메뉴 건너뛰기




Volumn 84, Issue 10, 2012, Pages 4552-4559

Ultra-low flow electrospray ionization-mass spectrometry for improved ionization efficiency in phosphoproteomics

Author keywords

[No Author keywords available]

Indexed keywords

ANALYTICAL STRATEGY; COMPLEMENTARY DATA; ELECTROSPRAY IONIZATION MASS SPECTROMETRY; IN-LINE; IONIZATION EFFICIENCY; NANO-LC-MS; PHOPHORYLATION; PHOSPHOPEPTIDES; PHOSPHOPROTEOMICS; POTENTIAL BENEFITS; PRE-CONCENTRATION TECHNIQUES; PROTEOMICS; RELATIVE FLOW; RELATIVE PEAK INTENSITY; SAMPLE CONCENTRATION; SAMPLE LOADS; SEPARATION CAPILLARY; SEPARATION TECHNIQUES; SYNTHETIC PEPTIDE; TRANSIENT ISOTACHOPHORESIS; VOLUME INJECTION;

EID: 84861118743     PISSN: 00032700     EISSN: None     Source Type: Journal    
DOI: 10.1021/ac300641x     Document Type: Article
Times cited : (82)

References (34)
  • 1
    • 33748168091 scopus 로고
    • Electrospray ion source. Another variation on the free-jet theme
    • Yamashita, M.; Fenn, J. B. Electrospray ion source. Another variation on the free-jet theme J. Phys. Chem. 1984, 88 (20) 4451-4459
    • (1984) J. Phys. Chem. , vol.88 , Issue.20 , pp. 4451-4459
    • Yamashita, M.1    Fenn, J.B.2
  • 3
    • 0022029557 scopus 로고
    • Electrospray interface for liquid chromatographs and mass spectrometers
    • Whitehouse, C. M.; Dreyer, R. N.; Yamashita, M.; Fenn, J. B. Electrospray interface for liquid chromatographs and mass spectrometers Anal. Chem. 1985, 57 (3) 675-679
    • (1985) Anal. Chem. , vol.57 , Issue.3 , pp. 675-679
    • Whitehouse, C.M.1    Dreyer, R.N.2    Yamashita, M.3    Fenn, J.B.4
  • 4
    • 0024438708 scopus 로고
    • Electrospray ionization for mass spectrometry of large biomolecules
    • Fenn, J.; Mann, M.; Meng, C.; Wong, S.; Whitehouse, C. Electrospray ionization for mass spectrometry of large biomolecules Science 1989, 246 (4926) 64-71
    • (1989) Science , vol.246 , Issue.4926 , pp. 64-71
    • Fenn, J.1    Mann, M.2    Meng, C.3    Wong, S.4    Whitehouse, C.5
  • 5
    • 0000648747 scopus 로고
    • Investigations of the electrospray interface for liquid chromatography/mass spectrometry
    • Ikonomou, M. G.; Blades, A. T.; Kebarle, P. Investigations of the electrospray interface for liquid chromatography/mass spectrometry Anal. Chem. 1990, 62 (9) 957-967
    • (1990) Anal. Chem. , vol.62 , Issue.9 , pp. 957-967
    • Ikonomou, M.G.1    Blades, A.T.2    Kebarle, P.3
  • 6
    • 0023979864 scopus 로고
    • Capillary zone electrophoresis-mass spectrometry using an electrospray ionization interface
    • Smith, R. D.; Olivares, J. A.; Nguyen, N. T.; Udseth, H. R. Capillary zone electrophoresis-mass spectrometry using an electrospray ionization interface Anal. Chem. 1988, 60 (5) 436-441
    • (1988) Anal. Chem. , vol.60 , Issue.5 , pp. 436-441
    • Smith, R.D.1    Olivares, J.A.2    Nguyen, N.T.3    Udseth, H.R.4
  • 7
    • 0024290920 scopus 로고
    • Capillary zone electrophoresis-MS
    • Smith, R. D.; Udseth, H. R. Capillary zone electrophoresis-MS Nature 1988, 331 (6157) 639-640
    • (1988) Nature , vol.331 , Issue.6157 , pp. 639-640
    • Smith, R.D.1    Udseth, H.R.2
  • 8
    • 0024234871 scopus 로고
    • On-line capillary zone electrophoresis-ion spray tandem mass spectrometry for the determination of dynorphins
    • Lee, E. D.; Mück, W.; Henion, J. D.; Covey, T. R. On-line capillary zone electrophoresis-ion spray tandem mass spectrometry for the determination of dynorphins J. Chromatogr., A 1988, 458, 313-321
    • (1988) J. Chromatogr., A , vol.458 , pp. 313-321
    • Lee, E.D.1    Mück, W.2    Henion, J.D.3    Covey, T.R.4
  • 10
    • 0029685702 scopus 로고    scopus 로고
    • Analytical Properties of the Nanoelectrospray Ion Source
    • Wilm, M.; Mann, M. Analytical Properties of the Nanoelectrospray Ion Source Anal. Chem. 1996, 68 (1) 1-8
    • (1996) Anal. Chem. , vol.68 , Issue.1 , pp. 1-8
    • Wilm, M.1    Mann, M.2
  • 11
    • 0035577942 scopus 로고    scopus 로고
    • Reduction of signal suppression effects in electrospray MS using a nanosplitting device
    • Gangl, E. T.; Annan, M.; Spooner, N.; Vouros, P. Reduction of signal suppression effects in electrospray MS using a nanosplitting device Anal. Chem. 2001, 73 (23) 5635-5644
    • (2001) Anal. Chem. , vol.73 , Issue.23 , pp. 5635-5644
    • Gangl, E.T.1    Annan, M.2    Spooner, N.3    Vouros, P.4
  • 12
    • 0038574979 scopus 로고    scopus 로고
    • Ion Suppression in Mass Spectrometry
    • Annesley, T. M. Ion Suppression in Mass Spectrometry Clin. Chem. 2003, 49 (7) 1041-1044
    • (2003) Clin. Chem. , vol.49 , Issue.7 , pp. 1041-1044
    • Annesley, T.M.1
  • 13
    • 0037487098 scopus 로고    scopus 로고
    • Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: When does ESI turn into nano-ESI?
    • Schmidt, A.; Karas, M.; Dülcks, T. Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI? J. Am. Soc. Mass Spectrom. 2003, 14 (5) 492-500
    • (2003) J. Am. Soc. Mass Spectrom. , vol.14 , Issue.5 , pp. 492-500
    • Schmidt, A.1    Karas, M.2    Dülcks, T.3
  • 14
    • 51549089601 scopus 로고    scopus 로고
    • Analytical Characterization of the Electrospray Ion Source in the Nanoflow Regime
    • Marginean, I.; Kelly, R. T.; Prior, D. C.; LaMarche, B. L.; Tang, K.; Smith, R. D. Analytical Characterization of the Electrospray Ion Source in the Nanoflow Regime Anal. Chem. 2008, 80 (17) 6573-6579
    • (2008) Anal. Chem. , vol.80 , Issue.17 , pp. 6573-6579
    • Marginean, I.1    Kelly, R.T.2    Prior, D.C.3    Lamarche, B.L.4    Tang, K.5    Smith, R.D.6
  • 15
    • 66149091950 scopus 로고    scopus 로고
    • Improved Electrospray Ionization Efficiency Compensates for Diminished Chromatographic Resolution and Enables Proteomics Analysis of Tyrosine Signaling in Embryonic Stem Cells
    • Ficarro, S. B.; Zhang, Y.; Lu, Y.; Moghimi, A. R.; Askenazi, M.; Hyatt, E.; Smith, E. D.; Boyer, L.; Schlaeger, T. M.; Luckey, C. J.; Marto, J. A. Improved Electrospray Ionization Efficiency Compensates for Diminished Chromatographic Resolution and Enables Proteomics Analysis of Tyrosine Signaling in Embryonic Stem Cells Anal. Chem. 2009, 81 (9) 3440-3447
    • (2009) Anal. Chem. , vol.81 , Issue.9 , pp. 3440-3447
    • Ficarro, S.B.1    Zhang, Y.2    Lu, Y.3    Moghimi, A.R.4    Askenazi, M.5    Hyatt, E.6    Smith, E.D.7    Boyer, L.8    Schlaeger, T.M.9    Luckey, C.J.10    Marto, J.A.11
  • 16
    • 0035863693 scopus 로고    scopus 로고
    • Predicting Electrospray Response from Chromatographic Retention Time
    • Cech, N. B.; Krone, J. R.; Enke, C. G. Predicting Electrospray Response from Chromatographic Retention Time Anal. Chem. 2000, 73 (2) 208-213
    • (2000) Anal. Chem. , vol.73 , Issue.2 , pp. 208-213
    • Cech, N.B.1    Krone, J.R.2    Enke, C.G.3
  • 17
    • 4744364642 scopus 로고    scopus 로고
    • Physicochemical Properties Determining the Detection Probability of Tryptic Peptides in Fourier Transform Mass Spectrometry. A Correlation Study
    • Nielsen, M. L.; Savitski, M. M.; Kjeldsen, F.; Zubarev, R. A. Physicochemical Properties Determining the Detection Probability of Tryptic Peptides in Fourier Transform Mass Spectrometry. A Correlation Study Anal. Chem. 2004, 76 (19) 5872-5877
    • (2004) Anal. Chem. , vol.76 , Issue.19 , pp. 5872-5877
    • Nielsen, M.L.1    Savitski, M.M.2    Kjeldsen, F.3    Zubarev, R.A.4
  • 18
    • 1242338810 scopus 로고    scopus 로고
    • Nanoelectrospray Ionization of Protein Mixtures: Solution pH and Protein pI
    • Pan, P.; Gunawardena, H. P.; Xia, Y.; McLuckey, S. A. Nanoelectrospray Ionization of Protein Mixtures: Solution pH and Protein pI Anal. Chem. 2004, 76 (4) 1165-1174
    • (2004) Anal. Chem. , vol.76 , Issue.4 , pp. 1165-1174
    • Pan, P.1    Gunawardena, H.P.2    Xia, Y.3    McLuckey, S.A.4
  • 20
    • 71549166323 scopus 로고    scopus 로고
    • Immobilized-Metal Affinity Chromatography (IMAC): A Review. In, Richard, R. B. Murray, P. D. Elsevier: San Diego; Vol. pp, Chapter 27.
    • Block, H.; Maertens, B.; Spriestersbach, A.; Brinker, N.; Kubicek, J.; Fabis, R.; Labahn, J.; Schäfer, F., Immobilized-Metal Affinity Chromatography (IMAC): A Review. In Methods in Enzymology, Richard, R. B..; Murray, P. D., Eds.; Elsevier: San Diego, CA, 2009; Vol. 463, pp 439-473, Chapter 27.
    • (2009) Methods in Enzymology , vol.463 , pp. 439-473
    • Block, H.1    Maertens, B.2    Spriestersbach, A.3    Brinker, N.4    Kubicek, J.5    Fabis, R.6    Labahn, J.7    Schäfer, F.8
  • 21
    • 0027315599 scopus 로고
    • Use of small-diameter capillaries for increasing peptide and protein detection sensitivity in capillary electrophoresis-mass spectrometry
    • Wahl, J. H.; Goodlett, D. R.; Udseth, H. R.; Smith, R. D. Use of small-diameter capillaries for increasing peptide and protein detection sensitivity in capillary electrophoresis-mass spectrometry Electrophoresis 1993, 14 (1) 448-457
    • (1993) Electrophoresis , vol.14 , Issue.1 , pp. 448-457
    • Wahl, J.H.1    Goodlett, D.R.2    Udseth, H.R.3    Smith, R.D.4
  • 22
    • 0029841145 scopus 로고    scopus 로고
    • Attomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry
    • Valaskovic, G. A.; Kelleher, N. L.; McLafferty, F. W. Attomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry Science 1996, 273 (5279) 1199-1202
    • (1996) Science , vol.273 , Issue.5279 , pp. 1199-1202
    • Valaskovic, G.A.1    Kelleher, N.L.2    McLafferty, F.W.3
  • 23
    • 33745932059 scopus 로고    scopus 로고
    • Glycoform characterization of erythropoietin combining glycan and intact protein analysis by capillary electrophoresis - Electrospray - time-of-flight mass spectrometry
    • Balaguer, E.; Demelbauer, U.; Pelzing, M.; Sanz-Nebot, V.; Barbosa, J.; Neusüß, C. Glycoform characterization of erythropoietin combining glycan and intact protein analysis by capillary electrophoresis - electrospray - time-of-flight mass spectrometry Electrophoresis 2006, 27 (13) 2638-2650
    • (2006) Electrophoresis , vol.27 , Issue.13 , pp. 2638-2650
    • Balaguer, E.1    Demelbauer, U.2    Pelzing, M.3    Sanz-Nebot, V.4    Barbosa, J.5    Neusüß, C.6
  • 24
    • 66149137243 scopus 로고    scopus 로고
    • Iontophoretic Fraction Collection for Coupling Capillary Zone Electrophoresis with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry
    • Busnel, J.-M.; Josserand, J.; Lion, N.; Girault, H. H. Iontophoretic Fraction Collection for Coupling Capillary Zone Electrophoresis with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Anal. Chem. 2009, 81 (10) 3867-3872
    • (2009) Anal. Chem. , vol.81 , Issue.10 , pp. 3867-3872
    • Busnel, J.-M.1    Josserand, J.2    Lion, N.3    Girault, H.H.4
  • 25
    • 72849140349 scopus 로고    scopus 로고
    • Relevance and use of capillary coatings in capillary electrophoresis-mass spectrometry
    • Huhn, C.; Ramautar, R.; Wuhrer, M.; Somsen, G. Relevance and use of capillary coatings in capillary electrophoresis-mass spectrometry Anal. Bioanal. Chem. 2010, 396 (1) 297-314
    • (2010) Anal. Bioanal. Chem. , vol.396 , Issue.1 , pp. 297-314
    • Huhn, C.1    Ramautar, R.2    Wuhrer, M.3    Somsen, G.4
  • 26
  • 27
    • 34250185717 scopus 로고    scopus 로고
    • Simplifying CE-MS Operation. 2. Interfacing Low-Flow Separation Techniques to Mass Spectrometry Using a Porous Tip
    • Moini, M. Simplifying CE-MS Operation. 2. Interfacing Low-Flow Separation Techniques to Mass Spectrometry Using a Porous Tip Anal. Chem. 2007, 79 (11) 4241-4246
    • (2007) Anal. Chem. , vol.79 , Issue.11 , pp. 4241-4246
    • Moini, M.1
  • 29
    • 0028316170 scopus 로고
    • Capillary electrophoresis instrumentation as a bench-top viscometer
    • Bello, M. S.; Rezzonico, R.; Righetti, P. G. Capillary electrophoresis instrumentation as a bench-top viscometer J. Chromatogr., A 1994, 659 (1) 199-204
    • (1994) J. Chromatogr., A , vol.659 , Issue.1 , pp. 199-204
    • Bello, M.S.1    Rezzonico, R.2    Righetti, P.G.3
  • 30
    • 41149086885 scopus 로고    scopus 로고
    • Capillary-Based Multi Nanoelectrospray Emitters: Improvements in Ion Transmission Efficiency and Implementation with Capillary Reversed-Phase LC-ESI-MS
    • Kelly, R. T.; Page, J. S.; Zhao, R.; Qian, W.-J.; Mottaz, H. M.; Tang, K.; Smith, R. D. Capillary-Based Multi Nanoelectrospray Emitters: Improvements in Ion Transmission Efficiency and Implementation with Capillary Reversed-Phase LC-ESI-MS Anal. Chem. 2007, 80 (1) 143-149
    • (2007) Anal. Chem. , vol.80 , Issue.1 , pp. 143-149
    • Kelly, R.T.1    Page, J.S.2    Zhao, R.3    Qian, W.-J.4    Mottaz, H.M.5    Tang, K.6    Smith, R.D.7
  • 31
    • 33645533680 scopus 로고    scopus 로고
    • Ultra-low flow nanospray for the normalization of conventional liquid chromatography/mass spectrometry through equimolar response: Standard-free quantitative estimation of metabolite levels in drug discovery
    • Valaskovic, G. A.; Utley, L.; Lee, M. S.; Wu, J.-T. Ultra-low flow nanospray for the normalization of conventional liquid chromatography/mass spectrometry through equimolar response: standard-free quantitative estimation of metabolite levels in drug discovery Rapid Commun. Mass Spectrom. 2006, 20 (7) 1087-1096
    • (2006) Rapid Commun. Mass Spectrom. , vol.20 , Issue.7 , pp. 1087-1096
    • Valaskovic, G.A.1    Utley, L.2    Lee, M.S.3    Wu, J.-T.4
  • 32
    • 1942439636 scopus 로고    scopus 로고
    • Ultrasensitive and Quantitative Analyses from Combined Separations-Mass Spectrometry for the Characterization of Proteomes
    • Smith, R. D.; Shen, Y.; Tang, K. Ultrasensitive and Quantitative Analyses from Combined Separations-Mass Spectrometry for the Characterization of Proteomes Acc. Chem. Res. 2004, 37 (4) 269-278
    • (2004) Acc. Chem. Res. , vol.37 , Issue.4 , pp. 269-278
    • Smith, R.D.1    Shen, Y.2    Tang, K.3
  • 33
    • 33847001297 scopus 로고    scopus 로고
    • Ultratrace LC/MS Proteomic Analysis Using 10-μm-i.d. Porous Layer Open Tubular Poly(styrene-divinylbenzene) Capillary Columns
    • Yue, G.; Luo, Q.; Zhang, J.; Wu, S.-L.; Karger, B. L. Ultratrace LC/MS Proteomic Analysis Using 10-μm-i.d. Porous Layer Open Tubular Poly(styrene-divinylbenzene) Capillary Columns Anal. Chem. 2006, 79 (3) 938-946
    • (2006) Anal. Chem. , vol.79 , Issue.3 , pp. 938-946
    • Yue, G.1    Luo, Q.2    Zhang, J.3    Wu, S.-L.4    Karger, B.L.5
  • 34
    • 0001716393 scopus 로고
    • Capillary electrophoresis/electrospray ionization mass spectrometry: Improvement of protein detection limits using on-column transient isotachophoretic sample preconcentration
    • Thompson, T. J.; Foret, F.; Vouros, P.; Karger, B. L. Capillary electrophoresis/electrospray ionization mass spectrometry: improvement of protein detection limits using on-column transient isotachophoretic sample preconcentration Anal. Chem. 1993, 65 (7) 900-906
    • (1993) Anal. Chem. , vol.65 , Issue.7 , pp. 900-906
    • Thompson, T.J.1    Foret, F.2    Vouros, P.3    Karger, B.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.