메뉴 건너뛰기




Volumn 48, Issue 12, 2007, Pages 3053-3062

Computational and experimental investigation of low ODP and low GWP HCFC-123 and HC-290 refrigerant mixture alternate to CFC-12

Author keywords

Alternate refrigerant; Global warming; Ozone depletion; R123 R290

Indexed keywords

ALTERNATIVE FUELS; BOILING POINT; DENSITY (SPECIFIC GRAVITY); GLOBAL WARMING; OZONE LAYER;

EID: 35548994961     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enconman.2007.05.021     Document Type: Article
Times cited : (45)

References (34)
  • 1
    • 35548980653 scopus 로고    scopus 로고
    • UNEP, Montreal protocol on substances that deplete the ozone layer, United Nations Environment Programme (UNEP); 1987.
  • 2
    • 35548952448 scopus 로고    scopus 로고
    • Kyoto protocol to the United Nations framework convention on climate change, United Nations (UN), NewYork, USA; 1997.
  • 3
    • 33344467309 scopus 로고    scopus 로고
    • Improved energy efficiency for CFC domestic refrigerators retrofitted with ozone-friendly HFC134a/HC refrigerant mixture
    • Joseph Sekhar S., Mohan Lal D., and Renganarayanan S. Improved energy efficiency for CFC domestic refrigerators retrofitted with ozone-friendly HFC134a/HC refrigerant mixture. Int J Therm Sci 43 3 (2004) 307-314
    • (2004) Int J Therm Sci , vol.43 , Issue.3 , pp. 307-314
    • Joseph Sekhar, S.1    Mohan Lal, D.2    Renganarayanan, S.3
  • 4
    • 35548979715 scopus 로고    scopus 로고
    • Report of the TEAP HFC and PFC Task Force, The implications to the Montreal protocol of the inclusion of HFCs and PFCs in the Kyoto protocol; October 1999.
  • 5
    • 35548993010 scopus 로고    scopus 로고
    • . 2006.
  • 6
    • 0033321712 scopus 로고    scopus 로고
    • Condensation heat transfer coefficients of enhanced tubes with alternative refrigerants for CFC-11 and CFC-12
    • Jung D., Kim C.-B., Cho S., and Song K. Condensation heat transfer coefficients of enhanced tubes with alternative refrigerants for CFC-11 and CFC-12. Int J Refrig 22 15 (1999) 548-557
    • (1999) Int J Refrig , vol.22 , Issue.15 , pp. 548-557
    • Jung, D.1    Kim, C.-B.2    Cho, S.3    Song, K.4
  • 7
    • 0142026821 scopus 로고    scopus 로고
    • Innovations in energy efficient and environmentally friendly space-conditioning systems
    • Garimella S. Innovations in energy efficient and environmentally friendly space-conditioning systems. Energy 28 (2003) 1593-1614
    • (2003) Energy , vol.28 , pp. 1593-1614
    • Garimella, S.1
  • 8
    • 0032090229 scopus 로고    scopus 로고
    • Trade-offs in refrigerant selections: past, present, and future
    • Calm J.M., and Didion D.A. Trade-offs in refrigerant selections: past, present, and future. Int J Refrig 21 4 (1998) 308-321
    • (1998) Int J Refrig , vol.21 , Issue.4 , pp. 308-321
    • Calm, J.M.1    Didion, D.A.2
  • 9
    • 0037525418 scopus 로고    scopus 로고
    • Refrigerant data summary
    • Calm J.M., and C Hourahan G. Refrigerant data summary. Eng Sys 18 11 (2001) 74-88
    • (2001) Eng Sys , vol.18 , Issue.11 , pp. 74-88
    • Calm, J.M.1    C Hourahan, G.2
  • 10
    • 18144368949 scopus 로고    scopus 로고
    • Performance assessment of HC-290 as a drop-in substitute to HCFC-22 in a window air conditioner
    • Devotta S., Padalkar A.S., and Sane N.K. Performance assessment of HC-290 as a drop-in substitute to HCFC-22 in a window air conditioner. Int J Refrig 28 3& 4 (2005) 594-604
    • (2005) Int J Refrig , vol.28 , Issue.3-4 , pp. 594-604
    • Devotta, S.1    Padalkar, A.S.2    Sane, N.K.3
  • 11
    • 0036568487 scopus 로고    scopus 로고
    • Emissions and environmental impacts from air-conditioning and refrigeration systems
    • Calm J.M. Emissions and environmental impacts from air-conditioning and refrigeration systems. Int J Refrig 25 3 (2002) 293-305
    • (2002) Int J Refrig , vol.25 , Issue.3 , pp. 293-305
    • Calm, J.M.1
  • 12
    • 0030150731 scopus 로고    scopus 로고
    • An improved correlation for the thermal conductivity of HCFC-123 (2, 2-dichloro-l, l, l-trifluoroethane)
    • Laesecke A., Perkins R.A., and Howley J.B. An improved correlation for the thermal conductivity of HCFC-123 (2, 2-dichloro-l, l, l-trifluoroethane). Int J Refrig 19 4 (1996) 231-238
    • (1996) Int J Refrig , vol.19 , Issue.4 , pp. 231-238
    • Laesecke, A.1    Perkins, R.A.2    Howley, J.B.3
  • 13
    • 0033733693 scopus 로고    scopus 로고
    • Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic binary mixtures for different heating applications
    • Vorster P.P.J., and Meyer J.P. Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic binary mixtures for different heating applications. Int J Refrig 23 4 (2000) 292-311
    • (2000) Int J Refrig , vol.23 , Issue.4 , pp. 292-311
    • Vorster, P.P.J.1    Meyer, J.P.2
  • 14
    • 0034148974 scopus 로고    scopus 로고
    • The effect of a boiling additive on R123 condensation on a vertical integral-fin surface
    • Kedzierski M.A. The effect of a boiling additive on R123 condensation on a vertical integral-fin surface. Int J Refrig 23 2 (2000) 101-111
    • (2000) Int J Refrig , vol.23 , Issue.2 , pp. 101-111
    • Kedzierski, M.A.1
  • 15
    • 0036784807 scopus 로고    scopus 로고
    • Experimental research on geothermal heat pump system with non-azeotropic working fluids
    • Zhao P.C., Zhao L., Ding G.L., and Zhang C.L. Experimental research on geothermal heat pump system with non-azeotropic working fluids. Appl Therm Eng 22 15 (2002) 1749-1761
    • (2002) Appl Therm Eng , vol.22 , Issue.15 , pp. 1749-1761
    • Zhao, P.C.1    Zhao, L.2    Ding, G.L.3    Zhang, C.L.4
  • 16
    • 0037408011 scopus 로고    scopus 로고
    • A semi-theoretical model for predicting refrigerant/lubricant mixture pool boiling heat transfer
    • Kedzierski M.A. A semi-theoretical model for predicting refrigerant/lubricant mixture pool boiling heat transfer. Int J Refrig 26 3 (2003) 337-348
    • (2003) Int J Refrig , vol.26 , Issue.3 , pp. 337-348
    • Kedzierski, M.A.1
  • 17
    • 0033317743 scopus 로고    scopus 로고
    • Experimental measurements for condensation of downward-flowing R123/R134a in a staggered bundle of horizontal low-finned tubes with four fin geometries
    • Honda H., Takamatsu H., and Takata N. Experimental measurements for condensation of downward-flowing R123/R134a in a staggered bundle of horizontal low-finned tubes with four fin geometries. Int J Refrig 22 8 (1999) 615-624
    • (1999) Int J Refrig , vol.22 , Issue.8 , pp. 615-624
    • Honda, H.1    Takamatsu, H.2    Takata, N.3
  • 18
    • 0345004839 scopus 로고    scopus 로고
    • Description of alternative refrigerants with BACKONE equations
    • Calero S., Wendland M., and Fischer J. Description of alternative refrigerants with BACKONE equations. Fluid Phase Equilibr 152 1 (1998) 1-22
    • (1998) Fluid Phase Equilibr , vol.152 , Issue.1 , pp. 1-22
    • Calero, S.1    Wendland, M.2    Fischer, J.3
  • 19
    • 0032164485 scopus 로고    scopus 로고
    • EHD boiling heat transfer enhancement of R123 and R11 on a tube bundle
    • Karayiannis T.G. EHD boiling heat transfer enhancement of R123 and R11 on a tube bundle. Appl Therm Eng 18 9&10 (1998) 809-817
    • (1998) Appl Therm Eng , vol.18 , Issue.9-10 , pp. 809-817
    • Karayiannis, T.G.1
  • 20
    • 0029779078 scopus 로고    scopus 로고
    • Condensation of HCFC-123 in bundles of horizontal finned tubes, effects of fin geometry and tube arrangement
    • Honda H., Takamatsu H., and Takada N. Condensation of HCFC-123 in bundles of horizontal finned tubes, effects of fin geometry and tube arrangement. Int J Refrig 19 l (1996) 1-9
    • (1996) Int J Refrig , vol.19 , Issue.l , pp. 1-9
    • Honda, H.1    Takamatsu, H.2    Takada, N.3
  • 21
    • 0029221142 scopus 로고    scopus 로고
    • Dorantes R, Lallemand A, Prediction of performance of a jet cooling system operating with pure refrigerants or non-azeotropic mixtures, Rev. Int. Froid 18 (1) 21-30.
  • 22
    • 0032667328 scopus 로고    scopus 로고
    • Thermostatic valve control using a non-azeotropic refrigerant, isobutane/propane mixture
    • Castle T.P. Thermostatic valve control using a non-azeotropic refrigerant, isobutane/propane mixture. Int J Refrig 22 4 (1999) 313-318
    • (1999) Int J Refrig , vol.22 , Issue.4 , pp. 313-318
    • Castle, T.P.1
  • 23
    • 0038802897 scopus 로고    scopus 로고
    • Experimental and computer performance study of an automotive air conditioning system with alternative refrigerants
    • Joudi K.A., Mohammed A.S.K., and Aljanabi M.K. Experimental and computer performance study of an automotive air conditioning system with alternative refrigerants. Energ Convers Manage 44 18 (2003) 2959-2976
    • (2003) Energ Convers Manage , vol.44 , Issue.18 , pp. 2959-2976
    • Joudi, K.A.1    Mohammed, A.S.K.2    Aljanabi, M.K.3
  • 24
    • 0347759907 scopus 로고    scopus 로고
    • Ozone friendly HFC134a/HC mixture compatible with mineral oil in refrigeration system improves energy efficiency of a walk in cooler
    • Joseph Sekhar S., Senthil Kumar K., and Mohan Lal D. Ozone friendly HFC134a/HC mixture compatible with mineral oil in refrigeration system improves energy efficiency of a walk in cooler. Energ Convers Manage 45 7-8 (2004) 1175-1186
    • (2004) Energ Convers Manage , vol.45 , Issue.7-8 , pp. 1175-1186
    • Joseph Sekhar, S.1    Senthil Kumar, K.2    Mohan Lal, D.3
  • 25
    • 0037900848 scopus 로고    scopus 로고
    • A comparison of the operating performance of alternative refrigerants
    • Halimic E., Ross D., Agnew B., Anderson A., and Potts I. A comparison of the operating performance of alternative refrigerants. Appl Therm Eng 23 12 (2003) 1441-1451
    • (2003) Appl Therm Eng , vol.23 , Issue.12 , pp. 1441-1451
    • Halimic, E.1    Ross, D.2    Agnew, B.3    Anderson, A.4    Potts, I.5
  • 26
    • 0034148963 scopus 로고    scopus 로고
    • Enhancement of R123 pool boiling by the addition of hydrocarbons
    • Kedzierski M.A. Enhancement of R123 pool boiling by the addition of hydrocarbons. Int J Refrig 23 2 (2000) 89-100
    • (2000) Int J Refrig , vol.23 , Issue.2 , pp. 89-100
    • Kedzierski, M.A.1
  • 27
    • 0034326118 scopus 로고    scopus 로고
    • Testing of propane/isobutane mixture in domestic refrigerators
    • Jung D., Kim C.-B., Song K., and Park B. Testing of propane/isobutane mixture in domestic refrigerators. Int J Refrig 23 (2000) 517-527
    • (2000) Int J Refrig , vol.23 , pp. 517-527
    • Jung, D.1    Kim, C.-B.2    Song, K.3    Park, B.4
  • 28
    • 4544365364 scopus 로고    scopus 로고
    • Experimental study of hydrocarbon mixtures to replace HFC-134a in a domestic refrigerator
    • Wongwises S. Experimental study of hydrocarbon mixtures to replace HFC-134a in a domestic refrigerator. Energ Convers Manage 46 1 (2005) 85-100
    • (2005) Energ Convers Manage , vol.46 , Issue.1 , pp. 85-100
    • Wongwises, S.1
  • 29
    • 0346452096 scopus 로고    scopus 로고
    • Refrigerants for the 21st century
    • Domanski P.A. Refrigerants for the 21st century. J Res Natl Inst Stan 103 5 (1998) 529-533
    • (1998) J Res Natl Inst Stan , vol.103 , Issue.5 , pp. 529-533
    • Domanski, P.A.1
  • 30
    • 0030686685 scopus 로고    scopus 로고
    • On the design of environmentally benign refrigerant mixtures: a mathematical programming approach
    • Duvedi A., and Achenie L.E.K. On the design of environmentally benign refrigerant mixtures: a mathematical programming approach. Comput Chem Eng 21 8 (1997) 915-923
    • (1997) Comput Chem Eng , vol.21 , Issue.8 , pp. 915-923
    • Duvedi, A.1    Achenie, L.E.K.2
  • 31
    • 0038147275 scopus 로고    scopus 로고
    • Prediction of in-tube condensation heat transfer characteristics of binary refrigerant mixtures
    • Jin D.X., Kwonb J.T., and Kima M.H. Prediction of in-tube condensation heat transfer characteristics of binary refrigerant mixtures. Int J Refrig 26 5 (2003) 593-600
    • (2003) Int J Refrig , vol.26 , Issue.5 , pp. 593-600
    • Jin, D.X.1    Kwonb, J.T.2    Kima, M.H.3
  • 32
    • 0345534622 scopus 로고    scopus 로고
    • Effect of mixture composition on the formation of pinch points in condensers and evaporators for zeotropic refrigerant mixtures
    • Venkatarathnam G., and Srinivasa Murthy S. Effect of mixture composition on the formation of pinch points in condensers and evaporators for zeotropic refrigerant mixtures. Int J Refrig 22 3 (1999) 205-215
    • (1999) Int J Refrig , vol.22 , Issue.3 , pp. 205-215
    • Venkatarathnam, G.1    Srinivasa Murthy, S.2
  • 33
    • 35549013509 scopus 로고    scopus 로고
    • Bureau of Indian Standards (BIS) IS 1476 (Part I); 2000.
  • 34
    • 35548966893 scopus 로고    scopus 로고
    • ASHRAE Standard 41.9-2000.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.