-441.
    • (1963) J Soc Ind Appl Math , vol.11 , pp. 431-441
    • Marquardt, D.W.1
  • 28
    • 0000250265 scopus 로고
    • Measures of the amount of ecologic association between species
    • Dice LR,. Measures of the amount of ecologic association between species. Ecology 1945; 26: 297-302.
    • (1945) Ecology , vol.26 , pp. 297-302
    • Dice, L.R.1
  • 29
  • 32
    • 70149100453 scopus 로고    scopus 로고
    • Application of the Karhunen-Loeve transform temporal image filter to reduce noise in real-time cardiac cine MRI
    • Ding Y, Chung Y-C, Raman SV, Simonetti OP,. Application of the Karhunen-Loeve transform temporal image filter to reduce noise in real-time cardiac cine MRI. Phys Med Biol 2009; 54: 3909.
    • (2009) Phys Med Biol , vol.54 , pp. 3909
    • Ding, Y.1    Chung, Y.-C.2    Raman, S.V.3    Simonetti, O.P.4
  • 33
    • 41849129269 scopus 로고    scopus 로고
    • Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging
    • Kellman P, Chefd'hotel C, Lorenz CH, Mancini C, Arai AE, McVeigh ER,. Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging. Magn Reson Med 2008; 59: 771-778.
    • (2008) Magn Reson Med , vol.59 , pp. 771-778
    • Kellman, P.1    Chefd'Hotel, C.2    Lorenz, C.H.3    Mancini, C.4    Arai, A.E.5    McVeigh, E.R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.