메뉴 건너뛰기




Volumn 27, Issue 1, 2011, Pages 15-24

Effect of new generation refrigerant selection to the low temperature circuit efficiency in cascade systems

Author keywords

Efficiency; Exergy; R123; R215 218 290 mixture; Refrigeration

Indexed keywords

CASCADE REFRIGERATION SYSTEMS; CASCADE SYSTEMS; CIRCUIT EFFICIENCY; EXERGETIC PERFORMANCE; LOW TEMPERATURES; R123; THERMODYNAMIC EQUATIONS;

EID: 84861128024     PISSN: 1308772X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (13)

References (31)
  • 2
    • 0036883483 scopus 로고    scopus 로고
    • Experiment and simulation on the performance of an autocascade refrigeration system using carbon dioxide as a refrigerant
    • Kim SG, Kim MS. Experiment and simulation on the performance of an autocascade refrigeration system using carbon dioxide as a refrigerant. Int J Refrigeration 2002;25:1093-1101.
    • (2002) Int J Refrigeration , vol.25 , pp. 1093-1101
    • Kim, S.G.1    Kim, M.S.2
  • 3
    • 33748044010 scopus 로고    scopus 로고
    • 3cascade refrigeration systems
    • Lee TS, Liu CH, Chen TW. Thermodynamic analysis of optimal condensing temperature of cascade-condenser in CO2/NH3cascade refrigeration systems. Int J Refrigeration 2006;29:1100-1108.
    • (2006) Int J Refrigeration , vol.29 , pp. 1100-1108
    • Lee, T.S.1    Liu, C.H.2    Chen, T.W.3
  • 6
    • 4344616942 scopus 로고    scopus 로고
    • A finite time analysis of a cascade refrigeration system using alternative refrigerants
    • Agnew B, Ameli SM. A finite time analysis of a cascade refrigeration system using alternative refrigerants. Appl Therm Eng 2004;24:2557-2565.
    • (2004) Appl Therm Eng , vol.24 , pp. 2557-2565
    • Agnew, B.1    Ameli, S.M.2
  • 7
    • 67349141413 scopus 로고    scopus 로고
    • 2 cascade system for refrigeration and heating
    • Bhattacharyya S, Garaia A, Sarkarb J. Thermodynamic analysis and optimization of a novel N2O-CO2 cascade system for refrigeration and heating. Int J Refrigeration 2009;32:1077-1084.
    • (2009) Int J Refrigeration , vol.32 , pp. 1077-1084
    • Bhattacharyya, S.1    Garaia, A.2    Sarkarb, J.3
  • 8
    • 34247499434 scopus 로고    scopus 로고
    • 8 system
    • Bhattacharyya S, Bose S, Sarkar J. Exergy maximization of cascade refrigeration cycles and its numerical verification for a transcritical CO2-C3H8 system. Int J Refrigeration 2007;30:624-632.
    • (2007) Int J Refrigeration , vol.30 , pp. 624-632
    • Bhattacharyya, S.1    Bose, S.2    Sarkar, J.3
  • 9
    • 61349084199 scopus 로고    scopus 로고
    • 3 cascade refrigeration system for cooling applications at low temperatures
    • Dopazo JA, Seara JF, Sieres J, Uhía FJ. Theoretical analysis of a CO2-NH3 cascade refrigeration system for cooling applications at low temperatures. Appl Therm Eng 2009;29:1577-1583.
    • (2009) Appl Therm Eng , vol.29 , pp. 1577-1583
    • Dopazo, J.A.1    Seara, J.F.2    Sieres, J.3    Uhía, F.J.4
  • 10
    • 84861921508 scopus 로고    scopus 로고
    • http://www.isceon-refrigerants.co.uk/
  • 11
    • 0030109535 scopus 로고
    • Thermal conductivity and viscosity of 2-2-dichloro-1,1,1-trifluoroethane, (HCFC-123)
    • Tanaka Y, Sotani T. Thermal conductivity and viscosity of 2-2-dichloro-1,1,1-trifluoroethane, (HCFC-123). Int J Thermal Physics 1966;17:293-328.
    • (1966) Int J Thermal Physics , vol.17 , pp. 293-328
    • Tanaka, Y.1    Sotani, T.2
  • 13
    • 21844510918 scopus 로고
    • An international standard equation of state for the thermodynamic properties of refrigerant R123
    • Younglove BA, McLinden MO. An international standard equation of state for the thermodynamic properties of refrigerant R123. J Phys Chem Ref Data 1994;23:731-779.
    • (1994) J Phys Chem Ref Data , vol.23 , pp. 731-779
    • Younglove, B.A.1    McLinden, M.O.2
  • 14
    • 75849139991 scopus 로고    scopus 로고
    • Energy and exergy analysis of vapor compression refrigeration system using hydrocarbons, R290, R600, R600a and R1270
    • Bayrakci HC, Ozgur AE. Energy and exergy analysis of vapor compression refrigeration system using hydrocarbons, R290, R600, R600a and R1270. Int J Energ Res 2009;33:1070-1075.
    • (2009) Int J Energ Res , vol.33 , pp. 1070-1075
    • Bayrakci, H.C.1    Ozgur, A.E.2
  • 15
    • 35548994961 scopus 로고    scopus 로고
    • Computational and Experimental Investigation of Low ODP and Low GWP HCFC-123 and HC-290 Refrigerant Mixture Alternate to CFC-12
    • Kumar KS, Rajagopal K. Computational and Experimental Investigation of Low ODP and Low GWP HCFC-123 and HC-290 Refrigerant Mixture Alternate to CFC-12. Energy Convers Manage 2007;48:3053-3062.
    • (2007) Energy Convers Manage , vol.48 , pp. 3053-3062
    • Kumar, K.S.1    Rajagopal, K.2
  • 16
    • 84861952025 scopus 로고    scopus 로고
    • DuPont Refrigerant Expert 3.0, Cycle Calculation Program Info Files
    • DuPont Refrigerant Expert 3.0, Cycle Calculation Program Info Files, 2007.
    • (2007)
  • 17
    • 84861138604 scopus 로고    scopus 로고
    • The performance of a cool storage system in various operation conditions and its economic analysis
    • Basaran T, Sumbul N. The performance of a cool storage system in various operation conditions and its economic analysis. Energy Educ Sci Technol Part A 2011;26:251-264.
    • (2011) Energy Educ Sci Technol Part A , vol.26 , pp. 251-264
    • Basaran, T.1    Sumbul, N.2
  • 18
    • 77957321190 scopus 로고    scopus 로고
    • Performance evaluation of a 250 L household refrigerator
    • Cerci Y, Ekin AB. Performance evaluation of a 250 L household refrigerator. Energy Educ Sci Technol Part A 2010;26:25-36.
    • (2010) Energy Educ Sci Technol Part A , vol.26 , pp. 25-36
    • Cerci, Y.1    Ekin, A.B.2
  • 19
    • 33845343603 scopus 로고    scopus 로고
    • Progress and recent trends in biofuels
    • Demirbas A. Progress and recent trends in biofuels. Prog Energy Combus Sci 2007;33:1-18.
    • (2007) Prog Energy Combus Sci , vol.33 , pp. 1-18
    • Demirbas, A.1
  • 20
    • 77957293336 scopus 로고    scopus 로고
    • A mathematical model for condensation of bubbles injected through an orifice into subcooled water
    • Bugutekin A, Yilmaz M, Kentli A, Isikan MO. A mathematical model for condensation of bubbles injected through an orifice into subcooled water. Energy Educ Sci Technol Part A 2010;24:151-171.
    • (2010) Energy Educ Sci Technol Part A , vol.24 , pp. 151-171
    • Bugutekin, A.1    Yilmaz, M.2    Kentli, A.3    Isikan, M.O.4
  • 21
    • 77957309221 scopus 로고    scopus 로고
    • Concept of energy conversion in engineering education
    • Demirbas A. Concept of energy conversion in engineering education. Energy Educ Sci Technol Part B 2009;1:183-197.
    • (2009) Energy Educ Sci Technol Part B , vol.1 , pp. 183-197
    • Demirbas, A.1
  • 22
    • 67650273583 scopus 로고    scopus 로고
    • Currency of district cooling systems and alternative energy sources
    • Ulusarslan D, Gemici Z, Teke I. Currency of district cooling systems and alternative energy sources. Energy Educ Sci Technol Part A 2009;23:31-53.
    • (2009) Energy Educ Sci Technol Part A , vol.23 , pp. 31-53
    • Ulusarslan, D.1    Gemici, Z.2    Teke, I.3
  • 23
    • 84861923066 scopus 로고    scopus 로고
    • Experimental investigation of the effect of absorber pre-cooler to the performance of the absorption cooling system
    • Gungor C, Kaya D. Experimental investigation of the effect of absorber pre-cooler to the performance of the absorption cooling system. Energy Educ Sci Technol Part A 2009;24:71-83.
    • (2009) Energy Educ Sci Technol Part A , vol.24 , pp. 71-83
    • Gungor, C.1    Kaya, D.2
  • 24
    • 81155123577 scopus 로고    scopus 로고
    • Social, economic, environmental and policy aspects of biofuels
    • Demirbas A. Social, economic, environmental and policy aspects of biofuels. Energy Educ Sci Technol Part B 2010;2:75-109.
    • (2010) Energy Educ Sci Technol Part B , vol.2 , pp. 75-109
    • Demirbas, A.1
  • 25
    • 78650979070 scopus 로고    scopus 로고
    • Theoretical and experimental analysis of the solar energy gain of transparent insulated external wall in climatic conditions of Izmir
    • Ozbalta TG, Ozbalta N. Theoretical and experimental analysis of the solar energy gain of transparent insulated external wall in climatic conditions of Izmir. Energy Educ Sci Technol Part A 2010;25:69-86.
    • (2010) Energy Educ Sci Technol Part A , vol.25 , pp. 69-86
    • Ozbalta, T.G.1    Ozbalta, N.2
  • 26
    • 77957321390 scopus 로고    scopus 로고
    • Energy and economic analyses of insulated exterior walls for four different city in Turkey
    • Balo F. Energy and economic analyses of insulated exterior walls for four different city in Turkey. Energy Educ Sci Technol Part A 2011;26:175-188.
    • (2011) Energy Educ Sci Technol Part A , vol.26 , pp. 175-188
    • Balo, F.1
  • 27
    • 82355173999 scopus 로고    scopus 로고
    • Energetic and exergetic approach to vapor compression refrigeration cycle with two-stage and intercooler for new refrigerants
    • Dikmen E, Sencan A, Selbas R. Energetic and exergetic approach to vapor compression refrigeration cycle with two-stage and intercooler for new refrigerants. Energy Educ Sci Technol Part A 2011;26:205-219.
    • (2011) Energy Educ Sci Technol Part A , vol.26 , pp. 205-219
    • Dikmen, E.1    Sencan, A.2    Selbas, R.3
  • 28
    • 77957298192 scopus 로고    scopus 로고
    • Experimental investigation of capacitor effects on performance parameters planning for household refrigerator and energy systems
    • Cerci Y. Experimental investigation of capacitor effects on performance parameters planning for household refrigerator and energy systems. Energy Educ Sci Technol Part A 2009;24:15-24.
    • (2009) Energy Educ Sci Technol Part A , vol.24 , pp. 15-24
    • Cerci, Y.1
  • 29
    • 67650273583 scopus 로고    scopus 로고
    • Currency of district cooling systems and alternative energy sources
    • Ulusarslan D, Gemici Z, Teke I. Currency of district cooling systems and alternative energy sources. Energy Educ Sci Technol Part A 2009;23:31-53.
    • (2009) Energy Educ Sci Technol Part A , vol.23 , pp. 31-53
    • Ulusarslan, D.1    Gemici, Z.2    Teke, I.3
  • 30
    • 84861141887 scopus 로고    scopus 로고
    • Thermal simulation of retrofits to existing mass housing in Turkey for energy efficiency
    • Yildiz Y, Arsan ZD. Thermal simulation of retrofits to existing mass housing in Turkey for energy efficiency. Energy Educ Sci Technol Part A 2011;26:189-203.
    • (2011) Energy Educ Sci Technol Part A , vol.26 , pp. 189-203
    • Yildiz, Y.1    Arsan, Z.D.2
  • 31
    • 84861174943 scopus 로고    scopus 로고
    • Performance evaluation of variable speed refrigeration system with artificial neural networks
    • Kizilkan O. Performance evaluation of variable speed refrigeration system with artificial neural networks. Energy Educ Sci Technol Part A 2011;26:239-250.
    • (2011) Energy Educ Sci Technol Part A , vol.26 , pp. 239-250
    • Kizilkan, O.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.