메뉴 건너뛰기




Volumn 62, Issue 5, 2009, Pages 1185-1194

Improved signal spoiling in fast radial gradient-echo imaging: Applied to accurate t1 mapping and flip angle correction

Author keywords

B1 mapping; Radial imaging; Random spoiling; RF spoiling; T1 mapping

Indexed keywords

DATA ACQUISITION;

EID: 70449411160     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22089     Document Type: Article
Times cited : (21)

References (22)
  • 1
    • 0026011540 scopus 로고
    • Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts
    • Tofts PS, Kermode AG. Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts. Magn Reson Med 1991;17:357-367.
    • (1991) Magn Reson Med , vol.17 , pp. 357-367
    • Tofts, P.S.1    Kermode, A.G.2
  • 2
    • 0025985527 scopus 로고
    • Spoiling of transverse magnetization in steady-state sequences
    • Zur Y, Wood ML, Neuringer LJ. Spoiling of transverse magnetization in steady-state sequences. Magn Reson Med 1991;21:251-263.
    • (1991) Magn Reson Med , vol.21 , pp. 251-263
    • Zur, Y.1    Wood, M.L.2    Neuringer, L.J.3
  • 3
    • 26844571284 scopus 로고    scopus 로고
    • New insights into the mechanisms of signal formation in RF-spoiled gradient echo sequences
    • DOI 10.1002/mrm.20652
    • Denolin V, Azizieh C, Metens T. New insights into the mechanisms of signal formation in RF-spoiled gradient echo sequences. Magn Reson Med 2005;54:937-954. (Pubitemid 41457066)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.4 , pp. 937-954
    • Denolin, V.1    Azizieh, C.2    Metens, T.3
  • 5
    • 0037370514 scopus 로고    scopus 로고
    • 2 mapping using gradient recalled acquisition in the steady state
    • 2 mapping using gradient recalled acquisition in the steady state. Magn Reson Med 2003;49:515-526.
    • (2003) Magn Reson Med , vol.49 , pp. 515-526
    • Deoni, S.C.1    Rutt, B.K.2    Peters, T.M.3
  • 6
    • 33644813235 scopus 로고    scopus 로고
    • 1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity
    • 1 mapping by variable flip angles: accurate and precise measurements in the presence of radiofrequency field inhomogeneity. Magn Reson Med 2006;55:566-574.
    • (2006) Magn Reson Med , vol.55 , pp. 566-574
    • Cheng, H.M.1    Wright, G.A.2
  • 7
    • 33846078031 scopus 로고    scopus 로고
    • Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field
    • Yarnyth VL. Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn Reson Med 2007;57:192-200.
    • (2007) Magn Reson Med , vol.57 , pp. 192-200
    • Yarnyth, V.L.1
  • 12
    • 0027450251 scopus 로고
    • Consistent projection reconstruction (CPR) techniques for MRI
    • Glover GH, Noll DC. Consistent projection reconstruction (CPR) techniques for MRI. Magn Reson Med 1993;29:345-351.
    • (1993) Magn Reson Med , vol.29 , pp. 345-351
    • Glover, G.H.1    Noll, D.C.2
  • 15
  • 16
    • 0030938146 scopus 로고    scopus 로고
    • Steady state effects in fast gradient echo magnetic resonance imaging
    • DOI 10.1002/mrm.1910370414
    • Duyn JH. Steady state effects in fast gradient echo magnetic resonance imaging. Magn Reson Med 1997;37:559-568. (Pubitemid 27146834)
    • (1997) Magnetic Resonance in Medicine , vol.37 , Issue.4 , pp. 559-568
    • Duyn, J.H.1
  • 17
    • 4243861497 scopus 로고
    • Steady-state management in fast low-angle imaging
    • Montreal, Quebec, Canada
    • Darrasse L, Mao L, Saint-Jalmes H. Steady-state management in fast low-angle imaging. In: SMRM Book of Abstracts, Montreal, Quebec, Canada; 1986. pp. 944-945.
    • (1986) SMRM Book of Abstracts , pp. 944-945
    • Darrasse, L.1    Mao, L.2    Saint-Jalmes, H.3
  • 18
    • 0000629553 scopus 로고
    • Phase and intensity anomalies in Fourier transform NMR
    • Freeman R, Hill HDW. Phase and intensity anomalies in Fourier transform NMR. J Magn Reson (1969) 1971;4:366-383.
    • (1971) J Magn Reson (1969) , vol.4 , pp. 366-383
    • Freeman, R.1    Hill, H.D.W.2
  • 19
    • 46849105903 scopus 로고    scopus 로고
    • Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging
    • DOI 10.1002/mrm.21614
    • Leupold J, Hennig J, Scheffler K. Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging. Magn Reson Med 2008;60:119-127. (Pubitemid 351956616)
    • (2008) Magnetic Resonance in Medicine , vol.60 , Issue.1 , pp. 119-127
    • Leupold, J.1    Hennig, J.2    Scheffler, K.3
  • 22
    • 12144277049 scopus 로고    scopus 로고
    • 2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2
    • 2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2. Magn Reson Med 2005;53:237-241.
    • (2005) Magn Reson Med , vol.53 , pp. 237-241
    • Deoni, S.C.1    Peters, T.M.2    Rutt, B.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.