Volumn 41, Issue 1, 2012, Pages 105-117

Closed-loop insulin delivery in type 1 diabetes

Author keywords

Algorithm; Closed loop; Continuous glucose sensor; Insulin pump

Indexed keywords

GLUCAGON; GLUCOSE; HEMOGLOBIN A1C; INSULIN; INSULIN DERIVATIVE; SHORT ACTING INSULIN;

EID: 84860606886     PISSN: 08898529     EISSN: 15584410     Source Type: Journal    
DOI: 10.1016/j.ecl.2011.12.003     Document Type: Review
Times cited : (69)

References (73)
  • 1
    • 57249098943 scopus 로고    scopus 로고
    • The barrier of hypoglycemia in diabetes
    • Cryer P.E. The barrier of hypoglycemia in diabetes. Diabetes 2008, 57(12):3169-3176.
    • (2008) Diabetes , vol.57 , Issue.12 , pp. 3169-3176
    • Cryer, P.E.1
  • 2
    • 79960328070 scopus 로고    scopus 로고
    • Hypoglycemia in insulin-treated diabetes: a case for increased vigilance
    • Unger J., Parkin C. Hypoglycemia in insulin-treated diabetes: a case for increased vigilance. Postgrad Med 2011, 123(4):81-91.
    • (2011) Postgrad Med , vol.123 , Issue.4 , pp. 81-91
    • Unger, J.1    Parkin, C.2
  • 3
    • 79959616082 scopus 로고    scopus 로고
    • Closed-loop insulin delivery: from bench to clinical practice
    • Hovorka R. Closed-loop insulin delivery: from bench to clinical practice. Nat Rev Endocrinol 2011, 7(7):385-395.
    • (2011) Nat Rev Endocrinol , vol.7 , Issue.7 , pp. 385-395
    • Hovorka, R.1
  • 4
    • 18144421498 scopus 로고    scopus 로고
    • Continuous glucose monitoring: roadmap for 21st century diabetes therapy
    • Klonoff D.C. Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care 2005, 28(5):1231-1239.
    • (2005) Diabetes Care , vol.28 , Issue.5 , pp. 1231-1239
    • Klonoff, D.C.1
  • 5
    • 0036518602 scopus 로고    scopus 로고
    • Continuous subcutaneous insulin infusion at 25 years: evidence base for the expanding use of insulin pump therapy in type 1 diabetes
    • Pickup J., Keen H. Continuous subcutaneous insulin infusion at 25 years: evidence base for the expanding use of insulin pump therapy in type 1 diabetes. Diabetes Care 2002, 25(3):593-598.
    • (2002) Diabetes Care , vol.25 , Issue.3 , pp. 593-598
    • Pickup, J.1    Keen, H.2
  • 6
    • 14844351848 scopus 로고    scopus 로고
    • A critical assessment of algorithms and challenges in the development of a closed-loop artificial pancreas
    • Bequette B.W. A critical assessment of algorithms and challenges in the development of a closed-loop artificial pancreas. Diabetes Technol Ther 2005, 7(1):28-47.
    • (2005) Diabetes Technol Ther , vol.7 , Issue.1 , pp. 28-47
    • Bequette, B.W.1
  • 7
    • 0000268579 scopus 로고
    • Continuous in vivo determination of blood glucose in human subjects
    • Weller C., Linder M., Macaulay A., et al. Continuous in vivo determination of blood glucose in human subjects. Ann N Y Acad Sci 1960, 87:658-668.
    • (1960) Ann N Y Acad Sci , vol.87 , pp. 658-668
    • Weller, C.1    Linder, M.2    Macaulay, A.3
  • 8
    • 0007424620 scopus 로고
    • Automation control of blood sugar. I. A servomechanism for glucose monitoring and control
    • Kadish A. Automation control of blood sugar. I. A servomechanism for glucose monitoring and control. Am J Med Electron 1964, 3:82-86.
    • (1964) Am J Med Electron , vol.3 , pp. 82-86
    • Kadish, A.1
  • 9
    • 0016165501 scopus 로고
    • An artificial endocrine pancreas
    • Albisser A.M., Leibel B.S., Ewart T.G., et al. An artificial endocrine pancreas. Diabetes 1974, 23(5):389-396.
    • (1974) Diabetes , vol.23 , Issue.5 , pp. 389-396
    • Albisser, A.M.1    Leibel, B.S.2    Ewart, T.G.3
  • 10
    • 0016259390 scopus 로고
    • The artificial beta cell-a continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system)
    • Pfeiffer E.F., Thum C., Clemens A.H. The artificial beta cell-a continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system). Horm Metab Res 1974, 6(5):339-342.
    • (1974) Horm Metab Res , vol.6 , Issue.5 , pp. 339-342
    • Pfeiffer, E.F.1    Thum, C.2    Clemens, A.H.3
  • 11
    • 33845497506 scopus 로고    scopus 로고
    • Closed loop insulin delivery using implanted insulin pumps and sensors in type 1 diabetic patients
    • Renard E., Costalat G., Chevassus H., et al. Closed loop insulin delivery using implanted insulin pumps and sensors in type 1 diabetic patients. Diabetes Res Clin Pract 2006, 74(Suppl 2):S173-S177.
    • (2006) Diabetes Res Clin Pract , vol.74 , Issue.SUPPL. 2
    • Renard, E.1    Costalat, G.2    Chevassus, H.3
  • 12
    • 33645051466 scopus 로고    scopus 로고
    • Continuous glucose monitoring and closed-loop systems
    • Hovorka R. Continuous glucose monitoring and closed-loop systems. Diabet Med 2006, 23(1):1-12.
    • (2006) Diabet Med , vol.23 , Issue.1 , pp. 1-12
    • Hovorka, R.1
  • 13
    • 74249093844 scopus 로고    scopus 로고
    • Closed-loop insulin delivery using a subcutaneous glucose sensor and intraperitoneal insulin delivery: feasibility study testing a new model for the artificial pancreas
    • Renard E., Place J., Cantwell M., et al. Closed-loop insulin delivery using a subcutaneous glucose sensor and intraperitoneal insulin delivery: feasibility study testing a new model for the artificial pancreas. Diabetes Care 2010, 33(1):121-127.
    • (2010) Diabetes Care , vol.33 , Issue.1 , pp. 121-127
    • Renard, E.1    Place, J.2    Cantwell, M.3
  • 14
    • 23644439562 scopus 로고    scopus 로고
    • Closed-loop insulin delivery-what lies between where we are and where we are going?
    • Steil G.M., Rebrin K. Closed-loop insulin delivery-what lies between where we are and where we are going?. Expert Opin Drug Deliv 2005, 2(2):353-362.
    • (2005) Expert Opin Drug Deliv , vol.2 , Issue.2 , pp. 353-362
    • Steil, G.M.1    Rebrin, K.2
  • 15
    • 33751506973 scopus 로고    scopus 로고
    • Artificial beta-cell: clinical experience toward an implantable closed-loop insulin delivery system
    • Renard E., Costalat G., Chevassus H., et al. Artificial beta-cell: clinical experience toward an implantable closed-loop insulin delivery system. Diabetes Metab 2006, 32(5 Pt 2):497-502.
    • (2006) Diabetes Metab , vol.32 , Issue.5 PART 2 , pp. 497-502
    • Renard, E.1    Costalat, G.2    Chevassus, H.3
  • 16
    • 0033431643 scopus 로고    scopus 로고
    • The MiniMed Continuous Glucose Monitoring System (CGMS)
    • Mastrototaro J. The MiniMed Continuous Glucose Monitoring System (CGMS). J Pediatr Endocrinol Metab 1999, 12(Suppl 3):751-758.
    • (1999) J Pediatr Endocrinol Metab , vol.12 , Issue.SUPPL. 3 , pp. 751-758
    • Mastrototaro, J.1
  • 17
    • 62449126447 scopus 로고    scopus 로고
    • Glucose sensors: a review of current and emerging technology
    • Oliver N.S., Toumazou C., Cass A.E., et al. Glucose sensors: a review of current and emerging technology. Diabet Med 2009, 26(3):197-210.
    • (2009) Diabet Med , vol.26 , Issue.3 , pp. 197-210
    • Oliver, N.S.1    Toumazou, C.2    Cass, A.E.3
  • 18
    • 0242363717 scopus 로고    scopus 로고
    • A continuous glucose sensor based on wired enzyme technology-results from a 3-day trial in patients with type 1 diabetes
    • Feldman B., Brazg R., Schwartz S., et al. A continuous glucose sensor based on wired enzyme technology-results from a 3-day trial in patients with type 1 diabetes. Diabetes Technol Ther 2003, 5(5):769-779.
    • (2003) Diabetes Technol Ther , vol.5 , Issue.5 , pp. 769-779
    • Feldman, B.1    Brazg, R.2    Schwartz, S.3
  • 19
    • 0033579205 scopus 로고    scopus 로고
    • Noninvasive glucose monitoring: comprehensive clinical results. Cygnus Research Team
    • Tamada J.A., Garg S., Jovanovic L., et al. Noninvasive glucose monitoring: comprehensive clinical results. Cygnus Research Team. JAMA 1999, 282(19):1839-1844.
    • (1999) JAMA , vol.282 , Issue.19 , pp. 1839-1844
    • Tamada, J.A.1    Garg, S.2    Jovanovic, L.3
  • 20
    • 0026452076 scopus 로고
    • Microdialysis measurement of the absolute glucose concentration in subcutaneous adipose tissue allowing glucose monitoring in diabetic patients
    • Bolinder J., Ungerstedt U., Arner P. Microdialysis measurement of the absolute glucose concentration in subcutaneous adipose tissue allowing glucose monitoring in diabetic patients. Diabetologia 1992, 35(12):1177-1180.
    • (1992) Diabetologia , vol.35 , Issue.12 , pp. 1177-1180
    • Bolinder, J.1    Ungerstedt, U.2    Arner, P.3
  • 21
    • 79952197654 scopus 로고    scopus 로고
    • Evaluating the clinical accuracy of GlucoMen®Day: a novel microdialysis-based continuous glucose monitor
    • Valgimigli F., Lucarelli F., Scuffi C., et al. Evaluating the clinical accuracy of GlucoMen®Day: a novel microdialysis-based continuous glucose monitor. J Diabetes Sci Technol 2010, 4(5):1182-1192.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.5 , pp. 1182-1192
    • Valgimigli, F.1    Lucarelli, F.2    Scuffi, C.3
  • 22
    • 79960319709 scopus 로고    scopus 로고
    • Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data
    • Pickup J.C., Freeman S.C., Sutton A.J. Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data. BMJ 2011, 343:d3805.
    • (2011) BMJ , vol.343
    • Pickup, J.C.1    Freeman, S.C.2    Sutton, A.J.3
  • 23
    • 70349254517 scopus 로고    scopus 로고
    • Do we really need continuous glucose monitoring?
    • Peters A. Do we really need continuous glucose monitoring?. Diabetes Technol Ther 2009, 11(Suppl 1):S128-S130.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.SUPPL. 1
    • Peters, A.1
  • 24
    • 80052828858 scopus 로고    scopus 로고
    • Cost-effectiveness of continuous glucose monitoring and intensive insulin therapy for type 1 diabetes
    • McQueen R., Ellis S., Campbell J., et al. Cost-effectiveness of continuous glucose monitoring and intensive insulin therapy for type 1 diabetes. Cost Eff Resour Alloc 2011, 9:13.
    • (2011) Cost Eff Resour Alloc , vol.9 , pp. 13
    • McQueen, R.1    Ellis, S.2    Campbell, J.3
  • 25
    • 33845479275 scopus 로고    scopus 로고
    • CSII in Europe: where are we, where are we going? An analysis of articles published in Infusystems International
    • Selam S. CSII in Europe: where are we, where are we going? An analysis of articles published in Infusystems International. Diabetes Res Clin Pract 2006, 74(Suppl 2):S23-126.
    • (2006) Diabetes Res Clin Pract , vol.74 , Issue.SUPPL. 2
    • Selam, S.1
  • 26
    • 77954830051 scopus 로고    scopus 로고
    • Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes
    • Bergenstal R.M., Tamborlane W.V., Ahmann A., et al. Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med 2010, 363(4):311-320.
    • (2010) N Engl J Med , vol.363 , Issue.4 , pp. 311-320
    • Bergenstal, R.M.1    Tamborlane, W.V.2    Ahmann, A.3
  • 27
    • 33845340831 scopus 로고    scopus 로고
    • OmniPod Insulin Management System: patient perceptions, preference, and glycemic control
    • Zisser H., Jovanovic L. OmniPod Insulin Management System: patient perceptions, preference, and glycemic control. Diabetes Care 2006, 29(9):2175.
    • (2006) Diabetes Care , vol.29 , Issue.9 , pp. 2175
    • Zisser, H.1    Jovanovic, L.2
  • 28
    • 79959233609 scopus 로고    scopus 로고
    • Comparison of pharmacokinetic properties, physicochemical stability, and pump compatibility of 3 rapid-acting insulin analogues-aspart, lispro, and glulisine
    • Bode B.W. Comparison of pharmacokinetic properties, physicochemical stability, and pump compatibility of 3 rapid-acting insulin analogues-aspart, lispro, and glulisine. Endocr Pract 2011, 17(2):271-280.
    • (2011) Endocr Pract , vol.17 , Issue.2 , pp. 271-280
    • Bode, B.W.1
  • 29
    • 78650129263 scopus 로고    scopus 로고
    • Clinical performance of three bolus calculators in subjects with type 1 diabetes mellitus: a head-to-head-to-head comparison
    • Zisser H., Wagner R., Pleus S., et al. Clinical performance of three bolus calculators in subjects with type 1 diabetes mellitus: a head-to-head-to-head comparison. Diabetes Technol Ther 2010, 12(12):955-961.
    • (2010) Diabetes Technol Ther , vol.12 , Issue.12 , pp. 955-961
    • Zisser, H.1    Wagner, R.2    Pleus, S.3
  • 30
    • 0018759042 scopus 로고
    • Feedback control dynamics for glucose controlled insulin infusion system
    • Clemens A.H. Feedback control dynamics for glucose controlled insulin infusion system. Med Prog Technol 1979, 6(3):91-98.
    • (1979) Med Prog Technol , vol.6 , Issue.3 , pp. 91-98
    • Clemens, A.H.1
  • 31
    • 39749162930 scopus 로고    scopus 로고
    • An improved PID switching control strategy for type 1 diabetes
    • Marchetti G., Barolo M., Jovanovic L., et al. An improved PID switching control strategy for type 1 diabetes. IEEE Trans Biomed Eng 2008, 55(3):857-865.
    • (2008) IEEE Trans Biomed Eng , vol.55 , Issue.3 , pp. 857-865
    • Marchetti, G.1    Barolo, M.2    Jovanovic, L.3
  • 32
    • 33845521334 scopus 로고    scopus 로고
    • Feasibility of automating insulin delivery for the treatment of type 1 diabetes
    • Steil G.M., Rebrin K., Darwin C., et al. Feasibility of automating insulin delivery for the treatment of type 1 diabetes. Diabetes 2006, 55(12):3344-3350.
    • (2006) Diabetes , vol.55 , Issue.12 , pp. 3344-3350
    • Steil, G.M.1    Rebrin, K.2    Darwin, C.3
  • 33
    • 77956071742 scopus 로고    scopus 로고
    • Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes
    • Castle J.R., Engle J.M., El Youssef J., et al. Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes. Diabetes Care 2010, 33(6):1282-1287.
    • (2010) Diabetes Care , vol.33 , Issue.6 , pp. 1282-1287
    • Castle, J.R.1    Engle, J.M.2    El Youssef, J.3
  • 34
    • 48649083317 scopus 로고    scopus 로고
    • Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas
    • Weinzimer S.A., Steil G.M., Swan K.L., et al. Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care 2008, 31(5):934-939.
    • (2008) Diabetes Care , vol.31 , Issue.5 , pp. 934-939
    • Weinzimer, S.A.1    Steil, G.M.2    Swan, K.L.3
  • 35
    • 67650850418 scopus 로고    scopus 로고
    • Model predictive control of type 1 diabetes: an in silico trial
    • Magni L., Raimondo D.M., Bossi L., et al. Model predictive control of type 1 diabetes: an in silico trial. J Diabetes Sci Technol 2007, 1(6):804-812.
    • (2007) J Diabetes Sci Technol , vol.1 , Issue.6 , pp. 804-812
    • Magni, L.1    Raimondo, D.M.2    Bossi, L.3
  • 36
    • 4344640337 scopus 로고    scopus 로고
    • Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
    • Hovorka R., Canonico V., Chassin L.J., et al. Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes. Physiol Meas 2004, 25(4):905-920.
    • (2004) Physiol Meas , vol.25 , Issue.4 , pp. 905-920
    • Hovorka, R.1    Canonico, V.2    Chassin, L.J.3
  • 37
    • 77952987107 scopus 로고    scopus 로고
    • A bihormonal closed-loop artificial pancreas for type 1 diabetes
    • El-Khatib F.H., Russell S.J., Nathan D.M., et al. A bihormonal closed-loop artificial pancreas for type 1 diabetes. Sci Transl Med 2010, 2(27):27ra27.
    • (2010) Sci Transl Med , vol.2 , Issue.27
    • El-Khatib, F.H.1    Russell, S.J.2    Nathan, D.M.3
  • 38
    • 77249157244 scopus 로고    scopus 로고
    • Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial
    • Hovorka R., Allen J.M., Elleri D., et al. Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial. Lancet 2010, 375(9716):743-751.
    • (2010) Lancet , vol.375 , Issue.9716 , pp. 743-751
    • Hovorka, R.1    Allen, J.M.2    Elleri, D.3
  • 39
    • 1642452596 scopus 로고    scopus 로고
    • Closed-loop insulin delivery-the path to physiological glucose control
    • Steil G.M., Panteleon A.E., Rebrin K. Closed-loop insulin delivery-the path to physiological glucose control. Adv Drug Deliv Rev 2004, 56(2):125-144.
    • (2004) Adv Drug Deliv Rev , vol.56 , Issue.2 , pp. 125-144
    • Steil, G.M.1    Panteleon, A.E.2    Rebrin, K.3
  • 40
    • 0031304935 scopus 로고    scopus 로고
    • Closed-loop subcutaneous insulin infusion algorithm with a short-acting insulin analog for long-term clinical application of a wearable artificial endocrine pancreas
    • Shimoda S., Nishida K., Sakakida M., et al. Closed-loop subcutaneous insulin infusion algorithm with a short-acting insulin analog for long-term clinical application of a wearable artificial endocrine pancreas. Front Med Biol Eng 1997, 8(3):197-211.
    • (1997) Front Med Biol Eng , vol.8 , Issue.3 , pp. 197-211
    • Shimoda, S.1    Nishida, K.2    Sakakida, M.3
  • 42
    • 77954901769 scopus 로고    scopus 로고
    • MD-logic artificial pancreas system: a pilot study in adults with type 1 diabetes
    • Atlas E., Nimri R., Miller S., et al. MD-logic artificial pancreas system: a pilot study in adults with type 1 diabetes. Diabetes Care 2010, 33(5):1072-1076.
    • (2010) Diabetes Care , vol.33 , Issue.5 , pp. 1072-1076
    • Atlas, E.1    Nimri, R.2    Miller, S.3
  • 43
    • 77953039088 scopus 로고    scopus 로고
    • Control to range for diabetes: functionality and modular architecture
    • Kovatchev B., Patek S., Dassau E., et al. Control to range for diabetes: functionality and modular architecture. J Diabetes Sci Technol 2009, 3(5):1058-1065.
    • (2009) J Diabetes Sci Technol , vol.3 , Issue.5 , pp. 1058-1065
    • Kovatchev, B.1    Patek, S.2    Dassau, E.3
  • 44
    • 77949891806 scopus 로고    scopus 로고
    • Safety constraints in an artificial pancreatic beta cell: an implementation of model predictive control with insulin on board
    • Ellingsen C., Dassau E., Zisser H., et al. Safety constraints in an artificial pancreatic beta cell: an implementation of model predictive control with insulin on board. J Diabetes Sci Technol 2009, 3(3):536-544.
    • (2009) J Diabetes Sci Technol , vol.3 , Issue.3 , pp. 536-544
    • Ellingsen, C.1    Dassau, E.2    Zisser, H.3
  • 45
    • 77950679236 scopus 로고    scopus 로고
    • Suspended insulin infusion during overnight closed-loop glucose control in children and adolescents with Type 1 diabetes
    • Elleri D., Allen J.M., Nodale M., et al. Suspended insulin infusion during overnight closed-loop glucose control in children and adolescents with Type 1 diabetes. Diabet Med 2010, 27(4):480-484.
    • (2010) Diabet Med , vol.27 , Issue.4 , pp. 480-484
    • Elleri, D.1    Allen, J.M.2    Nodale, M.3
  • 46
    • 62249207383 scopus 로고    scopus 로고
    • Modular artificial beta-cell system: a prototype for clinical research
    • Dassau E., Zisser H., Palerm C C., et al. Modular artificial beta-cell system: a prototype for clinical research. J Diabetes Sci Technol 2008, 2(5):863-872.
    • (2008) J Diabetes Sci Technol , vol.2 , Issue.5 , pp. 863-872
    • Dassau, E.1    Zisser, H.2    Palerm C, C.3
  • 47
    • 79955670667 scopus 로고    scopus 로고
    • The effect of insulin feedback on closed loop glucose control
    • Steil G.M., Palerm C.C., Kurtz N., et al. The effect of insulin feedback on closed loop glucose control. J Clin Endocrinol Metab 2011, 96(5):1402-1408.
    • (2011) J Clin Endocrinol Metab , vol.96 , Issue.5 , pp. 1402-1408
    • Steil, G.M.1    Palerm, C.C.2    Kurtz, N.3
  • 48
    • 79954457764 scopus 로고    scopus 로고
    • Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies
    • Hovorka R., Kumareswaran K., Harris J., et al. Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies. BMJ 2011, 342:d1855.
    • (2011) BMJ , vol.342
    • Hovorka, R.1    Kumareswaran, K.2    Harris, J.3
  • 49
    • 70349264249 scopus 로고    scopus 로고
    • Can we really close the loop and how soon? Accelerating the availability of an artificial pancreas: a roadmap to better diabetes outcomes
    • Kowalski A.J. Can we really close the loop and how soon? Accelerating the availability of an artificial pancreas: a roadmap to better diabetes outcomes. Diabetes Technol Ther 2009, 11(Suppl 1):S113-S119.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.SUPPL. 1
    • Kowalski, A.J.1
  • 50
    • 59249094292 scopus 로고    scopus 로고
    • Duration of nocturnal hypoglycemia before seizures
    • Buckingham B., Wilson D.M., Lecher T., et al. Duration of nocturnal hypoglycemia before seizures. Diabetes Care 2008, 31(11):2110-2112.
    • (2008) Diabetes Care , vol.31 , Issue.11 , pp. 2110-2112
    • Buckingham, B.1    Wilson, D.M.2    Lecher, T.3
  • 51
    • 82555164135 scopus 로고    scopus 로고
    • Insulin pump therapy with automated insulin suspension in response to hypoglycemia: reduction in nocturnal hypoglycemia in those at greatest risk
    • Choudhary P., Shin J., Wang Y., et al. Insulin pump therapy with automated insulin suspension in response to hypoglycemia: reduction in nocturnal hypoglycemia in those at greatest risk. Diabetes Care 2011, 34(9):2023-2025.
    • (2011) Diabetes Care , vol.34 , Issue.9 , pp. 2023-2025
    • Choudhary, P.1    Shin, J.2    Wang, Y.3
  • 52
    • 80055028578 scopus 로고    scopus 로고
    • Prevention of hypoglycemia by using low glucose suspend function in sensor-augmented pump therapy
    • Danne T., Kordonouri O., Holder M., et al. Prevention of hypoglycemia by using low glucose suspend function in sensor-augmented pump therapy. Diabetes Technol Ther 2011, 13(11):1129-1134.
    • (2011) Diabetes Technol Ther , vol.13 , Issue.11 , pp. 1129-1134
    • Danne, T.1    Kordonouri, O.2    Holder, M.3
  • 53
    • 77954939888 scopus 로고    scopus 로고
    • Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension
    • Buckingham B., Chase H.P., Dassau E., et al. Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension. Diabetes Care 2010, 33(5):1013-1017.
    • (2010) Diabetes Care , vol.33 , Issue.5 , pp. 1013-1017
    • Buckingham, B.1    Chase, H.P.2    Dassau, E.3
  • 54
    • 64349094595 scopus 로고    scopus 로고
    • Is an automatic pump suspension feature safe for children with type 1 diabetes? An exploratory analysis with a closed-loop system
    • Cengiz E., Swan K.L., Tamborlane W.V., et al. Is an automatic pump suspension feature safe for children with type 1 diabetes? An exploratory analysis with a closed-loop system. Diabetes Technol Ther 2009, 11(4):207-210.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.4 , pp. 207-210
    • Cengiz, E.1    Swan, K.L.2    Tamborlane, W.V.3
  • 55
    • 0025806276 scopus 로고
    • Epidemiology of severe hypoglycemia in the diabetes control and complications trial. The DCCT Research Group
    • Epidemiology of severe hypoglycemia in the diabetes control and complications trial. The DCCT Research Group. Am J Med 1991, 90(4):450-459.
    • (1991) Am J Med , vol.90 , Issue.4 , pp. 450-459
  • 56
    • 0031014593 scopus 로고    scopus 로고
    • Hypoglycemia: incidence and clinical predictors in a large population-based sample of children and adolescents with IDDM
    • Davis E.A., Keating B., Byrne G.C., et al. Hypoglycemia: incidence and clinical predictors in a large population-based sample of children and adolescents with IDDM. Diabetes Care 1997, 20(1):22-25.
    • (1997) Diabetes Care , vol.20 , Issue.1 , pp. 22-25
    • Davis, E.A.1    Keating, B.2    Byrne, G.C.3
  • 57
    • 75749140069 scopus 로고    scopus 로고
    • Parental attitudes towards overnight closed-loop glucose control in children with type 1 diabetes
    • Elleri D., Acerini C.L., Allen J.M., et al. Parental attitudes towards overnight closed-loop glucose control in children with type 1 diabetes. Diabetes Technol Ther 2010, 12(1):35-39.
    • (2010) Diabetes Technol Ther , vol.12 , Issue.1 , pp. 35-39
    • Elleri, D.1    Acerini, C.L.2    Allen, J.M.3
  • 58
    • 77249175519 scopus 로고    scopus 로고
    • Overnight closed-loop insulin delivery with model predictive control: assessment of hypoglycemia and hyperglycemia risk using simulation studies
    • Wilinska M.E., Budiman E.S., Taub M.B., et al. Overnight closed-loop insulin delivery with model predictive control: assessment of hypoglycemia and hyperglycemia risk using simulation studies. J Diabetes Sci Technol 2009, 3(5):1109-1120.
    • (2009) J Diabetes Sci Technol , vol.3 , Issue.5 , pp. 1109-1120
    • Wilinska, M.E.1    Budiman, E.S.2    Taub, M.B.3
  • 59
    • 84860616025 scopus 로고    scopus 로고
    • Day-and-night closed loop (CL) glucose control in adolescents with type 1 diabetes (T1D)
    • Elleri D., Allen J.M., Kumareswaran K., et al. Day-and-night closed loop (CL) glucose control in adolescents with type 1 diabetes (T1D). Diabetes 2011, 60(Suppl 1):A41.
    • (2011) Diabetes , vol.60 , Issue.SUPPL. 1
    • Elleri, D.1    Allen, J.M.2    Kumareswaran, K.3
  • 60
    • 79951699957 scopus 로고    scopus 로고
    • Closed-loop insulin delivery during pregnancy complicated by type 1 diabetes
    • Murphy H.R., Elleri D., Allen J.M., et al. Closed-loop insulin delivery during pregnancy complicated by type 1 diabetes. Diabetes Care 2011, 34(2):406-411.
    • (2011) Diabetes Care , vol.34 , Issue.2 , pp. 406-411
    • Murphy, H.R.1    Elleri, D.2    Allen, J.M.3
  • 61
    • 82555199427 scopus 로고    scopus 로고
    • Safety and efficacy of 24-h closed-loop insulin delivery in well-controlled pregnant women with type 1 diabetes: a randomized crossover case series
    • Murphy H.R., Kumareswaran K., Elleri D., et al. Safety and efficacy of 24-h closed-loop insulin delivery in well-controlled pregnant women with type 1 diabetes: a randomized crossover case series. Diabetes Care 2011, 34(12):2527-2529.
    • (2011) Diabetes Care , vol.34 , Issue.12 , pp. 2527-2529
    • Murphy, H.R.1    Kumareswaran, K.2    Elleri, D.3
  • 62
    • 62249131539 scopus 로고    scopus 로고
    • Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System
    • McGarraugh G., Bergenstal R. Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System. Diabetes Technol Ther 2009, 11(3):145-150.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.3 , pp. 145-150
    • McGarraugh, G.1    Bergenstal, R.2
  • 63
    • 77649182178 scopus 로고    scopus 로고
    • Time lag characterization of two continuous glucose monitoring systems
    • Garg S.K., Voelmle M., Gottlieb P.A. Time lag characterization of two continuous glucose monitoring systems. Diabetes Res Clin Pract 2010, 87(3):348-353.
    • (2010) Diabetes Res Clin Pract , vol.87 , Issue.3 , pp. 348-353
    • Garg, S.K.1    Voelmle, M.2    Gottlieb, P.A.3
  • 64
    • 34247600583 scopus 로고    scopus 로고
    • Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: comparison with frequent laboratory reference measurements
    • Weinstein R.L., Schwartz S.L., Brazg R.L., et al. Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: comparison with frequent laboratory reference measurements. Diabetes Care 2007, 30(5):1125-1130.
    • (2007) Diabetes Care , vol.30 , Issue.5 , pp. 1125-1130
    • Weinstein, R.L.1    Schwartz, S.L.2    Brazg, R.L.3
  • 65
    • 77953066924 scopus 로고    scopus 로고
    • Delays in minimally invasive continuous glucose monitoring devices: a review of current technology
    • Keenan D.B., Mastrototaro J.J., Voskanyan G., et al. Delays in minimally invasive continuous glucose monitoring devices: a review of current technology. J Diabetes Sci Technol 2009, 3(5):1207-1214.
    • (2009) J Diabetes Sci Technol , vol.3 , Issue.5 , pp. 1207-1214
    • Keenan, D.B.1    Mastrototaro, J.J.2    Voskanyan, G.3
  • 66
    • 73949127972 scopus 로고    scopus 로고
    • Measurement delay associated with the Guardian RT continuous glucose monitoring system
    • Wei C., Lunn D.J., Acerini C.L., et al. Measurement delay associated with the Guardian RT continuous glucose monitoring system. Diabet Med 2010, 27(1):117-122.
    • (2010) Diabet Med , vol.27 , Issue.1 , pp. 117-122
    • Wei, C.1    Lunn, D.J.2    Acerini, C.L.3
  • 67
    • 33845383833 scopus 로고    scopus 로고
    • Prevention of hypoglycemia during exercise in children with type 1 diabetes by suspending basal insulin
    • Tsalikian E., Kollman C., Tamborlane W.B., et al. Prevention of hypoglycemia during exercise in children with type 1 diabetes by suspending basal insulin. Diabetes Care 2006, 29(10):2200-2204.
    • (2006) Diabetes Care , vol.29 , Issue.10 , pp. 2200-2204
    • Tsalikian, E.1    Kollman, C.2    Tamborlane, W.B.3
  • 68
    • 0036410334 scopus 로고    scopus 로고
    • Variability of insulin absorption and insulin action
    • Heinemann L. Variability of insulin absorption and insulin action. Diabetes Technol Ther 2002, 4(5):673-682.
    • (2002) Diabetes Technol Ther , vol.4 , Issue.5 , pp. 673-682
    • Heinemann, L.1
  • 69
    • 23644448095 scopus 로고    scopus 로고
    • The dawn phenomenon revisited: implications for diabetes therapy
    • Carroll M.F., Schade D.S. The dawn phenomenon revisited: implications for diabetes therapy. Endocr Pract 2005, 11(1):55-64.
    • (2005) Endocr Pract , vol.11 , Issue.1 , pp. 55-64
    • Carroll, M.F.1    Schade, D.S.2
  • 70
    • 7944233348 scopus 로고    scopus 로고
    • Daily stress and glycaemic control in Type 1 diabetes: individual differences in magnitude, direction, and timing of stress-reactivity
    • Riazi A., Pickup J., Bradley C. Daily stress and glycaemic control in Type 1 diabetes: individual differences in magnitude, direction, and timing of stress-reactivity. Diabetes Res Clin Pract 2004, 66(3):237-244.
    • (2004) Diabetes Res Clin Pract , vol.66 , Issue.3 , pp. 237-244
    • Riazi, A.1    Pickup, J.2    Bradley, C.3
  • 71
    • 0035514447 scopus 로고    scopus 로고
    • The effect of evening alcohol consumption on next-morning glucose control in type 1 diabetes
    • Turner B.C., Jenkins E., Kerr D., et al. The effect of evening alcohol consumption on next-morning glucose control in type 1 diabetes. Diabetes Care 2001, 24(11):1888-1893.
    • (2001) Diabetes Care , vol.24 , Issue.11 , pp. 1888-1893
    • Turner, B.C.1    Jenkins, E.2    Kerr, D.3
  • 72
    • 58449094833 scopus 로고    scopus 로고
    • Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension
    • Buckingham B., Cobry E., Clinton P., et al. Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension. Diabetes Technol Ther 2009, 11(2):93-97.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.2 , pp. 93-97
    • Buckingham, B.1    Cobry, E.2    Clinton, P.3
  • 73
    • 79953021776 scopus 로고    scopus 로고
    • Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: summary of the results
    • Kovatchev B., Cobelli C., Renard E., et al. Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: summary of the results. J Diabetes Sci Technol 2010, 4(6):1374-1381.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.6 , pp. 1374-1381
    • Kovatchev, B.1    Cobelli, C.2    Renard, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.