메뉴 건너뛰기




Volumn 25, Issue 8, 2002, Pages 1093-1101

Experiment and simulation on the performance of an autocascade refrigeration system using carbon dioxide as a refrigerant

Author keywords

Carbon dioxide; Cascade system; Compression system; Design; Measurement; Mixture; Modelling; Performance; Propane; R134a; Refrigerant; Refrigerating circuit; Refrigeration system

Indexed keywords

CARBON DIOXIDE; CASCADES (FLUID MECHANICS); COMPRESSORS; COMPUTER SIMULATION; MIXTURES; PROPANE; REFRIGERANTS;

EID: 0036883483     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0140-7007(01)00110-4     Document Type: Article
Times cited : (135)

References (14)
  • 1
    • 0009342753 scopus 로고
    • Revival of carbon dioxide as a refrigerant
    • Lorentzen G. Revival of carbon dioxide as a refrigerant. Int J Refrig. 17(5):1994;292-301.
    • (1994) Int J Refrig. , vol.17 , Issue.5 , pp. 292-301
    • Lorentzen, G.1
  • 2
    • 0032073496 scopus 로고    scopus 로고
    • 2-heat pump water heater: Characteristics, system design and experimental results
    • 2-heat pump water heater: characteristics, system design and experimental results. Int J Refrig. 21(3):1998;172-179.
    • (1998) Int J Refrig , vol.21 , Issue.3 , pp. 172-179
    • Nekså, P.1    Rekstad, H.2    Zakeri, G.R.3    Schiefloe, P.A.4
  • 9
    • 80052718344 scopus 로고    scopus 로고
    • 2 as a refrigerant
    • Paris: International Institute of Refrigeration
    • 2 as a refrigerant, IIR Bulletin, No. 1, Paris: International Institute of Refrigeration, 1999.
    • (1999) IIR Bulletin , vol.1
    • Kruse, H.1    Heidelck, R.2    Süss, J.3
  • 11
    • 26544455732 scopus 로고
    • Business News Publishing Company
    • Stoecker W.F. Industrial refrigeration, Vol. II. Business News Publishing Company, 1995. p. 319-25.
    • (1995) Industrial refrigeration , vol.2 , pp. 319-325
    • Stoecker, W.F.1
  • 12
    • 0005104163 scopus 로고    scopus 로고
    • Performance of autocascade refrigeration system using carbon dioxide and R134a
    • Natural Working Fluids'98, 2-5 June 1998; Oslo, Norway
    • Park S.N., Kim M.S. Performance of autocascade refrigeration system using carbon dioxide and R134a, In: Natural Working Fluids'98, Proceeings of the IIR-Gustav Lorentzen Conference, 2-5 June 1998; Oslo, Norway. 1998. p. 311-20.
    • (1998) Proceeings of the IIR-Gustav Lorentzen Conference , pp. 311-320
    • Park, S.N.1    Kim, M.S.2
  • 13
    • 0002818734 scopus 로고
    • A simplified cycle simulation model for the performance rating of refrigerants and refrigerant mixtures
    • Domanski P., McLinden M. A simplified cycle simulation model for the performance rating of refrigerants and refrigerant mixtures. Int J Refrig. 1992;15(2);81-8.
    • (1992) Int J Refrig , vol.15 , Issue.2 , pp. 81-88
    • Domanski, P.1    McLinden, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.