메뉴 건너뛰기




Volumn 26, Issue 2, 2011, Pages 205-219

Energetic and exergetic approach to vapor compression refrigeration cycle with two-stage and intercooler for new refrigerants

Author keywords

COP; Exergy analysis; Refrigeration system; Two stage; Vapor compression refrigeration

Indexed keywords

COEFFICIENT OF PERFORMANCE; COP; EXERGETIC EFFICIENCY; EXERGY ANALYSIS; INTERCOOLERS; IRREVERSIBILITY RATE; NEW REFRIGERANTS; OPERATING CONDITION; REFRIGERATION SYSTEM; SECOND LAW ANALYSIS; TWO-STAGE; VAPOR-COMPRESSION REFRIGERATION CYCLE;

EID: 82355173999     PISSN: 1308772X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (33)

References (28)
  • 1
    • 54949085060 scopus 로고    scopus 로고
    • Thermo-economic optimization of superheating and sub-cooling heat exchangers in vapor-compressed refrigeration system
    • Ozkaymak M, Kurt H, Recebli Z. Thermo-economic optimization of superheating and sub-cooling heat exchangers in vapor-compressed refrigeration system. Int J Energy Res 2008;32:634-647.
    • (2008) Int J Energy Res , vol.32 , pp. 634-647
    • Ozkaymak, M.1    Kurt, H.2    Recebli, Z.3
  • 2
    • 24944547345 scopus 로고    scopus 로고
    • A comparative study of water as a refrigerant with some current refrigerants
    • Kilicarslan A, Müller N. A comparative study of water as a refrigerant with some current refrigerants. Int J Energy Res 2005;29:947-959.
    • (2005) Int J Energy Res , vol.29 , pp. 947-959
    • Kilicarslan, A.1    Müller, N.2
  • 3
    • 33745835788 scopus 로고    scopus 로고
    • Effect of saturation-temperature on the performance of a vapour-compression refrigeration-cycle working on different refrigerants using exergy method
    • Kopac M, Zemher B. Effect of saturation-temperature on the performance of a vapour-compression refrigeration-cycle working on different refrigerants using exergy method. Int J Energy Res 2006;30:729-740.
    • (2006) Int J Energy Res , vol.30 , pp. 729-740
    • Kopac, M.1    Zemher, B.2
  • 4
    • 0347974049 scopus 로고    scopus 로고
    • Exergy analysis of vapor compression refrigeration systems
    • Yumrutas R, Kunduz M, Kanoglu M. Exergy analysis of vapor compression refrigeration systems. Exergy 2002;2:266-272.
    • (2002) Exergy , vol.2 , pp. 266-272
    • Yumrutas, R.1    Kunduz, M.2    Kanoglu, M.3
  • 5
    • 1542643834 scopus 로고    scopus 로고
    • Experimental comparison of R22 with R417A performance in a vapour compression refrigeration plant subjected to a cold store
    • Aprea C, Renno C. Experimental comparison of R22 with R417A performance in a vapour compression refrigeration plant subjected to a cold store. Energy Convers Manage 2004;45:1807-1819.
    • (2004) Energy Convers Manage , vol.45 , pp. 1807-1819
    • Aprea, C.1    Renno, C.2
  • 6
    • 3342939446 scopus 로고    scopus 로고
    • Performance analysis of vapour compression refrigeration with R22/R124/R152a refrigerant
    • Kiatsiriroat T, Thalang KN. Performance analysis of vapour compression refrigeration with R22/R124/R152a refrigerant. Int J Energy Res 1997;21:221-232.
    • (1997) Int J Energy Res , vol.21 , pp. 221-232
    • Kiatsiriroat, T.1    Thalang, K.N.2
  • 7
    • 33845502922 scopus 로고    scopus 로고
    • Simulation and exergy-method analysis of an industrial refrigeration cycle used in NGL recovery units
    • Mehrpooya M, Jarrahian A, Pishvaie MR. Simulation and exergy-method analysis of an industrial refrigeration cycle used in NGL recovery units. Int J Energy Res 2006;30:1336-1351.
    • (2006) Int J Energy Res , vol.30 , pp. 1336-1351
    • Mehrpooya, M.1    Jarrahian, A.2    Pishvaie, M.R.3
  • 8
    • 48249117971 scopus 로고    scopus 로고
    • Performance and exergetic analysis of vapor compression refrigeration system with an internal heat exchanger using a hydrocarbon, isobutane (R600a)
    • Kabul A, Kizilkan O, Yakut AK. Performance and exergetic analysis of vapor compression refrigeration system with an internal heat exchanger using a hydrocarbon, isobutane (R600a). Int J Energy Res 2008;32:824-836.
    • (2008) Int J Energy Res , vol.32 , pp. 824-836
    • Kabul, A.1    Kizilkan, O.2    Yakut, A.K.3
  • 9
    • 48649105086 scopus 로고    scopus 로고
    • Theoretical analysis of a vapour compression refrigeration system with R502, R404A and R507A
    • Arora A, Kaushik SC. Theoretical analysis of a vapour compression refrigeration system with R502, R404A and R507A. Inter J Refriger 2008;31:998-1005.
    • (2008) Inter J Refriger , vol.31 , pp. 998-1005
    • Arora, A.1    Kaushik, S.C.2
  • 10
    • 0032194246 scopus 로고    scopus 로고
    • Design and rating of a two-stage vapor compression refrigeration system
    • Khan JR, Zubair SM. Design and rating of a two-stage vapor compression refrigeration system. Energy 1998;23:867-878.
    • (1998) Energy , vol.23 , pp. 867-878
    • Khan, J.R.1    Zubair, S.M.2
  • 11
    • 0032416039 scopus 로고    scopus 로고
    • Exergy-method analysis of a two-stage vapour-compression refrigeration-plants performance
    • Nikolaidis C, Probert D. Exergy-method analysis of a two-stage vapour-compression refrigeration-plants performance. Appl Energy 1998;60:241-256.
    • (1998) Appl Energy , vol.60 , pp. 241-256
    • Nikolaidis, C.1    Probert, D.2
  • 12
    • 33750691026 scopus 로고    scopus 로고
    • Performance investigation of transcritical carbon dioxide two-stage compression cycle with expander
    • Yang JL, Ma YT, Liu SC. Performance investigation of transcritical carbon dioxide two-stage compression cycle with expander. Energy 2007; 32:237-245.
    • (2007) Energy , vol.32 , pp. 237-245
    • Yang, J.L.1    Ma, Y.T.2    Liu, S.C.3
  • 13
    • 77957321190 scopus 로고    scopus 로고
    • Performance evaluation of a 250 L household refrigerator
    • Cerci Y, Ekin AB. Performance evaluation of a 250 L household refrigerator. Energy Educ Sci Technol Part A 2010;26:25-36.
    • (2010) Energy Educ Sci Technol Part A , vol.26 , pp. 25-36
    • Cerci, Y.1    Ekin, A.B.2
  • 14
    • 77957298192 scopus 로고    scopus 로고
    • Experimental investigation of capacitor effects on performance parameters planning for household refrigerator and energy systems
    • Cerci Y. Experimental investigation of capacitor effects on performance parameters planning for household refrigerator and energy systems. Energy Educ Sci Technol Part A 2009;24:15-24
    • (2009) Energy Educ Sci Technol Part A , vol.24 , pp. 15-24
    • Cerci, Y.1
  • 15
    • 0003475840 scopus 로고
    • Chapter 6. Department of Mechanical Engineering, Queen Mary College, University of London: London
    • Kotas TJ. The Exergy Method of Thermal Plant Analysis, Chapter 6. Department of Mechanical Engineering, Queen Mary College, University of London: London, 1985, pp. 197-205.
    • (1985) The Exergy Method of Thermal Plant Analysis , pp. 197-205
    • Kotas, T.J.1
  • 17
    • 0034301735 scopus 로고    scopus 로고
    • Thermodynamics, exergy and environmental impact
    • I. Thermodynamics, exergy and environmental impact. Energy Sources 2000;22:723-732.
    • (2000) Energy Sources , vol.22 , pp. 723-732
  • 18
    • 0347051807 scopus 로고    scopus 로고
    • Thermo-economic optimization of vapor compression refrigeration systems
    • Dincer I, Al-Otaibi DA, Kalyon M. Thermo-economic optimization of vapor compression refrigeration systems. Int Communic Heat Mass Trans 2004;31:95-107.
    • (2004) Int Communic Heat Mass Trans , vol.31 , pp. 95-107
    • Dincer, I.1    Al-Otaibi, D.A.2    Kalyon, M.3
  • 19
    • 10244226616 scopus 로고    scopus 로고
    • Exergy analysis of lithium bromide/water absorption systems
    • Sencan A, Yakut AK, Kalogirou SA, Exergy analysis of lithium bromide/water absorption systems. Renewable Energy 2005;30:645-657.
    • (2005) Renewable Energy , vol.30 , pp. 645-657
    • Sencan, A.1    Yakut, A.K.2    Kalogirou, S.A.3
  • 20
    • 33745851841 scopus 로고    scopus 로고
    • Thermoeconomic optimization of subcooled and superheated vapor compression refrigeration cycle
    • Selbas R, Kizilkan O, Sencan A. Thermoeconomic optimization of subcooled and superheated vapor compression refrigeration cycle. Energy 2006;31:2108-2128.
    • (2006) Energy , vol.31 , pp. 2108-2128
    • Selbas, R.1    Kizilkan, O.2    Sencan, A.3
  • 21
    • 33645943687 scopus 로고    scopus 로고
    • Thermodynamic analysis of subcooling and superheating effects of alternative refrigerants for vapour compression refrigeration cycles
    • Sencan A, Selbas R, Kizilkan O, Kalogirou SA. Thermodynamic analysis of subcooling and superheating effects of alternative refrigerants for vapour compression refrigeration cycles. Int J Energy Res 2006;30:323-347.
    • (2006) Int J Energy Res , vol.30 , pp. 323-347
    • Sencan, A.1    Selbas, R.2    Kizilkan, O.3    Kalogirou, S.A.4
  • 23
    • 77957311695 scopus 로고    scopus 로고
    • The environmental impact of optimum insulation thickness for external walls and flat roofs of building in Turkey's different degree-day regions
    • Ucar A. The environmental impact of optimum insulation thickness for external walls and flat roofs of building in Turkey's different degree-day regions. Energy Educ Sci Technol Part A 2009;24:49-69.
    • (2009) Energy Educ Sci Technol Part A , vol.24 , pp. 49-69
    • Ucar, A.1
  • 24
    • 84861987366 scopus 로고    scopus 로고
    • Parasitic energy savings in engines using nanolubricants
    • Saidur R, Lai YK. Parasitic energy savings in engines using nanolubricants. Energy Educ Sci Technol Part A 2010;26:61-74.
    • (2010) Energy Educ Sci Technol Part A , vol.26 , pp. 61-74
    • Saidur, R.1    Lai, Y.K.2
  • 25
    • 77957293336 scopus 로고    scopus 로고
    • A mathematical model for condensation of bubbles injected through an orifice into subcooled water
    • Bugutekin A, Yilmaz M, Kentli A, Isikan MO. A mathematical model for condensation of bubbles injected through an orifice into subcooled water. Energy Educ Sci Technol Part A 2010;24:151-171.
    • (2010) Energy Educ Sci Technol Part A , vol.24 , pp. 151-171
    • Bugutekin, A.1    Yilmaz, M.2    Kentli, A.3    Isikan, M.O.4
  • 26
    • 77953738172 scopus 로고    scopus 로고
    • Domestic energy savings: Investigation of optimum insulation thicknesses for the external wall of rural houses in Turkey
    • Bolukbasi A, Comakli K, Sahin S. Domestic energy savings: Investigation of optimum insulation thicknesses for the external wall of rural houses in Turkey. Energy Educ Sci Technol Part A 2009;24:25-37.
    • (2009) Energy Educ Sci Technol Part A , vol.24 , pp. 25-37
    • Bolukbasi, A.1    Comakli, K.2    Sahin, S.3
  • 27
    • 67650273583 scopus 로고    scopus 로고
    • Currency of district cooling systems and alternative energy sources
    • Ulusarslan D, Gemici Z, Teke I. Currency of district cooling systems and alternative energy sources. Energy Educ Sci Technol Part A 2009;23:31-53.
    • (2009) Energy Educ Sci Technol Part A , vol.23 , pp. 31-53
    • Ulusarslan, D.1    Gemici, Z.2    Teke, I.3
  • 28
    • 84861923066 scopus 로고    scopus 로고
    • Experimental investigation of the effect of absorber pre-cooler to the performance of the absorption cooling system
    • Gungor C, Kaya D. Experimental investigation of the effect of absorber pre-cooler to the performance of the absorption cooling system. Energy Educ Sci Technol Part A 2009;24:71-83.
    • (2009) Energy Educ Sci Technol Part A , vol.24 , pp. 71-83
    • Gungor, C.1    Kaya, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.